ESEndah Safitri

Endah Safitri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Endah Safitri has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    COMPOSITION AND CHARACTERISTICS OF BRICK FOR CONSERVATION AND RESTORATION MATERIALS OF HERITAGE BUILDINGS AS AN INSPIRATION FOR SUSTAINABLE CONSTRUCTION

    by Hana Wardani Puruhita, Senot Sangadji, Endah Safitri, Stefanus Adi Kristiawan

    To realize sustainable Cultural Heritage buildings and preserve cultural heritage, an appropriate concept of cultural heritage restoration and material appropriate to their function are needed. One of which is brick material for heritage buildings. Current bricks are different from heritage/old bricks, visually evident through their shape and colour. Heritage bricks must be studied to find their characteristics and composition so they can be used as cultural heritage restoration materials in the world. The composition and characteristics of heritage bricks have been studied and the results show that the physical and mechanical properties of heritage bricks vary. Therefore, research is needed on the development of renewable/repair heritage bricks as materials in the restoration of cultural heritage buildings, by identifying the characteristics and composition of renewable bricks. The methods applied include experiments and testing in the field and laboratory. The characteristics of renewable bricks in terms of physical strength have been designed with a size of 5.5x14x25.5 without shrinkage because they come from selected clay, have flat surfaces, sharp corners, and colours similar to heritage bricks. Tests were also conducted on the mechanical properties, such as water absorption, apparent density, and compressive strength, of all heritage bricks, and the best values for use as renewable materials were obtained.

  • Open Access

    COMPOSITION AND CHARACTERISTICS OF BRICK FOR CONSERVATION AND RESTORATION MATERIALS OF HERITAGE BUILDINGS AS AN INSPIRATION FOR SUSTAINABLE CONSTRUCTION

    by Hana Wardani Puruhita, Senot Sangadji, Endah Safitri, Stefanus Adi Kristiawan

    To realize sustainable Cultural Heritage buildings and preserve cultural heritage, an appropriate concept of cultural heritage restoration and material appropriate to their function are needed. One of which is brick material for heritage buildings. Current bricks are different from heritage/old bricks, visually evident through their shape and colour. Heritage bricks must be studied to find their characteristics and composition so they can be used as cultural heritage restoration materials in the world. The composition and characteristics of heritage bricks have been studied and the results show that the physical and mechanical properties of heritage bricks vary. Therefore, research is needed on the development of renewable/repair heritage bricks as materials in the restoration of cultural heritage buildings, by identifying the characteristics and composition of renewable bricks. The methods applied include experiments and testing in the field and laboratory. The characteristics of renewable bricks in terms of physical strength have been designed with a size of 5.5x14x25.5 without shrinkage because they come from selected clay, have flat surfaces, sharp corners, and colours similar to heritage bricks. Tests were also conducted on the mechanical properties, such as water absorption, apparent density, and compressive strength, of all heritage bricks, and the best values for use as renewable materials were obtained.

  • The Impact Strength of High Strength Self-Compacting Concrete with Metakaolin and Silica Fume

    by Endah Safitri, Wibowo, Halwan Alfisa Saifullah, Nurfalah Rahendrawan

  • Open Access

    Kajian Setting Time dan Permeabilitas pada Beton Variasi Limbah Granit Sebagai Subtitusi Parsial Agregat Kasar

    by Fauzy Kurnain, Wibowo Wibowo, Endah Safitri

    Currently, infrastructure development is a priority of the Indonesian government which aims to improve the quality of life of the community and equitable distribution of infrastructure development. The need for concrete material as a construction material also increases in line with the increase in infrastructure development. The use of recycled aggregate materials, especially granite waste, is a promising option in sustainable infrastructure development. This study was conducted with the aim of knowing the effect of partial substitution of coarse aggregates using granite waste variations on the binding time and permeability of concrete. Experimental method was chosen in this research. The levels of granite waste used were 0%; 15%; 30%; and 45% by weight of coarse aggregate or gravel. The test specimens used for the concrete bond time study were fresh concrete poured into cube molds measuring 20 cm x 20 cm x 20 cm with a minimum height of 15 cm. Testing concrete bond time using a penetrometer tool. The test specimen for concrete permeability is a cube measuring 15 cm x 15 cm x 15 cm, totaling 12 pieces and tested with a Permeability Test Apparatus (Water Permeabilty Apparatus).The results showed that partial substitution of coarse aggregate with granite waste variation did not affect the setting time of concrete up to a certain level. Based on the results of the research conducted, the initial setting time and final setting time values of 0%, 15%, 30%, and 45% granite content variations fluctuate and the coefficient of determination (R2) value in linear regression is only 0.5 and 0.3. Partial replacement of coarse aggregate with granite waste has an effect on the impermeability of concrete which meets the requirements for medium aggressive impermeable concrete. Water pressure of 5 kg/cm2 for 72 hours applied to the concrete partial replacement of coarse aggregate with granite waste variation resulted in permeability coefficient values of 4.11 x 10-12 cm/s; 3.48 x 10-12 cm/s; 2.17 x 10-12 cm/s; and 3.25 x 10-12 cm/s. The minimum coefficient value of concrete with partial substitution of coarse aggregate with granite waste is obtained at 30% by weight of coarse aggregate. Granite, whose specific gravity is greater than gravel, produces denser and more water-resistant concrete.

  • Open Access

    Flexural behaviour of high-strength self-compacting concrete (HSSCC) RC beam with 12.5% metakaolin and variations of silica fume

    by Sofa Marwoto, Halwan Alfisa Saifullah, Endah Safitri, Wibowo Wibowo

    High-Strength Self-Compacting Concrete (HSSCC) is a type of concrete with superior mechanical material properties and the capacity to self-compact without High-Strength Self-Compacting Concrete (HSSCC) is a type of concrete with superior mechanical material properties and the capacity to self-compact without


  • Open Access

    Kajian Kuat Lentur pada Beton Beton Bubuk Reaktif Dengan Silica Fume 15% dan Variasi Pasir Kuarsa

    by Wibowo Wibowo, Endah Safitri, Bayu Desela Arsanto

    Perkembangan infrastruktur berdampak pada kemajuan ekonomi. Pembangunan gedung bertingkat dan jembatan penghubung antardaerah tidak lepas kaitannya dari material beton. Beton super yang memiliki kualitas lebih baik dari beton konvensional dibutuhkan karena struktur yang tinggi dan bentang yang jenjang, sehingga harus memiliki struktur yang lebih efisien dan ramping. Beton bubuk reaktif merupakan solusi untuk menghadapi tuntutan dalam bidang infrastruktur. Riset ini dimaksudkan untuk mencari tahu pengaruh penggunaan silica fume 15% dari massa binder dan variasi kadar pasir kuarsa terhadap nilai kuat lentur beton bubuk reaktif. Penelitian menggunakan metode eksperimental. Benda uji yang digunakan pada pengujian kuat lentur merupakan balok dimensi 10x10x40 cm dengan sejumlah 21 benda uji dan menggunakan alat pengujian Universal Testing Machine. Pengujian dilakukan saat umur benda uji mencapai 28 hari. Hasil pengujian ini diperoleh nilai kuat lentur beton bubuk reaktif pada variasi kadar pasir kuarsa 0%, 15%, 20%, 25%, 30%, 35% dan 40% senilai 4,7804 MPa; 5,3353 MPa; 6,2002 MPa; 6,7901 MPa; 7,0351 MPa; 6,8350 MPa; dan 6,2749 MPa. Kata Kunci : beton bubuk reaktif, kuat lentur, pasir kuarsa, silica fume


  • Open Access

    KAJIAN KUAT LENTUR PADA BETON MEMADAT MANDIRI MUTU TINGGI DENGAN METAKAOLIN 12,5% DAN VARIASI SILICA FUME

    by Endah Safitri, Wibowo Wobowo, Agus Fatahillah

    Pada era infrastruktur ini kontruksi sangat mengalami kemajuan yang cukup signifikan. Bahan utama kontruksi yang mudah didapatkan adalah beton sehingga kebutuhan beton terus meningkat dan dibutuhkan inovasi beton antara lain adalah beton memadat mandiri dan mutu tinggi. Pembuatan beton HSSCC dengan bahan tambah silica fume dan metakaolin dapat meningkatkan dan memperbaiki kualitas beton. Penelitian ini bertujuan untuk mengetahui pengaruh substitusi metakaolin dan variasi silica fume terhadap parameter beton SCC dan kuat lentur beton dengan metakaolin 12,5% dengan variasi silica fume 0%;9%;11%;13%;15% dari total berat binder, dan digunakan superplasticizer sika viscocrete 1003 sebanyak 1,5% dari total berat binder. Benda uji yang digunakan merupakan balok dengan ukuran 10 x 10 x 40 cm diuji menggunakan mesin uji UTM. Dilakukan pengujian beton segar untuk mengetahui apakah beton segar sudah memenuhi standard SCC yang mengacu pada standar EFNARC 2005 (segregation resistance, passing ability, dan filling ability). Berdasarkan hasil penelitian substitusi metakaolin 12,5% dan variasi silica fume meningkatkan workabilitas pada beton segar memenuhi parameter segregation resistance, passing abilitiy, dan filling ability berdasarkan EFNARC 2005 dan meningkatkan kuat lentur beton pada umur beton 28 hari untuk kadar silica fume 0%;9%;11%;13% dan 15% dengan nilai 5,17 MPa; 5,96 MPa; 6,41 Mpa; 6,27 MPa dan 6,09 MPa.


  • Open Access

    KAJIAN PERMEABILITAS PADA BETON MEMADAT MANDIRI MUTU TINGGI DENGAN METAKAOLIN 12,5% DAN VARIASI SILICA FUME PADA TEKANAN 1 KG/CM2

    by Farida Dzakiyyah Puspita Nurhayati, Endah Safitri, Wibowo Wibowo

    Proyek konstruksi di Indonesia semakin meningkat mengikuti perkembangan ekonomi. Beton mengalami perkembangan demi meningkatkan efektivitas dalam masa pengerjaannya maupun masa layannya. Beton mutu tinggi dibutuhkan untuk menahan beban yang lebih besar, sedangkan beton memadat mandiri atau Self Compacting Concrete (SCC) dibutuhkan untuk meningkatkan efisiensi dalam proses pengerjaan sebuah proyek karena dapat mengalir secara mandiri tanpa bantuan alat penggetar. Penambahan bahan tambah (admixtures) pozzolan dapat meningkatkan ketahanan dan kekuatan beton jika dibandingkan dengan semen portland biasa. Penelitian ini menggunakan pozzolan berupa metakaolin 12,5% dan variasi silica fume 0%: 9%; 11%; 13%; dan 15% dari berat binder. Saat beton berumur 28 hari dilakukan pengujian permeabilitas dengan tekanan 1 kg/cm2 selama 24 jam pada benda uji berupa kubus dengan panjang 15 cm di setiap sisinya. Mengacu pada ACI 301-729 bahwa beton yang dihasilkan tidak memenuhi sebagai beton kedap air dengan nilai koefisien permeabilitas pada kadar 0%; 9%; 11%; 13%; dan 15% berturut-turut sebesar 5,94 × 10-10 m/s; 5,16 × 10-10 m/s; 2,05× 10-10 m/s; 2,80 × 10-10 m/s; 3,99 × 10-10 m/s.

  • Open Access

    Kajian Hubungan Tegangan dan Regangan pada Beton dengan Metakaolin sebagai Pengganti Sebagian Semen

    by Satrio Kiat Widodo, Wibowo Wibowo, Endah Safitri

    Faktor kemajuan pertumbuhan ekonomi suatu negara tidak lepas dari pembangunan insfrastruktur. Pembangunan infrastruktur bertujuan untuk memudahkan mobilisasi orang maupun barang. Infrastruktur yang dibutuhkan seperti pembangunan gedung bertingkat, jalan, dan jembatan yang memiliki material beton, yaitu bahan bangunan yang terbuat dari campuran agregat halus, agregat kasar, semen, air dan bahan tambah lainnya untuk meningkatkan kemampuannya. Penggunaan beton dapat memudahkan pengerjaan karena beton merupakan solusi untuk membuat bangunan secara kuat dan awet. Penelitian ini mengkaji pengaruh penambahan Metakaolin dari penggunaan sebagian semen untuk mengetahui hubungan tegangan dan regangan pada beton. Metode yang diterapkan pada penelitian ini adalah eksperimental dengan benda uji silinder dengan ukuran 15×30 cm dengan jumlah 20 benda uji dan menggunakan alat uji Compression Testing Machine Digital. Pengujian dilakukan saat benda uji berumur 28 hari. Hasil pengujian ini diperoleh nilai tegangan beton normal dengan variasi kadar metakaolin 0%, 5%, 10%, 15%, dan 20% senilai 15,18 MPa; 16,07 MPa; 18,19 MPa; 15,79 MPa; dan 15,56 MPa. Regangan beton normal dengan variasi metakaolin 0%, 5%, 10%, 15%, dan 20% senilai 0,0034; 0,0036; 0,0034; 0,0037; dan 0,0028. Pada penelitian ini beton mengalami nilai tegangan dan regangan secara optimum pada saat variasi metakaolin 10% dengan masing-masing nilai 18,19 MPa dan 0,0034.