  • Experimental Study on the Cumulative Deformation Effects of Power Transformer Windings Using Fiber Bragg Grating Sensors

    by Hang Guo, Xu Li, Jun Liu, She Chen, Dengfeng Zhu, Feng Wang, Litong Li, Zhongxiang Li

    Power transformers undergo cumulative winding deformation and potential failure when subjected to multiple short-circuit impacts. However, existing methods for detecting winding deformation are susceptible to interference from test setup and complex on-site environments, and they have low identification accuracy, making it difficult to capture the cumulative process of micro-deformation in windings under multiple impacts and accurately locate the deformation positions. To further investigate the cumulative deformation process of transformer windings under multiple short-circuit impacts and locate the deformation positions, this study proposes a method for high-precision measurement of winding deformation using a quasi-distributed fiber Bragg grating (FBG) sensor based on winding structure arrangement. Its grating zone can be as short as millimeter-level, achieving strain measurement accuracy of 4.5με, and can withstand up to 18 consecutive short-circuit current impacts. A short-circuit impact test model was designed, and experiments with different current ratios were conducted. Strain waveforms at various points were successfully monitored, and strain characteristics were extracted to analyze the de-formation accumulation patterns and locate the deformation positions. Finally, the transformer windings are disassembled and analyzed to verify the monitoring results. The results indicate that as the number of short circuits increases, the deformation accumulation process of the winding is not slowed down by changes in the current ratio. The radial deformation accumulation degree is positively correlated with the strain peak. Additionally, the deformation accumulation degree of windings that only undergo radial deformation is also positively correlated with the strain before the impact. The strain monitoring results are highly consistent with the actual deformation locations, verifying the effectiveness, sensitivity, and accuracy of FBG monitoring for winding deformation. This can effectively assist in diagnosing winding deformation conditions and provide a basis for assessing the status of windings in operational aging transformers.


  • Theoretical Evaluation of Transformer Short-Circuit Withstand Capability and Identification Method of Winding Cumulative Deformation

    by Jun Liu, She Chen, Feng Wang, Dengfeng Zhu, Kui Xu, Peilong Chen, Zhongxiang Li

    As power system capacity increases, power transformers frequently endure multiple short-circuit impulses of varying intensities. Existing evaluation methods cannot accurately predict their cumulative effects, which hinders effective operation and maintenance. In this study, a double-leg, three-winding mock-up transformer has been built up. Theoretical short-circuit withstand capability is evaluated using WELDINST software and methods recommended by Chinese and Japanese transformers technical committee. Short-circuit impulse experiments with varying current ratios are performed to investigate cumulative effects under radial and axial instability. The results show that the prediction accuracy varies across different methods and instability modes. The Chinese transformer technical committee recommended method performs better under axial instability, while the WELDINST method excels excellent under radial instability. The experimental results showing average deviations of 19.75% and 8.92%, respectively. The experiment show that significant cumulative effects appear when the current ratio exceeds 70%. Furthermore, an exponential function was established between impedance cumulative effects and current ratios. Finally, the steady-state vibration main fundamental ratio and vibration entropy, enable real-time identification of the winding state, showing a relationship with changes in winding impedance. Larger impedance variations are associated with lower steady-state vibration main fundamental ratio and higher vibration entropies.


  • Open Access

    Influence of Short‐Circuit Current Nonperiodic Component Increasing on Radial Dynamic Stability of Power Transformer Winding Under Reclosing

    by Yuefeng Hao, Jun Liu, Xiaoli Zhang, Weiwei Zhang

    As one of the key main equipment of the power system, the transformer directly affects the safe and reliable operation of the system. In the process of transformer reclosing, the internal electromagnetic environment is obviously different from that of the initial short circuit. The nonperiodic component of the short‐circuit current exceeds that of the initial short circuit, increasing the electromagnetic force on the winding and severely threatening its dynamic stability. In order to study the influence of reclosing short‐circuit impact on the radial dynamic stability of transformer winding, this paper takes SFSZ9‐50000/110 transformer as an example. Firstly, the numerical model of short‐circuit current of infinite power system is constructed by Matlab/Simulink, and the short‐circuit current of initial short‐circuit and reclosing process is calculated. The increase value of the reclosing short‐circuit current compared with the initial short‐circuit current is calculated, and the accuracy of the short‐circuit current numerical calculation model is verified by comparison with the theoretical value. The results show that for the power transformer studied in this paper, the three‐phase short‐circuit current of the transformer under the reclosing short‐circuit condition increases by about 6% compared with the initial short‐circuit current. Then, based on the short‐circuit current, the finite element method is used to analyse the leakage magnetic field of the transformer winding by using ANSYS Maxwell and the variation law of the electromagnetic force under the reclosing short‐circuit impact. Finally, various kinds of radial stress of transformer winding under initial short‐circuit and reclosing short‐circuit conditions are compared and checked. The results show that under the reclosing condition, the average circumferential stress and inner winding radial bending stress of the transformer increase by about 12%, which leads to the decrease of the dynamic stability margin of the transformer. The research results have reference significance for optimising the dynamic stability verification method of transformer winding under reclosing short‐circuit impact.


  • Open Access

    Experimental Investigation on Cumulative Effects of Transformer Winding Deformation Under Short‐Circuit Impulses

    by Jun Liu, She Chen, Feng Wang, Dengfeng Zhu, Xu Li, Yao Zhong, Zhongxiang Li

    Power transformer windings are susceptible to deformation after multiple short‐circuit impulses, threatening power grid stability. Currently, there is a lack of experimental data on various characteristic parameters of failures after multiple short‐circuit impulses. To investigate winding deformation and its gradual deterioration, a mock‐up transformer was constructed to study the cumulative effects. Short‐circuit tests were conducted under different current ratios, and the cumulative effect was quantified based on short‐circuit impedance and axial force variations. A correlation was established between different current ratios, impulse number and cumulative winding deformation. The cumulative effects of winding deformation are categorised into four levels: none, minor, significant and severe. Thresholds indicating severe deformation and degraded short‐circuit withstand ability are defined by an absolute impedance change rate exceeding 1.1% and a relative rate exceeding 0.3%. Additionally, an axial force change rate of ± 20% serves as an early warning indicator, providing greater sensitivity to detecting impulse effects on winding stability compared to impedance change rate. Monitoring impedance and axial force changes provides a reliable approach to assessing transformers affected by the cumulative effects of short‐circuit and identifying the risk of winding deformation.


  • Open Access

    Analysis on Rail Potential Distribution Characteristics Considering OVPD in Metro System

    by Ning Xiao, Jun Liu, Jianzhou Wu, Huarong Zeng, Zhukui Tan, Peng Zeng, Wei Niu, Peilong Chen, Huan Huang, Kui Xu, et al.

    By the field investigation of the metro system, it is found that there is relatively serious corrosion in the terminal of the metro line, and overvoltage protection device (OVPD) often operates when the metro system is in the valley level. In order to analyze the causes of these conditions and alleviate the related problems caused by high rail potential. In this paper, establish a simulation model of metro system by CDEGS software, and consider the influence of the track-to-track cross bond on rail potential. It is analyzed that the causes of high rail potential in the terminal of the metro line and high rail potential operating small number of trains in the metro line. And it is analyzed that the influence on the rail potential of metro line, the influence on OVPD outside the power supply section, the influence on the station grounding gird where the OVPD is, caused by OVPD operation. The results show that the rail potential can be reduced to some extent by setting the track-to-track cross bond. No traction power substation (TPS) in the terminal of the metro line increases the rail potential. When the braking train supplies power to the accelerating train outside the power supply section in the metro line, the rail potential of some part of the line increases. The OVPD operation increases the ground potential around the station grounding gird, and may lead to the continuous operation of other OVPD in the metro line.


  • Open Access

    State Identification of Transformer Under DC Bias Based on Wavelet Singular Entropy

    by Jun Liu, Huarong Zeng, Wei Niu, Peilong Chen, Kui Xu, Peng Zeng, Lu Zhao, Sheng Lin

    To identify the DC bias state of transformers, a DC bias state identification method of transformer based on wavelet singular entropy is proposed in this paper. The vibration principle of transformers under DC bias has been analyzed. By combining continuous wavelet transform, singular value decomposition, and information entropy, the analysis method of wavelet singular entropy is proposed. The vibration signal of the transformer before and after DC bias is transformed by continuous wavelet transform, and then the wavelet time-frequency diagram is compared and analyzed. Furthermore, the DC bias state of the transformer is identified by wavelet singular entropy of vibration signal. The wavelet singular entropy under different states is in different numerical ranges, and the wavelet singular entropy of vibration signal under DC bias is significantly greater than that under no DC bias. The wavelet singular entropy effectively reflects the DC bias state of transformers. Then the proposed method is applied to a 500 kV transformer and a 220 kV transformer in the China Southern Power Grid. The results show that the proposed method can accurately and effectively identify the DC bias state of transformers.