Fritz Kalwa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fritz Kalwa has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Aaron Peche
Federal Institute for Geosciences and Natural Resources (BGR), Hannover, Lower Saxony, Germany
1 shared publication - Falk Händel
Technische Universität Dresden
1 shared publication - Georg J. Houben
Federal Institute for Geosciences and Natural Resources (BGR), Hannover, Germany
1 shared publication - José David Henao Casas
Universidad Politécnica de Madrid
1 shared publication Luzie Grüneberg
Institute of Groundwater Management Technische Universität Dresden Bergstraße 66 01069 Dresden Germany
1 shared publication- Marc Walther
Chair of Forest Biometrics and Forest Systems Analysis, Department of Forest Sciences, Faculty of Environmental Sciences, Technische Universität Dresden, 01062 Dresden, Germany
1 shared publication
Latest Publications
- Open Access
- 2 June 2026
- Published by Wiley in Groundwater
- Vol. 64 (4) , 483-497
Leaky Sewers Hydraulically Disconnect from Groundwater: A Proof‐of‐Concept
Leakage from aging sewer and stormwater pipes into the subsurface poses significant environmental risks and threatens the integrity of urban infrastructure, primarily through the degradation of groundwater quality and the alteration of urban water balances. While the presence of defects within pipe networks is well‐documented, accurately quantifying volumetric exchange fluxes remains a challenge due to the complex, nonlinear interactions between the pipe, the surrounding variably saturated soil, and the fluctuating groundwater level. Current modeling approaches often overlook the threshold behaviors of these systems, leading to potential inaccuracies in leakage estimation. In this study, we show for the first time that leaky pipes can become hydraulically disconnected from the underlying groundwater, a phenomenon analogous to well‐known river–groundwater interactions that include disconnection. In a sewer–groundwater context, hydraulic disconnection is restricted to point sources and is strongly influenced by colmation/clogging. Through numerical modeling of a hypothetical case study, we show that the leakage flux from the pipe (in absolute terms) initially increases with declining groundwater levels, until a critical depth below the leaky pipe is reached. After this point, the hydraulic communication from the groundwater to the leaky pipe stops and the leakage flux can be considered constant. In a sensitivity analysis, we demonstrate the impact of the individual hydraulic parameters of the leaky‐pipe‐groundwater system on the hydraulic disconnection. We further modify the properties of the aquifer material, resulting in a hydraulic disconnection depth of 0.89 m, 1.77 m and 4.00 m below pipe for sand, loamy sand and sandy loam aquifers, respectively. This insight has important implications for leakage modeling: once hydraulic disconnection occurs, the leakage flux becomes independent of groundwater dynamics. The present study provides a proof‐of‐concept for the mechanism by which leaky sewers hydraulically disconnect from groundwater.
- 2 June 2026
- Published by Wiley in Groundwater
- Vol. 64 (4) , 483-497
Open AccessLeaky Sewers Hydraulically Disconnect from Groundwater: A Proof‐of‐Concept
Leakage from aging sewer and stormwater pipes into the subsurface poses significant environmental risks and threatens the integrity of urban infrastructure, primarily through the degradation of groundwater quality and the alteration of urban water balances. While the presence of defects within pipe networks is well‐documented, accurately quantifying volumetric exchange fluxes remains a challenge due to the complex, nonlinear interactions between the pipe, the surrounding variably saturated soil, and the fluctuating groundwater level. Current modeling approaches often overlook the threshold behaviors of these systems, leading to potential inaccuracies in leakage estimation. In this study, we show for the first time that leaky pipes can become hydraulically disconnected from the underlying groundwater, a phenomenon analogous to well‐known river–groundwater interactions that include disconnection. In a sewer–groundwater context, hydraulic disconnection is restricted to point sources and is strongly influenced by colmation/clogging. Through numerical modeling of a hypothetical case study, we show that the leakage flux from the pipe (in absolute terms) initially increases with declining groundwater levels, until a critical depth below the leaky pipe is reached. After this point, the hydraulic communication from the groundwater to the leaky pipe stops and the leakage flux can be considered constant. In a sensitivity analysis, we demonstrate the impact of the individual hydraulic parameters of the leaky‐pipe‐groundwater system on the hydraulic disconnection. We further modify the properties of the aquifer material, resulting in a hydraulic disconnection depth of 0.89 m, 1.77 m and 4.00 m below pipe for sand, loamy sand and sandy loam aquifers, respectively. This insight has important implications for leakage modeling: once hydraulic disconnection occurs, the leakage flux becomes independent of groundwater dynamics. The present study provides a proof‐of‐concept for the mechanism by which leaky sewers hydraulically disconnect from groundwater.
- Open Access
- 25 October 2023
- Published by Springer Nature in Hydrogeology Journal
- Vol. 32 (2) , 635-643
Can wells in the vadose zone be backflushed to regain infiltration capacity? Concept and laboratory test
Vadose zone wells (VZW), or drywells, allow for high infiltration rates combined with small area demand. Nevertheless, they are rarely used for managed aquifer recharge, since turbid water leads to gradual clogging and a reduction in infiltration capacity. Established redevelopment measures require backflushing, which is commonly considered impossible for VZWs, making them “non regenerable”. In this study, the possibility of backflushing a VZW is discussed. Key to the underlying approach is isolating the lower (clogged) section of a well and saturating its surrounding with water by infiltration via the upper (unclogged) screen. Subsequently, underpressure sucks water from the surrounding soil into the isolated section. The approach was tested with and without a gravel pack, on laboratory scale, showing a successful reversal of flow direction in both cases. The degree of redevelopment was quantified by measuring the drainage time of the well, which increased from initially 45 s without gravel pack and 40 s with gravel pack to 9,500 and 11,000 s, respectively, after clogging. After backflushing, the well with gravel pack showed a median drainage time of 95 s, which remained stable over ten cycles of clogging and backflushing. In contrast, drainage time of the well without gravel pack increased continuously to >170 s, even after vibrator application. In conclusion, it can be stated that the backflush of a VZW with the presented approach is possible and has an effect on the well’s infiltration capacity, though it seems more effective for wells with gravel pack.
- 25 October 2023
- Published by Springer Nature in Hydrogeology Journal
- Vol. 32 (2) , 635-643
Open AccessCan wells in the vadose zone be backflushed to regain infiltration capacity? Concept and laboratory test
Vadose zone wells (VZW), or drywells, allow for high infiltration rates combined with small area demand. Nevertheless, they are rarely used for managed aquifer recharge, since turbid water leads to gradual clogging and a reduction in infiltration capacity. Established redevelopment measures require backflushing, which is commonly considered impossible for VZWs, making them “non regenerable”. In this study, the possibility of backflushing a VZW is discussed. Key to the underlying approach is isolating the lower (clogged) section of a well and saturating its surrounding with water by infiltration via the upper (unclogged) screen. Subsequently, underpressure sucks water from the surrounding soil into the isolated section. The approach was tested with and without a gravel pack, on laboratory scale, showing a successful reversal of flow direction in both cases. The degree of redevelopment was quantified by measuring the drainage time of the well, which increased from initially 45 s without gravel pack and 40 s with gravel pack to 9,500 and 11,000 s, respectively, after clogging. After backflushing, the well with gravel pack showed a median drainage time of 95 s, which remained stable over ten cycles of clogging and backflushing. In contrast, drainage time of the well without gravel pack increased continuously to >170 s, even after vibrator application. In conclusion, it can be stated that the backflush of a VZW with the presented approach is possible and has an effect on the well’s infiltration capacity, though it seems more effective for wells with gravel pack.
- Open Access
- 19 April 2021
- Published by Springer Nature in Hydrogeology Journal
- Vol. 29 (5) , 1813-1830
Stormwater harvesting in ephemeral streams: how to bypass clogging and unsaturated layers
To cope with water scarcity in drylands, stormwater is often collected in surface basins and subsequently stored in shallow aquifers via infiltration. These stormwater harvesting systems are often accompanied by high evaporation rates and hygiene problems. This is commonly a consequence of low infiltration rates, which are caused by clogging layers that form on top of the soil profile and the presence of a thick vadose zone. The present study aims to develop a conceptual solution to increase groundwater recharge rates in stormwater harvesting systems. The efficiency of vadose-zone wells and infiltration trenches is tested using analytical equations, numerical models, and sensitivity analyses. Dams built in the channel of ephemeral streams (wadis) are selected as a study case to construct the numerical simulations. The modelling demonstrated that vadose-zone wells and infiltration trenches contribute to effective bypassing of the clogging layer. By implementing these solutions, recharge begins 2250–8100% faster than via infiltration from the bed surface of the wadi reservoir. The sensitivity analysis showed that the recharge rates are especially responsive to well length and trench depth. In terms of recharge quantity, the well had the best performance; it can infiltrate up to 1642% more water than the reservoir, and between 336 and 825% more than the trench. Moreover, the well can yield the highest cumulative recharge per dollar and high recharge rates when there are limitations to the available area. The methods investigated here significantly increased recharge rates, providing practical solutions to enhance aquifer water storage in drylands.
- 19 April 2021
- Published by Springer Nature in Hydrogeology Journal
- Vol. 29 (5) , 1813-1830
Open AccessStormwater harvesting in ephemeral streams: how to bypass clogging and unsaturated layers
To cope with water scarcity in drylands, stormwater is often collected in surface basins and subsequently stored in shallow aquifers via infiltration. These stormwater harvesting systems are often accompanied by high evaporation rates and hygiene problems. This is commonly a consequence of low infiltration rates, which are caused by clogging layers that form on top of the soil profile and the presence of a thick vadose zone. The present study aims to develop a conceptual solution to increase groundwater recharge rates in stormwater harvesting systems. The efficiency of vadose-zone wells and infiltration trenches is tested using analytical equations, numerical models, and sensitivity analyses. Dams built in the channel of ephemeral streams (wadis) are selected as a study case to construct the numerical simulations. The modelling demonstrated that vadose-zone wells and infiltration trenches contribute to effective bypassing of the clogging layer. By implementing these solutions, recharge begins 2250–8100% faster than via infiltration from the bed surface of the wadi reservoir. The sensitivity analysis showed that the recharge rates are especially responsive to well length and trench depth. In terms of recharge quantity, the well had the best performance; it can infiltrate up to 1642% more water than the reservoir, and between 336 and 825% more than the trench. Moreover, the well can yield the highest cumulative recharge per dollar and high recharge rates when there are limitations to the available area. The methods investigated here significantly increased recharge rates, providing practical solutions to enhance aquifer water storage in drylands.
- Open Access
- 9 April 2021
- Published by Wiley in Groundwater
- Vol. 59 (6) , 819-828
Biological and Physical Clogging in Infiltration Wells: Effects of Well Diameter and Gravel Pack
Gravity‐driven infiltration into the shallow subsurface via small‐diameter wells (SDWs), i.e., wells with an inner diameter smaller than 7.5 cm (3 inches) and no gravel pack) has proven to be a cost‐efficient and flexible tool for managed aquifer recharge (MAR), as it provides relatively high recharge rates with minimal construction effort. SDWs have a significantly smaller open filter area than larger diameter wells with gravel pack, making the infiltration of low‐quality waters through these wells more at risk clogging. To investigate their susceptibility for biological and physical clogging, 24 physical models with different well setups were evaluated by infiltrating either nutrient‐poor but turbid water or nutrient‐rich but clear water. The experiments showed that smaller diameters and the lack of a gravel pack increase the well's susceptibility to both kinds of clogging. However, this effect was observed to be much more pronounced for physical than for biological clogging. Our conclusion is that SDWs show severe disadvantages with respect to the infiltration of highly turbid waters in comparison to large diameter wells with a gravel pack. Nevertheless, this disadvantage is much less severe when it comes to the infiltration of clear but nutrient‐rich waters (e.g., treated wastewater). Depending on the economic and geological circumstances of a MAR‐project, this disadvantage could be outweighed by the significantly lower construction costs of SDWs.
- 9 April 2021
- Published by Wiley in Groundwater
- Vol. 59 (6) , 819-828
Open AccessBiological and Physical Clogging in Infiltration Wells: Effects of Well Diameter and Gravel Pack
Gravity‐driven infiltration into the shallow subsurface via small‐diameter wells (SDWs), i.e., wells with an inner diameter smaller than 7.5 cm (3 inches) and no gravel pack) has proven to be a cost‐efficient and flexible tool for managed aquifer recharge (MAR), as it provides relatively high recharge rates with minimal construction effort. SDWs have a significantly smaller open filter area than larger diameter wells with gravel pack, making the infiltration of low‐quality waters through these wells more at risk clogging. To investigate their susceptibility for biological and physical clogging, 24 physical models with different well setups were evaluated by infiltrating either nutrient‐poor but turbid water or nutrient‐rich but clear water. The experiments showed that smaller diameters and the lack of a gravel pack increase the well's susceptibility to both kinds of clogging. However, this effect was observed to be much more pronounced for physical than for biological clogging. Our conclusion is that SDWs show severe disadvantages with respect to the infiltration of highly turbid waters in comparison to large diameter wells with a gravel pack. Nevertheless, this disadvantage is much less severe when it comes to the infiltration of clear but nutrient‐rich waters (e.g., treated wastewater). Depending on the economic and geological circumstances of a MAR‐project, this disadvantage could be outweighed by the significantly lower construction costs of SDWs.