SWShanshan Wang

Shanshan Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shanshan Wang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on the New Topology and Coordinated Control Strategy of Renewable Power Generation Connected MMC-Based DC Power Grid Integration System

    by Shanshan Wang, Shanmeng Qin, Panbo Yang, Yuanyuan Sun, Bing Zhao, Rui Yin, Shengya Sun, Chunyi Tian, Yuetong Zhao

    The modular multilevel converter (MMC) station connected to the islanded renewable energy generation system needs to adopt the voltage frequency (VF) control to provide AC voltage. The single-pole converter fault will unbalance the input and output power of the DC power grid, which causes the DC voltage or the bridge arm current of the non-fault pole to exceed the protection value in the time scale of tens to hundreds of milliseconds, leading to cascading failures. To realize the fault ride-through (FRT) of single-pole converter fault, this paper analyzes the electrical characteristic of the system. Based on the analysis, the existing topology is optimized and the reasonable operation reserved margin is designed. Furthermore, the corresponding control strategy is proposed, which can not only ensure the single-pole converter block fault ride-through but can also realize economic, stable, and resilient power supply and address asymmetrical problems. Finally, the simulation model is built in PSCAD/EMTDC and the simulation results validate the effectiveness of the proposed control strategy.


  • Open Access

    A Topology Analysis-Based MMC-HVDC Grid Transmission Capacity Calculation Method

    by Xiao Yu, Bing Zhao, Shanshan Wang, Tiezhu Wang, Lu Zhang

    Modular multilevel converter-based high voltage direct current (MMC-HVDC) has a broad application prospect in renewable energy transmission. With the development of converter capacity, the transmission capacity calculation for MMC-HVDC grids becomes important for power dispatching. The existing method depends on manual work and is suitable for a simple grid. However, as the grid structure and operation modes become more and more complex, it becomes difficult to calculate the transmission capacity of different operation modes for an MMC-HVDC grid. This paper analyzed and simplified affecting factors and basic topologies. On this basis, a topology-based MMC-HVDC grid transmission capacity calculation method is proposed. First, an MMC-HVDC grid is divided into sending end grid, transmission section lines, and receiving end grid. Then the power limits of these three parts are calculated. Finally, the transmission capacity is determined by analyzing the connection mode of these three parts. This method can be adapted to any kind of MMC-HVDC grid and can be easily programmed.


  • Open Access

    Research on Zero-Voltage Ride Through Control Strategy of Doubly Fed Wind Turbine

    by Kaina Qin, Shanshan Wang, Zhongjian Kang

    With the rapid increase in the proportion of the installed wind power capacity in the total grid capacity, the state has put forward higher and higher requirements for wind power integration into the grid, among which the most difficult requirement is the zero-voltage ride through (ZVRT) capability of the wind turbine. When the voltage drops deeply, a series of transient processes, such as serious overvoltage, overcurrent, or speed rise, will occur in the motor, which will seriously endanger the safe operation of the wind turbine itself and its control system, and cause large-scale off-grid accident of wind generator. Therefore, it is of great significance to improve the uninterrupted operation ability of the wind turbine. Doubly fed induction generator (DFIG) can achieve the best wind energy tracking control in a wide range of wind speed and has the advantage of flexible power regulation. It is widely used at present, but it is sensitive to the grid voltage. In the current study, the DFIG is taken as the research object. The transient process of the DFIG during a fault is analyzed in detail. The mechanism of the rotor overcurrent and DC bus overvoltage of the DFIG during fault is studied. Additionally, the simulation model is built in DIgSILENT. The active crowbar hardware protection circuit is put into the rotor side of the wind turbine, and the extended state observer and terminal sliding mode control are added to the grid side converter control. Through the cooperative control technology, the rotor overcurrent and DC bus overvoltage can be suppressed to realize the zero-voltage ride-through of the doubly fed wind turbine, and ensure the safe and stable operation of the wind farm. Finally, the simulation results are presented to verify the theoretical analysis and the proposed control strategy.


  • Impact of Non-Minimum-Phase Zeros on the Weak-Grid-Tied VSC

    by Guanglu Wu, Bing Zhao, Xi Zhang, Shanshan Wang, Agusti Egea-Alvarez, Yuanyuan Sun, Yingbiao Li, Deyang Guo, Xiaoxin Zhou

    Right-half-plain (RHP) zeros can significantly deteriorate a control system's dynamic performances as it exhibits non-minimum-phase behaviors. In this paper, we investigate the occurrence mechanism of RHP zeros in weak-grid-tied VSCs as well as provide guidance for minimizing their effects. A reduced-order multi-input multi-output (MIMO) transfer function of the weak-grid-tied VSC is firstly obtained. Then, the single-input single-output (SISO) transfer function to study the impact of the RHP zeros on the power response is further derived. The existence of RHP zeros is examined by applying the Routh criterion on the numerator of the SISO open-loop transfer function. We find that RHP zeros can exist either when the VSC works as an inverter or a rectifier. Furthermore, large grid impedance values as well as operation points with high active power values can result in a non-minimum-phase system. It is also shown that RHP zeros limit the minimum PLL bandwidth. Simulation results and RTDS experiments validate the correctness of the analysis and the conclusions obtained.


  • Parameter Design Oriented Analysis of the Current Control Stability of the Weak-Grid-Tied VSC

    by Guanglu Wu, Huadong Sun, Xi Zhang, Agusti Egea-Alvarez, Bing Zhao, Shiyun Xu, Shanshan Wang, Xiaoxin Zhou

    This paper studies the dynamic behaviors of weak-grid-tied VSCs with simplified transfer functions, which provides an accurate stability analysis and useful indications for tuning system parameters. A reduced-order multi-input multi-output (MIMO) transfer function that contains four single-input single-output (SISO) transfer functions for the weak-grid-tied VSC is first presented. It is found that the four SISO transfer functions share the same equivalent open-loop transfer function, i.e., the same stability conclusion. The Bode plots of the equivalent open-loop transfer function show that the inner current loop behaves as a band-pass filter whose maximum gain is approximately at the frequency of the PLL's bandwidth. By stability criterion, the harmonic amplification and instability occur when its maximum gain exceeds 0dB caused by high PLL's bandwidth, large grid impedance or high active power. It is also found that the target system is less stable when it works as an inverter than as a rectifier, due to the risk of the local positive feedback in the inverter mode. An effective criterion is further proposed to guide the selection of a proper PLL's bandwidth to ensure the stability of the VSC system. Simulation results validate the correctness of the analysis and the efficacy of the criterion.


  • Voltage Stability and Transient Symmetrical Fault Current Control of Voltage-Controlled MMCs

    by Yingbiao Li, Jianbo Guo, Heng Wu, Xiongfei Wang, Bing Zhao, Shanshan Wang, Guanglu Wu

    This paper presents a design-oriented analysis on the voltage stability and the transient fault current limitation of voltage-controlled modular multilevel converter (MMC) with L-filters. First, a dual-loop voltage control based on the L-filter plant is systematically designed, where the upper limits of controller parameters for ensuring the small-signal stability are identified. Then, considering the transient fault current limitation during faults, the lower boundaries of the inner current controller parameters are derived. Within the region of allowed controller parameters, the optimization is further made to minimize the closed-loop output impedance of MMC, which enhances the robustness of MMC output voltage against the load current disturbance. Lastly, the time-domain simulations corroborate the theoretical analysis.