Oleksii Semeniuk
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Oleksii Semeniuk has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Aisling Barry
Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON M5G 2C4, Canada
1 shared publication - Ali Hosni
Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Canada
1 shared publication Amanda Cherpak
Medical Physics Nova Scotia Health Halifax B3H 1V7 Canada
1 shared publication- Andrea Shessel
Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
1 shared publication - Cathy Carpino-Rocca
Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
1 shared publication - Edward Taylor
Princess Margaret Cancer Centre, University Health Network, Toronto, ON M5G 2M9, Canada
1 shared publication
Latest Publications
- Open Access
MRI-Guided Online Adaptive Stereotactic Body Radiation Therapy of Liver and Pancreas Tumors on an MR-Linac System
Purpose: To describe a comprehensive workflow for MRI-guided online adaptive stereotactic body radiation therapy (SBRT) specific to upper gastrointestinal cancer patients with abdominal compression on a 1.5T MR-Linac system. Additionally, we discuss the workflow’s clinical feasibility and early experience in the case of 16 liver and pancreas patients. Methods: Eleven patients with liver cancer and five patients with pancreas cancer were treated with online adaptive MRI-guidance under abdominal compression. Two liver patients received single-fraction treatments; the remainder plus all pancreas cancer patients received five fractions. A total of 65 treatment sessions were investigated to provide analytics relevant to the online adaptive processes. The quantification of target and organ motion as well as definition and validation of internal target volume (ITV) margins were performed via multi-contrast imaging provided by three different 2D cine sequences. The plan generation was driven by full re-optimization strategies and using T2-weighted 3D image series acquired by means of a respiratory-triggered exhale phase or a time-averaged imaging protocol. As a pre-requisite for the clinical development of the procedure, the image quality was thoroughly investigated via phantom measurements and numerical simulations specific to upper abdominal sites. The delivery of the online adaptive treatments was facilitated by real-time monitoring with 2D cine imaging. Results: Liver 1-fraction and 5-fraction online adaptive session time were on average 80 and 67.5 min, respectively. The total session length varied between 70–90 min for a single fraction and 55–90 min for five fractions. The pancreas sessions were 54–85 min long with an average session time of 68.2 min. Target visualization on the 2D cine image data varied per patient, with at least one of the 2D cine sequences providing sufficient contrast to confidently identify its location and confirm reproducibility of ITV margins. The mean/range of absolute and relative dose values for all treatment sessions evaluated with ArcCheck were 90.6/80.9–96.1% and 99/95.4–100%, respectively. Conclusion: MR-guidance is feasible for liver and pancreas tumors when abdominal compression is used to reduce organ motion, improve imaging quality, and achieve a robust intra- and inter-fraction patient setup. However, the treatment length is significantly longer than for the conventional linac, and patient compliance is paramount for the successful completion of the treatment. Opportunities for reducing the online adaptive session time should be explored. As the next steps, dose-of-the-day and dose accumulation analysis and tools are needed to enhance the workflow and to help further refine the online re-planning processes.
Open AccessMRI-Guided Online Adaptive Stereotactic Body Radiation Therapy of Liver and Pancreas Tumors on an MR-Linac System
Purpose: To describe a comprehensive workflow for MRI-guided online adaptive stereotactic body radiation therapy (SBRT) specific to upper gastrointestinal cancer patients with abdominal compression on a 1.5T MR-Linac system. Additionally, we discuss the workflow’s clinical feasibility and early experience in the case of 16 liver and pancreas patients. Methods: Eleven patients with liver cancer and five patients with pancreas cancer were treated with online adaptive MRI-guidance under abdominal compression. Two liver patients received single-fraction treatments; the remainder plus all pancreas cancer patients received five fractions. A total of 65 treatment sessions were investigated to provide analytics relevant to the online adaptive processes. The quantification of target and organ motion as well as definition and validation of internal target volume (ITV) margins were performed via multi-contrast imaging provided by three different 2D cine sequences. The plan generation was driven by full re-optimization strategies and using T2-weighted 3D image series acquired by means of a respiratory-triggered exhale phase or a time-averaged imaging protocol. As a pre-requisite for the clinical development of the procedure, the image quality was thoroughly investigated via phantom measurements and numerical simulations specific to upper abdominal sites. The delivery of the online adaptive treatments was facilitated by real-time monitoring with 2D cine imaging. Results: Liver 1-fraction and 5-fraction online adaptive session time were on average 80 and 67.5 min, respectively. The total session length varied between 70–90 min for a single fraction and 55–90 min for five fractions. The pancreas sessions were 54–85 min long with an average session time of 68.2 min. Target visualization on the 2D cine image data varied per patient, with at least one of the 2D cine sequences providing sufficient contrast to confidently identify its location and confirm reproducibility of ITV margins. The mean/range of absolute and relative dose values for all treatment sessions evaluated with ArcCheck were 90.6/80.9–96.1% and 99/95.4–100%, respectively. Conclusion: MR-guidance is feasible for liver and pancreas tumors when abdominal compression is used to reduce organ motion, improve imaging quality, and achieve a robust intra- and inter-fraction patient setup. However, the treatment length is significantly longer than for the conventional linac, and patient compliance is paramount for the successful completion of the treatment. Opportunities for reducing the online adaptive session time should be explored. As the next steps, dose-of-the-day and dose accumulation analysis and tools are needed to enhance the workflow and to help further refine the online re-planning processes.
- 20 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (7) , 4053-4063
Design and evaluation of 3D printable patient‐specific applicators for gynecologic HDR brachytherapy
Purpose: The purpose of this study is to improve dose distribution and organ‐at‐risk sparing during gynecologic HDR brachytherapy with patient‐specific applicators. The majority of applicators used today are generic in design and do not allow for dose modulation for patient‐specific shaping of dose distributions. Their performance might be adjusted with commercially available wedge shields; however, this provides dose modulation in the orthogonal plane only and does not allow for variation along the length of the applicator. Generic applicators are available only in standard sizes and geometries, and provide suboptimal patient fit with limited dose modulation.Methods: In this paper we use Monte Carlo modeling for comprehensive characterization of radiologic properties of various 3D printable biocompatible and sterilizable materials with comparison to water. Based on these results, we choose the optimal set of materials for a patient‐specific applicator. We develop a novel method to design the patient‐specific applicator without incurring a significant increase in treatment time or changes to clinical workflow. Finally, using an example of two selected vaginal cancers, we compare the performance of patient‐specific and water‐equivalent applicators in terms of target coverage and rectum sparing.Results: In the energy range from 1 MeV to 4 MeV, all materials have similar attenuation coefficients. In the range from ~2 keV to 1 MeV and above 4 MeV, tungsten‐polylactic acid composite (WPLA) was seen to have the highest attenuation coefficient. The dose distribution of the water‐equivalent applicator was found to be symmetric about its central axis. At the same time patient‐specific shielded applicators exhibit well‐modulated dose distributions. Their isodose lines are seen to spread radially into the patient, while merging close to the applicator surface, where WPLA shielding has been applied.Conclusions: The patient‐specific cylinders provide comparable dose to the target, while offering advanced healthy tissue sparing, not achievable with the generic design.
- 20 April 2021
- Published by Wiley in Medical Physics
- Vol. 48 (7) , 4053-4063
Design and evaluation of 3D printable patient‐specific applicators for gynecologic HDR brachytherapy
Purpose: The purpose of this study is to improve dose distribution and organ‐at‐risk sparing during gynecologic HDR brachytherapy with patient‐specific applicators. The majority of applicators used today are generic in design and do not allow for dose modulation for patient‐specific shaping of dose distributions. Their performance might be adjusted with commercially available wedge shields; however, this provides dose modulation in the orthogonal plane only and does not allow for variation along the length of the applicator. Generic applicators are available only in standard sizes and geometries, and provide suboptimal patient fit with limited dose modulation.Methods: In this paper we use Monte Carlo modeling for comprehensive characterization of radiologic properties of various 3D printable biocompatible and sterilizable materials with comparison to water. Based on these results, we choose the optimal set of materials for a patient‐specific applicator. We develop a novel method to design the patient‐specific applicator without incurring a significant increase in treatment time or changes to clinical workflow. Finally, using an example of two selected vaginal cancers, we compare the performance of patient‐specific and water‐equivalent applicators in terms of target coverage and rectum sparing.Results: In the energy range from 1 MeV to 4 MeV, all materials have similar attenuation coefficients. In the range from ~2 keV to 1 MeV and above 4 MeV, tungsten‐polylactic acid composite (WPLA) was seen to have the highest attenuation coefficient. The dose distribution of the water‐equivalent applicator was found to be symmetric about its central axis. At the same time patient‐specific shielded applicators exhibit well‐modulated dose distributions. Their isodose lines are seen to spread radially into the patient, while merging close to the applicator surface, where WPLA shielding has been applied.Conclusions: The patient‐specific cylinders provide comparable dose to the target, while offering advanced healthy tissue sparing, not achievable with the generic design.