ZSZhongye Sun

Zhongye Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhongye Sun has a total of 12 co-authors. Here are the top co-authors by number of shared publications:

  • Bei Wang

    Department of Imaging, Liaocheng Infectious Disease Hospital, Liaocheng, Shandong, China (mainland)

    1 shared publication
  • Bei Zhao

    Liaocheng People's Hospital

    1 shared publication
  • Jian Zhang

    Department of Orthopedic Surgery, Liaocheng People’s Hospital, Liaocheng, Shandong, China (mainland)

    1 shared publication
  • Jun Yan

    Department of Orthopedic Trauma, Beijing Jishuitan Hospital Liaocheng Hospital, No.199, Shuicheng Avenue, Dongchangfu District, Liaocheng, Shandong, 25200, China

    1 shared publication
  • Liankui Yu

    Department of Orthopedic Surgery, Liaocheng People’s Hospital, Liaocheng, Shandong, China (mainland)

    1 shared publication
  • Liren Han

    Department of Orthopaedics, Liaocheng People’s Hospital, Liaocheng, China

    1 shared publication

Latest Publications

  • Open Access

    The study of screw placement parameters for Ogawa type I acromial fractures by 3D simulation

    by Wei Zhang, Zhongye Sun, Weiyan Li, Jun Yan, Liren Han, Shizhang Han, Xiaofei Yang, Bei Zhao

    Background: Acromial fractures are rare and there is no consensus on fixation, but an increasing number of studies have reported using two screws to fix Ogawa type I acromial fractures. The objective of this study was to obtain the ideal length, diameter, insertion point, and angle of the screw using a novel 3D simulation.Methods: The scapular CT data of 100 individuals were obtained to reconstruct 3D models. The transparency of the 3D model was then downgraded along the axial perspective (the view perpendicular to the cross section of the acromion axis) to find the maximum translucent area. Two virtual screws were placed at the anterior edge of the acromion until they penetrated the posterior cortical bon. The largest diameters and lengths of the screw were measured, and the direction and insertion point of the screw were observed.Results: The mean maximum lengths of the medial and lateral screws were 43.33 ± 6.17 mm and 39.23 ± 6.01 mm, respectively. The mean maximum diameters of the medial and lateral screws were 4.71 ± 1.23 mm and 4.97 ± 1.07 mm, respectively. Differences in screw length, diameter, and insertion point between males and females were found. The differences in screw angle between sexes were not statistically significant.Conclusions: Based on a 3D model test, we recommend the size, entry points, and angles of screws for Ogawa type I acromial fractures, providing valuable guidance for clinical work. More accurate screw parameters can be obtained preoperatively by establishing an individualized 3D model.


  • Open Access

    Chemokine (C-C Motif) Ligand 2/Chemokine Receptor 2 (CCR2) Axis Blockade to Delay Chondrocyte Hypertrophy as a Therapeutic Strategy for Osteoarthritis

    by Zidong Wang, Bei Wang, Jian Zhang, Zhensong Wu, Liankui Yu, Zhongye Sun

    Chemokine (C-C Motif) Ligand 2/Chemokine Receptor 2 (CCR2) Axis Blockade to Delay Chondrocyte Hypertrophy as a Therapeutic Strategy for Osteoarthritis - Article abstract #930053