Zhongye Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zhongye Sun has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Bei Wang
Department of Imaging, Liaocheng Infectious Disease Hospital, Liaocheng, Shandong, China (mainland)
1 shared publication- Bei Zhao
Liaocheng People's Hospital
1 shared publication Jian Zhang
Department of Orthopedic Surgery, Liaocheng People’s Hospital, Liaocheng, Shandong, China (mainland)
1 shared publication- Jun Yan
Department of Orthopedic Trauma, Beijing Jishuitan Hospital Liaocheng Hospital, No.199, Shuicheng Avenue, Dongchangfu District, Liaocheng, Shandong, 25200, China
1 shared publication Liankui Yu
Department of Orthopedic Surgery, Liaocheng People’s Hospital, Liaocheng, Shandong, China (mainland)
1 shared publication- Liren Han
Department of Orthopaedics, Liaocheng People’s Hospital, Liaocheng, China
1 shared publication
Latest Publications
- Open Access
- 14 April 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16 (1) , 1-6
The study of screw placement parameters for Ogawa type I acromial fractures by 3D simulation
Background: Acromial fractures are rare and there is no consensus on fixation, but an increasing number of studies have reported using two screws to fix Ogawa type I acromial fractures. The objective of this study was to obtain the ideal length, diameter, insertion point, and angle of the screw using a novel 3D simulation.Methods: The scapular CT data of 100 individuals were obtained to reconstruct 3D models. The transparency of the 3D model was then downgraded along the axial perspective (the view perpendicular to the cross section of the acromion axis) to find the maximum translucent area. Two virtual screws were placed at the anterior edge of the acromion until they penetrated the posterior cortical bon. The largest diameters and lengths of the screw were measured, and the direction and insertion point of the screw were observed.Results: The mean maximum lengths of the medial and lateral screws were 43.33 ± 6.17 mm and 39.23 ± 6.01 mm, respectively. The mean maximum diameters of the medial and lateral screws were 4.71 ± 1.23 mm and 4.97 ± 1.07 mm, respectively. Differences in screw length, diameter, and insertion point between males and females were found. The differences in screw angle between sexes were not statistically significant.Conclusions: Based on a 3D model test, we recommend the size, entry points, and angles of screws for Ogawa type I acromial fractures, providing valuable guidance for clinical work. More accurate screw parameters can be obtained preoperatively by establishing an individualized 3D model.
- 14 April 2021
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 16 (1) , 1-6
Open AccessThe study of screw placement parameters for Ogawa type I acromial fractures by 3D simulation
Background: Acromial fractures are rare and there is no consensus on fixation, but an increasing number of studies have reported using two screws to fix Ogawa type I acromial fractures. The objective of this study was to obtain the ideal length, diameter, insertion point, and angle of the screw using a novel 3D simulation.Methods: The scapular CT data of 100 individuals were obtained to reconstruct 3D models. The transparency of the 3D model was then downgraded along the axial perspective (the view perpendicular to the cross section of the acromion axis) to find the maximum translucent area. Two virtual screws were placed at the anterior edge of the acromion until they penetrated the posterior cortical bon. The largest diameters and lengths of the screw were measured, and the direction and insertion point of the screw were observed.Results: The mean maximum lengths of the medial and lateral screws were 43.33 ± 6.17 mm and 39.23 ± 6.01 mm, respectively. The mean maximum diameters of the medial and lateral screws were 4.71 ± 1.23 mm and 4.97 ± 1.07 mm, respectively. Differences in screw length, diameter, and insertion point between males and females were found. The differences in screw angle between sexes were not statistically significant.Conclusions: Based on a 3D model test, we recommend the size, entry points, and angles of screws for Ogawa type I acromial fractures, providing valuable guidance for clinical work. More accurate screw parameters can be obtained preoperatively by establishing an individualized 3D model.
- Open Access
- 5 February 2021
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 27, e930053-1-e930053-10
Chemokine (C-C Motif) Ligand 2/Chemokine Receptor 2 (CCR2) Axis Blockade to Delay Chondrocyte Hypertrophy as a Therapeutic Strategy for Osteoarthritis
Chemokine (C-C Motif) Ligand 2/Chemokine Receptor 2 (CCR2) Axis Blockade to Delay Chondrocyte Hypertrophy as a Therapeutic Strategy for Osteoarthritis - Article abstract #930053
- 5 February 2021
- Published by International Scientific Information, Inc. in Medical Science Monitor
- Vol. 27, e930053-1-e930053-10
Open AccessChemokine (C-C Motif) Ligand 2/Chemokine Receptor 2 (CCR2) Axis Blockade to Delay Chondrocyte Hypertrophy as a Therapeutic Strategy for Osteoarthritis
Chemokine (C-C Motif) Ligand 2/Chemokine Receptor 2 (CCR2) Axis Blockade to Delay Chondrocyte Hypertrophy as a Therapeutic Strategy for Osteoarthritis - Article abstract #930053