AEAhmed Gamal Elkhouly

Ahmed Gamal Elkhouly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ahmed Gamal Elkhouly has a total of 61 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy and Safety of Combined Autologous Blood Patch and Doxycycline Pleurodesis for the Management of Persistent Air Leaks in Secondary Spontaneous Pneumothorax: A Randomized Controlled Trial

    by Mohamed Ahmed, Mohammed Y. Alamassi, Ayman F. Yousef, Mohammed S. Ishaq, Ahmed Gamal Elkhouly

    Mohamed Ahmed, M.D., Ph.D.1,2, Mohammed Y. Alamassi, M.D.2, Ayman F. Yousef, M.D.2, Mohammed S. Ishaq, M.D.2, Ahmed Gamal Elkhouly, M.D., Ph.D.1,2. J Chest Surg -0001;0:. https://doi.org/10.5090/jcs.26.076


  • Open Access

    Objective assessment of surgeon’s ergonomics and posture in robotic-assisted (RATS) versus video-assisted thoracoscopic (VATS) lobectomy during vascular structures isolation

    by Ahmed G. Elkhouly, Gowthanan Santhirakumaran, Ben Shanahan, Aya F. Elsebaey, Henrietta Wilson, David Waller, Steven Stamenkovic, Tim Batchelor, Kelvin Lau

    Background: Suboptimal ergonomic postures during surgical procedures increase the susceptibility to work-related musculoskeletal disorders. We objectively compared surgeons’ ergonomics and posture between robotic-assisted thoracic surgery (RATS) and video-assisted thoracic surgery (VATS) lobectomy, using the validated rapid upper limb assessment (RULA) score. Methods: A prospective observational study evaluated 59 lobectomies performed by seven surgeons. Surgeon’s joint angles were tracked during real-life procedures using two software applications (Kinovea-0.9.5 and APECS platform). Sagittal and dorsal videos were recorded during robot ( n = 31) and multiportal thoracoscopic ( n = 28) lobectomies. We calculated neck, shoulder, elbow, trunk, hip, knee, and specific tilt angles to estimate the RULA scores for ergonomic risk during dissection/division of vascular structures. Data were analysed using linear mixed-effects models to adjust for intra-surgeon clustering and anthropometrics. Results: The RULA score was significantly lower in the RATS (4.7±0.5) compared to VATS-group (7.0±0.6) ( p < 0.001), indicating a high ergonomic risk for surgeons in the VATS-group, versus a low-to-medium risk in the RATS-group. The mean joint angles of neck, trunk, neck-tilt and shoulder-tilt were significantly higher in VATS ( p < 0.001), while the elbow angles were significantly greater in RATS ( p < 0.001). There was no significant intergroup difference regarding shoulder angles ( p = 0.21) or operative time ( p = 0.53). A within-surgeon subgroup analysis confirmed these postural advantages are intrinsically driven by the robotic platform. Inter-software agreement between the tracking platforms was excellent (mean intraclass correlation coefficient = 0.94). Conclusions: RATS demonstrated superior ergonomics and posture compared to VATS, with lower associated risk of musculoskeletal disorders. Integrating ergonomic checklists into surgical training is essential to minimize occupational injury risks.

  • Open Access

    Combined Wang Procedure and MatrixRIB Reconstruction for Severe Type II Asphyxiating Thoracic Dysplasia: A Case Report

    by Ahmed Gamal Elkhouly, Ayman Fahad Yousef, Wenlin Wang

    Ahmed Gamal Elkhouly, M.D., Ph.D., Ayman Fahad Yousef, M.D., Wenlin Wang, M.D.. J Chest Surg -0001;0:. https://doi.org/10.5090/jcs.26.052

  • Open Access

    Direct-from-Specimen Detection of Major Carbapenemases by Carbapenem-Resistant K.N.I.V.O. Detection K-Set: Comparative Analysis of Accuracy and Turnaround Time

    by Basant Mostafa Gabr, Mona Abd El-Aziz Gadallah, Wafaa Abd Elaziz, Sama Metwally, Raghda Gabr Mashaal, Rasha A. Abd Ellatif, Ahmed G. Elkhouly, Hanan Salem, Amira E. Oraiby, Bsant S. Kasem, et al.

    To improve clinical decision-making about Carbapenem-resistant Gram-negative bacteria (CR-GNB) infections and halt the spread of resistant microbes, quicker and less expensive diagnostic techniques are required. Thus, the purpose of this study was to thoroughly evaluate the diagnostic efficiency (sensitivity, specificity, and concordance) of direct-from-specimen multiplex lateral flow immunoassay (LFIA) across diverse raw clinical specimens and pathogen types from critically sick patients. A total of 300 non-duplicate samples were tested to detect CR-GNB. Five major Carbapenemase genes were detected directly from the specimen using carbapenem-resistant K.N.I.V.O. detection K-Set and from culture using culture-enhanced multiplex PCR. Turnaround time (TAT) of each method was calculated. The direct LFIA revealed 100% specificity for NDM, KPC, and IMP enzymes in all tested clinical matrices (blood, urine, and respiratory samples). The study demonstrated 100% sensitivity and specificity with perfect categorical agreement (κ = 1.000) for the blaKPC in the Klebsiella pneumoniae and for blaOXA-48 and blaIMP in the Acinetobacter baumannii; however, sensitivity of blaVIM was significantly diminished across all isolates and samples. TAT decreased significantly (p < 0.001) from 30 to 70 h to about 50 min. The tested direct LFIA facilitates the prompt enhancement of lifesaving tailored antibiotic treatment for severe illnesses.

  • Open Access

    Hybrid Congenital Pulmonary Airway Malformation (CPAM) and Bronchopulmonary Sequestration (BPS) in an adult female: a combined surgical approach of a rare case

    by Maha Z. Alamri, Ahmed G. Elkhouly, Adeeb Bazuhair, Mohammed Saleh Ishaq

    Background: Congenital pulmonary airway malformation (CPAM) and bronchopulmonary sequestration (BPS) are rare congenital lung malformations that occur independently or as hybrid lesions. While typically diagnosed in childhood, their occurrence in adults is uncommon. Case presentation: We report a 25-year-old female with chest pain and hemoptysis. Imaging studies revealed multiloculated cystic lesions in the right lower lobe with an anomalous arterial supply, consistent with a hybrid CPAM-BPS. A multidisciplinary approach was employed, including preoperative embolization of the aberrant artery followed by thoracoscopic lobectomy. There were no complications, and histopathology confirmed type 2 CPAM with intralobar sequestration. The patient remained asymptomatic at a six-month follow-up. To our knowledge, this is one of the first documented adult cases with hybrid CPAM-BPS lesions who underwent preoperative arterial embolization followed by thoracoscopic lobectomy. Conclusions: Hybrid CCAM-BPS is a scarce pathology in adults, and few cases have been reported. A high index of suspicion is indicated to diagnose such rare lesions. A combination of preoperative endovascular embolization and thoracoscopic lobectomy is a safe and feasible treatment approach.


  • Open Access

    Objective Assessment of Ergonomics and Performance of Thoracic Surgeons During Real-Life Anatomical Robotic Pulmonary Resections

    by Ahmed G Elkhouly, Gowthanan Santhirakumaran, Ben Shanahan, Tim Batchelor, Henrietta Wilson, David Waller, Steven Stamenkovic, Kelvin Lau

    Objectives: Motion tracking tools have been used in the analysis of surgeons’ technical expertise and posture in simulated endoscopic surgery. But its use in humans in real-life robotic surgery is limited. We analysed the effect of surgeons’ ergonomics and posture on skill metrics for vascular dissection during anatomical pulmonary resection. Methods: In this observational study of vascular dissection/division during segmentectomy or lobectomy, we analysed the inter-group differences of those with more than (group 1) and less than (group 2) 100 robotic resections. The rapid upper limb assessment (RULA) scale was used to estimate ergonomic risk. Operative performance and posture for RULA were measured using the Kinovea-0.9.5 system. Path length of moving instruments, instrument speed, time for task completion, and duration of instruments out of vision were calculated to objectively assess operator performance. Results: Group 1 (expert) comprised 2 males and 1 female, aged 42-61 years. Group 2 (novice) comprised 4 males, aged 31-52 years. Sixty-seven patients underwent robotic anatomical resection using the da Vinci Xi robotic platform, with 180 pulmonary vessels isolations/divisions (Group 1 = 95 vs Group 2 = 85). Group 1 had significantly better RULA ergonomic scores (4.3 vs 4.7, P < .001) which was associated with higher speed (2.8 ± 0.8 vs 2.1 ± 0.2 cm/s, P < .001), shorter task completion time (388 ± 278 vs 520 ± 322 s, P = .001), and shorter duration of instruments out of vision (P < .001). There was no difference in path length (P = .8) and no significant correlation between RULA score and different parameters that assessed surgical performance. Conclusions: Video motion tracking software is an effective and unobtrusive method to evaluate surgical ergonomics and performance in robotic surgery. Better ergonomics were associated with increased surgical experience and improved surgical performance.


  • Open Access

    Bilateral Elastofibroma Dorsi in a Symptomatic Male Patient: Is Surgical Resection Justified? A Case Report

    by Ahmed Gamal Elkhouly, Faisal Hamad, Al Anoud Al Saud, Mohammed Saleh Ishaq

    Ahmed Gamal Elkhouly, M.D., Ph.D., Faisal Hamad, M.D., Al Anoud Al Saud, M.D., Mohammed Saleh Ishaq, M.D.. J Chest Surg -0001;0:. https://doi.org/10.5090/jcs.25.005


  • Nonintubated versus intubated thoracoscopic bullectomy for primary spontaneous pneumothorax: A multicenter propensity-matched analysis

    by Ahmed G Elkhouly, Yekta Altemur Karamustafaoglu, Carlos Galvez, Madhuri Rao, Philip Lerut, Annelies Grimonprez, Firas Abu Akar, Michael Peer, Benedetta Bedetti, Davide Tosi, et al.

    Background: We aimed at comparing in a multicenter propensity-matched analysis, results of nonintubated versus intubated video-assisted thoracic surgery (VATS) bullectomy/blebectomy for primary spontaneous pneumothorax (PSP).Methods: Eleven Institutions participated in the study. A total of 208 patients underwent VATS bullectomy by intubated (IVATS) (N = 138) or nonintubated (NIVATS) (N = 70) anesthesia during 60 months. After propensity matching, 70 pairs of patients were compared. Anesthesia in NIVATS included intercostal (N = 61), paravertebral (N = 5) or thoracic epidural (N = 4) block and sedation with (N = 24) or without (N = 46) laryngeal mask under spontaneous ventilation. In the IVATS group, all patients underwent double-lumen-intubation and mechanical ventilation. Primary outcomes were morbidity and recurrence rates.Results: There was no difference in age (26.7 ± 8 vs 27.4 ± 9 years), body mass index (19.7 ± 2.6 vs 20.6 ± 2.5), and American Society of Anesthesiology score (2 vs 2). Main results show no difference both in morbidity (11.4% vs 12.8%; p = 0.79) and recurrence free rates (92.3% vs 91.4%; p = 0.49) between NIVATS and IVATS, respectively, whereas a difference favoring the NIVATS group was found in anesthesia time ( p < 0.0001) and operative time ( p < 0.0001), drainage time ( p = 0.001), and hospital stay ( p < 0.0001). There was no conversion to thoracotomy and no hospital mortality. One patient in the NIVATS group needed reoperation due to chest wall bleeding.Conclusion: Results of this multicenter propensity-matched study have shown no intergroup difference in morbidity and recurrence rates whereas shorter operation room time and hospital stay favored the NIVATS group, suggesting a potential increase in the role of NIVATS in surgical management of PSP. Further prospective studies are warranted.


  • Quasilobar minimalist lung volume reduction surgery

    by Eugenio Pompeo, Ahmed Elkhouly, Paola Rogliani, Mario Dauri, Michael Peer, Gianluigi Sergiacomi, Roberto Sorge

    : OBJECTIVES: Our goal was to assess the results and the costs of the quasilobar minimalist (QLM) thoracoscopic lung volume reduction (LVR) surgical method developed to minimize the trauma from the operation and the anaesthesia and to maximize the effect of the lobar volume reduction. METHODS: Forty patients with severe emphysema underwent QLM-LVR that entailed adoption of sole intercostal block analgesia and lobar plication through a single thoracoscopic incision. Results were compared after propensity matching with 2 control groups undergoing non-awake resectional LVR with double-lumen tracheal intubation or awake non-resectional LVR by plication with thoracic epidural anaesthesia. As a result, we had 3 matched groups of 30 patients each. RESULTS: Baseline forced expiratory volume in 1 s, residual volume, the 6-min walking test and the modified Medical Research Council dyspnoea index were 0.77 ± 0.18, 4.97 ± 0.6, 328 ± 65 and 3.3 ± 0.7, respectively, with no intergroup difference after propensity score matching. The visual pain score was better (P < 0.007), the hospital stay was shorter (P < 0.04) and overall costs were lower (P < 0.04) in the QLM-LVR group than in the control groups. The morbidity rate was lower with QLM-LVR than with non-awake resectional-LVR (P = 0.006). Significant improvements (P < 0.001) occurred in all study groups during the follow-up period. At 24 months, improvements in residual volume and dyspnoea index were significantly better with QLM-LVR (P < 0.04). CONCLUSIONS: QLM-LVR proved safe and showed better perioperative outcomes and lower procedure-related costs than the control groups. Similar clinical benefit occurred at 12 months, but absolute improvements in residual volume and dyspnoea index were better in the QLM-LVR group at 24 months.


  • Retraction
    Open Access

    A Challenging Case of Electrical Storm in an Implantable Cardioverter Defibrillator Patient

    by Ahmed Elkhouly, Sneha Kola, Derek Enos, Alaa Hijazi, Donald Christmas

    This article has been retracted based on the discovery that the submitting author, Dr. Ahmed Elkhouly, invited his wife to serve as a peer reviewer without properly disclosing this relationship. As this fraudulent peer review was completed and taken into consideration when determining whether to publish this article, Cureus has no choice but to retract this article due to this author misconduct and falsification of peer review. An additional four articles submitted by Dr. Elkhouly have been retracted for the same reason. Cureus greatly regrets that these fraudulent peer reviews were not identified prior to publication. Dr. Elkhouly's residency program has been notified as is consistent with COPE guidelines.