Milan Holy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Milan Holy has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- David Čítek
Klokner Institute, Czech Technical University in Prague, 166 08 Prague, Czech Republic
6 shared publications Petr Tej
4 shared publications- Jiří Kolisko
Czech Technical University in Prague
3 shared publications Jiří Kolísko
Czech Technical University in Prague, Klokner Institute, Šolínova 7, Prague 166 08, Czech Republic
2 shared publications- Jiří Prchlík
Czech Technical University in Prague
2 shared publications Lukáš Vrablik
Czech Technical University in Prague
2 shared publications
Latest Publications
- 18 May 2026
- Published by Trans Tech Publications, Ltd. in Advances in Science and Technology
- Vol. 176, 17-27
Medium Span Footbridge System Using UHPC
The topic of medium-span bridges combined with longitudinal segmentation of the structure using precast components made of UHPC material was a challenge for the grant research team. The researchers' goal was to optimize the shape of the parapet beam from both a structural and architectural perspective. It was necessary to find the most suitable solution for connecting the beams to the bridge deck and to design the technology for manufacturing the individual structural elements and connecting them into a single functional unit. All this had to be done with an emphasis on maintaining the required parameters for safe and secure operation of the structure.The article presents a new Medium Span Footbridge System (MSFS) with a span of up to 30 meters. The system consists of a combination of parapet beams with longitudinal prestressing, ribbed bridge deck slabs, and grout joints. The article mentions the static analysis of the structure. The method of manufacturing individual parts is documented, together with the specific procedure for constructing the footbridge, which is designed to minimize work on the construction site while minimizing traffic restrictions under the footbridge under construction. The article also presents a functional sample of the structure – the first medium-span footbridge (MSF) made of UHPC with a span of 26.0 m and a clear width of 3.0 m.
- 18 May 2026
- Published by Trans Tech Publications, Ltd. in Advances in Science and Technology
- Vol. 176, 17-27
Medium Span Footbridge System Using UHPC
The topic of medium-span bridges combined with longitudinal segmentation of the structure using precast components made of UHPC material was a challenge for the grant research team. The researchers' goal was to optimize the shape of the parapet beam from both a structural and architectural perspective. It was necessary to find the most suitable solution for connecting the beams to the bridge deck and to design the technology for manufacturing the individual structural elements and connecting them into a single functional unit. All this had to be done with an emphasis on maintaining the required parameters for safe and secure operation of the structure.The article presents a new Medium Span Footbridge System (MSFS) with a span of up to 30 meters. The system consists of a combination of parapet beams with longitudinal prestressing, ribbed bridge deck slabs, and grout joints. The article mentions the static analysis of the structure. The method of manufacturing individual parts is documented, together with the specific procedure for constructing the footbridge, which is designed to minimize work on the construction site while minimizing traffic restrictions under the footbridge under construction. The article also presents a functional sample of the structure – the first medium-span footbridge (MSF) made of UHPC with a span of 26.0 m and a clear width of 3.0 m.
- 18 May 2026
- Published by Trans Tech Publications, Ltd. in Advances in Science and Technology
- Vol. 176, 175-184
Analysis of a Dam Embankment in Terms of Hydration Heat and Shrinkage
This paper deals with the stress analysis and prediction of crack formation caused by the development of hydration heat and shrinkage in the expansion block of the Nové Heřminovy dam. During the design of the concrete gravity dam, extensive analysis were carried out in order to predict the occurrence of cracks induced by hydration heat development and shrinkage within the first 10 years after the start of construction. The aim of the analysis was to predict the location, depth, and width of cracks under given conditions and to provide recommendations for minimizing crack formation in the structure. In the first stage, a parametric study on a sectional model was carried out, which led to the optimization of technological procedures and the concreting schedule. Subsequently, a global model of a typical gravity block of the dam was created to simulate the boundary conditions of the structure as accurately as possible during construction and subsequent operation, and to obtain results regarding stress distribution and areas with a risk of cracking. The analysis was performed using nonlinear numerical calculations in ATENA software, while also incorporating transport analysis of temperature and environmental humidity.
- 18 May 2026
- Published by Trans Tech Publications, Ltd. in Advances in Science and Technology
- Vol. 176, 175-184
Analysis of a Dam Embankment in Terms of Hydration Heat and Shrinkage
This paper deals with the stress analysis and prediction of crack formation caused by the development of hydration heat and shrinkage in the expansion block of the Nové Heřminovy dam. During the design of the concrete gravity dam, extensive analysis were carried out in order to predict the occurrence of cracks induced by hydration heat development and shrinkage within the first 10 years after the start of construction. The aim of the analysis was to predict the location, depth, and width of cracks under given conditions and to provide recommendations for minimizing crack formation in the structure. In the first stage, a parametric study on a sectional model was carried out, which led to the optimization of technological procedures and the concreting schedule. Subsequently, a global model of a typical gravity block of the dam was created to simulate the boundary conditions of the structure as accurately as possible during construction and subsequent operation, and to obtain results regarding stress distribution and areas with a risk of cracking. The analysis was performed using nonlinear numerical calculations in ATENA software, while also incorporating transport analysis of temperature and environmental humidity.
- Open Access
- 1 March 2026
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 22 (1) , 469-480
Evaluation of Diagnostics and Recalculations of Several Czech Masonry Arch Railway Bridges
Masonry arch bridges on the railway in the Czech Republic are connected with the construction and development of the railway network in the second half of the 19th century. Many of them have been in service for about 150 years, some of them even for over 180 years. Nowadays, these historical types of bridge structures are not newly designed. Their durability is extraordinary compared to current structures. It can be assumed, that in case of proper maintenance, most of them can serve well for another tens or hundreds of years. Diagnostic surveys and structural recalculations of several masonry arch bridges were carried out between 2022 and 2024 as part of the project “Diagnostics and Recalculations of Strategic Bridges” organized by Czech Railway administration. In this paper, the investigated structures (generally monumental multi-span viaducts) are introduced, their typical failures and problems are presented, and their static reliability is evaluated. The specific approach to performing diagnostic surveys and recalculations of these historical structures is also discussed in detail. In the case of arched masonry structures, the structural analysis and determination of load-bearing capacity is complicated by the complex static behaviour of masonry arched structures combined with typical masonry properties characterised by non-linear behaviour.
- 1 March 2026
- Published by Walter de Gruyter GmbH in Civil and Environmental Engineering
- Vol. 22 (1) , 469-480
Open AccessEvaluation of Diagnostics and Recalculations of Several Czech Masonry Arch Railway Bridges
Masonry arch bridges on the railway in the Czech Republic are connected with the construction and development of the railway network in the second half of the 19th century. Many of them have been in service for about 150 years, some of them even for over 180 years. Nowadays, these historical types of bridge structures are not newly designed. Their durability is extraordinary compared to current structures. It can be assumed, that in case of proper maintenance, most of them can serve well for another tens or hundreds of years. Diagnostic surveys and structural recalculations of several masonry arch bridges were carried out between 2022 and 2024 as part of the project “Diagnostics and Recalculations of Strategic Bridges” organized by Czech Railway administration. In this paper, the investigated structures (generally monumental multi-span viaducts) are introduced, their typical failures and problems are presented, and their static reliability is evaluated. The specific approach to performing diagnostic surveys and recalculations of these historical structures is also discussed in detail. In the case of arched masonry structures, the structural analysis and determination of load-bearing capacity is complicated by the complex static behaviour of masonry arched structures combined with typical masonry properties characterised by non-linear behaviour.
- Open Access
- 12 July 2025
- Published by Czech Technical University in Prague - Central Library in Acta Polytechnica CTU Proceedings
- Vol. 53, 42-48
Parametric study of a reinforced concrete footbridge strengthened by a layer of UHPFRC
This paper deals with the presentation of a parametric study of the strengthening of a reinforced concrete footbridge with a layer of reinforced UHPFRC on its upper surface. In order to increase its load carrying capacity, stiffness and durability, the design of strengthening with 50 mm thick UHPFRC layer was carried out. The geometry of the analyzed structure is based on the real structure. The parametric study solves its strengthening by considering different support options of the structure and its degradation. The design and assessment was carried out in the form of nonlinear numerical analysis using the FEM in Atena 3D.
- 12 July 2025
- Published by Czech Technical University in Prague - Central Library in Acta Polytechnica CTU Proceedings
- Vol. 53, 42-48
Open AccessParametric study of a reinforced concrete footbridge strengthened by a layer of UHPFRC
This paper deals with the presentation of a parametric study of the strengthening of a reinforced concrete footbridge with a layer of reinforced UHPFRC on its upper surface. In order to increase its load carrying capacity, stiffness and durability, the design of strengthening with 50 mm thick UHPFRC layer was carried out. The geometry of the analyzed structure is based on the real structure. The parametric study solves its strengthening by considering different support options of the structure and its degradation. The design and assessment was carried out in the form of nonlinear numerical analysis using the FEM in Atena 3D.
- 30 May 2025
- Published by Trans Tech Publications, Ltd. in Advances in Science and Technology
- Vol. 164, 75-82
Probabilistic Model for Thermal Actions on Concrete Bridges Based on Meteorological Measurements - Case Study
Reliability assessments of concrete bridges are currently made using valid codes of practice based on the limit state concept. Verification may be carried out using the partial factor format or structural reliability methods. The reliability assessment should be made taking into account the service life of a structure, the selected reference period, and the changes in the environment of the structure and possibly anticipated changes in use. This contribution focuses on the verification of models for thermal actions for concrete bridges. An example of updating the design value and partial factor for thermal actions using site-specific measurements—shade air temperature measurements and on-bridge measurements—is developed. Two probabilistic models are employed to characterise annual extremes of ambient air temperatures and the effect of choice of the distribution on the partial factor for thermal actions is discussed. It appears that on-bridge measurements may significantly improve the model for both uniform temperature and temperature difference components in comparison to the EN 1991-1-5 model, with reduction of the design value up to 30% in the case study. A useful alternative for practical applications is to update thermal action effects using records from the nearest meteorological station (reduction about 20%). Using either meteorological or on-bridge measurements, the partial factor can be decreased to 1.2 for the uniform temperature component and to 1.3 for the difference temperature component. The choice of probabilistic distribution seems to be of low importance for the bridge under consideration. Further research should be mainly focused on investigating the effects of climate change and analysis of thermal action effects on different types of concrete bridges and bridges from other structural materials.
- 30 May 2025
- Published by Trans Tech Publications, Ltd. in Advances in Science and Technology
- Vol. 164, 75-82
Probabilistic Model for Thermal Actions on Concrete Bridges Based on Meteorological Measurements - Case Study
Reliability assessments of concrete bridges are currently made using valid codes of practice based on the limit state concept. Verification may be carried out using the partial factor format or structural reliability methods. The reliability assessment should be made taking into account the service life of a structure, the selected reference period, and the changes in the environment of the structure and possibly anticipated changes in use. This contribution focuses on the verification of models for thermal actions for concrete bridges. An example of updating the design value and partial factor for thermal actions using site-specific measurements—shade air temperature measurements and on-bridge measurements—is developed. Two probabilistic models are employed to characterise annual extremes of ambient air temperatures and the effect of choice of the distribution on the partial factor for thermal actions is discussed. It appears that on-bridge measurements may significantly improve the model for both uniform temperature and temperature difference components in comparison to the EN 1991-1-5 model, with reduction of the design value up to 30% in the case study. A useful alternative for practical applications is to update thermal action effects using records from the nearest meteorological station (reduction about 20%). Using either meteorological or on-bridge measurements, the partial factor can be decreased to 1.2 for the uniform temperature component and to 1.3 for the difference temperature component. The choice of probabilistic distribution seems to be of low importance for the bridge under consideration. Further research should be mainly focused on investigating the effects of climate change and analysis of thermal action effects on different types of concrete bridges and bridges from other structural materials.
- 18 March 2024
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 976, 121-128
The Impact of Hydration Heat on the Formation of Cracks in Massive Concrete Structures
The article deals with the analysis of the development of hydration heat in massive concrete structures and focuses mainly on risk factors which could lead to the appearance of early age cracking in the structure shortly after concreting. As part of the analysis, a parametric study was carried out, which was focused not only on the size of cracks on the surface of the structure, but also on the evaluation of the temperature gradient, where the ratio of the temperature difference and the distance between two points was investigated. During the study, different variants of the type and length of surface covering and different boundary conditions in terms of ambient temperature during individual seasons were considered. The numerical analysis was performed using nonlinear numerical calculations in ATENA software. At the conclusion, an evaluation of the effect of different types of covering of the concrete structure on the reduction of the number and size of surface cracks caused by hydration heat is carried out.
- 18 March 2024
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 976, 121-128
The Impact of Hydration Heat on the Formation of Cracks in Massive Concrete Structures
The article deals with the analysis of the development of hydration heat in massive concrete structures and focuses mainly on risk factors which could lead to the appearance of early age cracking in the structure shortly after concreting. As part of the analysis, a parametric study was carried out, which was focused not only on the size of cracks on the surface of the structure, but also on the evaluation of the temperature gradient, where the ratio of the temperature difference and the distance between two points was investigated. During the study, different variants of the type and length of surface covering and different boundary conditions in terms of ambient temperature during individual seasons were considered. The numerical analysis was performed using nonlinear numerical calculations in ATENA software. At the conclusion, an evaluation of the effect of different types of covering of the concrete structure on the reduction of the number and size of surface cracks caused by hydration heat is carried out.
- Open Access
- 4 June 2023
- Published by Iowa State University
- Vol. 3 (1)
Development of Short Span and Medium Span Footbridge Systems using UHPFRC in Czech Republic
In the first part, this paper presents the experimental development of an innovative medium span footbridge system made of UHPFRC. The load bearing structure is designed as a U-shaped beam and consists of 2 main precast prestressed beams, which are connected with precast bridge deck segments. This system is different from the commonly used segmental footbridge structures because a longitudinal prefabrication is used. The development of this system was initiated for several reasonsno need to assemble a falsework and a formwork in situ, no need for heavy cranes, the main load-bearing structure does not contain transverse joints, a possibility to prestress the structure in advance in factory. In the other part, the article discusses another system of shortspan footbridges made of UHPFRC designed and used in the Czech Republic. These footbridges are in the shape of a slab with ribs, and they are manufactured and placed on the substructure as a whole, so they represent an advantage especially in terms of construction speed and low maintenance requirements.
- 4 June 2023
- Published by Iowa State University
- Vol. 3 (1)
Open AccessDevelopment of Short Span and Medium Span Footbridge Systems using UHPFRC in Czech Republic
In the first part, this paper presents the experimental development of an innovative medium span footbridge system made of UHPFRC. The load bearing structure is designed as a U-shaped beam and consists of 2 main precast prestressed beams, which are connected with precast bridge deck segments. This system is different from the commonly used segmental footbridge structures because a longitudinal prefabrication is used. The development of this system was initiated for several reasonsno need to assemble a falsework and a formwork in situ, no need for heavy cranes, the main load-bearing structure does not contain transverse joints, a possibility to prestress the structure in advance in factory. In the other part, the article discusses another system of shortspan footbridges made of UHPFRC designed and used in the Czech Republic. These footbridges are in the shape of a slab with ribs, and they are manufactured and placed on the substructure as a whole, so they represent an advantage especially in terms of construction speed and low maintenance requirements.
- 7 March 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 51
Timber-UHPFRC composite connection – Analysis and experiments
- 7 March 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 51
Timber-UHPFRC composite connection – Analysis and experiments
- 9 August 2021
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 322, 176-184
Implementation and Testing of Short Span Footbridge System Made of UHPC
This paper presents the results of testing and the first application of a newly developed innovative system of the bridge superstructures made of UHPC material. Being designed for footbridges it is called short span footbridge system - SSFS. This system was developed for a wide range of uses mainly as footbridges for pedestrians and cyclists and without waterproofing or surfacing. Prestressed prefabricated elements work as single-span beams with a span of up to 20 meters. Thanks to the optimization of the geometry design and the advantageous use of the mechanical properties of the UHPC material in combination with the prestressing, it was possible to achieve a very small construction height. These subtle and light load-bearing components tend to move away from traditional concrete structures, their span-to-depth ratios are closer to steel beams, but the needs for corrosion protection are eliminated using UHPC, which is inherently very durable and therefore almost maintenance-free. SSFS elements can be manufactured with a variable width of up to approx. 3.2 m, but they can be connected transversely and therefore the width of the structure is not limited. The first part of the paper is devoted to the development of the system and real applications of the first few footbridges made of UHPC material and other possibilities of this technology for future applications. The second part of the paper mentions the design and experimental verification of anchoring devices that are used to manipulate small-span footbridges made of UHPC.
- 9 August 2021
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 322, 176-184
Implementation and Testing of Short Span Footbridge System Made of UHPC
This paper presents the results of testing and the first application of a newly developed innovative system of the bridge superstructures made of UHPC material. Being designed for footbridges it is called short span footbridge system - SSFS. This system was developed for a wide range of uses mainly as footbridges for pedestrians and cyclists and without waterproofing or surfacing. Prestressed prefabricated elements work as single-span beams with a span of up to 20 meters. Thanks to the optimization of the geometry design and the advantageous use of the mechanical properties of the UHPC material in combination with the prestressing, it was possible to achieve a very small construction height. These subtle and light load-bearing components tend to move away from traditional concrete structures, their span-to-depth ratios are closer to steel beams, but the needs for corrosion protection are eliminated using UHPC, which is inherently very durable and therefore almost maintenance-free. SSFS elements can be manufactured with a variable width of up to approx. 3.2 m, but they can be connected transversely and therefore the width of the structure is not limited. The first part of the paper is devoted to the development of the system and real applications of the first few footbridges made of UHPC material and other possibilities of this technology for future applications. The second part of the paper mentions the design and experimental verification of anchoring devices that are used to manipulate small-span footbridges made of UHPC.
- 9 August 2021
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 322, 157-162
Production of the Test Timber-UHPC Composite Bridge
This article presents the results of the experimental development of a unique bridge system consisting of timber beams connected with bridge deck segments made of Ultra-High Performance Concrete (UHPC). The article deals with the production of a full-scale prototype of the timber-concrete composite structure and with an execution of a subsequent load test. The test structure was 3.30 m wide and 10.24 m long and was designed as two beams made of glue laminated timber connected with subtle bridge deck segments with a thickness only 60 mm and with a typical length of 1.50 m. The aim of the production of the test structure was to check some production details and procedures and subsequently to verify the behavior of the composite structure under load by the load test. The load test was performed with a theoretical span of 9.50 m as a four-point bending test to failure. After the overall load test was done, some bridge deck segments were cut from the structure and a load test of the bridge deck in transversal direction were executed to verify the behavior and the load-bearing capacity of the bridge deck segments made of UHPC.
- 9 August 2021
- Published by Trans Tech Publications, Ltd. in Solid State Phenomena
- Vol. 322, 157-162
Production of the Test Timber-UHPC Composite Bridge
This article presents the results of the experimental development of a unique bridge system consisting of timber beams connected with bridge deck segments made of Ultra-High Performance Concrete (UHPC). The article deals with the production of a full-scale prototype of the timber-concrete composite structure and with an execution of a subsequent load test. The test structure was 3.30 m wide and 10.24 m long and was designed as two beams made of glue laminated timber connected with subtle bridge deck segments with a thickness only 60 mm and with a typical length of 1.50 m. The aim of the production of the test structure was to check some production details and procedures and subsequently to verify the behavior of the composite structure under load by the load test. The load test was performed with a theoretical span of 9.50 m as a four-point bending test to failure. After the overall load test was done, some bridge deck segments were cut from the structure and a load test of the bridge deck in transversal direction were executed to verify the behavior and the load-bearing capacity of the bridge deck segments made of UHPC.