Amit Gupta
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Amit Gupta has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Yongfeng Gao
Department of Radiology, State University of New York at Stony Brook, Stony Brook, NY, USA
3 shared publications - Zhengrong Liang
Departments of Radiology and Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
3 shared publications - Haifang Li
Stony Brook Medicine, Department of Radiology, Stony Brook, NY 11794, USA
2 shared publications - Jiaxing Tan
Department of Computer Science, City University of New York, New York, NY 10314, USA
2 shared publications Siming Lu
Departments of Radiology and Biomedical Engineering, Stony Brook University, Stony Brook, NY, USA
2 shared publications- Adam C. Powell
HealthHelp, Houston, Texas
1 shared publication
Latest Publications
- 14 May 2025
- Published by Georg Thieme Verlag KG in Digestive Disease Interventions
- Vol. 10 (02) , 080-085
Imaging Workup of Trauma Patients
Trauma remains a leading cause of morbidity and mortality worldwide. Rapid and accurate evaluation of trauma patients is crucial to guiding optimal management. Imaging has become a cornerstone in trauma assessment, playing a critical role in identifying life-threatening injuries and providing detailed information about the extent of trauma to various body systems. This article reviews current imaging applications in trauma and addresses advancements in the utilization of imaging in the trauma workflow.
- 14 May 2025
- Published by Georg Thieme Verlag KG in Digestive Disease Interventions
- Vol. 10 (02) , 080-085
Imaging Workup of Trauma Patients
Trauma remains a leading cause of morbidity and mortality worldwide. Rapid and accurate evaluation of trauma patients is crucial to guiding optimal management. Imaging has become a cornerstone in trauma assessment, playing a critical role in identifying life-threatening injuries and providing detailed information about the extent of trauma to various body systems. This article reviews current imaging applications in trauma and addresses advancements in the utilization of imaging in the trauma workflow.
- Open Access
- 16 February 2023
- Published by Wolters Kluwer Health in Emergency and Critical Care Medicine
- Vol. 3 (1) , 32-35
Soft tissue compartment bleed—the iceberg phenomenon: a case report
Introduction: Hemorrhage control is the essence of trauma care. Conventional teaching is 1 on the floor (ie, external bleeding) and 4 more (thoracic cavity, abdomen, retroperitoneum, and long bones). In this case report, we present a unique case with concealed bleeding into the soft tissue compartment leading to shock. This case triggered to consider the soft tissue compartment as the sixth potential bleeding site in trauma patients in hemorrhagic shock. Case presentation: We present the case with concealed bleeding into the soft tissue compartment posing a challenge in management. On presentation, he had a pulse rate of 117 beats/min, a blood pressure of 90/60 mmHg, and a Glasgow Coma Scale (GCS) score of 9. During resuscitation, the patient's blood pressure dropped to 70/46 mmHg with a GCS of 7 of 15. He was then intubated and reevaluated. Contrast-enhanced computed tomography of the torso revealed a right scapular fracture with a large soft tissue hematoma along the right side of the neck and chest wall, extending up to the right lumbar region. Conclusion: We suggest that the soft tissue compartment is the sixth potential site of internal bleeding in trauma patients, which should not be overlooked after having ruled out the other 5 sites.
- 16 February 2023
- Published by Wolters Kluwer Health in Emergency and Critical Care Medicine
- Vol. 3 (1) , 32-35
Open AccessSoft tissue compartment bleed—the iceberg phenomenon: a case report
Introduction: Hemorrhage control is the essence of trauma care. Conventional teaching is 1 on the floor (ie, external bleeding) and 4 more (thoracic cavity, abdomen, retroperitoneum, and long bones). In this case report, we present a unique case with concealed bleeding into the soft tissue compartment leading to shock. This case triggered to consider the soft tissue compartment as the sixth potential bleeding site in trauma patients in hemorrhagic shock. Case presentation: We present the case with concealed bleeding into the soft tissue compartment posing a challenge in management. On presentation, he had a pulse rate of 117 beats/min, a blood pressure of 90/60 mmHg, and a Glasgow Coma Scale (GCS) score of 9. During resuscitation, the patient's blood pressure dropped to 70/46 mmHg with a GCS of 7 of 15. He was then intubated and reevaluated. Contrast-enhanced computed tomography of the torso revealed a right scapular fracture with a large soft tissue hematoma along the right side of the neck and chest wall, extending up to the right lumbar region. Conclusion: We suggest that the soft tissue compartment is the sixth potential site of internal bleeding in trauma patients, which should not be overlooked after having ruled out the other 5 sites.
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (6) , 1835-1845
Exploring Dual-Energy CT Spectral Information for Machine Learning-Driven Lesion Diagnosis in Pre-Log Domain
In this study, we proposed a computer-aided diagnosis (CADx) framework under dual-energy spectral CT (DECT), which operates directly on the transmission data in the pre-log domain, called CADxDE, to explore the spectral information for lesion diagnosis. The CADxDE includes material identification and machine learning (ML) based CADx. Benefits from DECT’s capability of performing virtual monoenergetic imaging with the identified materials, the responses of different tissue types (e.g., muscle, water, and fat) in lesions at each energy can be explored by ML for CADx. Without losing essential factors in the DECT scan, a pre-log domain model-based iterative reconstruction is adopted to obtain decomposed material images, which are then used to generate the virtual monoenergetic images (VMIs) at selected ${n}$ energies. While these VMIs have the same anatomy, their contrast distribution patterns contain rich information along with the ${n}$ energies for tissue characterization. Thus, a corresponding ML-based CADx is developed to exploit the energy-enhanced tissue features for differentiating malignant from benign lesions. Specifically, an original image-driven multi-channel three-dimensional convolutional neural network (CNN) and extracted lesion feature-based ML CADx methods are developed to show the feasibility of CADxDE. Results from three pathologically proven clinical datasets showed 4.01% to 14.25% higher AUC (area under the receiver operating characteristic curve) scores than the scores of both the conventional DECT data (high and low energy spectrum separately) and the conventional CT data. The mean gain >9.13% in AUC scores indicated that the energy spectral-enhanced tissue features from CADxDE have great potential to improve lesion diagnosis performance.
- 31 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (6) , 1835-1845
Exploring Dual-Energy CT Spectral Information for Machine Learning-Driven Lesion Diagnosis in Pre-Log Domain
In this study, we proposed a computer-aided diagnosis (CADx) framework under dual-energy spectral CT (DECT), which operates directly on the transmission data in the pre-log domain, called CADxDE, to explore the spectral information for lesion diagnosis. The CADxDE includes material identification and machine learning (ML) based CADx. Benefits from DECT’s capability of performing virtual monoenergetic imaging with the identified materials, the responses of different tissue types (e.g., muscle, water, and fat) in lesions at each energy can be explored by ML for CADx. Without losing essential factors in the DECT scan, a pre-log domain model-based iterative reconstruction is adopted to obtain decomposed material images, which are then used to generate the virtual monoenergetic images (VMIs) at selected ${n}$ energies. While these VMIs have the same anatomy, their contrast distribution patterns contain rich information along with the ${n}$ energies for tissue characterization. Thus, a corresponding ML-based CADx is developed to exploit the energy-enhanced tissue features for differentiating malignant from benign lesions. Specifically, an original image-driven multi-channel three-dimensional convolutional neural network (CNN) and extracted lesion feature-based ML CADx methods are developed to show the feasibility of CADxDE. Results from three pathologically proven clinical datasets showed 4.01% to 14.25% higher AUC (area under the receiver operating characteristic curve) scores than the scores of both the conventional DECT data (high and low energy spectrum separately) and the conventional CT data. The mean gain >9.13% in AUC scores indicated that the energy spectral-enhanced tissue features from CADxDE have great potential to improve lesion diagnosis performance.
- Open Access
- 10 August 2022
- Published by Elsevier in Radiology Case Reports
- Vol. 17 (10) , 3859-3862
Mediastinal extraosseous chordoma in a teenager: Diagnosis by ultrasound-guided percutaneous biopsy
- 10 August 2022
- Published by Elsevier in Radiology Case Reports
- Vol. 17 (10) , 3859-3862
Open AccessMediastinal extraosseous chordoma in a teenager: Diagnosis by ultrasound-guided percutaneous biopsy
- 30 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (11) , 3129-3139
Machine Learned Texture Prior From Full-Dose CT Database via Multi-Modality Feature Selection for Bayesian Reconstruction of Low-Dose CT
In our earlier study, we proposed a regional Markov random field type tissue-specific texture prior from previous full-dose computed tomography (FdCT) scan for current low-dose CT (LdCT) imaging, which showed clinical benefits through task-based evaluation. Nevertheless, two assumptions were made for early study. One assumption is that the center pixel has a linear relationship with its nearby neighbors and the other is previous FdCT scans of the same subject are available. To eliminate the two assumptions, we proposed a database assisted end-to-end LdCT reconstruction framework which includes a deep learning texture prior model and a multi-modality feature based candidate selection model. A convolutional neural network-based texture prior is proposed to eliminate the linear relationship assumption. And for scenarios in which the concerned subject has no previous FdCT scans, we propose to select one proper prior candidate from the FdCT database using multi-modality features. Features from three modalities are used including the subjects’ physiological factors, the CT scan protocol, and a novel feature named Lung Mark which is deliberately proposed to reflect the z-axial property of human anatomy. Moreover, a majority vote strategy is designed to overcome the noise effect from LdCT scans. Experimental results showed the effectiveness of Lung Mark. The selection model has accuracy of 84% testing on 1,470 images from 49 subjects. The learned texture prior from FdCT database provided reconstruction comparable to the subjects having corresponding FdCT. This study demonstrated the feasibility of bringing clinically relevant textures from available FdCT database to perform Bayesian reconstruction of any current LdCT scan.
- 30 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 42 (11) , 3129-3139
Machine Learned Texture Prior From Full-Dose CT Database via Multi-Modality Feature Selection for Bayesian Reconstruction of Low-Dose CT
In our earlier study, we proposed a regional Markov random field type tissue-specific texture prior from previous full-dose computed tomography (FdCT) scan for current low-dose CT (LdCT) imaging, which showed clinical benefits through task-based evaluation. Nevertheless, two assumptions were made for early study. One assumption is that the center pixel has a linear relationship with its nearby neighbors and the other is previous FdCT scans of the same subject are available. To eliminate the two assumptions, we proposed a database assisted end-to-end LdCT reconstruction framework which includes a deep learning texture prior model and a multi-modality feature based candidate selection model. A convolutional neural network-based texture prior is proposed to eliminate the linear relationship assumption. And for scenarios in which the concerned subject has no previous FdCT scans, we propose to select one proper prior candidate from the FdCT database using multi-modality features. Features from three modalities are used including the subjects’ physiological factors, the CT scan protocol, and a novel feature named Lung Mark which is deliberately proposed to reflect the z-axial property of human anatomy. Moreover, a majority vote strategy is designed to overcome the noise effect from LdCT scans. Experimental results showed the effectiveness of Lung Mark. The selection model has accuracy of 84% testing on 1,470 images from 49 subjects. The learned texture prior from FdCT database provided reconstruction comparable to the subjects having corresponding FdCT. This study demonstrated the feasibility of bringing clinically relevant textures from available FdCT database to perform Bayesian reconstruction of any current LdCT scan.
- 1 September 2021
- Published by Elsevier in Journal of Surgical Research
- Vol. 265, 86-94
Trends in Blunt Splenic Injury Management: The Rise of Splenic Artery Embolization
- 1 September 2021
- Published by Elsevier in Journal of Surgical Research
- Vol. 265, 86-94
Trends in Blunt Splenic Injury Management: The Rise of Splenic Artery Embolization
- 25 February 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (03) , 032502-15
Constructing a tissue-specific texture prior by machine learning from previous full-dose scan for Bayesian reconstruction of current ultralow-dose CT images
Purpose: Bayesian theory provides a sound framework for ultralow-dose computed tomography (ULdCT) image reconstruction with two terms for modeling the data statistical property and incorporating a priori knowledge for the image that is to be reconstructed. We investigate the feasibility of using a machine learning (ML) strategy, particularly the convolutional neural network (CNN), to construct a tissue-specific texture prior from previous full-dose computed tomography. Approach: Our study constructs four tissue-specific texture priors, corresponding with lung, bone, fat, and muscle, and integrates the prior with the prelog shift Poisson (SP) data property for Bayesian reconstruction of ULdCT images. The Bayesian reconstruction was implemented by an algorithm called SP-CNN-T and compared with our previous Markov random field (MRF)-based tissue-specific texture prior algorithm called SP-MRF-T. Results: In addition to conventional quantitative measures, mean squared error and peak signal-to-noise ratio, structure similarity index, feature similarity, and texture Haralick features were used to measure the performance difference between SP-CNN-T and SP-MRF-T algorithms in terms of the structure and tissue texture preservation, demonstrating the feasibility and the potential of the investigated ML approach. Conclusions: Both training performance and image reconstruction results showed the feasibility of constructing CNN texture prior model and the potential of improving the structure preservation of the nodule comparing to our previous regional tissue-specific MRF texture prior model.
- 25 February 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (03) , 032502-15
Constructing a tissue-specific texture prior by machine learning from previous full-dose scan for Bayesian reconstruction of current ultralow-dose CT images
Purpose: Bayesian theory provides a sound framework for ultralow-dose computed tomography (ULdCT) image reconstruction with two terms for modeling the data statistical property and incorporating a priori knowledge for the image that is to be reconstructed. We investigate the feasibility of using a machine learning (ML) strategy, particularly the convolutional neural network (CNN), to construct a tissue-specific texture prior from previous full-dose computed tomography. Approach: Our study constructs four tissue-specific texture priors, corresponding with lung, bone, fat, and muscle, and integrates the prior with the prelog shift Poisson (SP) data property for Bayesian reconstruction of ULdCT images. The Bayesian reconstruction was implemented by an algorithm called SP-CNN-T and compared with our previous Markov random field (MRF)-based tissue-specific texture prior algorithm called SP-MRF-T. Results: In addition to conventional quantitative measures, mean squared error and peak signal-to-noise ratio, structure similarity index, feature similarity, and texture Haralick features were used to measure the performance difference between SP-CNN-T and SP-MRF-T algorithms in terms of the structure and tissue texture preservation, demonstrating the feasibility and the potential of the investigated ML approach. Conclusions: Both training performance and image reconstruction results showed the feasibility of constructing CNN texture prior model and the potential of improving the structure preservation of the nodule comparing to our previous regional tissue-specific MRF texture prior model.
- Open Access
- 1 January 2017
- Published by SAGE Publications in Health Services Research and Managerial Epidemiology
- Vol. 4
2005 to 2014 CT and MRI Utilization Trends in the Context of a Nondenial Prior Authorization Program
Purpose: Reducing unnecessary testing may benefit patients, as some computed tomography (CT) and magnetic resonance imaging (MRI) expose patients to contrast, and all CTs expose patients to radiation. This observational study with historical controls assessed shifts in CT and MRI utilization over a 9-year period after a private health insurer’s implementation of a nondenial, consultative prior authorization program. Methods/Materials: Normalized rates of exams per 1000 person-years were plotted over 2005 to 2014 for people with commercial and Medicare Advantage health plans in the San Antonio market, with 2005 utilization set as the baseline. The program was implemented at the start of 2006. Computed tomography and MRI utilization changes were compared with contemporaneous changes in low-tech plain film and ultrasound utilization. Results: Growth in high-tech imaging utilization decelerated or reversed during the period. In 2006, CT utilization dropped to between 76% and 90% of what it had been in 2005, depending on the plan. In 2014, it was between 52% and 88% of its initial level. MRI utilization declined to between 86% and 94% of its initial level in 2006, and then to between 50% and 75% in 2014. Ultrasound utilization was greater in 2014 than in 2005 for some plans. Plain film utilization declined between 2005 and 2014 for all plans. Conclusion: There was an immediate and sustained decline in CT and MRI utilization after the introduction of the program. While many factors may have impacted the long-term trends, the mixed trends in low-tech imaging suggest that a decline in low-tech imaging was not responsible for the decline in CT and MRI utilization.
- 1 January 2017
- Published by SAGE Publications in Health Services Research and Managerial Epidemiology
- Vol. 4
Open Access2005 to 2014 CT and MRI Utilization Trends in the Context of a Nondenial Prior Authorization Program
Purpose: Reducing unnecessary testing may benefit patients, as some computed tomography (CT) and magnetic resonance imaging (MRI) expose patients to contrast, and all CTs expose patients to radiation. This observational study with historical controls assessed shifts in CT and MRI utilization over a 9-year period after a private health insurer’s implementation of a nondenial, consultative prior authorization program. Methods/Materials: Normalized rates of exams per 1000 person-years were plotted over 2005 to 2014 for people with commercial and Medicare Advantage health plans in the San Antonio market, with 2005 utilization set as the baseline. The program was implemented at the start of 2006. Computed tomography and MRI utilization changes were compared with contemporaneous changes in low-tech plain film and ultrasound utilization. Results: Growth in high-tech imaging utilization decelerated or reversed during the period. In 2006, CT utilization dropped to between 76% and 90% of what it had been in 2005, depending on the plan. In 2014, it was between 52% and 88% of its initial level. MRI utilization declined to between 86% and 94% of its initial level in 2006, and then to between 50% and 75% in 2014. Ultrasound utilization was greater in 2014 than in 2005 for some plans. Plain film utilization declined between 2005 and 2014 for all plans. Conclusion: There was an immediate and sustained decline in CT and MRI utilization after the introduction of the program. While many factors may have impacted the long-term trends, the mixed trends in low-tech imaging suggest that a decline in low-tech imaging was not responsible for the decline in CT and MRI utilization.