Jean-Baptiste de Villeneuve Bargemon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jean-Baptiste de Villeneuve Bargemon has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
Charlotte Jaloux
Hand Surgery and Limb Reconstructive Surgery Department, La Timone Adult Hospital, Aix Marseille University, Marseille, France
13 shared publicationsMichel Levadoux
Hand, Wrist and Elbow Surgery, Saint Roch Private Hospital, Toulon, France
11 shared publicationsLucas Audiffret
Hand Surgery and Limb Reconstructive Surgery Timone Adult Hospital, Aix Marseille University Marseille France
9 shared publicationsCamille Brenac
8 shared publicationsLorenzo Merlini
International Wrist Center, Clinique Bizet, Institut de la Main Paris France
8 shared publicationsChristophe Mathoulin
International Wrist Center, Bizet Clinic, Paris, France
7 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by Wiley in Arthroscopy Techniques
- p. e70364
Arthroscopic Scapholunate Osseous Ligament Anchor‐Based Round‐Block Repair for Scapholunate Instability
Scapholunate instability remains difficult to treat, particularly in lesions involving detachment of the dorsal intercarpal ligament from the scaphoid. We describe the Scapholunate Osseous Ligament Anchor‐based Round‐block technique, an arthroscopic anchor‐based repair designed to reinsert and retension the dorsal capsuloligamentous complex. The procedure allows dynamic assessment of reduction and may be combined with additional palmar stabilization when needed. This modular technique may represent a useful arthroscopic option for selected patterns of scapholunate instability.
- 2 November 2026
- Published by Wiley in Arthroscopy Techniques
- p. e70364
Open AccessArthroscopic Scapholunate Osseous Ligament Anchor‐Based Round‐Block Repair for Scapholunate Instability
Scapholunate instability remains difficult to treat, particularly in lesions involving detachment of the dorsal intercarpal ligament from the scaphoid. We describe the Scapholunate Osseous Ligament Anchor‐based Round‐block technique, an arthroscopic anchor‐based repair designed to reinsert and retension the dorsal capsuloligamentous complex. The procedure allows dynamic assessment of reduction and may be combined with additional palmar stabilization when needed. This modular technique may represent a useful arthroscopic option for selected patterns of scapholunate instability.
- 17 September 2026
- Published by Wolters Kluwer Health in Techniques in Hand & Upper Extremity Surgery
- Vol. 30 (4)
Arthroscopic Radiolunate Fusion: Surgical Technique
Radiolunate (RL) fusion is a selective salvage procedure for focal post-traumatic radiolunate arthritis, designed to address an isolated radiolunate lesion while preserving the uninvolved wrist compartments. Compared with radioscapholunate fusion, isolated radiolunate fusion preserves the radioscaphoid articulation and may theoretically favor preservation of the dart-throwing motion. Technical descriptions of RL fusion remain limited, particularly for the arthroscopic approach. This article describes a stepwise arthroscopic technique based on precise identification of the radial scapholunate crest and the triangular fibrocartilage complex, controlled osteochondral preparation of the lunate fossa and proximal lunate, arthroscopic cancellous bone grafting, and percutaneous compression screw fixation. The aim of the procedure is to obtain a focused fusion while minimizing capsular disruption, preserving vascularity and ligamentous attachments, and facilitating postoperative recovery.
- 17 September 2026
- Published by Wolters Kluwer Health in Techniques in Hand & Upper Extremity Surgery
- Vol. 30 (4)
Arthroscopic Radiolunate Fusion: Surgical Technique
Radiolunate (RL) fusion is a selective salvage procedure for focal post-traumatic radiolunate arthritis, designed to address an isolated radiolunate lesion while preserving the uninvolved wrist compartments. Compared with radioscapholunate fusion, isolated radiolunate fusion preserves the radioscaphoid articulation and may theoretically favor preservation of the dart-throwing motion. Technical descriptions of RL fusion remain limited, particularly for the arthroscopic approach. This article describes a stepwise arthroscopic technique based on precise identification of the radial scapholunate crest and the triangular fibrocartilage complex, controlled osteochondral preparation of the lunate fossa and proximal lunate, arthroscopic cancellous bone grafting, and percutaneous compression screw fixation. The aim of the procedure is to obtain a focused fusion while minimizing capsular disruption, preserving vascularity and ligamentous attachments, and facilitating postoperative recovery.
- Open Access
- 17 August 2026
- Published by Elsevier in Journal of Hand and Microsurgery
Long-term outcomes of SLIC 2 ligamentoplasty for chronic static scapholunate dissociation: a minimum 5-year follow-up study
- 17 August 2026
- Published by Elsevier in Journal of Hand and Microsurgery
Open AccessLong-term outcomes of SLIC 2 ligamentoplasty for chronic static scapholunate dissociation: a minimum 5-year follow-up study
- 27 July 2026
- Published by Elsevier in Journal of Hand and Microsurgery
- Vol. 18 (5)
Pisotriquetral synovial chondromatosis: a rare inflammatory presentation
- 27 July 2026
- Published by Elsevier in Journal of Hand and Microsurgery
- Vol. 18 (5)
Pisotriquetral synovial chondromatosis: a rare inflammatory presentation
- 1 July 2026
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
Tendon safety profiles of fragment-specific fixations of the distal radius extending beyond the watershed line
Introduction: The treatment of complex intra-articular fractures of the distal radius may require the use of ‘fragment specific’ plates potentially irritating the flexor tendons. Our hypothesis is that there may be different rates of tendon irritation depending on the level of projection (radial and/or ulnar) of the plate at the watershed line. We report our experience with a cohort of 113 patients comparing four different plates. Methods: We conducted a single-centre study with prospective inclusion of patients with distal radial fractures from May 2022 to March 2025. The primary objective was to evaluate the rate of tendon irritation according to the type of specific fixation used for intra-articular fractures. At the 6 month visit, an ultrasound was performed to assess the presence or absence of tendon irritation, along with a computed tomography scan to evaluate proper application of the plate to the bone. Results: Forty-two ulnar hook plates (Medartis and Newclip Technics), 31 extradistal plates (Newclip Technics), 21 adjustable anterior rim plates (Medartis) and 19 curved ‘babyfoot’ plates (Medartis) placed distal to the watershed line were used for the fixations. At 6 months, ultrasound revealed tendon irritation in nine cases involving hook plates, 15 involving extradistal plates, 10 involving babyfoot plates and none involving adjustable anterior rim plates. There was a significant difference in the frequency of tendon irritation between plate types ( p < 0.001). Conclusion: Our results suggest that specific, ulnar side fixation, ideally with an adjustable plate, may significantly reduce the risk of tendon irritation after complex distal radial articular fractures. Level of evidence: III
- 1 July 2026
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
Tendon safety profiles of fragment-specific fixations of the distal radius extending beyond the watershed line
Introduction: The treatment of complex intra-articular fractures of the distal radius may require the use of ‘fragment specific’ plates potentially irritating the flexor tendons. Our hypothesis is that there may be different rates of tendon irritation depending on the level of projection (radial and/or ulnar) of the plate at the watershed line. We report our experience with a cohort of 113 patients comparing four different plates. Methods: We conducted a single-centre study with prospective inclusion of patients with distal radial fractures from May 2022 to March 2025. The primary objective was to evaluate the rate of tendon irritation according to the type of specific fixation used for intra-articular fractures. At the 6 month visit, an ultrasound was performed to assess the presence or absence of tendon irritation, along with a computed tomography scan to evaluate proper application of the plate to the bone. Results: Forty-two ulnar hook plates (Medartis and Newclip Technics), 31 extradistal plates (Newclip Technics), 21 adjustable anterior rim plates (Medartis) and 19 curved ‘babyfoot’ plates (Medartis) placed distal to the watershed line were used for the fixations. At 6 months, ultrasound revealed tendon irritation in nine cases involving hook plates, 15 involving extradistal plates, 10 involving babyfoot plates and none involving adjustable anterior rim plates. There was a significant difference in the frequency of tendon irritation between plate types ( p < 0.001). Conclusion: Our results suggest that specific, ulnar side fixation, ideally with an adjustable plate, may significantly reduce the risk of tendon irritation after complex distal radial articular fractures. Level of evidence: III
- Open Access
- 31 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4250
Comparison of Radiographic and Ultrasound Imaging Techniques for Assessing the Scapholunate Interval in Healthy Individuals
Background/Objectives: Ultrasound (US) is a valuable tool in hand surgery because of its portability, low cost, and ability to provide noninvasive, real-time evaluation of soft tissue structures. However, it has not been widely assessed for measuring the scapholunate (SL) interval using dynamic stress views. This study aimed to determine whether ultrasound provides comparable measurements to radiography when evaluating the SL interval in healthy subjects. Methods: We analyzed 29 wrists from 29 individuals. Each wrist underwent dynamic stress maneuvers while the SL interval was measured with both radiography and US. The following views were obtained: neutral rotation, ulnar deviation, clenched fist, and a modified dynamic clenched fist view. The latter was performed by applying pressure on the head of the third metacarpal from distal to proximal. Results: The SL interval could be visualized in the clenched fist and ulnar deviation radiographic views, as well as in the modified dynamic clenched fist US view. Ultrasound in the neutral position produced measurements similar to those of traditional stress radiographs. The most pronounced changes in the SL interval occurred between neutral and dynamic views, whether assessed by radiography or US. There was no significant difference in the magnitude of interval change between the two imaging modalities. Conclusions: Ultrasound with dynamic stress maneuvers provided similar dynamic SL interval changes to stress radiographs in healthy individuals. A modified stress view using a slightly clenched fist and manual pressure on the third metacarpal head may offer hand surgeons a simple, real-time tool to noninvasively evaluate SL instability.
- 31 May 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (11) , 4250
Open AccessComparison of Radiographic and Ultrasound Imaging Techniques for Assessing the Scapholunate Interval in Healthy Individuals
Background/Objectives: Ultrasound (US) is a valuable tool in hand surgery because of its portability, low cost, and ability to provide noninvasive, real-time evaluation of soft tissue structures. However, it has not been widely assessed for measuring the scapholunate (SL) interval using dynamic stress views. This study aimed to determine whether ultrasound provides comparable measurements to radiography when evaluating the SL interval in healthy subjects. Methods: We analyzed 29 wrists from 29 individuals. Each wrist underwent dynamic stress maneuvers while the SL interval was measured with both radiography and US. The following views were obtained: neutral rotation, ulnar deviation, clenched fist, and a modified dynamic clenched fist view. The latter was performed by applying pressure on the head of the third metacarpal from distal to proximal. Results: The SL interval could be visualized in the clenched fist and ulnar deviation radiographic views, as well as in the modified dynamic clenched fist US view. Ultrasound in the neutral position produced measurements similar to those of traditional stress radiographs. The most pronounced changes in the SL interval occurred between neutral and dynamic views, whether assessed by radiography or US. There was no significant difference in the magnitude of interval change between the two imaging modalities. Conclusions: Ultrasound with dynamic stress maneuvers provided similar dynamic SL interval changes to stress radiographs in healthy individuals. A modified stress view using a slightly clenched fist and manual pressure on the third metacarpal head may offer hand surgeons a simple, real-time tool to noninvasively evaluate SL instability.
- 16 April 2026
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 51 (8) , 848-853
Interobserver Reliability of the Trampoline Test, Hook Test, and Suction Test in Arthroscopic Assessment of Triangular Fibrocartilage Complex Lesions
- 16 April 2026
- Published by Elsevier in The Journal of Hand Surgery
- Vol. 51 (8) , 848-853
Interobserver Reliability of the Trampoline Test, Hook Test, and Suction Test in Arthroscopic Assessment of Triangular Fibrocartilage Complex Lesions
- Open Access
- 12 April 2026
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 112 (5) , 104702
A proposed surgical strategy for complex articular distal radius fractures: The Marseille approach for radius salvage (MARS)
- 12 April 2026
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 112 (5) , 104702
Open AccessA proposed surgical strategy for complex articular distal radius fractures: The Marseille approach for radius salvage (MARS)
- Open Access
- 24 March 2026
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 45 (3) , 102644
Specific fixation beyond the watershed line for distal radius fractures: A comparative study
- 24 March 2026
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 45 (3) , 102644
Open AccessSpecific fixation beyond the watershed line for distal radius fractures: A comparative study
- Open Access
- 11 March 2026
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 112 (5) , 104652
Computed tomography–based predictors of ulnar-sided complications after distal radius fracture fixation
- 11 March 2026
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 112 (5) , 104652
Open AccessComputed tomography–based predictors of ulnar-sided complications after distal radius fracture fixation