Jan Hovind
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jan Hovind has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Anders Kaestner
PSI Center for Neutron and Muon Sciences, Paul Scherrer Institute, Villigen, Switzerland
5 shared publications - Pavel Trtik
Laboratory for Neutron Scattering and Imaging, Paul Scherrer Institut, Villigen PSI, Switzerland
3 shared publications - Andris Jakovics
Institute of Numerical Modelling, University of Latvia, Jelgavas Street 3, LV-1004 Riga, Latvia
2 shared publications - Dariusz Jakub Gawryluk
Paul Scherrer Institute
2 shared publications - David Mannes
PSI Center for Neutron and Muon Sciences Paul Scherrer Institute Villigen Switzerland
2 shared publications - Eberhard Lehmann
Laboratory for Neutron Scattering & Imaging, Paul Scherrer Institut, Birmenstorf, Switzerland
2 shared publications
Latest Publications
- Open Access
- 2 November 2024
- Published by Springer Nature in Applied Physics A
- Vol. 130 (11) , 1-19
Neutron tomography and image registration methods to study local physical deformations and attenuation variations in treated archaeological iron nail samples
This study presents a preliminary examination of the effects of environment changes post-excavation on heavily corroded archaeological Roman iron nails using neutron tomography and image registration techniques. Roman nails were exposed to either a high relative humidity environment, or fast thermal drying as primary experiments to show the power of this imaging technique to monitor and quantify the structural changes of corroded metal artifacts. This research employed a series of pre- and post-treatment tomography acquisitions (time-series) complemented by advanced image registration methods. Based on mutual information (MI) metrics, we performed rigid body and affine image registrations to meticulously account for sample repositioning challenges and variations in imaging parameters. Using non-affine local registration results, in a second step, we detected localized expansion and shrinkage in the samples attributable to imposed environmental changes. Specifically, we observed local shrinkage on the nail that was dried, mostly in their Transformed Medium (TM), the outer layer where corrosion products are cementing soil and sand particles. Conversely, the sample subjected to high relative humidity environment exhibited localized expansion, with varying degrees of change across different regions. This work highlights the efficacy of our registration techniques in accommodating manual removal or loss of extraneous material (loosely adhering soil and TM layers around the nails) post-initial tomography, successfully capturing local structural changes with high precision. Using differential analysis on the accurately registered samples we could also detect and volumetrically quantify the variation in moisture and detect changes in active corrosion sites (ACS) in the sample. These preliminary experiments allowed us to advance and optimize the application of a neutron tomography and image registration workflow for future, more advanced experiments such as humidity fluctuations, corrosion removal through micro-blasting, dechlorination and other stabilization treatments.
- 2 November 2024
- Published by Springer Nature in Applied Physics A
- Vol. 130 (11) , 1-19
Open AccessNeutron tomography and image registration methods to study local physical deformations and attenuation variations in treated archaeological iron nail samples
This study presents a preliminary examination of the effects of environment changes post-excavation on heavily corroded archaeological Roman iron nails using neutron tomography and image registration techniques. Roman nails were exposed to either a high relative humidity environment, or fast thermal drying as primary experiments to show the power of this imaging technique to monitor and quantify the structural changes of corroded metal artifacts. This research employed a series of pre- and post-treatment tomography acquisitions (time-series) complemented by advanced image registration methods. Based on mutual information (MI) metrics, we performed rigid body and affine image registrations to meticulously account for sample repositioning challenges and variations in imaging parameters. Using non-affine local registration results, in a second step, we detected localized expansion and shrinkage in the samples attributable to imposed environmental changes. Specifically, we observed local shrinkage on the nail that was dried, mostly in their Transformed Medium (TM), the outer layer where corrosion products are cementing soil and sand particles. Conversely, the sample subjected to high relative humidity environment exhibited localized expansion, with varying degrees of change across different regions. This work highlights the efficacy of our registration techniques in accommodating manual removal or loss of extraneous material (loosely adhering soil and TM layers around the nails) post-initial tomography, successfully capturing local structural changes with high precision. Using differential analysis on the accurately registered samples we could also detect and volumetrically quantify the variation in moisture and detect changes in active corrosion sites (ACS) in the sample. These preliminary experiments allowed us to advance and optimize the application of a neutron tomography and image registration workflow for future, more advanced experiments such as humidity fluctuations, corrosion removal through micro-blasting, dechlorination and other stabilization treatments.
- 29 November 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (6) , 1792-1801
The FALCON double-detector Laue diffractometer add-on for grain mapping at POLDI
Laue 3D neutron diffraction tomography (Laue 3DNDT) is a novel tomographic approach that enables non-destructive resolution of the 3D microstructure of polycrystalline materials, utilizing a high-intensity white beam of neutrons, resulting in high experimental efficiency. This article describes the functionality of the fast-acquisition Laue camera for neutrons (FALCON), a double-detector system setup used for Laue 3DNDT experiments at the pulse-overlap diffractometer (POLDI) at the SINQ neutron source of the Paul Scherrer Institute. The reported commissioning includes standard experimental protocols, strategies for acquiring data and a detailed characterization of the measurement system. Finally, single-crystal measurements for calibration and a full grain map of a CoNiGa oligocrystalline sample, extracted from a pilot study, are presented. A detailed understanding of the performance of the FALCON instrumentation is vital for the future advancement of the Laue 3DNDT algorithm, including, but not limited to, improved morphology reconstructions and strain mapping.
- 29 November 2023
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 56 (6) , 1792-1801
The FALCON double-detector Laue diffractometer add-on for grain mapping at POLDI
Laue 3D neutron diffraction tomography (Laue 3DNDT) is a novel tomographic approach that enables non-destructive resolution of the 3D microstructure of polycrystalline materials, utilizing a high-intensity white beam of neutrons, resulting in high experimental efficiency. This article describes the functionality of the fast-acquisition Laue camera for neutrons (FALCON), a double-detector system setup used for Laue 3DNDT experiments at the pulse-overlap diffractometer (POLDI) at the SINQ neutron source of the Paul Scherrer Institute. The reported commissioning includes standard experimental protocols, strategies for acquiring data and a detailed characterization of the measurement system. Finally, single-crystal measurements for calibration and a full grain map of a CoNiGa oligocrystalline sample, extracted from a pilot study, are presented. A detailed understanding of the performance of the FALCON instrumentation is vital for the future advancement of the Laue 3DNDT algorithm, including, but not limited to, improved morphology reconstructions and strain mapping.
- Open Access
- 18 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (20) , 9710
Resolving Gas Bubbles Ascending in Liquid Metal from Low-SNR Neutron Radiography Images
We demonstrate a new image processing methodology for resolving gas bubbles travelling through liquid metal from dynamic neutron radiography images with an intrinsically low signal-to-noise ratio. Image pre-processing, denoising and bubble segmentation are described in detail, with practical recommendations. Experimental validation is presented—stationary and moving reference bodies with neutron-transparent cavities are radiographed with imaging conditions representative of the cases with bubbles in liquid metal. The new methods are applied to our experimental data from previous and recent imaging campaigns, and the performance of the methods proposed in this paper is compared against our previously achieved results. Significant improvements are observed as well as the capacity to reliably extract physically meaningful information from measurements performed under highly adverse imaging conditions. The showcased image processing solution and separate elements thereof are readily extendable beyond the present application, and have been made open-source.
- 18 October 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (20) , 9710
Open AccessResolving Gas Bubbles Ascending in Liquid Metal from Low-SNR Neutron Radiography Images
We demonstrate a new image processing methodology for resolving gas bubbles travelling through liquid metal from dynamic neutron radiography images with an intrinsically low signal-to-noise ratio. Image pre-processing, denoising and bubble segmentation are described in detail, with practical recommendations. Experimental validation is presented—stationary and moving reference bodies with neutron-transparent cavities are radiographed with imaging conditions representative of the cases with bubbles in liquid metal. The new methods are applied to our experimental data from previous and recent imaging campaigns, and the performance of the methods proposed in this paper is compared against our previously achieved results. Significant improvements are observed as well as the capacity to reliably extract physically meaningful information from measurements performed under highly adverse imaging conditions. The showcased image processing solution and separate elements thereof are readily extendable beyond the present application, and have been made open-source.
- Open Access
Resolving gas bubbles ascending in liquid metal from low-SNR neutron radiography images
We demonstrate a new image processing methodology for resolving gas bubbles travelling through liquid metal from dynamic neutron radiography images with intrinsically low signal-to-noise ratio. Image pre-processing, denoising and bubble segmentation are described in detail, with practical recommendations. Experimental validation is presented - stationary and moving reference bodies with neutron-transparent cavities are radiographed with imaging conditions similar to the cases with bubbles in liquid metal. The new methods are applied to our experimental data from previous and recent imaging campaigns, and the performance of the methods proposed in this paper is compared against our previously developed methods. Significant improvements are observed as well as the capacity to reliably extract physically meaningful information from measurements performed under highly adverse imaging conditions. The showcased image processing solution and separate elements thereof are readily extendable beyond the present application, and have been made open-source.
Open AccessResolving gas bubbles ascending in liquid metal from low-SNR neutron radiography images
We demonstrate a new image processing methodology for resolving gas bubbles travelling through liquid metal from dynamic neutron radiography images with intrinsically low signal-to-noise ratio. Image pre-processing, denoising and bubble segmentation are described in detail, with practical recommendations. Experimental validation is presented - stationary and moving reference bodies with neutron-transparent cavities are radiographed with imaging conditions similar to the cases with bubbles in liquid metal. The new methods are applied to our experimental data from previous and recent imaging campaigns, and the performance of the methods proposed in this paper is compared against our previously developed methods. Significant improvements are observed as well as the capacity to reliably extract physically meaningful information from measurements performed under highly adverse imaging conditions. The showcased image processing solution and separate elements thereof are readily extendable beyond the present application, and have been made open-source.
- Open Access
- 23 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 3825
The XTRA Option at the NEUTRA Facility—More Than 10 Years of Bi-Modal Neutron and X-ray Imaging at PSI
Just after the start into the new millennium the concept for combined neutron and X-ray imaging was introduced by extending the standard configuration of the thermal neutron imaging NEUTRA instrument with a complementary 320 kV X-ray tube setup. Using essentially the same detector configuration for both neutron and X-ray imaging enables a pixel-wise (in radiography) and a voxel-wise (in tomography) correlation and combination of attenuation data. The optimal use and analyses of such complementary data sets depend on the specific investigation and research question and range from a combinatory interpretation of separately analyzed images to full data fusion approaches. Here, several examples from more than a decade of bimodal neutron and X-ray imaging at NEUTRA at PSI shall be reviewed.
- 23 April 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (9) , 3825
Open AccessThe XTRA Option at the NEUTRA Facility—More Than 10 Years of Bi-Modal Neutron and X-ray Imaging at PSI
Just after the start into the new millennium the concept for combined neutron and X-ray imaging was introduced by extending the standard configuration of the thermal neutron imaging NEUTRA instrument with a complementary 320 kV X-ray tube setup. Using essentially the same detector configuration for both neutron and X-ray imaging enables a pixel-wise (in radiography) and a voxel-wise (in tomography) correlation and combination of attenuation data. The optimal use and analyses of such complementary data sets depend on the specific investigation and research question and range from a combinatory interpretation of separately analyzed images to full data fusion approaches. Here, several examples from more than a decade of bimodal neutron and X-ray imaging at NEUTRA at PSI shall be reviewed.
- 4 June 2013
- Published by Cambridge University Press (CUP) in The Antiquaries Journal
- Vol. 93, 25-53
New insights into early bronze age damascene technique north of the alps
Damascening, defined in this context as the inlay of one metal into a different metal base, is a rare decorative technique in the Early Bronze Age, known only from seven bronze artefacts found north of the Alps. This paper reports on the first thorough scientific examination of one such find, the axe from Thun-Renzenbühl grave no. 1. This interdisciplinary project involving several institutions in Germany and Switzerland investigated the axe by means of neutron radiographic imaging and X-ray microprobe methods, supported by microscopic examination. The result is an attempt to reconstruct the fabrication and decoration process and to reconsider the enigmatic question of the origins of the damascene technique north of the Alps.
- 4 June 2013
- Published by Cambridge University Press (CUP) in The Antiquaries Journal
- Vol. 93, 25-53
New insights into early bronze age damascene technique north of the alps
Damascening, defined in this context as the inlay of one metal into a different metal base, is a rare decorative technique in the Early Bronze Age, known only from seven bronze artefacts found north of the Alps. This paper reports on the first thorough scientific examination of one such find, the axe from Thun-Renzenbühl grave no. 1. This interdisciplinary project involving several institutions in Germany and Switzerland investigated the axe by means of neutron radiographic imaging and X-ray microprobe methods, supported by microscopic examination. The result is an attempt to reconstruct the fabrication and decoration process and to reconsider the enigmatic question of the origins of the damascene technique north of the Alps.