Changyun Miao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Changyun Miao has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Cuijuan Guo
Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin, China
1 shared publication D.G. Xu
1 shared publicationD.J. Meng
1 shared publication- Dejun Meng
Tianjin Key Laboratory of Optoelectronic Detection Technology and System, School of Electronic and Information Engineering, Tiangong University, Tianjin 300387, People’s Republic of China
1 shared publication - Donghan Wang
School of Information Science and Technology, Northeast Normal University , 130117 Changchun
1 shared publication - Hongli Chen
State Key Laboratory of Advanced Medical Materials and Devices, Tianjin Key Laboratory of Neuromodulation and Neurorepair, Integrative regeneration laboratory, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences & Peking Union Medical College, Tianjin, China
1 shared publication
Latest Publications
- 8 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 6606-6611
Gas Pressure Sensor With Low Detection Limit Based on Fabry-Perot Interferometer and Intracavity Sensing of Fiber Ring Laser
The measurement of gas pressure with low detection limit is of great significance and remain challenging. In this work, a gas pressure sensing system with a low detection limit is proposed based on Fabry-Perot interferometer and intracavity sensing of fiber ring laser. A miniature pressure-sensitive fiber-optic Fabry-Perot interferometer is fabricated with polyimide film by a 3D printed resin shell. Then, it is coupled in a fiber ring laser. The reflection loss of the Fabry-Perot interferometer is modulated at different gas pressures. With the intracavity gas pressure sensing induced, the gas pressure can be measured by the output power of the fiber ring laser. The detection limit of the gas pressure sensing system has been greatly optimized from 0.155 KPa to 0.01 KPa. The temperature cross-sensitivity and measurement stability of the gas pressure sensing system are also analyzed. The proposed sensing method can be applied to similar sensors to optimize measurement detection limit.
- 8 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 6606-6611
Gas Pressure Sensor With Low Detection Limit Based on Fabry-Perot Interferometer and Intracavity Sensing of Fiber Ring Laser
The measurement of gas pressure with low detection limit is of great significance and remain challenging. In this work, a gas pressure sensing system with a low detection limit is proposed based on Fabry-Perot interferometer and intracavity sensing of fiber ring laser. A miniature pressure-sensitive fiber-optic Fabry-Perot interferometer is fabricated with polyimide film by a 3D printed resin shell. Then, it is coupled in a fiber ring laser. The reflection loss of the Fabry-Perot interferometer is modulated at different gas pressures. With the intracavity gas pressure sensing induced, the gas pressure can be measured by the output power of the fiber ring laser. The detection limit of the gas pressure sensing system has been greatly optimized from 0.155 KPa to 0.01 KPa. The temperature cross-sensitivity and measurement stability of the gas pressure sensing system are also analyzed. The proposed sensing method can be applied to similar sensors to optimize measurement detection limit.
- 1 July 2021
- Published by Elsevier in Optical Fiber Technology
- Vol. 64
A vibration sensor based on Sagnac interferometer and fiber ring laser for fault diagnosis of bearing
- 1 July 2021
- Published by Elsevier in Optical Fiber Technology
- Vol. 64