KLKevin M. Labus

Kevin M. Labus

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kevin M. Labus has a total of 58 co-authors. Here are the top co-authors by number of shared publications:

  • Christian M. Puttlitz

    School of Biomedical Engineering, Colorado State University, Fort Collins, CO 80523, USA

    6 shared publications
  • Benjamin C. Gadomski

    Department of Mechanical Engineering Orthopaedic Bioengineering Research Laboratory, CSU Fort Collins Colorado USA

    5 shared publications
  • Jeremiah T. Easley

    Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO

    4 shared publications
  • Bradley B. Nelson

    Orthopaedic Research Center, Translational Medicine Institute, Department of Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, CO

    2 shared publications
  • Christian M. Puttlitz

    Department of Mechanical Engineering and School of Biomedical and Chemical Engineering, Colorado State University, Fort Collins, CO, USA; Department of Clinical Sciences, Colorado State University, Fort Collins, CO, USA

    2 shared publications
  • Daniel P. Regan

    Department of Microbiology, Immunology, and Pathology, Colorado State University, Fort Collins, Colorado, USA

    2 shared publications

Latest Publications

  • Open Access

    Can a 3D Printed Chondrograft Implant Offer a Solution for Full Thickness Cartilage Lesions in an Equine Preclinical Model?

    by Charlotte K. Barton, Kathryn A. Seabaugh, Benjamin C. Gadomski, Kevin M. Labus, Benjamin B. Holmes, Nathan J. Castro, Michael L. Hawes, Brad B. Nelson, Laurie R. Goodrich

    Articular cartilage defects have limited ability to heal resulting in fibrocartilage that is functionally and structurally inferior to hyaline cartilage. The aim of this study was to validate the Chondrograft Implant for full thickness cartilage lesion treatment, assessing its ability to fill the defect and support repair tissue engraftment. Bilateral 15 mm diameter cartilage defects were created on the lateral trochlear ridge of the femur in 12 skeletally mature horses. One defect was treated with the implant while the contralateral limb was an empty control defect. Horses were exercised starting at week 4 and study end points were at 36‐weeks for 4 horses and 52‐weeks for 8 horses. Lameness examinations were performed every 4 weeks and arthroscopic recheck surgeries were performed at 12‐weeks. Post‐mortem evaluation included macroscopic appearance, MRI, histology and biomechanical testing. Clinical, ICRS, MRI and gross morphology outcomes were compared between groups using parametric or non‐parametric tests as appropriate. Mechanical stiffness was compared between groups using two‐way ANOVA with Tukey's post‐hoc. There was no difference in lameness between control or treated limbs ( p > 0.5). The 12‐week arthroscopy showed treated defects had significantly improved fill (99% vs 42%, p < 0.0001) and ICRS scores (11.3 ± 1.1 vs 4.1 ± 3.1, p < 0.0001). Endpoint ICRS grade at 52‐ weeks was significantly better in the treated defect compared to the control defect scoring (3.75 ± 2.25 vs 9.125 ± 2.25, p = 0.0005). Biomechanical testing revealed significantly improved repair tissue stiffness in treated defects compared to controls ( p < 0.0001). Chondrograft implants resulted in excellent defect filling with biomechanical function similar to normal healthy articular cartilage.

  • Open Access

    Evaluation of Tendon Fastener Designed for Percutaneous Placement in an Ovine Model for Repair of Articular-Sided Rotator Cuff Tears

    by Mark Miller, Adam Kohring, Tiffany Bridges, Benjamin C. Gadomski, Kevin Labus, Daniel Regan, Jeremiah Easley, Drew W. Koch, Ashley Potter, William B. Morrison

    Introduction: Surgical treatment for partial-thickness rotator cuff tendon (RCT) tears often involves open or arthroscopic conversion to a full-thickness tear. A novel method has been developed that utilizes sutureless bone-to-tendon fixation using a percutaneous fastener. Purpose: This study characterizes the biomechanical stability of the fastener in a partial-tear ovine rotator cuff model compared to that of a screw-and-washer. Methods: The study included an ex vivo cadaveric phase and an in vivo pilot. During the ex vivo phase, the infraspinatus tendon was partially transected in 20 cadaveric sheep shoulders. Shoulders were allocated into three groups: fastener (FS) (n = 10), screw-and-washer (S/W) (n = 7), and an empty group without fixation (n = 3). In an in vivo pilot, three sheep underwent bilateral partial infraspinatus transection and repair, with the fastener in one shoulder and the screw-and-washer in the contralateral shoulder; animals were euthanized at 8 weeks for histological analysis. Both cohorts underwent biomechanical assessments, and the in vivo samples underwent histological dissection and analysis. Results: No significant biomechanical differences were noted among the three groups in ultimate load (FS: 2822 N, S/W: 2599 N, empty: 2924 N), ultimate displacement (FS: 15.9 mm, S/W: 15.5 mm, empty: 13.8 mm), stiffness (FS: 252.4 N/mm, S/W: 237.7 N/mm, empty: 279.9 N/mm), cross-sectional area (FS: 90.0 mm2, S/W: 93.0 mm2, empty: 78.8 mm2), ultimate stress (FS: 32.9 MPa, S/W: 28.3 MPa, empty: 37.8 MPa), ultimate strain (FS: 0.203 mm/mm, S/W: 0.183 mm/mm, empty: 0.183 mm/mm), or elastic modulus (FS: 231.1 MPa, S/W: 220.3 MPa, empty: 271.3 MPa). The mode of failure was most frequently a mid-substance tear. Both the fastener and the screw-and-washer demonstrated comparable histology across the graded parameters regardless of the evaluated animal or sample. Conclusions: The fastener offers similar biomechanical stability to that of a screw-and-washer construct in the treatment of partial rotator cuff tears in an ovine model. Clinical Relevance: The results of this animal model study provide evidence to consider further clinical testing.

  • Remote monitoring of bone healing via bending with direct electromagnetic coupling sensing in an exploratory tibial fracture study

    by Kevin M. Labus, Julie Dunn, Milan Ilić, Branislav M. Notaroš, Kirk C. McGilvray, Christian M. Puttlitz


  • Open Access

    Annealed Polyvinyl Alcohol Hydrogels for Cartilage Replacement: Effects of Synthesis Parameters on Mechanical Properties

    by Hassan Mahmoud, Christian M. Puttlitz, Benjamin C. Gadomski, Kevin M. Labus

    The objective of this paper was to determine the interactive effects of multiple synthesis parameters on annealed PVA hydrogel properties and assess these hydrogels for the application of cartilage replacement. PVA hydrogels were synthesized at two different molecular weight ranges (89–98 kDa and 146–186 kDa), two polymer concentrations (10% PVA and 20% PVA), and four different annealing temperatures (120 °C, 135 °C, 150 °C, and 165 °C). The compressive, tensile, and wear mechanical properties were measured, and the crystalline structure of these hydrogels was assessed via differential scanning calorimetry. Hydrogels showed increasing polymer weight percent, tensile modulus, and compressive modulus with increasing annealing temperature. Depending on synthesis parameters, the hydrogels matched or exceeded the previously published compressive and tensile properties of native cartilage. Higher molecular weight PVA hydrogels (146–186 kDa) exhibited less wear, but greater friction, compared to lower molecular weight PVA (89–98 kDa). The PVA hydrogels exhibited crystallinity in the range of 53–78%, but no consistent differences in crystallinity were detected between hydrogel variants. It was concluded that the (10% PVA, 146 kDa, 165 °C) annealed PVA hydrogel demonstrated the most appropriate balance of high tensile strength and compressive compliance comparable to cartilage.


  • Open Access

    Regeneration of Biomechanically Functional Tendon Tissue Following Injection of Uncultured, Autologous, Adipose-Derived Regenerative Cells into Partial Achilles Tendon Defects in Rabbits

    by Christoph Schmitz, Christopher Alt, Tobias Wuerfel, Stefan Milz, Jacqueline Dinzey, Ashley Hill, Katie J. Sikes, Lindsey H. Burton, Jeremiah Easley, Holly L. Stewart, et al.

    Current treatment strategies for partial tendon tears often lack the capacity to promote true tissue regeneration and improve long-term clinical outcomes. This study tested the hypothesis that treatment of a partial defect in the rabbit common calcaneus tendon (CCT) with uncultured, unmodified, autologous, adipose-derived regenerative cells (UA-ADRCs) enables regenerative healing without scar formation. A full-thickness, 3 mm defect was produced in the midsubstance of the right gastrocnemius tendon, a component of the CCT, in adult female New Zealand white rabbits. Animals received either an injection of 28.3 × 106 UA-ADRCs in 0.5 mL Ringer’s lactated solution (RLS) or saline, or RLS or saline alone as sham treatment. Tendons were analyzed 4 or 12 weeks post-treatment using histology, immunohistochemistry and non-destructive biomechanical testing. UA-ADRC-treated tendons showed newly formed connective tissue consistent with tendon regeneration, whereas sham-treated tendons developed scar tissue. Biomechanical testing showed significantly higher percent relaxation in UA-ADRC-treated tendons compared to sham controls (p < 0.05), indicating greater viscoelasticity characteristic of healthy or well-integrated tissue. Together, these findings suggest that UA-ADRC therapy may provide a regenerative, structure-modifying treatment for partial tendon tears.


  • Open Access

    A mechanical evaluation of polyvinyl alcohol hydrogels for temporomandibular joint disc replacement

    by Jason P. Kuiper, Christian M. Puttlitz, Jennifer E. Rawlinson, Ryan Dobbs, Kevin M. Labus

    The temporomandibular joint (TMJ) is a bilateral ginglymoarthroidal joint containing a fibrocartilaginous disc which distributes compressive stress and reduces friction on the articulating surfaces of the joint. Initially, conservative treatments can address disorders of the TMJ, but surgical procedures such as discectomy may be employed if dysfunction persists. Unfortunately, discectomy increases friction and alters the mechanical behavior of the TMJ when the disc is not replaced. An ideal replacement for the TMJ disc would restore healthy function of the joint and prevent further degeneration. Rigorous evaluation of materials is necessary to ensure the safety and efficacy of novel implants. Poly(vinyl) alcohol (PVA) hydrogels have been suggested as a good candidate for artificial cartilage replacement in other applications and are promising for replacing the TMJ disc due to their biocompatibility, low friction, and biomimetic levels of hydration. The objective of this study was to mechanically characterize hydrogel formulations of 15, 20, and 25% PVA and to compare them with the ovine TMJ disc to investigate the appropriateness of PVA hydrogels for TMJ disc replacement in a translational model. Experimental evaluations were conducted in indentation, unconfined compression, friction, and uniaxial tension. There were no statistically significant differences in the coefficient of friction between the PVA hydrogels and ovine TMJ disc. No statistically significant differences were found between at least one PVA hydrogel group and the TMJ disc for the indentation properties or the unconfined compression properties at low stretch magnitudes. The 20% PVA and 25% PVA hydrogels exhibited significantly higher failure stretch as compared to the ovine TMJ disc, and they were not statistically different in ultimate tensile strength from the TMJ disc in the mediolateral direction. However, the ovine TMJ disc tensile elastic moduli were 630 times larger in the anteroposterior direction and 53 times larger in the mediolateral direction than the stiffest PVA hydrogel. Ultimately, the 25% PVA hydrogel was the best candidate for TMJ disc replacement, demonstrating the most similarity to the ovine TMJ disc compressive properties; however, tensile reinforcement of the hydrogels would be necessary to approach the tensile modulus of the native TMJ disc.


  • Open Access

    The Interventricular Septum Is Biomechanically Distinct from the Ventricular Free Walls

    by Michael Nguyen-Truong, Wenqiang Liu, Courtney Doherty, Kristen LeBar, Kevin M. Labus, Christian M. Puttlitz, Jeremiah Easley, Eric Monnet, Adam Chicco, Zhijie Wang

    The interventricular septum contributes to the pumping function of both ventricles. However, unlike the ventricular wall, its mechanical behavior remains largely unknown. To fill the knowledge gap, this study aims to characterize the biaxial and transmural variation of the mechanical properties of the septum and compare it to the free walls of the left and right ventricles (LV/RV). Fresh hearts were obtained from healthy, adult sheep. The septal wall was sliced along the mid-line into two septal sides and compared to the epicardial layers of the LV- and RV-free walls. Biaxial tensile mechanical tests and constitutive modeling were performed to obtain the passive mechanical properties of the LV- and RV-side of the septum and ventricular walls. We found that both sides of the septum were significantly softer than the respective ventricular walls, and that the septum presented significantly less collagen than the ventricular walls. At low strains, we observed the symmetric distribution of the fiber orientations and a similar anisotropic behavior between the LV-side and RV-side of the septum, with a stiffer material property in the longitudinal direction, rather than the circumferential direction. At high strains, both sides showed isotropic behavior. Both septal sides had similar intrinsic elasticity, as evidenced by experimental data and constitutive modeling. These new findings offer important knowledge of the biomechanics of the septum wall, which may deepen the understanding of heart physiology.


  • Investigation of a Prevascularized Bone Graft for Large Defects in the Ovine Tibia

    by Yunzhi Peter Yang, Benjamin C. Gadomski, Arnaud Bruyas, Jeremiah T Easley, Kevin M. Labus, Brad Nelson, Ross H. Palmer, Holly Stewart, Kirk McGilvray, Christian M. Puttlitz, et al.

    In vivo bioreactors are a promising approach for engineering vascularized autologous bone grafts to repair large bone defects. In this pilot parametric study, we first developed a 3D printed scaffold uniquely designed to accommodate inclusion of a vascular bundle and facilitate growth factor delivery for accelerated vascular invasion and ectopic bone formation. Second, we established a new sheep deep circumflex iliac artery (DCIA) model as an in vivo bioreactor for engineering a vascularized bone graft and evaluated the effect of implantation duration on ectopic bone formation. Third, after 8 weeks of implantation around the DCIA, we transplanted the prevascularized bone graft to a 5 cm segmental bone defect in the sheep tibia, using the custom 3D printed BMP-2 loaded scaffold without prior in vivo bioreactor maturation as a control. Analysis by micro-computed tomography and histomorphometry found ectopic bone formation in BMP-2 loaded scaffolds implanted for 8 and 12 weeks in the iliac pouch, with greater bone formation occurring after 12 weeks. Grafts transplanted to the tibial defect supported bone growth, mainly on the periphery of the graft, but greater bone growth and less soft tissue invasion was observed in the avascular BMP-2 loaded scaffold implanted directly into the tibia without prior in vivo maturation. Histopathological evaluation noted considerably greater vascularity in the bone grafts that underwent in vivo maturation with an inserted vascular bundle compared to the avascular BMP-2 loaded graft. Our findings indicate that use of an initial DCIA in vivo bioreactor maturation step is a promising approach to developing vascularized autologous bone grafts, although scaffolds with greater osteoinductivity should be further studied.


  • Different Passive Viscoelastic Properties Between the Left and Right Ventricles in Healthy Adult Ovine

    by Wenqiang Liu, Michael Nguyen-Truong, Matt Ahern, Kevin M. Labus, Christian M. Puttlitz, Zhijie Wang

    Ventricle dysfunction is the most common cause of heart failure, which leads to high mortality and morbidity. The mechanical behavior of the ventricle is critical to its physiological function. It is known that the ventricle is anisotropic and viscoelastic. However, the understanding of ventricular viscoelasticity is much less than that of its elasticity. Moreover, the left and right ventricles (LV&RV) are different in embryologic origin, anatomy, and function, but whether they distinguish in viscoelastic properties is unclear. We hypothesized that passive viscoelasticity is different between healthy LVs and RVs. Ex vivo cyclic biaxial tensile mechanical tests (1, 0.1, 0.01 Hz) and stress relaxation (strain of 3, 6, 9, 12, 15%) were performed for ventricles from healthy adult sheep. Outflow track direction was defined as the longitudinal direction. Hysteresis stress–strain loops and stress relaxation curves were obtained to quantify the viscoelastic properties. We found that the RV had more pronounced frequency-dependent viscoelastic changes than the LV. Under the physiological frequency (1 Hz), the LV was more anisotropic in the elasticity and stiffer than the RV in both directions, whereas the RV was more anisotropic in the viscosity and more viscous than the LV in the longitudinal direction. The LV was quasi-linear viscoelastic in the longitudinal but not circumferential direction, and the RV was nonlinear viscoelastic in both directions. This study is the first to investigate passive viscoelastic differences in healthy LVs and RVs, and the findings will deepen the understanding of biomechanical mechanisms of ventricular function.


  • 1514 - Diagnostic Monitoring and Prediction of Fracture Healing via Non-Invasive Measurement of Mechanical Stability in Bending

    by Kevin Labus

    INTRODUCTION: Abnormally healing fractures such as non-union often require therapeutic intervention or surgical revision. The treatment of fractu |