YSYan Sha

Yan Sha

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yan Sha has a total of 113 co-authors. Here are the top co-authors by number of shared publications:

  • Naier Lin

    Department of Radiology, Eye & ENT Hospital of Fudan University, Shanghai, China

    12 shared publications
  • Wei Chen

    Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China

    11 shared publications
  • Yue Geng

    Department of Radiology, Eye & ENT Hospital of Fudan University, Shanghai, China

    9 shared publications
  • Mengyan Lin

    Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China, No. 83, Fenyang Road, Xuhui District, Shanghai, China

    7 shared publications
  • Wei Chen

    Shanghai Institute of Medical Imaging, Fudan University, Shanghai, China

    5 shared publications
  • Sihui Yu

    Department of Radiology, Eye & ENT Hospital of Fudan University, Shanghai, China

    4 shared publications

Latest Publications

  • Reply to the Letter to the Editor: “An unenhanced 3D-FLAIR sequence using long repetition time and constant flip angle to image endolymphatic hydrops”

    by Menglong Zhao, Huaili Jiang, Shujie Zhang, Kai Liu, Lei Zhou, Di Wu, Xixi Wen, Junpu Hu, Xuan Wang, Zhuang Liu, et al.

  • Open Access

    Deep learning models for differentiating three sinonasal malignancies using multi-sequence MRI

    by Luxi Wang, Naier Lin, Wei Chen, Hanyu Xiao, Yiyin Zhang, Yan Sha

    To develop MRI-based deep learning (DL) models for distinguishing sinonasal squamous cell carcinoma (SCC), adenoid cystic carcinoma (ACC) and olfactory neuroblastoma (ONB) and to evaluate whether the DL models could improve the diagnostic performance of Senior radiologist (SR) and Junior radiologist (JR). This retrospective analysis consisted of 465 patients (229 sinonasal SCCs, 128 ACCs and 108 ONBs). The training and validation cohorts included 325 and 47 patients and the independent external testing cohort consisted of 93 patients. MRI images included T2-weighted image (T2WI), contrast-enhanced T1-weighted image (CE-T1WI) and apparent diffusion coefficient (ADC). We analyzed the conventional MRI features to choose the independent predictors and built the conventional MRI model. Then we compared the macro- and micro- area under the curves (AUCs) of different sequences and different DL networks to formulate the best DL model [artificial intelligence (AI) model scheme]. With AI assistance, we observed the diagnostic performances between SR and JR. The diagnostic efficacies of SR and JR were assessed by accuracy, Recall, precision, F1-Score and confusion matrices. The independent predictors of conventional MRI included intensity on T2WI and intracranial invasion of sinonasal malignancies. With ExtraTrees (ET) classier, the conventional MRI model owned AUC of 78.8%. For DL models, ResNet101 network showed better performance than ResNet50 and DensNet121, especially for the mean fusion sequence (macro-AUC = 0.892, micro-AUC = 0.875, Accuracy = 0.810), and also good for the ADC sequence (macro-AUC = 0.872, micro-AUC = 0.874, Accuracy = 0.814). Grad-CAM showed that DL models focused on solid component of lesions. With the best AI scheme (ResNet101-mean sequence-based DL model) assistance, the diagnosis performances of SR (accuracy = 0.957, average Recall = 0.962, precision = 0.955, F1-Score = 0.957) and JR (accuracy = 0.925, average Recall = 0.917, precision = 0.931, F1-Score = 0.923) were significantly improved. The ResNet101 network with mean sequence based DL model could effectively differential between sinonasal SCC, ACC and ONB and improved the diagnostic performances of both senior and junior radiologists.


  • An unenhanced 3D-FLAIR sequence using long repetition time and constant flip angle to image endolymphatic hydrops

    by Menglong Zhao, Huaili Jiang, Shujie Zhang, Kai Liu, Lei Zhou, Di Wu, Xixi Wen, Junpu Hu, Xuan Wang, Zhuang Liu, et al.

    Objectives To evaluate a three-dimensional fluid-attenuated inversion recovery (3D-FLAIR) sequence using a long repetition time (TR) and constant flip angle (CFA) in differentiating between perilymph and endolymph in a phantom study, and unenhanced endolymphatic hydrops (EH) imaging in a patient study. Methods Three solutions in similar ion and protein concentrations with endolymph, perilymph, and cerebrospinal fluid were prepared for variable flip angle (VFA) 3D-FLAIR (TR 10,000 ms) and CFA (120°) 3D-FLAIR using different TR (10,000, 16,000, and 20,000 ms). Fifty-two patients with probable or definite Meniere’s disease received unenhanced CFA (120°) 3D-FLAIR using a long TR (20,000 ms) and 4-h-delay enhanced CFA (120°) 3D-FLAIR (TR 16,000 ms). Image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of them were compared. Agreement in the evaluation of the EH degree between them was analyzed. Results In the phantom study, CNRs between perilymphatic and endolymphatic samples of VFA 3D-FLAIR (TR 10,000 ms) and CFA 3D-FLAIR (TR 10,000, 16,000, and 20,000 ms) were 6.66 ± 1.30, 17.90 ± 2.76, 23.87 ± 3.09, and 28.22 ± 3.15 (p < 0.001). In patient study, average score (3.65 ± 0.48 vs. 4.19 ± 0.40), SNR (34.56 ± 9.80 vs. 51.40 ± 11.27), and CNR (30.66 ± 10.55 vs. 45.08 ± 12.27) of unenhanced 3D-FLAIR were lower than enhanced 3D-FLAIR (p < 0.001). Evaluations of the two sequences showed excellent agreement in the cochlear and vestibule (Kappa value: 0.898 and 0.909). Conclusions The CFA 3D-FLAIR sequence using a long TR could be used in unenhanced EH imaging with high accuracy. Clinical relevance statement Unenhanced imaging of endolymphatic hydrops is valuable in the diagnosis and follow-up of patients, especially those who cannot receive contrast-enhanced MRI. Key Points Ion and protein concentration differences can be utilized in differentiating endolymph and perilymph on MRI. Endolymphatic and perilymphatic samples could be differentiated in vitro on this 3D-FLAIR sequence. This unenhanced 3D-FLAIR sequence is in excellent agreement with the enhanced constant flip angle 3D-FLAIR sequence.


  • A novel radiomics nomogram based on T2-sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) images for predicting cochlear and vestibular endolymphatic hydrops in Meniere’s disease patients

    by Wei Chen, Sihui Yu, Hanyu Xiao, Naier Lin, Xiaolin Wang, Bingrong Li, Yan Sha

    Objectives To construct and validate a radiomics nomogram based on T2-sampling perfection with application-optimized contrasts using different flip-angle evolutions (SPACE) images for predicting cochlear and vestibular endolymphatic hydrops (EH) in Meniere’s disease patients. Methods A total of 156 patients (312 affected ears) with bilateral definite Meniere’s disease who underwent delayed enhancement MRI scans were enrolled in this study. All ears of the patients were divided into a training set (n = 218) and an internal validation set (n = 94). A radiomics nomogram was constructed from radiomics features extracted from the T2-SPACE images, and a radiomics score was calculated. Performance of the radiomics nomogram was assessed using receiver operating characteristics analysis. Results Five features were selected for the construction of the cochlear radiomics nomogram, and seven features for the vestibular radiomics nomogram. The radiomics nomograms exhibited robust performance in differentiating between EH-positive and EH-negative statuses in both training and validation cohorts, with the area under the receiver operating characteristics curve values for cochlear and vestibular radiomic nomograms being 0.703 and 0.728 in the training set, and 0.718 and 0.701 in the validation set, respectively. Conclusion The novel radiomics nomograms based on T2-SPACE images were successfully constructed to predict cochlear and vestibular EH in Meniere’s disease. The models showed a solid and superior performance and may play an important role in the EH prediction. Clinical relevance statement We constructed a novel radiomics nomogram, which can be a very useful tool for predicting cochlear and vestibular endolymphatic hydrops in Meniere’s disease patients. Key Points • This is the first T2-SPACE-based nomogram to predict cochlear and vestibular endolymphatic hydrops. • The nomogram is of great value to patients who are unable to undergo delayed enhancement MRI scans.


  • Diffusional kurtosis imaging in differentiating nonarteritic anterior ischemic optic neuropathy from acute optic neuritis

    by Ping Lu, Rujian Hong, Guohong Tian, Xilan Liu, Yan Sha, Jibin Zhang, Ximing Wang

    Purpose We aimed to determine the feasibility of using DKI to characterize pathological changes in nonarteritic anterior ischemic optic neuropathy (NAION) and to differentiate it from acute optic neuritis (ON). Methods Orbital DKI was performed with a 3.0 T scanner on 75 patients (51 with NAION and 24 with acute ON) and 15 healthy controls. NAION patients were further divided into early and late groups. The mean kurtosis (MK), axial kurtosis (AK), radial kurtosis (RK), mean diffusivity (MD), fractional anisotropy (FA), radial diffusivity (RD), and axial diffusivity (AD) were calculated to perform quantitative analyses among groups; and receiver operating characteristic curve analyses were also performed to determine their effectiveness of differential diagnosis. In addition, correlation coefficients were calculated to explore the correlations of the DKI-derived data with duration of disease. Results The MK, RK, and AK in the affected nerves with NAION were significantly higher than those in the controls, while the trend of FA, RD, and AD was a decline; in acute ON patients, except for RD, which increased, all DKI-derived kurtosis and diffusion parameters were significantly lower than controls (all P < 0.008). Only AK and MD had statistical differences between the early and late groups. Except for MD (early group) and FA, all other DKI-derived parameters were higher in NAION than in acute ON; and parameters in the early group showed better diagnostic efficacy in differentiating NAION from acute ON. Correlation analysis showed that time was negatively correlated with MK, RK, AK, and FA and positively correlated with MD, RD, and AD (all P < 0.05). Conclusion DKI is helpful for assessing the specific pathologic abnormalities resulting from ischemia in NAION by comparison with acute ON. Early DKI should be performed to aid in the diagnosis and evaluation of NAION.


  • Analysis of the initial orbital MRI in aquaporin-4 antibody-positive optic neuritis (AQP4-ON): lesion location and lesion length can be predictive of visual prognosis

    by Hanyu Shaw, Chaoyi Feng, Meng Qi, Yalan Deng, Wei Chen, Yiyin Zhang, Luxi Wang, Naier Lin, Guohong Tian, Yan Sha

    Purpose Despite mounting evidence indicating that aquaporin-4 antibody-positive optic neuritis (AQP4-ON) presents a less favorable prognosis than other types of optic neuritis, there exists substantial heterogeneity in the prognostic outcomes within the AQP4-ON cohort. Considering the persistent debate over the role of MRI in assessing the prognosis of optic neuritis, we aim to investigate the correlation between the MRI appearance and long-term visual prognosis in AQP4-ON patients. Methods We retrospectively reviewed the ophthalmological and imaging data of AQP4-ON patients admitted to our Neuro-ophthalmology Department from January 2015 to March 2018, with consecutive follow-up visits for a minimum of 3 years. Results A total of 51 AQP4-ON patients (59 eyes) meeting the criteria were enrolled in this research. After assessing the initial orbital MR images of each patient at the first onset, we observed the involvement of the canalicular segment (p < 0.001), intracranial segment (p = 0.004), optic chiasm (p = 0.009), and the presence of LEON (p = 0.002) were significantly different between recovery group and impairment group. For quantitative measurement, the length of the lesions is significantly higher in the impairment group (20.1 ± 9.3 mm) than in the recovery group (12.5 ± 5.3 mm) (p = 0.001). Conclusion AQP4-ON patients with involvement of canalicular, intracranial segment and optic chiasm of the optic nerve, and the longer range of lesions threaten worse vision prognoses. Timely MR examination during the initial acute phase can not only exclude the intracranial or orbital mass lesions but also indicate visual prognosis in the long term.


  • A 3-hour time interval may not be sufficient for delayed enhancement magnetic resonance imaging with intravenous gadoteridol injection based on 3d-real IR sequence of the inner ear in Meniere’s disease patient

    by Wei Chen, Hanyu Xiao, Yiyin Zhang, Luxi Wang, Bingrong Li, Yan Sha

    Background: Magnetic resonance imaging (MRI) can be applied to visualize endolymphatic hydrops (EH). Aims/Objectives: To explore whether a 3-h time interval was feasible for clinical practice. Materials and methods: We prospectively enrolled 15 patients with unilateral Meniere's disease, each of whom underwent delayed enhancement MRI scan of the inner ear after intravenous gadoteridol injection at a 3-h interval. The ears of these patients were divided into two groups (group A: the affected ears; group B: the unaffected ears). Among the two groups, the signal intensity in perilymphatic area of the basal turn of cochlea, the results of visual evaluations in the vestibule, cochlea and semicircular canal and the detection results of EH were compared. Results: Regarding the signal intensity, a difference was found between group A and group B (p = .016). Besides, no difference was found between the visual evaluations in the vestibule, cochlea and semicircular canal of the two groups. Regarding the detection results of EH, group A (6 vestibules were undiagnosable; 8 cochleae were undiagnosable); group B (9 vestibules were undiagnosable; 10 cochleae were undiagnosable). Conclusions and significance: In the clinical application of gadoteridol for the inner ear, 3-h delayed MR imaging may not be sufficient.


  • Differentiation of Sinonasal NKT From Diffuse Large B-Cell Lymphoma Using Machine Learning and MRI-Based Radiomics

    by Yiyin Bs Zhang, Naier Lin, Hanyu Bs Xiao, Enhui Xin, Yan Sha

    Purpose: The aim of this study was to construct and validate a noninvasive radiomics method based on magnetic resonance imaging to differentiate sinonasal extranodal natural killer/T-cell lymphoma from diffuse large B-cell lymphoma. Methods: We collected magnetic resonance imaging scans, including contrast-enhanced T1-weighted imaging and T2-weighted imaging, from 133 patients with non-Hodgkin lymphoma (103 sinonasal extranodal natural killer/T-cell lymphoma and 30 diffuse large B-cell lymphoma) and randomly split them into training and testing cohorts at a ratio of 7:3. Clinical characteristics and image performance were analyzed to build a logistic regression clinical-image model. The radiomics features were extracted on contrast-enhanced T1-weighted imaging and T2-weighted imaging images. Maximum relevance minimum redundancy, selectKbest, and the least absolute shrinkage and selection operator algorithms (LASSO) were applied for feature selection after balancing the training set. Five machine learning classifiers were used to construct the single and combined sequences radiomics models. Sensitivity, specificity, accuracy, precision, F1score, the area under receiver operating characteristic curve, and the area under precision-recall curve were compared between the 15 models and the clinical-image model. The diagnostic results of the best model were compared with those of 2 radiologists. Results: The combined sequence model using support vector machine proves to be the best, incorporating 7 features and providing the highest values of specificity (0.903), accuracy (0.900), precision (0.727), F1score (0.800), and area under precision-recall curve (0.919) with relatively high sensitivity (0.889) in the testing set, along with a minimum Brier score. The diagnostic results differed significantly (P < 0.05) from those of radiology residents, but not significantly (P > 0.05) from those of experienced radiologists. Conclusions: Magnetic resonance imaging based on machine learning and radiomics to identify the type of sinonasal non-Hodgkin lymphoma is effective and has the potential to help radiology residents for diagnosis and be a supplement for biopsy.


  • Open Access

    Middle Ear Teratoma: Clinical and Imaging Features

    by Jun-Hua Liu, Wen-Hu Huang, Yin Liu, Fang Zhang, Yan Sha

    Background: Teratoma is a true neoplasm composed of a number of different types of tissue derived from the three germinal layers but rarely occurs in the middle ear (ME). The features of middle ear teratomas (MET) have not been well described. Objective: The objective of this study is to explore the clinical and imaging features of MET, and report 2 rare cases of MET with ear malformation that have never been reported. Materials and Methods: The clinical, CT and MRI data of 8 patients with a pathological diagnosis of MET were collected and retrospectively mined, and 14 patients with MET reported in previous literature were also reviewed. Results: ① Female, left ear predominance in MET, and the most common symptoms were otorrhea and hearing loss. ② On CT and MRI, the MET presented as an irregular soft tissue mass that was heterogeneous, with fatty tissue and involved multiple sites, and the ET and tympanum were correspondingly expanded and locally destroyed. ③ Mictotia with MET in two patients was presented, which was the first report. Conclusion: MET has female sex and left ear predominance. CT and MRI can be used to diagnose MET and display its extent and its relationship to the carotid canal in detail. Complete surgical excision is the definitive treatment.


  • The role of D-dimer and fibrinogen testing in catheter-directed thrombolysis with urokinase for deep venous thrombosis

    by Qiang Liu, Liang Chen, Zhengyu Wang, Zhiqing Peng, Wei Chen, Yucheng Pan, Yongli Wang, Yan Sha

    Background: During catheter-directed thrombolysis (CDT), D-dimer (D-D) are generated in large quantities and fibrinogen (FIB) is continuously consumed. Reduction of FIB increases the risk of bleeding. However, there are currently few studies on the relationship between D-D and FIB concentrations during CDT. Objectives: To evaluate the relationship of D-D and FIB concentrations during CDT with urokinase for deep venous thrombosis (DVT). Method: 17 patients with lower limb DVT were enrolled and treated with CDT. The concentrations of plasma D-D and FIB were measured every 8 h during thrombolysis. The degree of thrombolysis was evaluated, the change rules of D-D and FIB concentrations were analyzed, and the change curve graphs were drawn. The “thrombus volume,” “thrombolysis time,” “thrombolysis ratio,” “D-D peak,” “D-D rising speed,” “FIB falling speed,” and “duration of D-D elevation” were calculated in each patient. The mixed model was used to simulate the time change trend of the plasma D-D and FIB concentrations. Pearson method and linear regression were used to analyze the correlation and linear relationship, respectively. Results: The D-D concentration first increased rapidly and then decreased gradually, and the FIB concentration continued to decrease during thrombolysis. The rate of the decline of FIB varies with the urokinase dose. The thrombus volume is positively correlated with D-D rising speed, duration of D-D elevation, D-D peak, and FIB falling speed; the D-D rising speed is positively correlated with the D-D peak and FIB falling speed; and the D-D peak is positively correlated with the FIB falling speed. The correlation coefficients were all statistically significant ( p < 0.05). Efficacy reached level I–II in 76.5% patients. No major bleeding occurred in any of the patients. Conclusion: During CDT with urokinase for DVT, the concentrations of D-D and FIB show specific changes, and there are some specific relationships between each other. Understanding these changes and relationships may be helpful to adjust the thrombolysis time and urokinase dose more rationally.