Alessia Chini

Alessia Chini

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alessia Chini has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Endoscopic Treatment of Staple-Line Leaks After Sleeve Gastrectomy in Patients with Obesity: Which One is the Best Option, if Any? A Systematic Review with Meta-Analysis and Meta-regression

    by Giuseppe Galloro, Mariano Cesare Giglio, Alessia Chini, Rosa Maione, Matteo Pollastro, Rosa Vitale, Antonio Pisani, Mario Musella

    Laparoscopic sleeve gastrectomy (LSG) is the most common bariatric surgery, with staple-line leak (SLL) as its most severe complication. Various endoscopic treatments exist, but no universal algorithm is established. The aim of this paper is to estimate the success rates of different endoscopic techniques for SLL management. A search of Medline, Embase, and SCOPUS identified studies on endoscopic treatments. Pooled success rates were calculated using random-effects modeling. Seventy-nine studies (2205 patients) showed an overall success rate of 84.1%. Double-pigtail drainage (90.07%), endoscopic vacuum therapy (90.2%), and septotomy (88.25%) were most effective. Meta-regression indicated significantly higher success with double-pigtail drainage ( p = 0.035). Endoscopic treatments, especially double-pigtail drainage and vacuum therapy, are highly effective for SLL. Further research is needed to compare techniques and evaluate additional clinical factors.


  • Open Access

    Esophagitis and Barrett’s Esophagus

    by Giuseppe Galloro, Rosa Maione, Alessia Chini

  • Open Access

    Could atmospheric temperature impact on adequate colon cleansing for colonoscopy? An observational, single-institution study

    by Francesco Maione, Michele Manigrasso, Marco Milone, Nicola Gennarelli, Rosa Maione, Grazia Cantore, Alessia Chini, Giovanni Domenico De Palma

    Purpose: Several risk factors affecting the adequacy of colon cleansing have been proposed during the last decades. However, less is known about the impact that atmospheric aspects could have on adequacy of the bowel cleansing. The study aimed to investigate if the atmospheric temperature could impact on the bowel cleansing during colonoscopy. Methods: A prospective maintained database of the colonoscopies performed since 1st August 2017 to 31st March 2020 was retrospective reviewed. The primary outcome of the study was to identify if the atmospheric temperature was associated with inadequate colon cleansing during colonoscopy. Secondary outcome was to identify the other factors associated with an inadequate colon cleansing. Results: One thousand two hundred twenty patients were enrolled. High atmospheric temperature (> 25 °C) significantly influenced the colon cleansing (p < 0.0001). Adequate colon cleansing was negatively influenced by gender (female patients were associated with higher colon cleansing rate, p = 0.013), diabetes (p < 0.0001), previous pelvic surgery (p = 0.001), use of Beta-Blocker (p = 0.001), anti-platelet (p = 0.017), angiotensin converting enzyme inhibitors (p = 0.001), the adoption of 4 L Poly Ethylene Glycol solution (p = 0.009), single-dose regimen (p < 0.0001) low patients’ compliance (p < 0.0001), higher age and body mass index (p < 0.0001 and p = 0.025), lower education levels (p < 0.0001). On the contrary, admission to the ward to perform bowel preparation positively impacted on colon cleansing (p = 0.002). Conclusion: Atmospheric temperature could play an important role in the colon cleansing during colonoscopy, being high temperature (> 25 °C) associated with lower rate of adequate bowel cleansing. However, being this relationship never studied before, these results must be confirmed by other studies.


  • Open Access

    Robotic Surgery and Functional Esophageal Disorders: A Systematic Review and Meta-Analysis

    by Sara Vertaldi, Anna D’amore, Michele Manigrasso, Pietro Anoldo, Alessia Chini, Francesco Maione, Marcella Pesce, Giovanni Sarnelli, Giovanni Domenico De Palma, Marco Milone

    The functional disease of the esophago-gastric junction (EGJ) is one of the most common health problems. It often happens that patients suffering from GERD need surgical management. The laparoscopic fundoplication has been considered the gold standard surgical treatment for functional diseases of the EGJ. The aim of our meta-analysis is to investigate functional outcomes after robotic fundoplication compared with conventional laparoscopic fundoplication. A prospective search of online databases was performed by two independent reviewers using the search string “robotic and laparoscopic fundoplication”, including all the articles from 1996 to December 2021. The risk of bias within each study was assessed with the Cochrane ROBINS-I and RoB 2.0 tools. Statistical analysis was performed using Review Manager version 5.4. In addition, sixteen studies were included in the final analysis, involving only four RCTs. The primary endpoints were functional outcomes after laparoscopic (LF) and robotic fundoplication (RF). No significant differences between the two groups were found in 30-day readmission rates (p = 0.73), persistence of symptomatology at follow-up (p = 0.60), recurrence (p = 0.36), and reoperation (p = 0.81). The laparoscopic fundoplication represents the gold standard treatment for the functional disease of the EGJ. According to our results, the robotic approach seems to be safe and feasible as well. Further randomized controlled studies are required to better evaluate the advantages of robotic fundoplication.


  • Open Access

    Endoscopic clipping in non-variceal upper gastrointestinal bleeding treatment

    by Giuseppe Galloro, Angelo Zullo, Gaetano Luglio, Alessia Chini, Donato Alessandro Telesca, Rosa Maione, Matteo Pollastro, Giovanni Domenico De Palma, Raffaele Manta

    Since the earliest reports, advanced clipping systems have been developed, and it is possible to choose among many models with different structural and technical features. The main drawback of through-the-scope clips is their small size, which allows the compression of limited amounts of tissue needed for large-size vessel treatment. Therefore, the over-the-scope clip system was realized, allowing a larger and stronger mechanical compression of large tissue areas, with excellent results in achieving a definitive hemostasis in difficult cases. Many studies have analyzed the indications and efficacy of two-pronged endoclips and have shown good results for initial and permanent hemostasis. The aim of this review was to provide updated information on indications, positioning techniques, and results of clip application for endoscopic treatment of upper gastrointestinal non-variceal bleeding lesions.


  • Open Access

    Endoscopic Diagnosis and Management of Barrett’s Esophagus with Low-Grade Dysplasia

    by Francesco Maione, Alessia Chini, Rosa Maione, Michele Manigrasso, Alessandra Marello, Gianluca Cassese, Nicola Gennarelli, Marco Milone, Giovanni Domenico De Palma

    Barrett’s Esophagus is a common condition associated with chronic gastroesophageal reflux disease. It is well known that it has an association with a higher incidence of esophageal adenocarcinoma, but this neoplastic transformation is first preceded by the onset of low and high-grade dysplasia. The evaluation of low grade dysplastic esophageal mucosa is still controversial; although endoscopic surveillance is preferred, several minimally invasive endoscopic therapeutic approaches are available. Endoscopic mucosal resection and radiofrequency ablation are the most used endoscopic treatments for the eradication of low-grade dysplasia, respectively, for nodular and flat dysplasia. Novel endoscopic treatments are cryotherapy ablation and argon plasma coagulation, that have good rates of eradication with less complications and post-procedural pain.


  • Open Access

    The Role of Indocyanine Near-Infrared Fluorescence in Colorectal Surgery

    by Francesco Maione, Michele Manigrasso, Alessia Chini, Sara Vertaldi, Pietro Anoldo, Anna D’aMore, Alessandra Marello, Carmen Sorrentino, Grazia Cantore, Rosa Maione, et al.

    Purposes: The aim of this study was to evaluate the importance of Indocyanine Green in control of anastomosis perfusion and on anastomotic leakage rates during laparoscopic and robotic colorectal procedures. Methods: A retrospective review of patients who underwent elective minimally invasive surgery for colorectal cancer from 1 January 2018 to 31 December 2020 was performed. All patients underwent Near-Infrared Fluorescence-Indocyanine Green system in two moments: before performing the anastomosis and after completing the anastomotic procedure. Primary outcomes were the rate of intraoperative change in the surgical resection due to an inadequate vascularization and the rate of postoperative anastomotic leakage. Secondary outcomes were the postoperative complications, both medical and surgical (intra-abdominal bleeding, anastomotic leakage). Results: Our analysis included 93 patients. Visible fluorescence was detected in 100% of the cases. In 7 patients (7.5%), the planned site of resection was changed due to inadequate perfusion. The mean extension of the surgical resection in these 7 patients was 2.2 ± 0.62. Anastomotic leakage occurred in 2 patients (2.1%). Other complications included 8 postoperative bleedings (8.6%) and 1 pulmonary thromboembolism. Conclusions: The intraoperative use of Near-Infrared Fluorescence-Indocyanine Green in colorectal surgery is safe, feasible, and associated with a substantial reduction in postoperative anastomotic leakage rate.


  • Open Access

    Can Computed Tomography Colonography Replace Optical Colonoscopy in Detecting Colorectal Lesions?: State of the Art

    by Alessia Chini, Michele Manigrasso, Grazia Cantore, Rosa Maione, Marco Milone, Francesco Maione, Giovanni Domenico De Palma

    Colorectal cancer is an important cause of morbidity and mortality worldwide. Optical colonoscopy (OC) is widely accepted as the reference standard for the screening of colorectal polyps and cancers, and computed tomography colonography (CTC) is a valid alternative to OC. The purpose of this review was to assess the diagnostic accuracy of OC and CTC for colorectal lesions. A literature search was performed in PubMed, Embase, and Cochrane Library, and 18 articles were included. CTC has emerged in recent years as a potential screening examination with high accuracy for the detection of colorectal lesions. However, the clinical application of CTC as a screening technique is limited because it is highly dependent on the size of the lesions and has poor performance in detecting individual lesions <5 mm or flat lesions, which, although rarely, can have a malignant potential.


  • Open Access

    Endorectal Ultrasonography and Pelvic Magnetic Resonance Imaging Show Similar Diagnostic Accuracy in Local Staging of Rectal Cancer: An Update Systematic Review and Meta-Analysis

    by Gaetano Luglio, Gianluca Pagano, Francesca Paola Tropeano, Eduardo Spina, Rosa Maione, Alessia Chini, Francesco Maione, Giuseppe Galloro, Mariano Cesare Giglio, Giovanni Domenico De Palma

    Background: Endorectal Ultrasonography (EUS-ERUS) and pelvic magnetic resonance imaging (MRI) are world-wide performed for the local staging of rectal cancer (RC), but no clear consensus on their indications is present, there being literature in support of both. The aim of this meta-analysis is to give an update regarding the diagnostic test accuracy of ERUS and pelvic MRI about the local staging of RC. Materials and methods: A systematic literature search from November 2020 to October 2021 was performed to select studies in which head-to-head comparison between ERUS and MRI was reported for the local staging of rectal cancer. Quality and risk of bias were assessed with the QUADAS-2 tool. Our primary outcome was the T staging accuracy of ERUS and MRI for which pooled accuracy indices were calculated using a bivariable random-effects model. In addition, a hierarchical summary receiver operating characteristic curve (hSROC) was created to characterize the accuracy of ERUS and MRI for the staging of T and N parameters. The area under the hSROC curve (AUChSROC) was determined as a measure of diagnostic accuracy. Results: Seven studies and 331 patients were included in our analysis. ERUS and MRI showed a similar accuracy for the T staging, with AUChSROC curves of 0.91 (95% C.I., 0.89 to 0.93) and 0.87 (95% C.I., 0.84 to 0.89), respectively (p = 0.409). For T staging, ERUS showed a pooled sensitivity of 0.82 (95% C.I. 0.72 to 0.89) and pooled specificity of 0.91 (95% C.I. 0.77–0.96), while MRI had pooled sensitivity and specificity of 0.69 (95% C.I. 0.55–0.81) and 0.88 (95% C.I. 0.79–0.93), respectively. ERUS and MRI showed a similar accuracy in the N staging too, with AUChSROC curves of 0.92 (95% C.I., 0.89 to 0.94) and 0.93 (95% C.I., 0.90 to 0.95), respectively (p = 0.389). Conclusions: In conclusion, ERUS and MRI are comparable imaging techniques for the local staging of rectal cancer.


  • Open Access

    Endoscopic resection of a large polypoid gastric heterotopia of duodenum: a case report

    by Francesco Maione, Alessia Chini, Nicola Gennarelli, Marco Milone, Michele Manigrasso, Elia Guadagno, Giovanni Aprea, Giovanni Domenico De Palma

    This report shows a rare case of gastric heterotopia in the duodenum presented as a large polypoid lesion, differently from data reported in literature, which enters into differential diagnosis with other duodenal lesions that are not always benign.