Anjali Seth
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Anjali Seth has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Claudia Ctortecka
Northwestern University
2 shared publications Brian Boyle
Broad Institute of MIT and Harvard
1 shared publicationC. M. Wilcox
Orlando Health Digestive Health Institute, Orlando, United States of America
1 shared publicationDavid Hartlmayr
Research Institute of Molecular Pathology (IMP), Vienna Biocenter (VBC), Campus-Vienna-Biocenter 1, 1030 Vienna, Austria
1 shared publication- Deepak R. Mani
Broad Institute of MIT and Harvard, Cambridge, MA 02142, USA
1 shared publication - Guilhem Tourniaire
Smart Holograms Ltd., Cambridge, United Kingdom
1 shared publication
Latest Publications
- Open Access
Automated single-cell proteomics providing sufficient proteome depth to study complex biology beyond cell type classifications
Mass spectrometry (MS)-based single-cell proteomics (SCP) has gained massive attention as a viable complement to other single cell approaches. The rapid technological and computational advances in the field have pushed the boundaries of sensitivity and throughput. However, reproducible quantification of thousands of proteins within a single cell at reasonable proteome depth to characterize biological phenomena remains a challenge. To address some of those limitations we present a combination of fully automated single cell sample preparation utilizing a dedicated chip within the picolitre dispensing robot, the cellenONE. The proteoCHIP EVO 96 can be directly interfaced with the Evosep One chromatographic system for in-line desalting and highly reproducible separation with a throughput of 80 samples per day. This, in combination with the Bruker timsTOF MS instruments, demonstrates double the identifications without manual sample handling. Moreover, relative to standard high-performance liquid chromatography, the Evosep One separation provides further 2-fold improvement in protein identifications. The implementation of the newest generation timsTOF Ultra with our proteoCHIP EVO 96-based sample preparation workflow reproducibly identifies up to 4,000 proteins per single HEK-293T without a carrier or match-between runs. Our current SCP depth spans over 4 orders of magnitude and identifies over 50 biologically relevant ubiquitin ligases. We complement our highly reproducible single-cell proteomics workflow to profile hundreds of lipopolysaccharide (LPS)-perturbed THP-1 cells and identified key regulatory proteins involved in interleukin and interferon signaling. This study demonstrates that the proteoCHIP EVO 96-based SCP sample preparation with the timsTOF Ultra provides sufficient proteome depth to study complex biology beyond cell-type classifications.
Open AccessAutomated single-cell proteomics providing sufficient proteome depth to study complex biology beyond cell type classifications
Mass spectrometry (MS)-based single-cell proteomics (SCP) has gained massive attention as a viable complement to other single cell approaches. The rapid technological and computational advances in the field have pushed the boundaries of sensitivity and throughput. However, reproducible quantification of thousands of proteins within a single cell at reasonable proteome depth to characterize biological phenomena remains a challenge. To address some of those limitations we present a combination of fully automated single cell sample preparation utilizing a dedicated chip within the picolitre dispensing robot, the cellenONE. The proteoCHIP EVO 96 can be directly interfaced with the Evosep One chromatographic system for in-line desalting and highly reproducible separation with a throughput of 80 samples per day. This, in combination with the Bruker timsTOF MS instruments, demonstrates double the identifications without manual sample handling. Moreover, relative to standard high-performance liquid chromatography, the Evosep One separation provides further 2-fold improvement in protein identifications. The implementation of the newest generation timsTOF Ultra with our proteoCHIP EVO 96-based sample preparation workflow reproducibly identifies up to 4,000 proteins per single HEK-293T without a carrier or match-between runs. Our current SCP depth spans over 4 orders of magnitude and identifies over 50 biologically relevant ubiquitin ligases. We complement our highly reproducible single-cell proteomics workflow to profile hundreds of lipopolysaccharide (LPS)-perturbed THP-1 cells and identified key regulatory proteins involved in interleukin and interferon signaling. This study demonstrates that the proteoCHIP EVO 96-based SCP sample preparation with the timsTOF Ultra provides sufficient proteome depth to study complex biology beyond cell-type classifications.
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S25
Description of technique for EUS-guided tissue acquisition in pancreatic cancer for comprehensive molecular profiling: Results of a randomized trial
Aims As theoretically actionable genomic lesions are found in 50% of pancreatic cancers which can impact clinical management in up to 30% of patients, there is increased focus on molecular profiling. Although EUS-FNB is an established method for pathological diagnosis in pancreatic cancers, technique for comprehensive molecular profiling (CMP) has not been described. Methods Patients with pancreatic adenocarcinoma on ROSE at EUS were randomized to 2 or 3 dedicated FNB passes for CMP. Tissue was procured using 22G Franseen needle adopting fanning technique and stylet-retraction maneuver. Genomic DNA and total RNA were extracted from cell blocks. Next-generation sequencing was performed for analyzing 69 gene DNA mutations and 53 RNA somatic oncogenic gene fusions. Main outcome measure was specimens in which adequate DNA and RNA were extracted for CMP. Results 33 patients were randomized to 2(n=17) or 3(n=16) FNB passes. While sufficient DNA was extracted from all 33 cell blocks, adequate RNA was extracted from 93.8% in 3-pass vs. 94.1% in 2-pass cohort (p=0.99). There was no significant difference in mean DNA concentration (2-pass 10.7[SD 7.1] vs. 3-pass 7.9ng/ul[SD 4.4]; p=0.19) or RNA (2-pass 37.1[SD 26.5] vs. 3-pass 28.9ug/ul[SD 13.2]; p=0.29) between groups. While somatic oncogene RNA fusion (LDAH-ETV1) predictive of metastatic disease was identified in 1, DNA mutations were identified in all 33 pts (inc. 1 BRCA1 for Oxaliplatin based chemotherapy) ([Table 1]). Conclusions Specimens of adequate quantity and of high quality for CMP in pancreatic cancer can be procured in nearly 95% of patients by performing 2 dedicated passes using 22G Franseen needle, adopting fanning maneuver and stylet-retraction technique. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- 14 April 2023
- Published by Georg Thieme Verlag KG in Endoscopy
- Vol. 55 (S 02) , S25
Description of technique for EUS-guided tissue acquisition in pancreatic cancer for comprehensive molecular profiling: Results of a randomized trial
Aims As theoretically actionable genomic lesions are found in 50% of pancreatic cancers which can impact clinical management in up to 30% of patients, there is increased focus on molecular profiling. Although EUS-FNB is an established method for pathological diagnosis in pancreatic cancers, technique for comprehensive molecular profiling (CMP) has not been described. Methods Patients with pancreatic adenocarcinoma on ROSE at EUS were randomized to 2 or 3 dedicated FNB passes for CMP. Tissue was procured using 22G Franseen needle adopting fanning technique and stylet-retraction maneuver. Genomic DNA and total RNA were extracted from cell blocks. Next-generation sequencing was performed for analyzing 69 gene DNA mutations and 53 RNA somatic oncogenic gene fusions. Main outcome measure was specimens in which adequate DNA and RNA were extracted for CMP. Results 33 patients were randomized to 2(n=17) or 3(n=16) FNB passes. While sufficient DNA was extracted from all 33 cell blocks, adequate RNA was extracted from 93.8% in 3-pass vs. 94.1% in 2-pass cohort (p=0.99). There was no significant difference in mean DNA concentration (2-pass 10.7[SD 7.1] vs. 3-pass 7.9ng/ul[SD 4.4]; p=0.19) or RNA (2-pass 37.1[SD 26.5] vs. 3-pass 28.9ug/ul[SD 13.2]; p=0.29) between groups. While somatic oncogene RNA fusion (LDAH-ETV1) predictive of metastatic disease was identified in 1, DNA mutations were identified in all 33 pts (inc. 1 BRCA1 for Oxaliplatin based chemotherapy) ([Table 1]). Conclusions Specimens of adequate quantity and of high quality for CMP in pancreatic cancer can be procured in nearly 95% of patients by performing 2 dedicated passes using 22G Franseen needle, adopting fanning maneuver and stylet-retraction technique. Article published online: 14 April 2023 © 2023. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany
- Open Access
An automated workflow for multiplexed single-cell proteomics sample preparation at unprecedented sensitivity
The analysis of single-cell proteomes has recently become a viable complement to transcriptomics and genomics studies. Proteins are the primary driver of cellular functionality and mRNA levels are often an unreliable proxy of such. Therefore, the global analysis of the proteome is essential to study cellular identities. Multiplexed and label-free mass spectrometry-based approaches with single-cell resolution have lately attributed surprising heterogeneity to presumed homogenous cell populations. Even though specialized experimental designs and instrumentation have demonstrated remarkable advances, the efficient sample preparation of single cells still lag. Here, we introduce the proteoCHIP, a universal option for single-cell proteomics sample preparation at surprising sensitivity and throughput. The automated processing using a commercial system combining single-cell isolation and picoliter dispensing, the cellenONE ® , reduces final sample volumes to low nanoliters submerged in a hexadecane layer simultaneously eliminating error-prone manual sample handling and overcoming evaporation. The specialized proteoCHIP design allows direct injection of single cells via a standard autosampler resulting in around 1,500 protein groups per analytical run at remarkable reporter ion signal to noise while reducing or eliminating the carrier proteome. We identified close to 2,600 proteins across 170 multiplexed single cells from two highly similar human cell types. This dedicated loss-less workflow allows distinguishing in vitro co-differentiated cell types of self-organizing cardiac organoids based on indicative markers across 150 single cells. In-depth characterization revealed enhanced cellular motility of cardiac endothelial cells and sarcomere organization in cardiomyocytes. Our versatile and automated sample preparation has not only proven to be easily adaptable but is also sufficiently sensitive to drive biological applications of single-cell proteomics.
Open AccessAn automated workflow for multiplexed single-cell proteomics sample preparation at unprecedented sensitivity
The analysis of single-cell proteomes has recently become a viable complement to transcriptomics and genomics studies. Proteins are the primary driver of cellular functionality and mRNA levels are often an unreliable proxy of such. Therefore, the global analysis of the proteome is essential to study cellular identities. Multiplexed and label-free mass spectrometry-based approaches with single-cell resolution have lately attributed surprising heterogeneity to presumed homogenous cell populations. Even though specialized experimental designs and instrumentation have demonstrated remarkable advances, the efficient sample preparation of single cells still lag. Here, we introduce the proteoCHIP, a universal option for single-cell proteomics sample preparation at surprising sensitivity and throughput. The automated processing using a commercial system combining single-cell isolation and picoliter dispensing, the cellenONE ® , reduces final sample volumes to low nanoliters submerged in a hexadecane layer simultaneously eliminating error-prone manual sample handling and overcoming evaporation. The specialized proteoCHIP design allows direct injection of single cells via a standard autosampler resulting in around 1,500 protein groups per analytical run at remarkable reporter ion signal to noise while reducing or eliminating the carrier proteome. We identified close to 2,600 proteins across 170 multiplexed single cells from two highly similar human cell types. This dedicated loss-less workflow allows distinguishing in vitro co-differentiated cell types of self-organizing cardiac organoids based on indicative markers across 150 single cells. In-depth characterization revealed enhanced cellular motility of cardiac endothelial cells and sarcomere organization in cardiomyocytes. Our versatile and automated sample preparation has not only proven to be easily adaptable but is also sufficiently sensitive to drive biological applications of single-cell proteomics.