YMYoshinori Mitamura

Yoshinori Mitamura

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yoshinori Mitamura has a total of 16 co-authors. Here are the top co-authors by number of shared publications:

  • Hiroshi Eguchi

    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan

    3 shared publications
  • Takashi Katome

    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan

    2 shared publications
  • Takeshi Naito

    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan

    2 shared publications
  • A A Mino

    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan

    1 shared publication
  • F Hotta

    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima, Japan

    1 shared publication
  • Machiko Tomida

    Department of Ophthalmology, Institute of Health Biosciences, The University of Tokushima Graduate School, Tokushima

    1 shared publication

Latest Publications

  • QUANTITATIVE ANALYSIS OF CYSTOID MACULAR EDEMA USING SCANNING LASER OPHTHALMOSCOPE IN MODIFIED DARK-FIELD IMAGING

    by Takashi Katome, Yoshinori Mitamura, Toshihiko Nagasawa, Hiroshi Eguchi, Takeshi Naito

    Purpose: To quantitatively analyze cystoid macular edema (CME) using scanning laser ophthalmoscope in the modified dark-field imaging. Methods: We studied 37 eyes with CME associated with different diseases before and after treatment. The CME area was measured with the modified dark-field imaging and fluorescein angiography. The best-corrected visual acuity, mean deviation and macular sensitivity measured by Humphrey automated perimetry, and foveal thickness and macular volume determined by optical coherence tomography were investigated. Results: The CME area could be clearly outlined in 50% with the fluorescein angiography and in 100% with the modified dark-field imaging (P < 0.0001). The CME area calculated using the modified dark-field imaging was significantly correlated with that using the fluorescein angiography (P = 0.0001). Before treatment, the CME area calculated using the modified dark-field imaging was significantly correlated with only the macular volume (P = 0.0230). Three months after treatment, decrease in the CME area was significantly correlated with improvement in the best-corrected visual acuity, mean deviation, macular sensitivity, foveal thickness, and macular volume (P < 0.05 for all). Conclusion: Our findings indicate that scanning laser ophthalmoscope in the modified dark-field imaging can measure the CME area and is useful in analyzing CME quantitatively. The findings can also be used to evaluate the effectiveness of treatment.


  • Open Access

    Aggressive retinal astrocytoma associated with tuberous sclerosis

    by Machiko Tomida, Yoshinori Mitamura, Takashi Katome, Hiroshi Eguchi, Takeshi Naito, Takayuki Harada

    Peer reviewed article authored by (Tomida M, Mitamura Y, Katome T, Eguchi H, Naito T, Harada T). Read article or submit your manuscript for publishing.


  • Open Access

    A Case of Delayed-Onset Propionibacterium acnes Endophthalmitis after Cataract Surgery with Implantation of a Preloaded Intraocular Lens

    by Yuki Hayashi, Hiroshi Eguchi, Tatsuro Miyamoto, Masayuki Inoue, Yoshinori Mitamura

    Purpose: To report a case of delayed-onset endophthalmitis after implantation of a preloaded intraocular lens (IOL) and examine the surgically removed IOL by scanning electron microscopy (SEM). Case: A 77-year-old female underwent uneventful phacoemulsification and aspiration with preloaded silicone IOL implantation. Since intraocular inflammation unexpectedly worsened 1 month after the surgery, she was referred to our hospital. Her visual acuity was hand motion in the left eye. Hypopyon and fibrin formation were observed in the anterior chamber. A diagnosis of postoperative delayed-onset endophthalmitis was made, and vitrectomy with anterior chamber wash-out was performed. As intraocular inflammation remained unchanged postoperatively, an additional surgery with IOL removal was performed. We cultivated the surgically removed samples of aqueous humor and vitreous fluid under both aerobic and anaerobic conditions, performed 16S rDNA clone library analysis of these clinical samples, and examined the removed IOL by SEM. Result: Inflammation subsided after the re-operation. Although cultures of aqueous and vitreous samples were negative, DNA of Propionibacterium acnes was detected in the aqueous humor. The SEM images showed that the rod bacteria and biofilm-like material formed on the tip of the IOL haptic. Conclusion: Delayed-onset endophthalmitis may occur after uneventful implantation of a preloaded IOL. The SEM findings suggested that the tip of the preloaded IOL haptic might scratch bacteria which adhered to the tip of the injector nozzle when the IOL was inserted into the anterior chamber. In some cases with delayed-onset endophthalmitis, IOL removal is needed to eliminate the bacteria which adhere to the tip of the IOL haptic.


  • Open Access

    Comparison of intravitreal bevacizumab to photodynamic therapy for polypoidal choroidal vasculopathy: Short-term results

    by Yoshinori Mitamura, Masayasu Kitahashi, Mariko Kubota-Taniai, Shuichi Yamamoto

    Aims: To compare the short-term therapeutic effects of intravitreal bevacizumab (IVB) to those of photodynamic therapy (PDT) for polypoidal choroidal vasculopathy (PCV). Materials and Methods: Retrospective interventional case study. Eighty-nine eyes of 89 patients with symptomatic PCV were treated by IVB or PDT. Eighteen eyes were treated with a single injection of IVB (s-IVB group), 22 eyes with three consecutive monthly IVB injections (m-IVB group), and 49 eyes with PDT alone (PDT group). The best-corrected visual acuity (BCVA) and OCT-determined central foveal thickness (CFT) were evaluated before, and one and three months after the treatment. For statistical analyses, one-factor ANOVA and Chi-square test were used. Results: The differences in the BCVA and CFT among the three groups at the baseline were not significant (P=0.992, P=0.981, respectively). Three months after the treatment, the BCVA improved by >0.2 logMAR units in two out of 18 eyes (11%) in the s-IVB group, three out of 22 eyes (14%) in the m-IVB group, and 15 out of 49 eyes (31%) in the PDT group (P=0.124). A decrease in the CFT by >20% was achieved in six out of 18 eyes in the s-IVB group, ten eyes (46%) in the m-IVB group, and 35 eyes (71%) in the PDT group (P=0.009). The resolution of polyps was achieved in three out of 18 eyes in the s-IVB group, one eye (5%) in the m-IVB group and 35 eyes (71%) in the PDT group (P < 0.001). Conclusion: The better short-term therapeutic outcomes in the PDT group than in the s-IVB and m-IVB groups indicate that PDT may be more effective than IVB in short term after treatment for PCV.