Hongru Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hongru Zhang has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Hongshun Liu
School of Electrical Engineering, Shandong University, Jinan 250061, China
4 shared publications - Qingquan Li
School of Electrical Engineering, Shandong University, Jinan, China
3 shared publications - Dongxin He
Shandong Provincial Key Laboratory of UHV Transmission Technology and Equipment, School of Electrical Engineering, Shandong University, Jinan, China
2 shared publications - Jiaxiang Sun
Department of Clinical Laboratory, Peoples Hospital of Deyang City, Deyang, China
2 shared publications - Kaining Hou
Shandong Provincial Key Laboratory of UHV Transmission Technology and Equipment, School of Electrical Engineering Shandong University Jinan China
2 shared publications Ali Abdo
1 shared publication
Latest Publications
- Open Access
- 1 September 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 9 (1) , 105-116
A method for detecting two‐dimensional plane stress distribution in basin‐type insulator based on critically refracted longitudinal wave
Basin‐type insulator often has small cracks due to stress concentration. The current method cannot accurately reflect the stress condition of the insulator to find the stress concentration areas. To solve these problems, a method for detecting two‐dimensional plane stress ( δ 1 and δ 2 ) within different depth ranges in a basin‐type insulator is proposed based on critically refracted longitudinal (LCR) wave. First, the acoustoelastic equation characterising the relationship between the variation of LCR wave propagation time and the plane stress was derived. Next, the propagation characteristics of LCR wave in epoxy resin samples were investigated. Then, the stress distribution within different depth ranges of the insulator subjected to hydraulic load was measured using the proposed method, including direction ( θ ), δ 1 and δ 2 . The results show that the magnitude of the stress alone cannot accurately characterise the stress state. Points with equal distances to the centre have similar stress magnitudes, but their directions are not the same. With increasing depth, θ remains essentially unchanged at the same location, while δ 1 and δ 2 decrease, and the rate of decrease varies at different locations. Comparing the measured and simulated data, the results showed that they were in good agreement, and the maximum errors of stress value and θ were 0.69 MPa and 2.97°, respectively, which confirmed the feasibility and accuracy of the stress detection in the proposed method.
- 1 September 2023
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 9 (1) , 105-116
Open AccessA method for detecting two‐dimensional plane stress distribution in basin‐type insulator based on critically refracted longitudinal wave
Basin‐type insulator often has small cracks due to stress concentration. The current method cannot accurately reflect the stress condition of the insulator to find the stress concentration areas. To solve these problems, a method for detecting two‐dimensional plane stress ( δ 1 and δ 2 ) within different depth ranges in a basin‐type insulator is proposed based on critically refracted longitudinal (LCR) wave. First, the acoustoelastic equation characterising the relationship between the variation of LCR wave propagation time and the plane stress was derived. Next, the propagation characteristics of LCR wave in epoxy resin samples were investigated. Then, the stress distribution within different depth ranges of the insulator subjected to hydraulic load was measured using the proposed method, including direction ( θ ), δ 1 and δ 2 . The results show that the magnitude of the stress alone cannot accurately characterise the stress state. Points with equal distances to the centre have similar stress magnitudes, but their directions are not the same. With increasing depth, θ remains essentially unchanged at the same location, while δ 1 and δ 2 decrease, and the rate of decrease varies at different locations. Comparing the measured and simulated data, the results showed that they were in good agreement, and the maximum errors of stress value and θ were 0.69 MPa and 2.97°, respectively, which confirmed the feasibility and accuracy of the stress detection in the proposed method.
- 1 November 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 200
A new model of faults classification in power transformers based on data optimization method
- 1 November 2021
- Published by Elsevier in Electric Power Systems Research
- Vol. 200
A new model of faults classification in power transformers based on data optimization method
- Open Access
- 16 April 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (3) , 510-522
Improved information entropy weighted vague support vector machine method for transformer fault diagnosis
A combined model based on improved information entropy and vague support vector machine (IVSVM) is introduced into transformer fault diagnosis using dissolved gas analysis in oil (DGA). The improved information entropy method is used to obtain the weights of each gas and to weight the raw data, and the processed training data and the corresponding fault types are inputted into the vague support vector machine (VSVM) model to obtain classifiers. Firstly, the training data are weighted by the improved information entropy method to discretise the original data from the mixed state for subsequent classifier training. Then, the vague set divides the events into true, false and unknown factors, which can optimise the sub‐interface of SVM and improve the accuracy of the boundary point classification. Finally, fault data from the literature and actual collections are selected for training and testing. By comparing with the widely used ratio method and artificial intelligence method, it can be concluded that the method described herein can effectively improve the accuracy of fault diagnosis. The result shows that this method has better applicability when facing actual fault type classification with higher data similarity.
- 16 April 2021
- Published by Institution of Engineering and Technology (IET) in High Voltage
- Vol. 7 (3) , 510-522
Open AccessImproved information entropy weighted vague support vector machine method for transformer fault diagnosis
A combined model based on improved information entropy and vague support vector machine (IVSVM) is introduced into transformer fault diagnosis using dissolved gas analysis in oil (DGA). The improved information entropy method is used to obtain the weights of each gas and to weight the raw data, and the processed training data and the corresponding fault types are inputted into the vague support vector machine (VSVM) model to obtain classifiers. Firstly, the training data are weighted by the improved information entropy method to discretise the original data from the mixed state for subsequent classifier training. Then, the vague set divides the events into true, false and unknown factors, which can optimise the sub‐interface of SVM and improve the accuracy of the boundary point classification. Finally, fault data from the literature and actual collections are selected for training and testing. By comparing with the widely used ratio method and artificial intelligence method, it can be concluded that the method described herein can effectively improve the accuracy of fault diagnosis. The result shows that this method has better applicability when facing actual fault type classification with higher data similarity.
- Open Access
- 1 December 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (12) , 125102
Wettability behavior and anti-icing property of superhydrophobic coating on HTV silicone rubber
Composite insulators, which use high temperature vulcanized (HTV) silicone rubber as shed material, are widely applied in transmission lines. Ice accumulation on their surfaces may inflict flashover accident and even massive power outage. In this study, a superhydrophobic (SH) coating on HTV silicone rubber was fabricated by the sol–gel process combined with the plasma jet treatment method. It was found that the as-prepared SH coating exhibited prominent superhydrophobicity and an excellent self-cleaning property with a water contact angle of 160.15°, a contact angle hysteresis of 0.60°, a sliding angle of 1.8°, and a surface free energy of 0.1421 mN/m. The anti-icing behavior of water droplets on the as-prepared SH coating surface was investigated at a low temperature of −30 °C and compared with that of the HTV silicone rubber surface. The results indicated that the freezing time on the SH coating was postponed obviously and was as long as 150 s. The SH coating surface exhibited about 5.6 times delay in freezing at −30 °C compared with the HTV silicone rubber surface. Furthermore, heterogeneous nucleation theory and heat transfer theory were introduced to explain the difference in freezing time between the as-prepared SH coating and HTV silicone rubber. It could be concluded that the SH coating had a large nucleation free energy barrier and a low heat transfer rate between the droplet and the surface and, thus, was able to effectively delay the freezing time.
- 1 December 2020
- Published by AIP Publishing in AIP Advances
- Vol. 10 (12) , 125102
Open AccessWettability behavior and anti-icing property of superhydrophobic coating on HTV silicone rubber
Composite insulators, which use high temperature vulcanized (HTV) silicone rubber as shed material, are widely applied in transmission lines. Ice accumulation on their surfaces may inflict flashover accident and even massive power outage. In this study, a superhydrophobic (SH) coating on HTV silicone rubber was fabricated by the sol–gel process combined with the plasma jet treatment method. It was found that the as-prepared SH coating exhibited prominent superhydrophobicity and an excellent self-cleaning property with a water contact angle of 160.15°, a contact angle hysteresis of 0.60°, a sliding angle of 1.8°, and a surface free energy of 0.1421 mN/m. The anti-icing behavior of water droplets on the as-prepared SH coating surface was investigated at a low temperature of −30 °C and compared with that of the HTV silicone rubber surface. The results indicated that the freezing time on the SH coating was postponed obviously and was as long as 150 s. The SH coating surface exhibited about 5.6 times delay in freezing at −30 °C compared with the HTV silicone rubber surface. Furthermore, heterogeneous nucleation theory and heat transfer theory were introduced to explain the difference in freezing time between the as-prepared SH coating and HTV silicone rubber. It could be concluded that the SH coating had a large nucleation free energy barrier and a low heat transfer rate between the droplet and the surface and, thus, was able to effectively delay the freezing time.