SKShubham Kumar

Shubham Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shubham Kumar has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Oxadiazole-based Inhibitors Targeting Carbohydrate-Hydrolyzing Enzymes in Type 2 Diabetes Mellitus: Synthetic Strategies, Structure– Activity Relationships, and Translational Perspectives

    by Shivank Sharma, Shubham Kumar, Pankaj Wadhwa

    Type 2 diabetes mellitus (T2DM) is a multifactorial metabolic disorder characterized by insulin resistance, progressive β-cell dysfunction, and chronic hyperglycemia, leading to microvascular and macrovascular complications. Among current therapeutic strategies, inhibition of intestinal carbohydrate-hydrolyzing enzymes, namely α-amylase and α-glucosidase, represents an established approach for controlling postprandial glucose excursions. However, clinically used inhibitors such as acarbose, miglitol, and voglibose are associated with gastrointestinal intolerance, limited selectivity, and variable efficacy, highlighting the need for improved therapeutic agents. In this context, 1,3,4-oxadiazole-based scaffolds have emerged as promising pharmacophores in antidiabetic drug design. The 1,3,4-oxadiazole ring acts as a bioisostere of amide and ester functionalities, conferring favorable physicochemical properties including enhanced metabolic stability, lipophilicity, and hydrogen-bonding capability. Structure-activity relationship (SAR) studies reported between 2015 and 2025 demonstrate that substituent effects-particularly phenolic hydroxyl groups, halogenation patterns, and extended aromatic systems-play a critical role in optimizing enzyme inhibition through hydrogen bonding, hydrophobic interactions, and π-π stacking within catalytic sites. While several oxadiazole-based hybrids incorporating privileged scaffolds such as benzimidazole, coumarin, and thiazolidinedione have been explored, evidence supporting modulation of additional targets including protein tyrosine phosphatase 1B (PTP1B), aldose reductase (ALR2), and inflammatory pathways such as the NLRP3 inflammasome remains limited and primarily derived from in vitro or computational studies. Computational approaches, including molecular docking, 3D-QSAR, and molecular dynamics simulations, have supported the rational optimization of oxadiazole derivatives, although their predictive limitations should be acknowledged. Despite encouraging preclinical findings, clinical translation remains constrained by insufficient pharmacokinetic, toxicological, and long-term efficacy data. Future research should prioritize systematic ADMET evaluation, standardized biological validation, and mechanistic expansion beyond carbohydrase inhibition to enable the development of clinically viable oxadiazole-based antidiabetic agents.

  • Novel Flexible Organic Photoplethysmogram Sensor for Continuous Cardiovascular Monitoring

    by Shubham Kumar, Rashi Kedia, Arti Bisht, Amit Soni, Ruchi K. Sharma, Sanjay Yadav, Asit Patra, Sanjay K. Srivastava, Ashok Kumar

    A flexible organic photodetector (OPD) has been developed for a flexible organic photoplethysmography sensor (FOPS) designed to monitor vital cardiovascular parameters such as pulse rate, respiratory rate, blood pressure, and pulse rate variability. This device is fabricated on a flexible substrate, utilizing a blend of PCDTBT and PC71BM as the active layer. The FOPS demonstrates excellent absorption properties across the visible spectrum, which is essential for capturing high-quality arterial pulse signals, known as photoplethysmogram (PPG). Optoelectronic characterization revealed a high response time and an impressive on/off current ratio, enabling the accurate detection of microfeatures within the PPG signal. We successfully utilized the device to monitor PPG signals in both reflection and transmission modes, employing green (530 nm) and red (630 nm) light sources, respectively. The recorded PPG signals were further analyzed to measure cardiovascular parameters. The device also demonstrates the ability to measure blood pressure using two techniques: a cuff-based method in conjunction with the oscillometric waveform (OMW) and a cuff-less technique utilizing an artificial neural network approach. These results highlight the FOPS's potential for integration into wearable medical technology, offering continuous, real-time cardiovascular monitoring in a user-friendly and noninvasive manner.


  • Open Access

    Noninvasive Blood Pressure Monitoring via a Flexible and Wearable Piezoresistive Sensor

    by Bijender, Shubham Kumar, Amit Soni, Rimjhim Yadav, Surinder P. Singh, Ashok Kumar

    In the present global context, continuous blood pressure (BP) monitoring is paramount in addressing the global mortality rates attributed to hypertension. Achieving precise insights into the human cardiovascular system necessitates accurate measurement of BP, and the accuracy depends on the faithful recording of oscillations or pulsations. This task ultimately depends on the caliber of the pressure sensor embedded in the BP device. In this context, we have fabricated a flexible resistive pressure sensor based on reduced graphene oxide (rGO) and a polydimethylsiloxane (PDMS) sponge that is highly flexible and sensitive. The designed device operates effectively with a minimal bias voltage of 500 mV, at which point it showed its maximum relative change in current, reaching approximately 25%. Additionally, the sensing device showed a notable change in resistance values, exhibiting almost 100% change in resistance when subjected to a pressure of 400 mmHg and high sensitivity of 0.27 mmHg–1. After promising outcomes were obtained during static pressure measurement, the sensor was used for BP monitoring in humans. The sensor accurately traced the oscillometric waveform (OMW) for distinct systolic blood pressure (SBP) and diastolic blood pressure (DBP) combinations to cover a range of medical situations, including hypotension, standard or normal, and hypertension. The values of SBP, DBP, and MAP were derived from the sensor’s output using the MAA technique, and the errors in these values concerning the simulator and the traditional BP monitor follow the universal AAMI/ESH/ISO protocols. Bland-Altman (B&A) correlation and scatter plots were used to compare the sensor’s results and further validate the proposed sensor. The sensor showed the mean and standard deviation error in the SBP, DBP, and MBP of −0.2 ± 5.9, −0.5 ± 7, and −0.9 ± 4.7 mmHg when compared with the noninvasive blood pressure (NIBP) simulator. The pulse rate (PR) was also calculated from the same OMW for the specified value of 80 beats per minute (bpm) given by the simulator and reported a mean PR value of ∼81 bpm, close to the reference value. The findings show that the flexible resistive sensing device can accurately measure BP and replace the existing sensors of BP devices.


  • Open Access

    Blood pressure measurement techniques, standards, technologies, and the latest futuristic wearable cuff-less know-how

    by Shubham Kumar, Sanjay Yadav, Ashok Kumar

    This review focuses on blood pressure measurement techniques, algorithms, validation standards and recent sensors and technologies to measure arterial pulse.


  • Open Access

    Evaluation of blood pressure using a flexible and wearable capacitive pressure sensor

    by Bijender, Shubham Kumar, Amit Soni, Ashok Kumar

    In recent times, the high demand for flexible and wearable pressure sensors to monitor human health, particularly for patients afflicted with hypertension or high blood pressure (BP), has captured the keen interest of researchers. Capacitance-based flexible sensing devices offer real-time metrics regarding vital physiological parameters of the human body, such as BP and pulse rate (PR), thereby enabling the identification of cardiovascular complications. In this regard, we have developed a capacitive pressure sensor using polydimethylsiloxane (PDMS) and deionized water (DIW) and improved its key parameters by adding baking powder to PDMS-DIW. The sensor demonstrated excellent performance in static pressure measurements with a sensitivity of 0.021 Pa−1, detection limit of 1 Pa, and response time of 100 ms. We further investigated its application in human BP monitoring. The sensor successfully captured the oscillometric waveform (OMW) for all 160 participants and demonstrated excellent performance in accurately measuring BP, meeting all criteria outlined as the universal standard when compared with the reference devices: OMRON BP device and the gold-standard mercury-based sphygmomanometer. Furthermore, the sensor accurately provided the PR and agreed well with the reference BP device. Therefore, the developed BP sensor can be a viable alternative to replace the pressure sensors in existing BP devices.


  • Accuracy of oscillometric-based blood pressure monitoring devices: impact of pulse volume, arrhythmia, and respiratory artifact

    by Shubham Kumar, Sanjay Yadav, Ashok Kumar

    An oscillometric waveform (OMW) envelope-based blood pressure (BP) monitoring device is widely used to monitor blood pressure and prevent hypertension and adverse cardiovascular events. At present, all primary care physicians and clinicians widely recommend oscillometric-based BP devices. The consumer selects the device based on their own decision, without knowing whether the device is validated or not, resulting in over- or under-treatment of hypertension. It is imperative that each device must comply with international protocols. In this study, we have investigated the accuracy of inflation and deflation-based oscillometric BP monitoring devices in the case of sinus rhythm (SR). Since different health conditions of the patient affect the oscillometric waveform, which can affect the device’s accuracy, in such cases, many BP monitors are skeptical of succeeding in the norms of international protocols. Therefore, this study also aims to calculate the accuracy of these devices in various health conditions and measure the effect of pulse volume, arrhythmia, and respiratory artifact on it using a non-invasive blood pressure (NIBP) simulator. We found that the oscillometric BP devices failed to measure the correct blood pressure in several clinical conditions.