ARAli Rababah

Ali Rababah

*This is an algorithmically generated author record based on publicly available information.

Ali Rababah has a total of 44 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Osseointegrated Dental Implants as Retention Systems for Digit Prostheses in Finger Amputations

    by Ahmad Alzoubi, Iasmina Alhiasat, Ahmad Almigdad, Ali Rababah, Ahmed Al-Khawaldeh

    Introduction: Finger amputation significantly impairs hand function and self‐image. When surgical reconstruction or replantation is not possible, a finger prosthesis can provide cosmetic and functional benefits. However, conventional prostheses are limited by poor retention and lack of sensation. In this study, we evaluate an alternative method using osseointegrated dental implants to anchor finger prostheses, which provide stable fixation and, in turn, improve function and sensory feedback. Method: Four patients with traumatic amputations of a single finger each (thumb, index, middle, and ring fingers) underwent a two‐stage surgical procedure. In the first stage, a titanium dental implant was placed into the medullary canal of the residual bone. After a three‐month osseointegration period, a second‐stage surgery attached a skin‐penetrating abutment. Finally, a custom‐made, color‐matched silicone prosthesis was secured to the abutment. Outcomes were evaluated through clinical and radiographic follow‐up, along with patient‐reported satisfaction. Results: Three of four patients achieved successful osseointegration by three months. One thumb reconstruction was complicated by nonunion and implant loosening, requiring implant removal. One superficial abutment‐site infection resolved with conservative treatment. Functional outcomes were favorable, with improved grip and pinch strength, preserved joint motion, enhanced sensibility, and high patient satisfaction with cosmetic and functional results. Conclusion: Osseointegrated dental implants may offer a feasible option for retention of digital prostheses in selected patients. Although short‐term outcomes were encouraging, complications can occur, and careful patient selection and biomechanical planning are essential. Larger studies with longer follow‐up are needed to confirm long‐term safety, durability, and implant survival.

  • Open Access

    Development and Pilot Implementation of a 3D Printed Prototype for Surgical Education and Preoperative Planning in Blount's Disease

    by Jamal Al-Nabulsi, Ali Rababah, Mutasem Aldhoon, Ahmad Almarzouq, Ali Alajarmeh, Ahmad Fares

    Blount’s disease is a complex pediatric orthopedic disorder characterized by progressive tibial deformities, necessitating precise surgical planning. Traditional imaging techniques often fail to provide a comprehensive assessment. This study explores the role of 3D-printed anatomical models in enhancing surgical planning and medical training, particularly within the Jordan Royal Medical Services. This study focuses on a 12-year-old patient with a severe multiplanar tibial deformity. A 3D model of the patient’s tibia and fibula was generated using CT scan data, segmented via 3D Slicer software, and printed using FormLabs Form 3BL SLA 3D printer. The printed model was utilized in a pediatric orthopedic workshop attended by over 30 surgeons. Seven surgeons responded to the post-workshop survey. It revealed that all participants found the 3D model beneficial for understanding anatomical deformities, enhancing surgical preparedness, and improving procedural accuracy. However, challenges such as cost, material rigidity, and production time were noted as barriers to widespread adoption. Future research should focus on optimizing material properties and reducing costs to facilitate broader implementation in surgical education and planning in Jordan.


  • Open Access

    Evaluation of five methods for the interpolation of bad leads in the solution of the inverse electrocardiography problem

    by Y Serinagaoglu Dogrusoz, L R Bear, J A Bergquist, A S Rababah, W Good, J Stoks, J Svehlikova, E van Dam, D H Brooks, R S MacLeod

    Objective. This study aims to assess the sensitivity of epicardial potential-based electrocardiographic imaging (ECGI) to the removal or interpolation of bad leads. Approach. We utilized experimental data from two distinct centers. Langendorff-perfused pig (n = 2) and dog (n = 2) hearts were suspended in a human torso-shaped tank and paced from the ventricles. Six different bad lead configurations were designed based on clinical experience. Five interpolation methods were applied to estimate the missing data. Zero-order Tikhonov regularization was used to solve the inverse problem for complete data, data with removed bad leads, and interpolated data. We assessed the quality of interpolated ECG signals and ECGI reconstructions using several metrics, comparing the performance of interpolation methods and the impact of bad lead removal versus interpolation on ECGI. Main results. The performance of ECG interpolation strongly correlated with ECGI reconstruction. The hybrid method exhibited the best performance among interpolation techniques, followed closely by the inverse-forward and Kriging methods. Bad leads located over high amplitude/high gradient areas on the torso significantly impacted ECGI reconstructions, even with minor interpolation errors. The choice between removing or interpolating bad leads depends on the location of missing leads and confidence in interpolation performance. If uncertainty exists, removing bad leads is the safer option, particularly when they are positioned in high amplitude/high gradient regions. In instances where interpolation is necessary, the inverse-forward and Kriging methods, which do not require training, are recommended. Significance. This study represents the first comprehensive evaluation of the advantages and drawbacks of interpolating versus removing bad leads in the context of ECGI, providing valuable insights into ECGI performance.


  • Open Access

    Improved Brain Tumor Segmentation in MR Images with a Modified U-Net

    by Hiam Alquran, Mohammed Alslatie, Ali Rababah, Wan Azani Mustafa

    Detecting brain tumors is crucial in medical diagnostics due to the serious health risks these abnormalities present to patients. Deep learning approaches can significantly improve localization in various medical issues, particularly brain tumors. This paper emphasizes the use of deep learning models to segment brain tumors using a large dataset. The study involves comparing modifications to U-Net structures, including kernel size, number of channels, dropout ratio, and changing the activation function from ReLU to Leaky ReLU. Optimizing these parameters has notably enhanced brain tumor segmentation in MR images, achieving a Global Accuracy of 99.4% and a dice similarity coefficient of 90.2%. The model was trained, validated, and tested on many magnetic resonance images, with a training time not exceeding 19 min on a powerful GPU. This approach can be extended in medical care and hospitals to assist radiologists in identifying tumor locations and suspicious regions, thereby improving diagnosis and treatment effectiveness. The software could also be integrated into MR equipment protocols.


  • The effect of interpolating low amplitude leads on the inverse reconstruction of cardiac electrical activity

    by Ali S. Rababah, Laura R. Bear, Yesim Serinagaoglu Dogrusoz, Wilson Good, Jake Bergquist, Job Stoks, Rob MacLeod, Khaled Rjoob, Michael Jennings, James Mclaughlin, et al.


  • Open Access

    Reliable Deep Learning–Based Detection of Misplaced Chest Electrodes During Electrocardiogram Recording: Algorithm Development and Validation

    by Khaled Rjoob, Raymond Bond, Dewar Finlay, Victoria McGilligan, Stephen J Leslie, Ali Rababah, Aleeha Iftikhar, Daniel Guldenring, Charles Knoery, Anne McShane, et al.

    Background: A 12-lead electrocardiogram (ECG) is the most commonly used method to diagnose patients with cardiovascular diseases. However, there are a number of possible misinterpretations of the ECG that can be caused by several different factors, such as the misplacement of chest electrodes. Objective: The aim of this study is to build advanced algorithms to detect precordial (chest) electrode misplacement. Methods: In this study, we used traditional machine learning (ML) and deep learning (DL) to autodetect the misplacement of electrodes V1 and V2 using features from the resultant ECG. The algorithms were trained using data extracted from high-resolution body surface potential maps of patients who were diagnosed with myocardial infarction, diagnosed with left ventricular hypertrophy, or a normal ECG. Results: DL achieved the highest accuracy in this study for detecting V1 and V2 electrode misplacement, with an accuracy of 93.0% (95% CI 91.46-94.53) for misplacement in the second intercostal space. The performance of DL in the second intercostal space was benchmarked with physicians (n=11 and age 47.3 years, SD 15.5) who were experienced in reading ECGs (mean number of ECGs read in the past year 436.54, SD 397.9). Physicians were poor at recognizing chest electrode misplacement on the ECG and achieved a mean accuracy of 60% (95% CI 56.09-63.90), which was significantly poorer than that of DL (P<.001). Conclusions: DL provides the best performance for detecting chest electrode misplacement when compared with the ability of experienced physicians. DL and ML could be used to help flag ECGs that have been incorrectly recorded and flag that the data may be flawed, which could reduce the number of erroneous diagnoses.


  • Open Access

    Reliable Deep Learning–Based Detection of Misplaced Chest Electrodes During Electrocardiogram Recording: Algorithm Development and Validation (Preprint)

    by Khaled Rjoob, Raymond Bond, Dewar Finlay, Victoria McGilligan, Stephen J Leslie, Ali Rababah, Aleeha Iftikhar, Daniel Guldenring, Charles Knoery, Anne McShane, et al.

    BACKGROUND A 12-lead electrocardiogram (ECG) is the most commonly used method to diagnose patients with cardiovascular diseases. However, there are a number of possible misinterpretations of the ECG that can be caused by several different factors, such as the misplacement of chest electrodes. OBJECTIVE The aim of this study is to build advanced algorithms to detect precordial (chest) electrode misplacement. METHODS In this study, we used traditional machine learning (ML) and deep learning (DL) to autodetect the misplacement of electrodes V1 and V2 using features from the resultant ECG. The algorithms were trained using data extracted from high-resolution body surface potential maps of patients who were diagnosed with myocardial infarction, diagnosed with left ventricular hypertrophy, or a normal ECG. RESULTS DL achieved the highest accuracy in this study for detecting V1 and V2 electrode misplacement, with an accuracy of 93.0% (95% CI 91.46-94.53) for misplacement in the second intercostal space. The performance of DL in the second intercostal space was benchmarked with physicians (n=11 and age 47.3 years, SD 15.5) who were experienced in reading ECGs (mean number of ECGs read in the past year 436.54, SD 397.9). Physicians were poor at recognizing chest electrode misplacement on the ECG and achieved a mean accuracy of 60% (95% CI 56.09-63.90), which was significantly poorer than that of DL (P<.001). CONCLUSIONS DL provides the best performance for detecting chest electrode misplacement when compared with the ability of experienced physicians. DL and ML could be used to help flag ECGs that have been incorrectly recorded and flag that the data may be flawed, which could reduce the number of erroneous diagnoses. CLINICALTRIAL

  • Novel hybrid method for interpolating missing information in body surface potential maps

    by Ali S. Rababah Msc, Raymond R. Bond, Khaled Rjoob Msc, Daniel Guldenring, James McLaughlin, Dewar D. Finlay


  • Open Access

    An Adaptive Laplacian Based Interpolation Algorithm for Noise Reduction in Body Surface Potential Maps

    by Ali Rababah, Dewar Finlay, Daniel Guldenring, Raymond Bond, James McLaughin