Hassaan Abdel Khalik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Hassaan Abdel Khalik has a total of 123 co-authors. Here are the top co-authors by number of shared publications:
- Moin Khan
Department of Orthopaedic Surgery, McMaster University, Hamilton, Ontario, Canada
6 shared publications Darius L. Lameire
Division of Orthopaedics, Department of Surgery, Temerty Faculty of Medicine, University of Toronto, Toronto, Canada
5 shared publicationsJames Abesteh
Division of Orthopaedic Surgery, McMaster University, Hamilton, ON, Canada
5 shared publicationsThomas J. Wood
Division of Orthopaedic Surgery, McMaster University, Hamilton, Ontario, Canada
5 shared publicationsBrian P. Chalmers
Department of Orthopedic Surgery, Hospital for Special Surgery, New York, NY, USA
4 shared publicationsOlufemi R. Ayeni
Division of Orthopaedic Surgery, McMaster University, Hamilton, ON, Canada
4 shared publications
Latest Publications
- 25 August 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 484 (10) , 1914-1921
Cochrane in CORR®: Cryotherapy Following Total Knee Replacement
Was not provided for this article.
- 25 August 2026
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 484 (10) , 1914-1921
Cochrane in CORR®: Cryotherapy Following Total Knee Replacement
Was not provided for this article.
- Open Access
- 30 July 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (3)
Mechanically aligned total knee arthroplasty demonstrates acceptable outcomes in obese patients, with insufficient evidence for alternative alignment strategies: A systematic review
Purpose: Obesity (body mass index [BMI] ≥ 30 kg/m 2 ) is increasingly prevalent among total knee arthroplasty (TKA) patients and is associated with unique challenges. The role of various TKA alignment strategies in obese patients remains unclear. To evaluate the clinical, functional, radiographic, survivorship and complication outcomes of primary TKA in obese patients across alignment philosophies. Methods: Eligible studies (1) included patients who underwent primary TKA with defined alignment, (2) reported BMI ≥ 30 kg/m 2 or provided stratified data for obese versus non‐obese groups, (3) reported at least one of: patient‐reported outcome measures (PROMs), range of motion (ROM), radiographic outcomes, or complications and (4) were randomized controlled trials (RCTs), cohort studies or case–control studies. Results: Thirty studies were included. 8468 obese patients (14,662 knees) underwent mechanically aligned TKA, with mean follow‐up of 91.1 ± 45.3 months (range, 0.5–110.5 months). Mechanically aligned TKA in obese patients was associated with post‐operative improvements in PROMs, including Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis Index and Oxford Knee Score. Short‐term cumulative aseptic revision incidence was low, ranging from 0.5% to 1.3%, while revision‐free survivorship commonly exceeded 95% at short‐term and >90% at long‐term follow‐up. Radiographic outcomes demonstrated reliable restoration of near‐neutral limb alignment across BMI strata. One study evaluated a kinematically‐designed bicruciate‐stabilized implant with an unspecified alignment strategy in obese patients, and another study evaluated functional alignment in obese patients, limiting comparisons. Conclusion: Evidence evaluating the influence of alignment on outcomes in obese patients undergoing TKA remains insufficient to determine whether alignment philosophy meaningfully affects clinical or radiographic outcomes. Although mechanically aligned TKA demonstrated generally acceptable post‐operative outcomes in obese cohorts, the available literature was overwhelmingly dominated by mechanically aligned studies, with only limited evaluation of alternative approaches. Level of Evidence: Level IV.
- 30 July 2026
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 13 (3)
Open AccessMechanically aligned total knee arthroplasty demonstrates acceptable outcomes in obese patients, with insufficient evidence for alternative alignment strategies: A systematic review
Purpose: Obesity (body mass index [BMI] ≥ 30 kg/m 2 ) is increasingly prevalent among total knee arthroplasty (TKA) patients and is associated with unique challenges. The role of various TKA alignment strategies in obese patients remains unclear. To evaluate the clinical, functional, radiographic, survivorship and complication outcomes of primary TKA in obese patients across alignment philosophies. Methods: Eligible studies (1) included patients who underwent primary TKA with defined alignment, (2) reported BMI ≥ 30 kg/m 2 or provided stratified data for obese versus non‐obese groups, (3) reported at least one of: patient‐reported outcome measures (PROMs), range of motion (ROM), radiographic outcomes, or complications and (4) were randomized controlled trials (RCTs), cohort studies or case–control studies. Results: Thirty studies were included. 8468 obese patients (14,662 knees) underwent mechanically aligned TKA, with mean follow‐up of 91.1 ± 45.3 months (range, 0.5–110.5 months). Mechanically aligned TKA in obese patients was associated with post‐operative improvements in PROMs, including Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis Index and Oxford Knee Score. Short‐term cumulative aseptic revision incidence was low, ranging from 0.5% to 1.3%, while revision‐free survivorship commonly exceeded 95% at short‐term and >90% at long‐term follow‐up. Radiographic outcomes demonstrated reliable restoration of near‐neutral limb alignment across BMI strata. One study evaluated a kinematically‐designed bicruciate‐stabilized implant with an unspecified alignment strategy in obese patients, and another study evaluated functional alignment in obese patients, limiting comparisons. Conclusion: Evidence evaluating the influence of alignment on outcomes in obese patients undergoing TKA remains insufficient to determine whether alignment philosophy meaningfully affects clinical or radiographic outcomes. Although mechanically aligned TKA demonstrated generally acceptable post‐operative outcomes in obese cohorts, the available literature was overwhelmingly dominated by mechanically aligned studies, with only limited evaluation of alternative approaches. Level of Evidence: Level IV.
- 2 May 2026
- Published by Springer Nature
- p. 1131-1157
Outcomes Following Arthroscopic Surgery of the Hip
- 2 May 2026
- Published by Springer Nature
- p. 1131-1157
Outcomes Following Arthroscopic Surgery of the Hip
- Open Access
- 9 April 2026
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 22 (4) , 402-411
Evaluating Spin Bias in the Abstracts of Systematic Reviews and Meta-Analyses on Robotic-Assisted Total Hip Arthroplasty: A Systematic Review
Background: Interest in robotic-assisted total hip arthroplasty (RA-THA) continues to grow, despite inconsistent evidence on its effectiveness. Purpose: We sought to assess for the presence of spin bias in abstracts of systematic reviews and meta-analyses (SRMAs) comparing RA-THA to conventional total hip arthroplasty (C-THA). Methods: We conducted a systematic review of studies identified in a comprehensive search of MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews from each database’s inception to June 23, 2025. Search terms included “robotic,” “hip,” “arthroplasty,” “systematic review,” and “meta-analysis.” Inclusion criteria were (1) SRMAs evaluating outcomes of RA-THA, (2) studies comparing RA-THA to conventional techniques, and (3) publications in English. Studies were excluded if they (1) assessed RA-THA with other robotic-assisted joint arthroplasty procedure, or (2) assessed RA-THA surgery alongside other technologies. Abstracts were assessed for the 15 most severe forms of spin as defined by Yavchitz et al. Methodological quality was assessed using the AMSTAR 2 (A Measurement Tool to Assess Systematic Reviews-2) tool. Results: Twelve SRMAs were eligible for inclusion. Eleven SRMAs (91.7%) contained at least 1 of the 15 most severe forms of spin. Type 3 spin ( selective reporting of efficacy outcomes favoring the intervention ) was the most common (58%), followed by type 5 ( conclusion claims the beneficial effect of the experimental intervention despite high risk of bias in primary studies ; 50%), and type 11 ( conclusion focuses selectively on statistically significant efficacy outcome; 33.3%). No differences in study characteristics were found between SRMAs with and without the aforementioned types of spin. All SRMAs were rated as “critically low” in methodological quality, with most not reporting funding source of included studies (91.7%). Conclusion: This systematic review found there is a high prevalence of spin bias in abstracts of SRMAs evaluating RA-THA. The most common type of spin involved selective reporting of outcomes favoring RA-THA (type 3). Future SRMAs can minimize spin by presenting balanced reporting of efficacy, or lack thereof, in their abstracts and strengthen methodological rigor by consistently reporting study funding sources. Level of Evidence: Level IV, Systematic review of level-I to level-IV studies.
- 9 April 2026
- Published by SAGE Publications in HSS Journal®: The Musculoskeletal Journal of Hospital for Special Surgery
- Vol. 22 (4) , 402-411
Open AccessEvaluating Spin Bias in the Abstracts of Systematic Reviews and Meta-Analyses on Robotic-Assisted Total Hip Arthroplasty: A Systematic Review
Background: Interest in robotic-assisted total hip arthroplasty (RA-THA) continues to grow, despite inconsistent evidence on its effectiveness. Purpose: We sought to assess for the presence of spin bias in abstracts of systematic reviews and meta-analyses (SRMAs) comparing RA-THA to conventional total hip arthroplasty (C-THA). Methods: We conducted a systematic review of studies identified in a comprehensive search of MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews from each database’s inception to June 23, 2025. Search terms included “robotic,” “hip,” “arthroplasty,” “systematic review,” and “meta-analysis.” Inclusion criteria were (1) SRMAs evaluating outcomes of RA-THA, (2) studies comparing RA-THA to conventional techniques, and (3) publications in English. Studies were excluded if they (1) assessed RA-THA with other robotic-assisted joint arthroplasty procedure, or (2) assessed RA-THA surgery alongside other technologies. Abstracts were assessed for the 15 most severe forms of spin as defined by Yavchitz et al. Methodological quality was assessed using the AMSTAR 2 (A Measurement Tool to Assess Systematic Reviews-2) tool. Results: Twelve SRMAs were eligible for inclusion. Eleven SRMAs (91.7%) contained at least 1 of the 15 most severe forms of spin. Type 3 spin ( selective reporting of efficacy outcomes favoring the intervention ) was the most common (58%), followed by type 5 ( conclusion claims the beneficial effect of the experimental intervention despite high risk of bias in primary studies ; 50%), and type 11 ( conclusion focuses selectively on statistically significant efficacy outcome; 33.3%). No differences in study characteristics were found between SRMAs with and without the aforementioned types of spin. All SRMAs were rated as “critically low” in methodological quality, with most not reporting funding source of included studies (91.7%). Conclusion: This systematic review found there is a high prevalence of spin bias in abstracts of SRMAs evaluating RA-THA. The most common type of spin involved selective reporting of outcomes favoring RA-THA (type 3). Future SRMAs can minimize spin by presenting balanced reporting of efficacy, or lack thereof, in their abstracts and strengthen methodological rigor by consistently reporting study funding sources. Level of Evidence: Level IV, Systematic review of level-I to level-IV studies.
- 4 February 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 74, 404-411
Robotic-assisted total knee arthroplasty in patients with moderate-to-severe coronal deformities: A systematic review
- 4 February 2026
- Published by Elsevier in Journal of Orthopaedics
- Vol. 74, 404-411
Robotic-assisted total knee arthroplasty in patients with moderate-to-severe coronal deformities: A systematic review
- Open Access
- 18 January 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (6) , 1525-1536
Structural Augmentation in Rotator Cuff Repair Decreases the Risk of Retear: A Systematic Review and Meta-analysis
Background: Rotator cuff tears are a common orthopaedic injury often resulting in shoulder pain and functional impairment. Despite the prevalence of rotator cuff tears, the incidence of retear after rotator cuff repair (RCR) remains high. There is growing interest in the use of structural augmentation in RCR to decrease retear rates and improve patient outcomes. Purpose: The purpose of this systematic review and meta-analysis was to compare the clinical and imaging outcomes of structural augmentation versus standard RCR in patients with full-thickness rotator cuff tears. The effectiveness of different augment subtypes was also assessed. Study Design: Meta-analysis; Level of evidence, 3. Methods: A comprehensive literature search was conducted in CENTRAL, Embase, and Medline from inception to November 13, 2024. Eligible studies included comparative trials evaluating structural augmentation in RCR for repairable full-thickness tears. Risk of bias was assessed using the Cochrane risk-of-bias tool for randomized controlled trials and the MINORS (Methodological Index for Non-randomized Studies) score for observational studies. Meta-analyses were performed via a random effects model, with subgroup analyses performed by study design and augment type. Results: Twenty-four studies (12 randomized controlled trials and 12 cohort studies) were included in this review, all of which evaluated biologic augments (xenograft, allograft, autograft). Structural augmentation significantly reduced the risk of retear by 35% as compared with standard RCR (risk ratio, 0.65; 95% CI, 0.48-0.89; P = .01). Retears were confirmed radiographically by magnetic resonance imaging or ultrasound. Subgroup analysis revealed the greatest reduction in retear rates with allograft augmentation (risk ratio, 0.34; 95% CI, 0.21-0.56). No significant differences were observed in patient-reported outcomes, including pain scores, American Shoulder and Elbow Surgeons scores, or Constant scores. Conclusion: Structural augmentation in RCR significantly reduces retear rates, particularly with allografts, but does not improve short-term patient-reported outcomes. Further research is needed to identify which patient and tear characteristics may influence the effectiveness of augmentation.
- 18 January 2026
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 54 (6) , 1525-1536
Open AccessStructural Augmentation in Rotator Cuff Repair Decreases the Risk of Retear: A Systematic Review and Meta-analysis
Background: Rotator cuff tears are a common orthopaedic injury often resulting in shoulder pain and functional impairment. Despite the prevalence of rotator cuff tears, the incidence of retear after rotator cuff repair (RCR) remains high. There is growing interest in the use of structural augmentation in RCR to decrease retear rates and improve patient outcomes. Purpose: The purpose of this systematic review and meta-analysis was to compare the clinical and imaging outcomes of structural augmentation versus standard RCR in patients with full-thickness rotator cuff tears. The effectiveness of different augment subtypes was also assessed. Study Design: Meta-analysis; Level of evidence, 3. Methods: A comprehensive literature search was conducted in CENTRAL, Embase, and Medline from inception to November 13, 2024. Eligible studies included comparative trials evaluating structural augmentation in RCR for repairable full-thickness tears. Risk of bias was assessed using the Cochrane risk-of-bias tool for randomized controlled trials and the MINORS (Methodological Index for Non-randomized Studies) score for observational studies. Meta-analyses were performed via a random effects model, with subgroup analyses performed by study design and augment type. Results: Twenty-four studies (12 randomized controlled trials and 12 cohort studies) were included in this review, all of which evaluated biologic augments (xenograft, allograft, autograft). Structural augmentation significantly reduced the risk of retear by 35% as compared with standard RCR (risk ratio, 0.65; 95% CI, 0.48-0.89; P = .01). Retears were confirmed radiographically by magnetic resonance imaging or ultrasound. Subgroup analysis revealed the greatest reduction in retear rates with allograft augmentation (risk ratio, 0.34; 95% CI, 0.21-0.56). No significant differences were observed in patient-reported outcomes, including pain scores, American Shoulder and Elbow Surgeons scores, or Constant scores. Conclusion: Structural augmentation in RCR significantly reduces retear rates, particularly with allografts, but does not improve short-term patient-reported outcomes. Further research is needed to identify which patient and tear characteristics may influence the effectiveness of augmentation.
- 12 January 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 167
Robotic arm-assisted total hip arthroplasty in patients with hip dysplasia: a systematic review
This review summarizes radiographic, clinical and patient reported outcomes following robotic-arm assisted total hip arthroplasty (RAA-THA) in patients with developmental dysplasia of the hip (DDH), with comparisons to conventional (C-THA) and navigation (N-THA) techniques. MEDLINE, EMBASE and CENTRAL databases were searched for studies on DDH patients undergoing RAA-THA. Outcomes assessed included radiographic accuracy, patient-reported outcome-measures (PROMs), intraoperative outcomes, and complications. Eleven studies were included, analyzing 1150 hips (641 RAA-THA, 383 C-THA, 126 N-THA) with a median patient age of 60.5 years, and median BMI of 24.6. DDH severity was distributed as 59.6% Crowe I, 25.3% Crowe II/III hips, and 15.1% Crowe IV hips. Comparative studies among Crowe I–III hips showed significantly lower errors in cup inclination and anteversion with RAA-THA compared to both C-THA and N-THA. RAA-THA also achieved greater accuracy in restoring the center of rotation for Crowe I–III, but no difference was observed in Crowe IV hips. No significant differences were found in short-term PROMs, and intraoperative outcomes and complication rates were comparable between groups. RAA-THA may improve cup placement accuracy in Crowe I-III hips compared to C-THA and N-THA. However, the accuracy of Crowe IV hips remains unclear, with limited evidence available. Furthermore, radiographic benefits did not translate into significant differences in short-term PROMs, intraoperative outcomes, or complication rates. Future studies should include larger cohorts of patients with severe dysplasia and provide longer follow-up to better evaluate the efficacy and implant survivorship of RAA-THA in these complex cases. Level of Evidence: IV.
- 12 January 2026
- Published by Springer Nature in Journal of Robotic Surgery
- Vol. 20 (1) , 167
Robotic arm-assisted total hip arthroplasty in patients with hip dysplasia: a systematic review
This review summarizes radiographic, clinical and patient reported outcomes following robotic-arm assisted total hip arthroplasty (RAA-THA) in patients with developmental dysplasia of the hip (DDH), with comparisons to conventional (C-THA) and navigation (N-THA) techniques. MEDLINE, EMBASE and CENTRAL databases were searched for studies on DDH patients undergoing RAA-THA. Outcomes assessed included radiographic accuracy, patient-reported outcome-measures (PROMs), intraoperative outcomes, and complications. Eleven studies were included, analyzing 1150 hips (641 RAA-THA, 383 C-THA, 126 N-THA) with a median patient age of 60.5 years, and median BMI of 24.6. DDH severity was distributed as 59.6% Crowe I, 25.3% Crowe II/III hips, and 15.1% Crowe IV hips. Comparative studies among Crowe I–III hips showed significantly lower errors in cup inclination and anteversion with RAA-THA compared to both C-THA and N-THA. RAA-THA also achieved greater accuracy in restoring the center of rotation for Crowe I–III, but no difference was observed in Crowe IV hips. No significant differences were found in short-term PROMs, and intraoperative outcomes and complication rates were comparable between groups. RAA-THA may improve cup placement accuracy in Crowe I-III hips compared to C-THA and N-THA. However, the accuracy of Crowe IV hips remains unclear, with limited evidence available. Furthermore, radiographic benefits did not translate into significant differences in short-term PROMs, intraoperative outcomes, or complication rates. Future studies should include larger cohorts of patients with severe dysplasia and provide longer follow-up to better evaluate the efficacy and implant survivorship of RAA-THA in these complex cases. Level of Evidence: IV.