Naoki Hoshino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Naoki Hoshino has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Hideo Izawa
Department of Cardiology, Fujita Health University School of Medicine, Toyoake 470-1192, Japan
5 shared publications Chihiro Nakashima
Department of Cardiology, Cardiovascular Center, Fujita Health University Hospital , Room S1-504, 1-98 Dengaku, Kutsukake, Toyoake
3 shared publicationsKayoko Takada
Department of Cardiology Fujita Health University Toyoake Aichi Japan
3 shared publicationsKunihiko Sugimoto
Clinical Laboratory Fujita Health University Hospital Toyoake Aichi Japan
3 shared publicationsMeiko Hoshino
Department of Cardiology Fujita Health University Toyoake Aichi Japan
3 shared publicationsAkira Yamada
Department of Cardiology, Cardiovascular Center, Fujita Health University Hospital , Room S1-504, 1-98 Dengaku, Kutsukake, Toyoake
2 shared publications
Latest Publications
- 22 June 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (9) , 1658-1670
Prognostic impact of biplane vena contracta width in patients with atrial functional mitral regurgitation
Aims: The vena contracta width (VCW) in parasternal long axis view (PLAX-VCW) and effective regurgitant orifice area (EROA) may underestimate the mitral regurgitation (MR) severity because of the elliptical-shaped effective orifice in atrial functional MR (AFMR). We aimed to assess the association between the vena contracta width by biplane method (Bi-VCW) and clinical outcomes in patients with AFMR and to compare the discriminative ability of Bi-VCW with those of other quantitative/semiquantitative metrics. Methods and results: This was a substudy of a multicentre registry of moderate or severe AFMR. The Bi-VCW was evaluated as the average of the apical two-chamber and four-chamber views. The primary outcome was a composite of all-cause mortality, heart failure hospitalization, and mitral valve interventions. Among 423 studied patients, the Bi-VCW was higher than PLAX-VCW (8.1 ± 2.4 vs. 4.8 ± 1.9 mm, P < 0.001); the guideline-recommended threshold of Bi-VCW of >8.0 mm stratified 48% as severe MR. The Bi-VCW showed the highest discriminatory performance of the primary outcome (area under the time-dependent receiver operating characteristic curve of 0.76) compared with the PLAX-VCW and EROA and revealed an optimal threshold of 7.9 mm (sensitivity, 76%; specificity, 65%). In the multivariable Cox proportional hazards model, Bi-VCW >8.0 mm was independently associated with a higher risk of the primary outcome (adjusted hazard ratio = 2.97, 95% confidence interval: 2.04–4.32, P < 0.001). Conclusion: The Bi-VCW was independently associated with poorer outcomes in patients with AFMR and demonstrated superiority over the guideline-recommended parameters. It could serve as an independent and first surrogate for risk stratification in patients with AFMR.
- 22 June 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 27 (9) , 1658-1670
Prognostic impact of biplane vena contracta width in patients with atrial functional mitral regurgitation
Aims: The vena contracta width (VCW) in parasternal long axis view (PLAX-VCW) and effective regurgitant orifice area (EROA) may underestimate the mitral regurgitation (MR) severity because of the elliptical-shaped effective orifice in atrial functional MR (AFMR). We aimed to assess the association between the vena contracta width by biplane method (Bi-VCW) and clinical outcomes in patients with AFMR and to compare the discriminative ability of Bi-VCW with those of other quantitative/semiquantitative metrics. Methods and results: This was a substudy of a multicentre registry of moderate or severe AFMR. The Bi-VCW was evaluated as the average of the apical two-chamber and four-chamber views. The primary outcome was a composite of all-cause mortality, heart failure hospitalization, and mitral valve interventions. Among 423 studied patients, the Bi-VCW was higher than PLAX-VCW (8.1 ± 2.4 vs. 4.8 ± 1.9 mm, P < 0.001); the guideline-recommended threshold of Bi-VCW of >8.0 mm stratified 48% as severe MR. The Bi-VCW showed the highest discriminatory performance of the primary outcome (area under the time-dependent receiver operating characteristic curve of 0.76) compared with the PLAX-VCW and EROA and revealed an optimal threshold of 7.9 mm (sensitivity, 76%; specificity, 65%). In the multivariable Cox proportional hazards model, Bi-VCW >8.0 mm was independently associated with a higher risk of the primary outcome (adjusted hazard ratio = 2.97, 95% confidence interval: 2.04–4.32, P < 0.001). Conclusion: The Bi-VCW was independently associated with poorer outcomes in patients with AFMR and demonstrated superiority over the guideline-recommended parameters. It could serve as an independent and first surrogate for risk stratification in patients with AFMR.
- Open Access
- 23 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (1)
Suicide left ventricle triggered by accelerated junctional rhythm after transcatheter aortic valve implantation: a case report of rhythm-dependent dynamic left ventricular outflow tract obstruction
Background: Suicide left ventricle (LV) is a rare, potentially fatal complication after transcatheter aortic valve implantation (TAVI). It is typically caused by dynamic left ventricular outflow tract obstruction (LVOTO) following abrupt afterload reduction. Accelerated junctional rhythm (AJR) is an uncommon peri-procedural arrhythmia, and its role in precipitating suicide LV has not been reported. Case summary: An 87-year-old woman with extremely severe aortic stenosis was admitted for transfemoral TAVI. Concentric LV hypertrophy with a sigmoid septum and preserved systolic function was observed on baseline transthoracic echocardiography. She developed profound hypotension immediately after valve deployment. Transoesophageal echocardiography (TOE) revealed severe LVOTO and marked mitral regurgitation (MR) due to systolic anterior motion (SAM) of the mitral valve. The simultaneous appearance of AJR abolished atrial contraction, further reducing LV preload. Left ventricular outflow tract obstruction and SAM resolved during sinus rhythm, but recurred during AJR. Haemodynamics improved with rapid volume loading, vasoconstrictor administration and continuous right ventricular pacing, thereby reducing obstruction via induced ventricular dyssynchrony. Accelerated junctional rhythm resolved spontaneously following emergence from anaesthesia, and a stable sinus rhythm was maintained. The patient was discharged on postoperative Day 12 without recurrence. Discussion: This case reports AJR as a novel trigger for suicide LV after TAVI, leading to preload reduction and promoting SAM, LVOTO, and MR. Intraoperative TOE provided clear rhythm-dependent imaging of LVOT dynamics. Vigilant rhythm monitoring and prompt, targeted haemodynamic management, including pacing to induce ventricular dyssynchrony, are crucial for prevention and treatment in predisposed patients with small, hypertrophied ventricles with a sigmoid septum.
- 23 December 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (1)
Open AccessSuicide left ventricle triggered by accelerated junctional rhythm after transcatheter aortic valve implantation: a case report of rhythm-dependent dynamic left ventricular outflow tract obstruction
Background: Suicide left ventricle (LV) is a rare, potentially fatal complication after transcatheter aortic valve implantation (TAVI). It is typically caused by dynamic left ventricular outflow tract obstruction (LVOTO) following abrupt afterload reduction. Accelerated junctional rhythm (AJR) is an uncommon peri-procedural arrhythmia, and its role in precipitating suicide LV has not been reported. Case summary: An 87-year-old woman with extremely severe aortic stenosis was admitted for transfemoral TAVI. Concentric LV hypertrophy with a sigmoid septum and preserved systolic function was observed on baseline transthoracic echocardiography. She developed profound hypotension immediately after valve deployment. Transoesophageal echocardiography (TOE) revealed severe LVOTO and marked mitral regurgitation (MR) due to systolic anterior motion (SAM) of the mitral valve. The simultaneous appearance of AJR abolished atrial contraction, further reducing LV preload. Left ventricular outflow tract obstruction and SAM resolved during sinus rhythm, but recurred during AJR. Haemodynamics improved with rapid volume loading, vasoconstrictor administration and continuous right ventricular pacing, thereby reducing obstruction via induced ventricular dyssynchrony. Accelerated junctional rhythm resolved spontaneously following emergence from anaesthesia, and a stable sinus rhythm was maintained. The patient was discharged on postoperative Day 12 without recurrence. Discussion: This case reports AJR as a novel trigger for suicide LV after TAVI, leading to preload reduction and promoting SAM, LVOTO, and MR. Intraoperative TOE provided clear rhythm-dependent imaging of LVOT dynamics. Vigilant rhythm monitoring and prompt, targeted haemodynamic management, including pacing to induce ventricular dyssynchrony, are crucial for prevention and treatment in predisposed patients with small, hypertrophied ventricles with a sigmoid septum.
- Open Access
- 19 October 2023
- Published by Wiley in Echocardiography
- Vol. 40 (11) , 1251-1258
Resting echocardiographic parameters can exclude significant coronary artery disease: A comparison with coronary computed tomography angiography
Introduction: Coronary computed tomography angiography (CCTA) is known to have a high negative predictive value (NPV) in identifying coronary artery disease (CAD). This study aimed to examine whether resting echocardiographic parameters could exclude significant CAD on CCTA.Methods: We recruited 142 patients who had undergone both CCTA and echocardiography within a 3-month window. Based on the CCTA findings, patients were divided into two groups: Group A (non-significant CAD, defined as all coronary segments having <50% stenosis) and Group B (significant CAD). Resting echocardiographic parameters were compared between the two groups to identify predictors of non-significant CAD on CCTA.Results: A total 92 patients (mean age, 68 +/- 13 years; males, 62%) were eligible for this study; 50 in Group A and 42 in Group B. Among the various echo parameters, left atrial volume index (LAVI) and left ventricular (LV) global longitudinal strain (GLS) were significantly lower in Group A (23.5 +/- 7.6 vs. 33.6 +/- 7.4 mL/m(2), p < .001; -20.2 +/- 1.8% vs. -16.8 +/- 2.0%, p < .001, respectively). Analysis of the receiver operating characteristic curve revealed that the cutoff value to exclude significant CAD on CCTA was 29.0 mL/m(2) for LAVI (NPV 80.8%) and -18.1% for GLS (NPV 80.7%). The NPV increased to 95.0% when these parameters were combined (LAVI < 29.0 mL/m(2) and GLS < -18.1%).Conclusion: The combination of resting LAVI and GLS was clinically useful in excluding significant CAD via CCTA.
- 19 October 2023
- Published by Wiley in Echocardiography
- Vol. 40 (11) , 1251-1258
Open AccessResting echocardiographic parameters can exclude significant coronary artery disease: A comparison with coronary computed tomography angiography
Introduction: Coronary computed tomography angiography (CCTA) is known to have a high negative predictive value (NPV) in identifying coronary artery disease (CAD). This study aimed to examine whether resting echocardiographic parameters could exclude significant CAD on CCTA.Methods: We recruited 142 patients who had undergone both CCTA and echocardiography within a 3-month window. Based on the CCTA findings, patients were divided into two groups: Group A (non-significant CAD, defined as all coronary segments having <50% stenosis) and Group B (significant CAD). Resting echocardiographic parameters were compared between the two groups to identify predictors of non-significant CAD on CCTA.Results: A total 92 patients (mean age, 68 +/- 13 years; males, 62%) were eligible for this study; 50 in Group A and 42 in Group B. Among the various echo parameters, left atrial volume index (LAVI) and left ventricular (LV) global longitudinal strain (GLS) were significantly lower in Group A (23.5 +/- 7.6 vs. 33.6 +/- 7.4 mL/m(2), p < .001; -20.2 +/- 1.8% vs. -16.8 +/- 2.0%, p < .001, respectively). Analysis of the receiver operating characteristic curve revealed that the cutoff value to exclude significant CAD on CCTA was 29.0 mL/m(2) for LAVI (NPV 80.8%) and -18.1% for GLS (NPV 80.7%). The NPV increased to 95.0% when these parameters were combined (LAVI < 29.0 mL/m(2) and GLS < -18.1%).Conclusion: The combination of resting LAVI and GLS was clinically useful in excluding significant CAD via CCTA.
- 11 February 2022
- Published by Elsevier in Journal of Infection and Chemotherapy
- Vol. 28 (6) , 828-832
Native valve infective endocarditis due to sequence type 97 community-associated methicillin-resistant Staphylococcus aureus complicated by meningitis and multiple septic emboli in a young healthy adult
- 11 February 2022
- Published by Elsevier in Journal of Infection and Chemotherapy
- Vol. 28 (6) , 828-832
Native valve infective endocarditis due to sequence type 97 community-associated methicillin-resistant Staphylococcus aureus complicated by meningitis and multiple septic emboli in a young healthy adult
- 15 January 2022
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 49 (2) , 231-239
Age-related etiologies of aortic regurgitation with moderate or greater severity and coronary cusp bending: evaluation using transesophageal echocardiography
Purpose The prevalence of valvular heart disease has been rising, especially among those ≥ 65 years of age, because of age-related valvular degeneration resulting in an increase in the number of patients diagnosed with aortic regurgitation (AR). We analyzed transesophageal echocardiography (TEE) images in AR patients to identify the etiologies and investigate any differences in them according to age. Methods We studied 146 consecutive patients with chronic moderate or severe AR who underwent TEE. AR etiology was evaluated based on the TEE images in all the patients, as well as in each group separated by age. Results The total number of patients eligible was 126 (mean age 67 ± 12 years), consisting of an older group (n = 85, mean age 74 ± 5 years) and younger group (n = 41, mean age 52 ± 11 years). In total, the most common etiology of AR was cusp bending (33.0%). In the older group, it was the most frequent as well (48.2%), with the right coronary cusp being the most commonly affected site (90.2%). In the younger group, bicuspid aortic valve was the most common (36.5%). Subsequently, all the study subjects were re-classified into two groups according to the presence/absence of cusp bending. Multivariate analysis revealed that age was the only factor associated with cusp bending. Conclusion Cusp bending was the most frequent etiology of AR in the elderly. Preoperative detection of cusp bending by TEE would expand the therapeutic strategy for AR, including aortic valvuloplasty.
- 15 January 2022
- Published by Springer Nature in Journal of Medical Ultrasonics
- Vol. 49 (2) , 231-239
Age-related etiologies of aortic regurgitation with moderate or greater severity and coronary cusp bending: evaluation using transesophageal echocardiography
Purpose The prevalence of valvular heart disease has been rising, especially among those ≥ 65 years of age, because of age-related valvular degeneration resulting in an increase in the number of patients diagnosed with aortic regurgitation (AR). We analyzed transesophageal echocardiography (TEE) images in AR patients to identify the etiologies and investigate any differences in them according to age. Methods We studied 146 consecutive patients with chronic moderate or severe AR who underwent TEE. AR etiology was evaluated based on the TEE images in all the patients, as well as in each group separated by age. Results The total number of patients eligible was 126 (mean age 67 ± 12 years), consisting of an older group (n = 85, mean age 74 ± 5 years) and younger group (n = 41, mean age 52 ± 11 years). In total, the most common etiology of AR was cusp bending (33.0%). In the older group, it was the most frequent as well (48.2%), with the right coronary cusp being the most commonly affected site (90.2%). In the younger group, bicuspid aortic valve was the most common (36.5%). Subsequently, all the study subjects were re-classified into two groups according to the presence/absence of cusp bending. Multivariate analysis revealed that age was the only factor associated with cusp bending. Conclusion Cusp bending was the most frequent etiology of AR in the elderly. Preoperative detection of cusp bending by TEE would expand the therapeutic strategy for AR, including aortic valvuloplasty.
- 16 December 2021
- Published by Elsevier in Journal of Cardiology Cases
- Vol. 25 (5) , 282-284
Thrombosed stuck mitral valve during advanced mechanical circulatory support for post-cardiotomy shock
- 16 December 2021
- Published by Elsevier in Journal of Cardiology Cases
- Vol. 25 (5) , 282-284
Thrombosed stuck mitral valve during advanced mechanical circulatory support for post-cardiotomy shock
- Open Access
- 15 April 2021
- Published by Wiley
Etiologies of Hemodynamically Significant Aortic Regurgitation and Coronary Cusp Bending: Evaluation by Transesophageal Echocardiography
Background: While the number of patients with aortic regurgitation (AR) has been increasing in the aging society, its etiologies remain to be fully elucidated. Methods: We studied consecutive 126 patients with chronic moderate or severe AR who underwent TEE. After the study subjects were divided into 2 groups by the age of 65 years, AR etiology was examined in each group. Results: In the older group (n = 85), cusp bending was the most frequent cause of AR (48.2%), and right coronary cusp (RCC) was the most common (90.2%). In the younger group (n=41), bicuspid valve was the most frequent cause (36.5%), and cusp bending was less frequent (16.5%). Multivariate analysis revealed that age was the only factor associated with cusp bending. Conclusion: Cusp bending of RCC was the most frequent etiology of AR in the elderly. Because AR caused by cusp bending has a possibility to be mended by aortic plasty, it is important to detect it by TEE especially in the older patients.
- 15 April 2021
- Published by Wiley
Open AccessEtiologies of Hemodynamically Significant Aortic Regurgitation and Coronary Cusp Bending: Evaluation by Transesophageal Echocardiography
Background: While the number of patients with aortic regurgitation (AR) has been increasing in the aging society, its etiologies remain to be fully elucidated. Methods: We studied consecutive 126 patients with chronic moderate or severe AR who underwent TEE. After the study subjects were divided into 2 groups by the age of 65 years, AR etiology was examined in each group. Results: In the older group (n = 85), cusp bending was the most frequent cause of AR (48.2%), and right coronary cusp (RCC) was the most common (90.2%). In the younger group (n=41), bicuspid valve was the most frequent cause (36.5%), and cusp bending was less frequent (16.5%). Multivariate analysis revealed that age was the only factor associated with cusp bending. Conclusion: Cusp bending of RCC was the most frequent etiology of AR in the elderly. Because AR caused by cusp bending has a possibility to be mended by aortic plasty, it is important to detect it by TEE especially in the older patients.
- 2 February 2021
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 45 (2) , 227-230
Prophylactic use of vacuum-assisted closure system for cannula sites: A case of extracorporeal biventricular assist devices for 295 days
We report wound management using a vacuum-assisted closure (VAC) system for the cannula sites of extracorporeal biventricular assist devices (BiVADs) for 295 days in a 23-year old Chinese female patient with fulminant giant cell myocarditis, who finally underwent heart transplantation. When the cannula sites appeared necrotic 3 months after BiVADs placement, she received negative pressure wound therapy prophylactically for four cannula sites, using a VAC system for 3 months, followed by no infections. Such prophylactic VAC therapy, using the skin barrier paste usually used for the ostomy pouching system to create a flatter surface and airtightness, may be useful to avoid cannula site infections, which is still a fatal complication causing sepsis, especially in patients with extracorporeal BiVADs.
- 2 February 2021
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 45 (2) , 227-230
Prophylactic use of vacuum-assisted closure system for cannula sites: A case of extracorporeal biventricular assist devices for 295 days
We report wound management using a vacuum-assisted closure (VAC) system for the cannula sites of extracorporeal biventricular assist devices (BiVADs) for 295 days in a 23-year old Chinese female patient with fulminant giant cell myocarditis, who finally underwent heart transplantation. When the cannula sites appeared necrotic 3 months after BiVADs placement, she received negative pressure wound therapy prophylactically for four cannula sites, using a VAC system for 3 months, followed by no infections. Such prophylactic VAC therapy, using the skin barrier paste usually used for the ostomy pouching system to create a flatter surface and airtightness, may be useful to avoid cannula site infections, which is still a fatal complication causing sepsis, especially in patients with extracorporeal BiVADs.