Eric A. Fried
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eric A. Fried has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chang Park
Department of Anesthesiology, Perioperative and Pain Medicine, Mount Sinai Health System, New York, NY, USA
1 shared publication - Daniel Katz
Department of Anesthesiology, Perioperative and Pain Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
1 shared publication - Garrett W. Burnett
Department of Anesthesiology, Perioperative & Pain Medicine, Icahn School of Medicine at Mount Sinai, New York, New York
1 shared publication - George Zhou
Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University School of Medicine, Stanford, California
1 shared publication Gilbert H.L. Tang
Icahn School of Medicine at Mount Sinai, New York, NY
1 shared publicationMatthew A. Levin
Icahn School of Medicine at Mount Sinai, New York, NY
1 shared publication
Latest Publications
- 15 April 2026
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 40 (8) , 2351-2357
Association of Dexmedetomidine Use With Complete Heart Block After Transcatheter Aortic Valve Replacement: A Retrospective Single-Center Cohort Study
- 15 April 2026
- Published by Elsevier in Journal of Cardiothoracic and Vascular Anesthesia
- Vol. 40 (8) , 2351-2357
Association of Dexmedetomidine Use With Complete Heart Block After Transcatheter Aortic Valve Replacement: A Retrospective Single-Center Cohort Study
- Open Access
- 1 April 2021
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 74 (2) , 158-164
Intraoperative aerosol box use: does an educational visual aid reduce contamination?
Background: The aerosol box was rapidly developed and disseminated to minimize viral exposure during aerosolizing procedures during the COVID-19 pandemic, yet users may not understand how to use and clean the device. This could potentially lead to increased viral exposure to subsequent patients and practitioners. We evaluated intraoperative contamination and aerosol box decontamination and the impact of a preoperative educational visual aid. Methods: Using a double-blinded randomized design, forty-four anesthesiology trainees and faculty completed a simulated anesthetic case using an aerosol box contaminated with a fluorescent marker; half of the subjects received a visual aid prior to the simulation. Intraoperative contamination was evaluated at 10 standardized locations using an ultraviolet (UV) light. Next, subjects were instructed to clean the aerosol box for use on the next patient. Following cleaning, the box was evaluated for decontamination using an UV light. Results: Median total contamination score was significantly reduced in the experimental group (5.0 vs. 10.0, P < 0.001). The aerosol box was completely cleaned by 36.4% of subjects in the experimental group compared to 4.5% in the control group (P = 0.009). Conclusions: The use of a visual aid significantly decreased intraoperative contamination and improved box cleaning. Despite these findings, a potentially clinically significant amount of viral exposure may exist. Thorough evaluation of the risks and benefits of the aerosol box should be completed prior to use. If an aerosol box is used, a visual aid should be considered to remind practitioners how to best use and clean the box.
- 1 April 2021
- Published by The Korean Society of Anesthesiologists in Korean Journal of Anesthesiology
- Vol. 74 (2) , 158-164
Open AccessIntraoperative aerosol box use: does an educational visual aid reduce contamination?
Background: The aerosol box was rapidly developed and disseminated to minimize viral exposure during aerosolizing procedures during the COVID-19 pandemic, yet users may not understand how to use and clean the device. This could potentially lead to increased viral exposure to subsequent patients and practitioners. We evaluated intraoperative contamination and aerosol box decontamination and the impact of a preoperative educational visual aid. Methods: Using a double-blinded randomized design, forty-four anesthesiology trainees and faculty completed a simulated anesthetic case using an aerosol box contaminated with a fluorescent marker; half of the subjects received a visual aid prior to the simulation. Intraoperative contamination was evaluated at 10 standardized locations using an ultraviolet (UV) light. Next, subjects were instructed to clean the aerosol box for use on the next patient. Following cleaning, the box was evaluated for decontamination using an UV light. Results: Median total contamination score was significantly reduced in the experimental group (5.0 vs. 10.0, P < 0.001). The aerosol box was completely cleaned by 36.4% of subjects in the experimental group compared to 4.5% in the control group (P = 0.009). Conclusions: The use of a visual aid significantly decreased intraoperative contamination and improved box cleaning. Despite these findings, a potentially clinically significant amount of viral exposure may exist. Thorough evaluation of the risks and benefits of the aerosol box should be completed prior to use. If an aerosol box is used, a visual aid should be considered to remind practitioners how to best use and clean the box.