Christopher Jon Pearce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Christopher Jon Pearce has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Choon Chiet Hong
Department of Orthopaedic Surgery, National University Hospital of Singapore, Singapore
5 shared publications - Soura Saha
Department of Orthopaedic Surgery, National University Hospital, National University Health System, Singapore, Singapore
4 shared publications - Si Heng Sharon Tan
Department of Orthopaedic Surgery, National University Health System, Singapore, Singapore
3 shared publications - Diarmuid Murphy
The Value Driven Outcome Office, National University Health System, Singapore 119228, Singapore
1 shared publication - Joel Xue Yi Lim
Department of Orthopaedic Surgery, National University Hospital, National University Health System, 1E Kent Ridge Road, Singapore 119228, Singapore
1 shared publication - Jun-Hao Tan
National University Spine Institute (NUSI), National University Hospital, Singapore, Singapore
1 shared publication
Latest Publications
- 27 January 2023
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 29 (3) , 228-232
Does a shorter residual first metatarsal length after first ray amputation in diabetic patients leads to poorer outcomes – A risk factor study
- 27 January 2023
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 29 (3) , 228-232
Does a shorter residual first metatarsal length after first ray amputation in diabetic patients leads to poorer outcomes – A risk factor study
- 1 October 2022
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 28 (7) , 891-897
Fibula fixation in the treatment of tibial pilon fractures – Is it really necessary?
- 1 October 2022
- Published by Elsevier in Foot and Ankle Surgery
- Vol. 28 (7) , 891-897
Fibula fixation in the treatment of tibial pilon fractures – Is it really necessary?
- 6 May 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (6) , 2855-2862
Morbidities and prognostic factors after tibial pilon fracture: impact on patients
Introduction This study aims primarily to characterize the sequelae and morbidity associated with tibial pilon injuries from the patients’ perspectives in terms of multiple surgical interventions, duration of hospital stay, downtime from work, loss of productivity and impact on patients’ lives. The secondary aim is to review the associated risk factors for these morbidities. Materials and methods All patients with surgically treated tibial pilon fractures from 1st July 2007 to 30th June 2017 were included. The morbidities reviewed focused on delay to surgery, numbers of surgeries, limb amputation, length of stay (LOS), readmissions, duration of medical leave (ML), follow-up and number of outpatient visits. Results There were 102 patients included in the review and up to 70% of them had an average 7 days delay to definitive surgery. They also required an average hospital LOS of at least 2 weeks extending up to 3 more weeks if soft tissue reconstruction was necessitated. Up to a third of patients were readmitted with 15% of them needing further treatment. These patients required a notable period of downtime from work as shown in the long ML (mean 152.6 days [S.D. = 110.7]). Multiple conditional regression models showed AO/OTA classification (B and C) and open fracture as independent predictors of delay to surgery. Predictors for increased LOS were high velocity mechanism of injury at 4 days longer and patients who needed soft tissue reconstruction at 21 days longer. In terms of downtime from work, only work injury has been identified as an independent predictor of ML at 88.5 days longer. Conclusion Tibial pilon fractures leads to significant morbidities with profound negative impact on patients’ lives in terms of multiple surgical interventions required, prolonged hospital stay, need for readmissions and prolonged downtime from work. These morbidities from patients’ perspective should be emphasized to patients and employers to manage their expectations and potential limitations.
- 6 May 2022
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 143 (6) , 2855-2862
Morbidities and prognostic factors after tibial pilon fracture: impact on patients
Introduction This study aims primarily to characterize the sequelae and morbidity associated with tibial pilon injuries from the patients’ perspectives in terms of multiple surgical interventions, duration of hospital stay, downtime from work, loss of productivity and impact on patients’ lives. The secondary aim is to review the associated risk factors for these morbidities. Materials and methods All patients with surgically treated tibial pilon fractures from 1st July 2007 to 30th June 2017 were included. The morbidities reviewed focused on delay to surgery, numbers of surgeries, limb amputation, length of stay (LOS), readmissions, duration of medical leave (ML), follow-up and number of outpatient visits. Results There were 102 patients included in the review and up to 70% of them had an average 7 days delay to definitive surgery. They also required an average hospital LOS of at least 2 weeks extending up to 3 more weeks if soft tissue reconstruction was necessitated. Up to a third of patients were readmitted with 15% of them needing further treatment. These patients required a notable period of downtime from work as shown in the long ML (mean 152.6 days [S.D. = 110.7]). Multiple conditional regression models showed AO/OTA classification (B and C) and open fracture as independent predictors of delay to surgery. Predictors for increased LOS were high velocity mechanism of injury at 4 days longer and patients who needed soft tissue reconstruction at 21 days longer. In terms of downtime from work, only work injury has been identified as an independent predictor of ML at 88.5 days longer. Conclusion Tibial pilon fractures leads to significant morbidities with profound negative impact on patients’ lives in terms of multiple surgical interventions required, prolonged hospital stay, need for readmissions and prolonged downtime from work. These morbidities from patients’ perspective should be emphasized to patients and employers to manage their expectations and potential limitations.
- 16 April 2021
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (11) , 2999-3007
Should the location of distal tibial plating be influenced by the varus or valgus fracture pattern of tibial pilon fracture?
Introduction Operative treatment of tibial pilon fracture is challenging. There is a lack of consensus and only one clinical study on the optimal location of distal tibial plating for fixation of pilon fractures based on varus or valgus fracture patterns. We hypothesize that complications rates, specifically mechanical complications, are not influenced by the location of the tibial plating in the fixation of pilon fractures with respect to varus or valgus fracture patterns. Materials and methods Sixty-nine patients who had single plating for tibial pilon from 2007 to 2017 were recruited. They were divided into two groups, transverse fibular fracture (varus fracture pattern) and comminuted fibular fracture (valgus fracture pattern). Our primary outcome measure was any mechanical complications as a result of the location of plating (medial vs lateral) on varus or valgus fracture patterns. Results There were 38 (55.1%) patients with varus fracture pattern and 31 (44.9%) patients with valgus fracture pattern tibial pilon fractures. In the varus fracture pattern group, mechanical complications were not significantly different between the two plating locations (27.3 vs 33.3%, p > 0.05). Notably, there were more fibula fixations performed in patients with medial plating (74.1 vs 45.5%, p = 0.092) when compared those with lateral plating in the varus fracture pattern group. There were also no statistically significant differences found although 10 (40%) out of 25 patients had mechanical complications in the medial plating group compared to 1 (16.7%) out of 6 patients with lateral plating (p = 0.383) in the valgus fracture pattern group. Conclusion There were no differences in mechanical complications for medial vs lateral plating in tibial pilon fracture based on varus or valgus deforming forces. As much as we should consider the fracture patterns and deforming forces when deciding on plating location, other factors such as careful soft tissue management and fragment-specific fixation should be prioritized.
- 16 April 2021
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 142 (11) , 2999-3007
Should the location of distal tibial plating be influenced by the varus or valgus fracture pattern of tibial pilon fracture?
Introduction Operative treatment of tibial pilon fracture is challenging. There is a lack of consensus and only one clinical study on the optimal location of distal tibial plating for fixation of pilon fractures based on varus or valgus fracture patterns. We hypothesize that complications rates, specifically mechanical complications, are not influenced by the location of the tibial plating in the fixation of pilon fractures with respect to varus or valgus fracture patterns. Materials and methods Sixty-nine patients who had single plating for tibial pilon from 2007 to 2017 were recruited. They were divided into two groups, transverse fibular fracture (varus fracture pattern) and comminuted fibular fracture (valgus fracture pattern). Our primary outcome measure was any mechanical complications as a result of the location of plating (medial vs lateral) on varus or valgus fracture patterns. Results There were 38 (55.1%) patients with varus fracture pattern and 31 (44.9%) patients with valgus fracture pattern tibial pilon fractures. In the varus fracture pattern group, mechanical complications were not significantly different between the two plating locations (27.3 vs 33.3%, p > 0.05). Notably, there were more fibula fixations performed in patients with medial plating (74.1 vs 45.5%, p = 0.092) when compared those with lateral plating in the varus fracture pattern group. There were also no statistically significant differences found although 10 (40%) out of 25 patients had mechanical complications in the medial plating group compared to 1 (16.7%) out of 6 patients with lateral plating (p = 0.383) in the valgus fracture pattern group. Conclusion There were no differences in mechanical complications for medial vs lateral plating in tibial pilon fracture based on varus or valgus deforming forces. As much as we should consider the fracture patterns and deforming forces when deciding on plating location, other factors such as careful soft tissue management and fragment-specific fixation should be prioritized.