Jarkko Niemelä
Research Subjects
Jarkko Niemelä has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Jani Keyriläinen
Department of Medical Physics, Turku University Hospital, Turku, Finland
2 shared publications- Jarkko Ojala
Tampere University Hospital
2 shared publications Mika Kapanen
Unit of Radiotherapy, Department of Oncology, Tampere University Hospital, Tampere, Finland
2 shared publications- Saad Ullah Akram
University of Oulu
2 shared publications - Alexander Valdman
Karolinska Institutet
1 shared publication - Anni Borkvel
North Estonia Medical Centre, J. Sütiste tee 19, 13419 Tallinn, Estonia
1 shared publication
Latest Publications
- Open Access
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e138
A Comparative Study Between AI-Generated, Real-Life Clinical as Well as Reference Rectal Volumes Defined in Accordance With the Swedish National STRONG Guidelines in Prostate Cancer Radiotherapy
- 1 November 2021
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 111 (3) , e138
Open AccessA Comparative Study Between AI-Generated, Real-Life Clinical as Well as Reference Rectal Volumes Defined in Accordance With the Swedish National STRONG Guidelines in Prostate Cancer Radiotherapy
- 1 October 2021
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 60 (11) , 1419-1424
Properties of IBA Razor Nano Chamber in small-field radiation therapy using 6 MV FF, 6 MV FFF, and 10 MV FFF photon beams
Small megavoltage photon fields are increasingly used in modern radiotherapy techniques such as stereotactic radiotherapy. Therefore, it is important to study the reliability of dosimetry in the sm...
- 1 October 2021
- Published by Medical Journals Sweden AB in Acta Oncologica
- Vol. 60 (11) , 1419-1424
Properties of IBA Razor Nano Chamber in small-field radiation therapy using 6 MV FF, 6 MV FFF, and 10 MV FFF photon beams
Small megavoltage photon fields are increasingly used in modern radiotherapy techniques such as stereotactic radiotherapy. Therefore, it is important to study the reliability of dosimetry in the sm...
- 1 May 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (3) , 035019
Dose-area product ratio in external small-beam radiotherapy: beam shape, size and energy dependencies in clinical photon beams
In small-field radiotherapy (RT), a significant challenge is to define the amount of radiation dose absorbed in the patient where the quality of the beam has to be measured with high accuracy. The properties of a proposed new beam quality specifier, namely the dose-area-product ratio at 20 and 10 cm depths in water or DAPR 20,10 , were studied to yield more information on its feasibility over the conventional quality specifier tissue-phantom ratio or TPR 20,10 . The DAPR 20,10 may be measured with a large-area ionization chamber (LAC) instead of small volume chambers or semi-conductors where detector, beam and water phantom positioning and beam perturbations introduce uncertainties. The effects of beam shape, size and energy on the DAPR 20,10 were studied and it was shown that the DAPR 20,10 increases with increasing beam energy similarly to TPR 20,10 but in contrast exhibits a small beam size and shape dependence. The beam profile outside the beam limiting devices has been shown to have a large contribution to the DAPR 20,10 . There is potential in large area chambers to be used in DAPR measurement and its use in dosimetry of small-beam RT for beam quality measurements.
- 1 May 2021
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 7 (3) , 035019
Dose-area product ratio in external small-beam radiotherapy: beam shape, size and energy dependencies in clinical photon beams
In small-field radiotherapy (RT), a significant challenge is to define the amount of radiation dose absorbed in the patient where the quality of the beam has to be measured with high accuracy. The properties of a proposed new beam quality specifier, namely the dose-area-product ratio at 20 and 10 cm depths in water or DAPR 20,10 , were studied to yield more information on its feasibility over the conventional quality specifier tissue-phantom ratio or TPR 20,10 . The DAPR 20,10 may be measured with a large-area ionization chamber (LAC) instead of small volume chambers or semi-conductors where detector, beam and water phantom positioning and beam perturbations introduce uncertainties. The effects of beam shape, size and energy on the DAPR 20,10 were studied and it was shown that the DAPR 20,10 increases with increasing beam energy similarly to TPR 20,10 but in contrast exhibits a small beam size and shape dependence. The beam profile outside the beam limiting devices has been shown to have a large contribution to the DAPR 20,10 . There is potential in large area chambers to be used in DAPR measurement and its use in dosimetry of small-beam RT for beam quality measurements.
- Open Access
- 17 November 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (11) , 959
A Deep Learning-Based Automated CT Segmentation of Prostate Cancer Anatomy for Radiation Therapy Planning-A Retrospective Multicenter Study
A commercial deep learning (DL)-based automated segmentation tool (AST) for computed tomography (CT) is evaluated for accuracy and efficiency gain within prostate cancer patients. Thirty patients from six clinics were reviewed with manual- (MC), automated- (AC) and automated and edited (AEC) contouring methods. In the AEC group, created contours (prostate, seminal vesicles, bladder, rectum, femoral heads and penile bulb) were edited, whereas the MC group included empty datasets for MC. In one clinic, lymph node CTV delineations were evaluated for interobserver variability. Compared to MC, the mean time saved using the AST was 12 min for the whole data set (46%) and 12 min for the lymph node CTV (60%), respectively. The delineation consistency between MC and AEC groups according to the Dice similarity coefficient (DSC) improved from 0.78 to 0.94 for the whole data set and from 0.76 to 0.91 for the lymph nodes. The mean DSCs between MC and AC for all six clinics were 0.82 for prostate, 0.72 for seminal vesicles, 0.93 for bladder, 0.84 for rectum, 0.69 for femoral heads and 0.51 for penile bulb. This study proves that using a general DL-based AST for CT images saves time and improves consistency.
- 17 November 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (11) , 959
Open AccessA Deep Learning-Based Automated CT Segmentation of Prostate Cancer Anatomy for Radiation Therapy Planning-A Retrospective Multicenter Study
A commercial deep learning (DL)-based automated segmentation tool (AST) for computed tomography (CT) is evaluated for accuracy and efficiency gain within prostate cancer patients. Thirty patients from six clinics were reviewed with manual- (MC), automated- (AC) and automated and edited (AEC) contouring methods. In the AEC group, created contours (prostate, seminal vesicles, bladder, rectum, femoral heads and penile bulb) were edited, whereas the MC group included empty datasets for MC. In one clinic, lymph node CTV delineations were evaluated for interobserver variability. Compared to MC, the mean time saved using the AST was 12 min for the whole data set (46%) and 12 min for the lymph node CTV (60%), respectively. The delineation consistency between MC and AEC groups according to the Dice similarity coefficient (DSC) improved from 0.78 to 0.94 for the whole data set and from 0.76 to 0.91 for the lymph nodes. The mean DSCs between MC and AC for all six clinics were 0.82 for prostate, 0.72 for seminal vesicles, 0.93 for bladder, 0.84 for rectum, 0.69 for femoral heads and 0.51 for penile bulb. This study proves that using a general DL-based AST for CT images saves time and improves consistency.