SWSiobhan Wilson

Siobhan Wilson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Siobhan Wilson has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Khosrow Adeli

    Department of Laboratory Medicine and Pathobiology, Faculty of Medicine , University of Toronto , Toronto , ON , Canada

    4 shared publications
  • Alexandra Hall

    CALIPER Program, Department of Pediatric Laboratory Medicine, The Hospital for Sick Children, Toronto, ON, Canada

    3 shared publications
  • Mary Kathryn Bohn

    CALIPER Program, Department of Pediatric Laboratory Medicine, The Hospital for Sick Children, Toronto, ON, Canada

    3 shared publications
  • Hannah Earle

    Department of Laboratory Medicine & Pathobiology, Faculty of Medicine, University of Toronto, Toronto, ON, Canada

    1 shared publication
  • Mary Kathryn Bohn

    Department of Pediatric Laboratory Medicine, the Hospital for Sick Children, Toronto, Ontario, Canada

    1 shared publication
  • Mohamed Abdelhaleem

    CALIPER Program Department of Pediatric Laboratory Medicine The Hospital for Sick Children Toronto ON Canada

    1 shared publication

Latest Publications

  • Open Access

    Comprehensive pediatric reference intervals for 79 hematology markers in the CALIPER cohort of healthy children and adolescents using the Mindray BC‐6800Plus system

    by Mary Kathryn Bohn, Siobhan Wilson, Shannon Steele, Khosrow Adeli

    Background: Hematological parameters vary significantly throughout growth and development due to physiological processes such as fetal‐to‐adult erythropoiesis and puberty. Pediatric age‐ and sex‐specific reference intervals (RIs) are thus essential for appropriate clinical decision‐making. The current study aimed to establish RIs for both common and novel hematology parameters on the Mindray BC‐6800Plus system.Methods: Six hundred and eighty‐seven healthy children and adolescents (30 days to 18 years) were enrolled. Participants were recruited as part of the Canadian Laboratory Initiative on Pediatric Reference Intervals Program upon informed consent or identified from apparently healthy outpatient clinics. Whole blood was collected and assayed for 79 hematology parameters on the BC‐6800Plus system (Mindray). Age‐ and sex‐specific RIs were established as per Clinical and Laboratory Standards Institute EP28‐A3c guidelines.Results: Dynamic reference value distributions were observed for several hematology parameters, including erythrocytes, leukocytes, platelets, reticulocytes, and research‐use‐only markers. Age partitioning was required for 52 parameters, demonstrating changes in infancy and puberty. Sex partitioning was required for 11 erythrocyte parameters (i.e., red blood cell (RBC), hemoglobin, hematocrit, mean corpuscular volume, mean corpuscular hemoglobin concentration, RBC distribution width coefficient of variation, hemoglobin distribution width, macrocyte count, macrocyte percentage, RBC (optical), and reticulocyte production index). Few parameters had undetectable levels in our healthy cohort (i.e., nucleated RBC count and immature granulocyte count).Conclusions: The current study completed hematological profiling for 79 parameters on the BC‐6800Plus system in a healthy cohort of Canadian children and adolescents. These data emphasize the complex biological patterns of hematology parameters in childhood, particularly at the onset of puberty, and support the need for age‐ and sex‐specific RIs for clinical interpretation.


  • Pediatric Reference Intervals for Point-of-Care Random Glucose in Healthy Children and Adolescents

    by Siobhan Wilson, Hannah Earle, Mary Kathryn Bohn, Alexandra Hall, Khosrow Adeli

    Background: Glucose testing at the point-of-care (POC) is routinely used in the diagnosis, prognosis, and monitoring of diabetic states and other clinical conditions. Accurate reference intervals (RIs) are essential in appropriate clinical decision-making. In this study, RIs were established for random glucose (whole blood) in the Canadian Laboratory Initiative on Pediatric Reference (CALIPER) cohort using 2 POC instruments: the Nova Biomedical StatStrip (handheld glucometer) and Radiometer ABL90 FLEX Plus (benchtop instrument). An analytical comparison was also completed between the 2 POC systems and a laboratory-based analyzer (Ortho Vitros 5600). Methods: Approximately 400 healthy children and adolescents (birth to 18 years) were recruited with informed consent from community schools or clinics providing care to metabolically stable/healthy children. Random venous samples were collected and run sequentially on the Nova Biomedical StatStrip (whole blood), Radiometer ABL90 FLEX Plus (whole blood), and Ortho Vitros 5600 (serum). RIs and method comparisons between analytical platforms were completed according to CLSI guidelines. Results: Significantly different glucose concentrations were observed in infancy, requiring age-specific partitioning (0– 0.80). Conclusion: This study established comprehensive pediatric RIs for random glucose (whole blood) on modern POC systems in the CALIPER cohort for the first time. Results demonstrate excellent concordance in glucose values between POC systems and good comparability with a laboratory-based analyzer. These data will assist in more accurate clinical decision-making in pediatric healthcare institutions.


  • Continuous reference curves for common hematology markers in the CALIPER cohort of healthy children and adolescents on the Sysmex XN‐3000 system

    by Siobhan Wilson, Mary Kathryn Bohn, Alexandra Hall, Victoria Higgins, Mohamed Abdelhaleem, Khosrow Adeli

    Introduction: Clinicians and healthcare professionals rely heavily on health‐associated standards, such as reference intervals (RIs), for appropriate laboratory test result interpretation. RIs are commonly partitioned into discrete age/sex bins based on statistical and/or clinical significance. In pediatric hematology, such partitioning does not adequately represent complex variation in analyte concentrations throughout maturation. The objective of this study was to establish continuous RIs for common hematological parameters in the healthy pediatric Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) cohort.Methods: Data from healthy CALIPER children and adolescents (6 months‐<19 years) were used to generate continuous RIs (ie, 2.5th and 97.5th quantiles) for 19 hematological parameters. Continuous curves were statistically established with nonparametric quantile regressions. Flagging rate analysis was completed for the established continuous upper and lower reference limits and subsequently compared to previously published discrete CALIPER reference intervals for all parameters.Results: Continuous RIs were established for 19 hematology parameters, where seven required sex‐specific reference curves. Based on flagging rate assessment, continuous RIs appear to more accurately estimate hematological reference limits over the pediatric age range, especially for analytes with complex age‐ and sex‐specific reference value patterns.Conclusions: This is the first study to generate continuous RIs for a breadth of hematological markers in a healthy pediatric Canadian population. The increased power of continuous reference intervals to accurately estimate the complex relationship between hematological analyte concentration and age during a time of extensive growth and development is expected to improve laboratory test result interpretation and, subsequently, pediatric clinical decision‐making.