YCYu-Min Chang

Yu-Min Chang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yu-Min Chang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Ming-Cheng Tai

    Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical Center, Taipei 114, Taiwan

    3 shared publications
  • Ke-Hung Chien

    From the Department of Ophthalmology (Y.M.C., K.H.C.), Tri-Service General Hospital; and School of Medicine, National Defense Medical University, Taipei, Taiwan

    2 shared publications
  • Ke-Hung Chien

    Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical University, Taipei, Taiwan

    2 shared publications
  • Ting-Yi Lin

    Department of Ophthalmology, Tri-Service General Hospital, National Defense Medical Center, Taipei 11490, Taiwan

    2 shared publications
  • Tzu-Heng Weng

    Department of Ophthalmology, Tri-Service General Hospital and School of Medicine, National Defense Medical University, Taipei 114202, Taiwan

    2 shared publications
  • Chang-Min Liang

    Department of Ophthalmology, Tri-Service General Hospital and School of Medicine, National Defense Medical University, Taipei 114202, Taiwan

    1 shared publication

Latest Publications

  • Open Access

    Therapeutic Outcomes of Combined Eyelid Hygiene, Intense Pulsed Light, and Meibomian Gland Expression in Meibomian Gland Dysfunction

    by Chien-Cheng Chien, Yu-Min Chang, Chang-Min Liang, Ke-Hung Chien, Ming-Cheng Tai, Ting-Yi Lin, Tzu-Heng Weng

    Background/Objectives: This study aimed to assess the effectiveness of a combination therapy comprising eyelid hygiene, intense pulsed light (IPL), and meibomian gland expression in patients with meibomian gland dysfunction (MGD). Methods: This retrospective study included MGD patients who completed at least three sessions of combination therapy administered at 4-week intervals, with a minimum follow-up period of 6 months. Ocular surface parameters were evaluated at baseline and at 1, 3, and 6 months after treatment initiation. Based on the clinical response following the initial three sessions, patients were categorized into either the standard treatment group (3 sessions) or the extended treatment group, who received three additional sessions of the same combination therapy. Results: A total of 107 patients (77 females; 30 males) were enrolled. 74 patients received standard treatment, and 33 received extended treatment. In the standard group, significant improvements compared with baseline were observed in the Ocular Surface Disease Index score, non-invasive tear break-up time, corneal staining, lid margin plugging, telangiectasia, and the meibomian gland expressibility score. Conversely, in the extended group, only the meibomian gland expressibility score showed significant improvements at the 3-month follow-up. Conclusions: The standard combination therapy resulted in significant and durable improvements in approximately 70% of MGD patients, with effects persisting for at least 3 months post-treatment. These findings support the clinical utility of this multimodal approach and highlight the need for biomarkers to predict treatment response.


  • Open Access

    Changes in Corneal Epithelial Thickness and Higher-Order Aberrations Treated With a Newly Designed Orthokeratology Lens

    by Tzu-Heng Weng, Wen-Pin Lin, Ting-Yi Lin, Ming-Cheng Tai, Ke-Hung M.D. Chien, Yu-Min Chang

    Objectives: To evaluate the impact of a new orthokeratology (OrthoK) lens on corneal epithelial thickness and higher-order aberrations (HOAs). Methods: This three-arm, prospective, crossover study randomly assigned participants to the control group, T1 group (1.5× control-group lens-design reverse curve [RC] height), and T2 group (2× control-group lens-design RC height). Participants underwent basic ophthalmological examinations, corneal topography, and corneal epithelial thickness and HOA measurements at each visit. Corneal zones were analyzed based on topographic changes induced by lens wear, corresponding to the central treatment zone and the reverse zone. Results: The spherical equivalent was significantly lower in T1 and T2 than in the control group on days 7 and 28 of lens wear (PPP<0.01). T2 demonstrated higher levels of HOA than the other groups. Conclusions: This new design of OrthoK can alter the corneal epithelium thickness and stabilize central corneal flattening, thereby achieving a better correction for myopia. However, this design also induces HOAs and is associated with a mild but significant compromise in uncorrected visual acuity compared with conventional designs. Therefore, clinicians should weigh the potential benefits of myopia control against the associated effects on visual quality when selecting OrthoK lens designs.


  • Open Access

    The Effects of Topical Cyclosporine 0.05% on Dry Eye Symptoms of Postcataract Surgery

    by Yu-Min Chang, Ke-Hung Chien

    Background: Dry eye disease is a common complication after cataract surgery, often impairing visual recovery and patient satisfaction. Conventional management includes artificial tears and mild corticosteroids, but their efficacy is limited. Aim: This study evaluated the effect of topical cyclosporine 0.05% on post-cataract surgery–related dry eye symptoms compared with artificial tears plus fluorometholone and no additional treatment. Methods: Sixty eyes of 60 patients who had undergone cataract surgery within the past 3 months were enrolled. After standard postoperative therapy with econopred and cravit for 1 week, patients were assigned to three groups: artificial tears + fluorometholone 0.1% (20 eyes), topical cyclosporine 0.05% starting 2 weeks preoperatively and continuing for 6 weeks postoperatively (19 eyes), and control with no additional treatment (21 eyes). Ocular surface disease index (OSDI), tear meniscus height (TMH), noninvasive keratograph tear breakup time (NIKBUT), and redness score (RS) were assessed preoperatively and at 1 week and 1 month postoperatively. Results: The cyclosporine group showed significant improvements in OSDI and TMH over time, with better outcomes at 1 month compared with the other groups. NIKBUT and RS declined postoperatively in all groups, but the decrease was more pronounced in the artificial tears + fluorometholone and control groups. Cyclosporine did not improve NIKBUT or RS. Conclusion: Topical cyclosporine 0.05% demonstrated superior benefits in relieving post-cataract surgery dry eye symptoms compared with artificial tears + fluorometholone or no treatment, though larger studies are needed to confirm its efficacy.

  • Femtosecond laser-assisted astigmatic keratotomy versus toric IOL implantation for correcting astigmatism in cataract patients: a systematic review and meta-analysis with trial sequential analysis

    by Wei-Ting Yen, Tzu-Heng Weng, Ting-Yi Lin, Ming-Cheng Tai, Yi-Hao Chen, Yu-Min Chang

    Aims To compare the refractive and visual outcomes of femtosecond laser-assisted astigmatic keratotomy (FSAK) and toric intraocular lens (IOL) implantation for correcting astigmatism in cataract patients. Methods Studies were retrieved from the Ovid-Medline, EMBASE, Cochrane Central Register of Controlled Trials and Scopus which compared FSAK and toric IOL for astigmatism correction in cataract patients. Outcome measures included postoperative refractive cylinder, correction index, uncorrected distance visual acuity (UDVA), the proportion of patients achieving a residual refractive cylinder of 1.00 dioptre or less, target-induced astigmatism (TIA) and surgically induced astigmatism (SIA). The trial sequential analysis (TSA) was used to collect firm evidence supporting our conclusion. Results 9 studies encompassing 590 participants were analysed. The meta-analysis revealed that toric IOLs could result in less postoperative refractive cylinder and provide better UDVA compared with FSAK. The TSA disclosed strong evidence of lower postoperative refractive cylinder in the toric IOL group compared with that of the FSAK group. FSAK showed a smaller correction index and lower mean TIA and SIA compared with toric IOLs. Conclusions For cataract patients, both FSAK and toric IOLs are effective methods for correcting astigmatism. However, toric IOLs offer less postoperative astigmatism and result in better postoperative UDVA compared with FSAK. In vector analysis of astigmatism, toric IOLs can also produce higher TIA and SIA. Additionally, neither method is associated with severe untreatable complications. Therefore, the conclusion is that toric IOLs are the preferred choice for astigmatism correction in cataract patients and FSAK serves as a viable alternative when toric IOLs are contraindicated.


  • Open Access

    Serum Calcium Level as a Useful Surrogate for Risk of Elevated Intraocular Pressure

    by Yu-Min Chang, Jiann-Torng Chen, Ming-Cheng Tai, Wei-Liang Chen, Ying-Jen Chen

    Background: Uncontrolled intraocular pressure (IOP) plays a principal role in the deterioration of glaucoma, and the intraocular pressure is also accepted as the most important modifiable factor. Calcium ion has been found to play a vital role in regulating the resistance of the trabecular meshwork in humans. However, the relationship between serum total calcium and IOP has not been well-established. Methods: We investigated the association between serum total calcium and the IOP in a large population (14,037 eligible participants, consisting of 7712 men and 6325 women, were included) at the Tri-Service General Hospital from 2010 to 2016. Several models of covariate adjustments associated with IOP were designed. Univariate and multivariate regression analysis was performed for gender differences in the association between the serum total calcium level and IOP. Results: There was a significant relationship between serum total calcium levels and IOP in women and men with a β coefficient of 0.050 (95% confidence interval (CI), 0.030–0.069) and 0.025 (95%CI, 0.007–0.043). Notably, participants in the highest tertiles of serum total calcium levels had significantly higher IOP, in both the male and female participants. Conclusions: Our study shows that IOP is significantly associated with serum total calcium levels in a large Asian population. This study supports the notion that serum total calcium may play an important role in groups at high risk for elevated IOP.


  • Utilization of reduction slag and waste sludge for Portland cement clinker production

    by Kae‐Long Lin, Kang‐Wei Lo, Ming‐Jui Hung, Chao‐Lung Hwang, Ta‐Wui Cheng, Yu‐Min Chang

    The feasibility of recycling the reduction slag, limestone sludge, iron‐oxide sludge, and stone sludge produced in the manufacture of cement was investigated through compressive strength testing, differential thermal and thermogravimetric analysis, X‐ray diffraction, and 29Si nuclear magnetic resonance analysis. The major crystalline phases of ecocement clinkers, namely C3S, β‐C2S, C4AF, and C3A, were observed. C3S content decreased and β‐C2S and α‐C2S content increased in the reduction slag. The compressive strength of EcoA pastes (ecocement contain 78% of limestone sludge, 19.51% of stone sludge and 2.49% iron‐oxide sludge) was similar to that of commercial ordinary Portland cement. The Q0 (−70 ppm) species shifted to the Q1 (−80 ppm), and Q2 (−87 ppm) species during curing. The addition of stone sludge, iron‐oxide sludge, and limestone sludge had no negative effect on the hydration of the cement pastes. In contrast, the addition of reduction slag negatively affected the formation of clinker minerals. Cement samples with reduction slag content of 1–7 wt % had lower 28‐, 60‐, and 90‐day compressive strength than did the control mix. © 2017 American Institute of Chemical Engineers Environ Prog, 37: 669–677, 2018


  • Circulating Fluidized Bed Incineration of Industrial Solid Wastes

    by Yu-Min Chang, Jung-Shing Kang, Chin-Chen Ho

    A pilot scale test facility of a circulating fluidized bed incinerator was established to generate design and operation data and help assess the technical feasibility for industrial applications. The use of high turbulence in the combustion zone and feeding an acid-capturer directly into the incinerator to absorb acid gases eliminates the costly afterburner and scrubber. This paper presents some systematic incineration tests of uniform industrial wastes such as paper mill sludge cake, rubber waste and petroleum coke. Sludge cakes with high moisture and low heating values can be treated to a low emission level by co-firing with coal. The high superficial gas velocity has improved combustion efficiency but increases NOx emissions. However, sulphur content has almost no influence on sulphur retention. The problems of CO/NOx emissions and circulation stability are also discussed.