Hui Sun
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hui Sun has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Yunbo Shi
School of Measurement and Control Technology and Communication Engineering, Harbin University of Science and Technology, Harbin 150080, China
4 shared publications - Xin Ding
The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentation of Heilongjiang Province, Harbin University of Science and Technology, Harbin 150080, China
3 shared publications Xibo Ding
The Higher Educational Key Laboratory for Measuring & Control Technology and Instrumentation of Heilongjiang Province, Harbin University of Science and Technology , Harbin 150080, China
2 shared publications- Yi Jiang
Department of Communications Engineering, Harbin University of Science and Technology, Harbin 150080, China
2 shared publications - Haibin Wu
Heilongjiang Province Key Laboratory of Laser Spectroscopy Technology and Application, Harbin University of Science and Technology, Harbin 150080, China
1 shared publication - Jiye Song
Department of Communications Engineering, Harbin University of Science and Technology, Harbin 150080, China
1 shared publication
Latest Publications
- Open Access
- 15 July 2025
- Published by MDPI AG in Electronics
- Vol. 14 (14) , 2829
Fast Inference End-to-End Speech Synthesis with Style Diffusion
In recent years, deep learning-based end-to-end Text-To-Speech (TTS) models have made significant progress in enhancing speech naturalness and fluency. However, existing Variational Inference Text-to-Speech (VITS) models still face challenges such as insufficient pitch modeling, inadequate contextual dependency capture, and low inference efficiency in the decoder. To address these issues, this paper proposes an improved TTS framework named Q-VITS. Q-VITS incorporates Rotary Position Embedding (RoPE) into the text encoder to enhance long-sequence modeling, adopts a frame-level prior modeling strategy to optimize one-to-many mappings, and designs a style extractor based on a diffusion model for controllable style rendering. Additionally, the proposed decoder ConfoGAN integrates explicit F0 modeling, Pseudo-Quadrature Mirror Filter (PQMF) multi-band synthesis and Conformer structure. The experimental results demonstrate that Q-VITS outperforms the VITS in terms of speech quality, pitch accuracy, and inference efficiency in both subjective Mean Opinion Score (MOS) and objective Mel-Cepstral Distortion (MCD) and Root Mean Square Error (RMSE) evaluations on a single-speaker dataset, achieving performance close to ground-truth audio. These improvements provide an effective solution for efficient and controllable speech synthesis.
- 15 July 2025
- Published by MDPI AG in Electronics
- Vol. 14 (14) , 2829
Open AccessFast Inference End-to-End Speech Synthesis with Style Diffusion
In recent years, deep learning-based end-to-end Text-To-Speech (TTS) models have made significant progress in enhancing speech naturalness and fluency. However, existing Variational Inference Text-to-Speech (VITS) models still face challenges such as insufficient pitch modeling, inadequate contextual dependency capture, and low inference efficiency in the decoder. To address these issues, this paper proposes an improved TTS framework named Q-VITS. Q-VITS incorporates Rotary Position Embedding (RoPE) into the text encoder to enhance long-sequence modeling, adopts a frame-level prior modeling strategy to optimize one-to-many mappings, and designs a style extractor based on a diffusion model for controllable style rendering. Additionally, the proposed decoder ConfoGAN integrates explicit F0 modeling, Pseudo-Quadrature Mirror Filter (PQMF) multi-band synthesis and Conformer structure. The experimental results demonstrate that Q-VITS outperforms the VITS in terms of speech quality, pitch accuracy, and inference efficiency in both subjective Mean Opinion Score (MOS) and objective Mel-Cepstral Distortion (MCD) and Root Mean Square Error (RMSE) evaluations on a single-speaker dataset, achieving performance close to ground-truth audio. These improvements provide an effective solution for efficient and controllable speech synthesis.
- Open Access
AODV-EOCW: An Energy-Optimized Combined Weighting AODV Protocol for Mobile Ad Hoc Networks
The Ad Hoc On-demand Distance Vector (AODV) is a routing protocol for mobile ad hoc networks (MANETs) and other wireless ad hoc networks. The vanilla AODV protocol is simple and easy to implement because it only uses the hop count as a routing metric. Single-metric route determination also causes problems, such as network congestion and energy exhaustion, which limit the usage of AODV in resource-limited applications. To solve these problems, the authors propose a new routing protocol that combines the analytic hierarchy process (AHP), the entropy weight method (EWM), and AODV. The proposed protocol uses energy, congestion, and the hop count as metrics and weights these three metrics using AHP and EWM. To address the importance of energy in applications, such as drones, the proposed protocol chooses different comparison matrices for AHP at different node residual energy levels. Finally, the node chooses the best route link according to the score (sum of weighted metrics). It is also suitable for wireless sensor networks because the proposed protocol considers the residual energy of the node. The simulation results show that the improved routing protocol can effectively reduce the average end-to-end delay and energy consumption and prolong the lifetime of the whole network.
Open AccessAODV-EOCW: An Energy-Optimized Combined Weighting AODV Protocol for Mobile Ad Hoc Networks
The Ad Hoc On-demand Distance Vector (AODV) is a routing protocol for mobile ad hoc networks (MANETs) and other wireless ad hoc networks. The vanilla AODV protocol is simple and easy to implement because it only uses the hop count as a routing metric. Single-metric route determination also causes problems, such as network congestion and energy exhaustion, which limit the usage of AODV in resource-limited applications. To solve these problems, the authors propose a new routing protocol that combines the analytic hierarchy process (AHP), the entropy weight method (EWM), and AODV. The proposed protocol uses energy, congestion, and the hop count as metrics and weights these three metrics using AHP and EWM. To address the importance of energy in applications, such as drones, the proposed protocol chooses different comparison matrices for AHP at different node residual energy levels. Finally, the node chooses the best route link according to the score (sum of weighted metrics). It is also suitable for wireless sensor networks because the proposed protocol considers the residual energy of the node. The simulation results show that the improved routing protocol can effectively reduce the average end-to-end delay and energy consumption and prolong the lifetime of the whole network.
- Open Access
- 21 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6295
An Ultra-Low-Power-Consumption Urban Sewer Methane Concentration Monitoring System Based on Ultrasound
Methane is the main cause of sewer explosion accidents, and the available monitoring methods mainly use portable gas sensors for on-site detection. However, these methods cannot grasp the dynamic changes in methane in a sewer in real time or make good predictions of methane explosion accidents. Here, we present a low-power online monitoring system for sewer methane in order to ensure the safety of urban sewers. A low-power ultrasonic gas sensor was used to monitor the methane content in biogas. Due to the impacts of changes in CO2, temperature, and humidity in the sewer on the ultrasonic methane measurement results, a corresponding compensation method was proposed. The effectiveness of the compensation method was verified through experiments, which measured the methane concentration under different influences, and the methane values measured before and after compensation were compared. The power consumption was only 1.28 mW when the system worked in intermittent operation mode, and it could operate for about 1.5 years using a lithium battery with a capacity of 5 Ah. The experimental results showed that gas detection accuracy could meet commercial requirements and compensated for the impacts of carbon dioxide, temperature, and humidity.
- 21 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6295
Open AccessAn Ultra-Low-Power-Consumption Urban Sewer Methane Concentration Monitoring System Based on Ultrasound
Methane is the main cause of sewer explosion accidents, and the available monitoring methods mainly use portable gas sensors for on-site detection. However, these methods cannot grasp the dynamic changes in methane in a sewer in real time or make good predictions of methane explosion accidents. Here, we present a low-power online monitoring system for sewer methane in order to ensure the safety of urban sewers. A low-power ultrasonic gas sensor was used to monitor the methane content in biogas. Due to the impacts of changes in CO2, temperature, and humidity in the sewer on the ultrasonic methane measurement results, a corresponding compensation method was proposed. The effectiveness of the compensation method was verified through experiments, which measured the methane concentration under different influences, and the methane values measured before and after compensation were compared. The power consumption was only 1.28 mW when the system worked in intermittent operation mode, and it could operate for about 1.5 years using a lithium battery with a capacity of 5 Ah. The experimental results showed that gas detection accuracy could meet commercial requirements and compensated for the impacts of carbon dioxide, temperature, and humidity.
- Open Access
- 29 April 2023
- Published by MDPI AG in Preprints.org
An Ultra-Low Power Consumption Urban Sewer Methane Concentration Monitoring System Based on Ultrasound
Methane is the main cause of sewer explosion accidents, and the available monitoring methods mainly use portable gas sensors for on-site detection. However, these methods cannot grasp the dynamic changes in methane in a sewer in real time or make better predictions of methane explosion accidents. Here, we present a low-power online monitoring system for sewer methane in order to ensure the safety of urban sewers. A low-power ultrasonic gas sensor was used to monitor the methane content in biogas. Due to the impacts of changes in CO2, temperature, and humidity in the sewer on the ultrasonic methane measurement results, a corresponding compensation method was proposed. The effectiveness of the compensation method was verified through experiments, which measured the methane concentration under different influences, and the methane values measured before and after compensation were compared. The power consumption was only 1.28 mW if the system worked in intermittent operation mode, and it could operate for about 1.5 years by selecting a lithium battery with a capacity of 5 A · H. The experimental results showed that the gas detection accuracy could meet the commercial requirements and had a high compensation for the impacts of carbon dioxide, temperature, and humidity.
- 29 April 2023
- Published by MDPI AG in Preprints.org
Open AccessAn Ultra-Low Power Consumption Urban Sewer Methane Concentration Monitoring System Based on Ultrasound
Methane is the main cause of sewer explosion accidents, and the available monitoring methods mainly use portable gas sensors for on-site detection. However, these methods cannot grasp the dynamic changes in methane in a sewer in real time or make better predictions of methane explosion accidents. Here, we present a low-power online monitoring system for sewer methane in order to ensure the safety of urban sewers. A low-power ultrasonic gas sensor was used to monitor the methane content in biogas. Due to the impacts of changes in CO2, temperature, and humidity in the sewer on the ultrasonic methane measurement results, a corresponding compensation method was proposed. The effectiveness of the compensation method was verified through experiments, which measured the methane concentration under different influences, and the methane values measured before and after compensation were compared. The power consumption was only 1.28 mW if the system worked in intermittent operation mode, and it could operate for about 1.5 years by selecting a lithium battery with a capacity of 5 A · H. The experimental results showed that the gas detection accuracy could meet the commercial requirements and had a high compensation for the impacts of carbon dioxide, temperature, and humidity.
- Open Access
- 1 August 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (8) , 084901
A dual-frequency phase-difference method for ultrasonic hydrogen-concentration detection
Hydrogen has a wide range of energy applications, but hydrogen energy systems can suffer from high-concentration leaks that pose security risks, therefore making the measurement of high-concentration hydrogen very important. Traditional ultrasonic gas-detection methods are based mainly on ultrasonic time-of-flight measurements and can be divided into threshold-detection and phase-difference techniques. Threshold detection suffers from low resolution and a complex structure in gas detection, while the phase-difference technique has high resolution and a simple structure but can only measure the time of flight within one period of the ultrasonic signal. In this study, a dual-frequency phase-difference technique is proposed that solves the problem of multi-period phase detection with the phase-difference technique and can be used to detect high-concentration hydrogen. Simulation analysis and an experiment show that the proposed technique can measure the multi-period phase difference accurately. The maximum hydrogen concentration can reach 50% with an uncertainty of less than 5%, which meets commercial requirements.
- 1 August 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (8) , 084901
Open AccessA dual-frequency phase-difference method for ultrasonic hydrogen-concentration detection
Hydrogen has a wide range of energy applications, but hydrogen energy systems can suffer from high-concentration leaks that pose security risks, therefore making the measurement of high-concentration hydrogen very important. Traditional ultrasonic gas-detection methods are based mainly on ultrasonic time-of-flight measurements and can be divided into threshold-detection and phase-difference techniques. Threshold detection suffers from low resolution and a complex structure in gas detection, while the phase-difference technique has high resolution and a simple structure but can only measure the time of flight within one period of the ultrasonic signal. In this study, a dual-frequency phase-difference technique is proposed that solves the problem of multi-period phase detection with the phase-difference technique and can be used to detect high-concentration hydrogen. Simulation analysis and an experiment show that the proposed technique can measure the multi-period phase difference accurately. The maximum hydrogen concentration can reach 50% with an uncertainty of less than 5%, which meets commercial requirements.
- Open Access
- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 51983-51995
A Method of Full-Range Gas Concentration Detection Based on Multi-Frequency Ultrasonic Cross-Cycle Phase Difference Measurement
Ultrasonic technology is widely used in the field of gas detection due to its advantages of low power consumption, high speed and strong adaptability to the environment. The current ultrasonic time-of-flight (TOF) measurement method has the large measurement error caused by ringing effect, and the phase detection method can only detect the phase change within 2π of a single cycle. These problems cannot meet the requirements of certain high concentration gas detection. This paper proposes a method of multi-frequency ultrasonic phase difference measurement to solve the problem that the phase difference across multiple cycles cannot be detected, hereby realizing full range gas concentration detection, and the continuous wave detection of this method also eliminates ringing effect in TOF. The phase difference within 2π of a single period is obtained by loading a single frequency driving signal on two channels, and the phase difference of low-frequency envelope of the modulated signal is obtained by loading multi-frequency modulated signals. The total cross-cycle phase difference can be obtained by combining the two results, and the measured gas concentration can be obtained by the relationship model between gas concentration and phase difference. The experimental results show that the average absolute error of 4% hydrogen concentration measurement is 0.12%, and the relative error of 99% hydrogen measurement is less than 5%. This method also provides a solution for extracting cross-cycle phase difference in other fields.
- 23 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 51983-51995
Open AccessA Method of Full-Range Gas Concentration Detection Based on Multi-Frequency Ultrasonic Cross-Cycle Phase Difference Measurement
Ultrasonic technology is widely used in the field of gas detection due to its advantages of low power consumption, high speed and strong adaptability to the environment. The current ultrasonic time-of-flight (TOF) measurement method has the large measurement error caused by ringing effect, and the phase detection method can only detect the phase change within 2π of a single cycle. These problems cannot meet the requirements of certain high concentration gas detection. This paper proposes a method of multi-frequency ultrasonic phase difference measurement to solve the problem that the phase difference across multiple cycles cannot be detected, hereby realizing full range gas concentration detection, and the continuous wave detection of this method also eliminates ringing effect in TOF. The phase difference within 2π of a single period is obtained by loading a single frequency driving signal on two channels, and the phase difference of low-frequency envelope of the modulated signal is obtained by loading multi-frequency modulated signals. The total cross-cycle phase difference can be obtained by combining the two results, and the measured gas concentration can be obtained by the relationship model between gas concentration and phase difference. The experimental results show that the average absolute error of 4% hydrogen concentration measurement is 0.12%, and the relative error of 99% hydrogen measurement is less than 5%. This method also provides a solution for extracting cross-cycle phase difference in other fields.