YHYang Hu

Yang Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yang Hu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Yonggang Wang

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, Anhui, China

    5 shared publications
  • Bo Wu

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei, China

    4 shared publications
  • Cheng Li

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Anhui, Hefei, China

    2 shared publications
  • Jianbei Liu

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Anhui, Hefei, China

    2 shared publications
  • Lingyun Li

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Hefei, Anhui, China

    2 shared publications
  • Ming Shao

    Department of Modern Physics, State Key Laboratory of Particle Detection and Electronics (Hefei), University of Science and Technology of China, Anhui, Hefei, China

    2 shared publications

Latest Publications

  • Study of Delay Instabilities in Xilinx FPGA-Embedded Multigigabit Transceivers for Clock Distribution and Synchronization

    by Lingyun Li, Yonggang Wang, Yang Hu, Xiang Zhang

    Multi-gigabit transceivers (MGTs) of Xilinx field-programmable gate arrays (FPGAs) have been widely investigated for the implementation of clock distribution and synchronization systems in physics experiments. Often, the proposed solutions are based on the clock signal recovered from the serial stream. However, since the main purpose of MGTs in FPGA is to achieve high-speed data transmission, the delay stability, especially after initialization/reset operations, is not sufficiently considered. The Xilinx MGTs can be configured in different modes for flexibility. Since Xilinx does not fully explain the implementation structure of each mode, the delay characteristics must be investigated experimentally to achieve high-performance clock transmission. This paper presents a comprehensive investigation of the delay instabilities in Xilinx MGTs and proposes countermeasures to minimize them for stable clock and data transmission. Additionally, a method is proposed to obtain a high-quality recovered clock directly from Xilinx UltraScale and higher-level FPGAs, eliminating the need for an off-chip jitter cleaner. The test results indicate that high clock distribution and synchronization performance can be achieved over the MGT-based serial link once the delay instabilities are properly addressed.


  • Performance Investigation on a Clock Distribution and Synchronization Scheme Over DWDM Optical Links

    by Lingyun Li, Yonggang Wang, Yang Hu, Bo Wu, Ran Wang

    For most large-scale physics experiments, it is desirable that the clock distribution and data transmission are unified on a single optical network. To meet the requirement of current large-scale physics experiments for clock synchronization accuracy in the range of tens of picoseconds, and adapt to the increasingly widespread use of dense wavelength division multiplexing (DWDM) optics, this paper investigates the performance of clock distribution and synchronization scheme based on DWDM optics and high-speed serializer-deserializer (SerDes) transceivers embedded in field programmable gate arrays (FPGAs). By extending our previously proposed simplified calibration procedure based on the White Rabbit protocol to the present asymmetric link, all possible errors, especially the new factors brought about by the asymmetric link, are investigated so that the time uncertainty on the link can be minimized. Using the built test system to carry out multiple Reset and long-term operation tests, the measured clock synchronization accuracy over a 5km optical fiber connection is better than 20ps, and the RMS jitter of the recovered clock is less than 10ps. The test results show that the combination of White Rabbit with DWDM optics can have both high-bandwidth data transmission and high-performance clock synchronization at the same time.


  • Picosecond Timing Electronics for a DIRC-Like Detector at the Super Tau-Charm Facility

    by Ran Wang, Yonggang Wang, Bo Wu, Qiang Cao, Binbin Qi, Xin Li, Xiaoyu Zhou, Yang Hu, Zeyu Wang, Ming Shao, et al.

    The Dirc-Like Time-of-Flight detector (DTOF) at the Super Tau-Charm Facility (STCF) in China is a Cherenkov light detector that uses the TOF technique to identify charged particles. To achieve the expected target that provides a 3σ π/K separation at 2 Ge/c momentum, a single-photon time resolution of better than 50 ps is required while the contribution from electronics should be lower than 15 ps. To meet the requirements with high channel count integration, the timing electronics using leading-edge discrimination and field programmable gate array (FPGA) based time-to-digital converters (TDC) are employed in the DTOF detector. This paper reports the results of the first phase of project where the timing electronics with 128 channels has been constructed and its performance has been evaluated. Including the uncertainty of system clock distribution and synchronization, the intrinsic timing resolution of the electronics is better than 10 ps RMS. Taking fast microchannel plate photomultiplier tubes (MCP-PMT) as Cherenkov photodetectors and adopting time-over-threshold (TOT) measurement for time walk correction, the measured single-photon time resolutions are better than 40 ps RMS. The test results confirm that the proposed timing electronics has advantages of high precision and high integration, which is highly demanded in future picosecond timing detectors.


  • Open Access

    DNA Nanotechnology-Enabled Fabrication of Metal Nanomorphology

    by Mo Xie, Yang Hu, Jue Yin, Ziwei Zhao, Jing Chen, Jie Chao

    In recent decades, DNA nanotechnology has grown into a highly innovative and widely established field. DNA nanostructures have extraordinary structural programmability and can accurately organize nanoscale materials, especially in guiding the synthesis of metal nanomaterials, which have unique advantages in controlling the growth morphology of metal nanomaterials. This review started with the evolution in DNA nanotechnology and the types of DNA nanostructures. Next, a DNA-based nanofabrication technology, DNA metallization, was introduced. In this section, we systematically summarized the DNA-oriented synthesis of metal nanostructures with different morphologies and structures. Furthermore, the applications of metal nanostructures constructed from DNA templates in various fields including electronics, catalysis, sensing, and bioimaging were figured out. Finally, the development prospects and challenges of metal nanostructures formed under the morphology control by DNA nanotechnology were discussed.


  • A Clock Distribution and Synchronization Scheme Over Optical Links for Large-Scale Physics Experiments

    by Yang Hu, Yonggang Wang, Jie Kuang, Bo Wu

    In large-scale physics experiments, there is a trend to implement clock distribution and synchronization over multi-Gigabit serial links on optical networks. The accuracy of clock synchronization in such a fashion is mainly determined by two aspects: one is the stability of the clock distribution over the links, and the other is the employed mechanism of clock synchronization. To achieve a high synchronization accuracy in a range of tens of picoseconds, this article proposes a new optical fiber link and synchronization scheme based on optical circulators and serial transceivers embedded in field-programmable gate arrays (FPGAs). Benefiting from the single wavelength fiber connection, high-precision time-to-digital converters (TDCs) and phase interpolator (PI) sub-block in state-of-the-art Serializer-Deserializer (SerDes) transceivers on FPGAs, the offset of distributed clocks can be measured on-line and precisely compensated. The time synchronization performance is evaluated on a prototype system with three levels of structure. Through multiple power or reset cycles and long-term operation tests, the clock synchronization accuracy over a 5-km fiber connection is measured to be lower than 15 ps, and the recovered clocks at nodes at different levels have independent jitter, all lower than 4.2 ps. In addition, the achieved high performance is also proved to be insensitive to operating temperature and the connection distance.


  • Design of Time-to-Digital Converters for Time-Over-Threshold Measurement in Picosecond Timing Detectors

    by Bo Wu, Yonggang Wang, Qiang Cao, Ziwei Li, Xin Li, Xiaoyu Zhou, Yang Hu, Zeyu Wang, Ming Shao, Jianbei Liu, et al.

    In picosecond timing detectors, the time over threshold (TOT) of detector signals is normally required to be measured to enhance the front-edge timing precision. The extremely narrow pulsewidth of these detector signals has posed challenges to the design of time-to-digital converters (TDCs) based on field programmable gate arrays (FPGAs) for TOT measurement. In this article, an FPGA-based tapped-delay-line (TDL)-type TDC is proposed to simultaneously measure the arrival time and TOT time of nuclear pulses. By propagating the hit signal along a single TDL, the proposed bubble-proof encoding scheme can extract the time information of two transitions of hit signal in one measurement. The minimum measurable TOT time is proved to be limited only by the electrical characteristics of low-voltage differential signaling (LVDS) receivers of FPGAs. Through the performance evaluation on the prototype with a Virtex Ultrascale + FPGA, where the minimum measurable TOT time can be as low as 370 ps, the rms precision reaches 3.0 ps for TOT time measurement. Given the pulsewidths ranging from 0.4 to 1.5 ns, the measured TOT time is highly consistent with the direct readout values from the oscilloscope in a wide temperature range. To apply the TDC into a microchannel plate photomultiplier tube (MCP-PMT)-based timing detector, the front-end electronics board with a dual-threshold TOT measurement is constructed. The joint beam test results show that the coincidence time resolution of two identical detector channels can be improved from 36.5 to 10.3 ps, which demonstrates the significance of TOT measurement to modern picosecond timing detectors.