Guangdou Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Guangdou Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jian Li
University of Electronic Science and Technology of China
10 shared publications - Qi Huang
University of Electronic Science and Technology of China
7 shared publications - Yankai Xing
College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu, China
6 shared publications - Dongsheng Cai
College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, Sichuan, China
4 shared publications Olusola Bamisile
College of Nuclear Technology and Automation Engineering, Chengdu University of Technology, P.R. China
3 shared publications- Chongqing Kang
Department of Electrical Engineering, Tsinghua University, Beijing, China
2 shared publications
Latest Publications
- 30 October 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Low-carbon collaborative scheduling of industrial microgrids with electrolytic aluminum load considering electricity-carbon trading
- 30 October 2026
- Published by Elsevier in Applied Energy
- Vol. 427
Low-carbon collaborative scheduling of industrial microgrids with electrolytic aluminum load considering electricity-carbon trading
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Current Reconstruction and Sag/Wind Deflection Monitoring of Transmission Lines by Magnetic Sensing
The non-intrusive condition monitoring of overhead transmission lines is a key method to ensuring the safe and stable operation of transmission systems. Especially, their sag/wind deflection are important parameters that should be monitored along with its current. In this paper, an innovative approach for non-contact and cost-effective monitoring of High Voltage Overhead Transmission Lines (HVOTLs) is developed, utilizing three uni-axis magnetic sensors strategically positioned on the tower, below (or above) the transmission lines. Initially, a magnetic field decoupling method in the context of spatial state variations across multiple conductors is proposed. Subsequently, an algorithm is presented to perform sag estimation, wind deflection detection, as well as current reconstruction. The efficacy of the proposed approach is corroborated through numerical simulations and finite-element analysis (FEA). Further validation is achieved using a scaled-down model in laboratory, reinforcing the practical feasibility of the method.
- 28 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-13
Current Reconstruction and Sag/Wind Deflection Monitoring of Transmission Lines by Magnetic Sensing
The non-intrusive condition monitoring of overhead transmission lines is a key method to ensuring the safe and stable operation of transmission systems. Especially, their sag/wind deflection are important parameters that should be monitored along with its current. In this paper, an innovative approach for non-contact and cost-effective monitoring of High Voltage Overhead Transmission Lines (HVOTLs) is developed, utilizing three uni-axis magnetic sensors strategically positioned on the tower, below (or above) the transmission lines. Initially, a magnetic field decoupling method in the context of spatial state variations across multiple conductors is proposed. Subsequently, an algorithm is presented to perform sag estimation, wind deflection detection, as well as current reconstruction. The efficacy of the proposed approach is corroborated through numerical simulations and finite-element analysis (FEA). Further validation is achieved using a scaled-down model in laboratory, reinforcing the practical feasibility of the method.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (4) , 3966-3978
A Robust V2G Voltage Control Scheme for Distribution Networks Against Cyber Attacks and Customer Interruptions
A decent vehicle-to-grid (V2G) control scheme improves voltage stability and grid reliability of distribution networks (DNs) by providing reactive power and ancillary services. However, unknown malicious attacks in cyber layers and uncertain EV charging/unplugging in physical layers will disturb the measurement process, leading to controller parameters’ mismatching and severe voltage violations. This paper proposes a robust V2G voltage control scheme for DNs investigating cyber attacks and EV customer interruptions. Firstly, the impact of cyber attacks is characterized by time-varying uncertain matrices function with Lebesgur measurable elements, while the EV customer interruptions are represented by Signum variables. Then, a new state-space equation for V2G voltage control in DNs is constructed by incorporating above matrices function and Signum variables. Moreover, a robust voltage controller is proposed for measurement disordered V2G systems to suppress voltage violations while achieving H∞ performance. By utilizing linear matrix inequality (LMI) techniques, sufficient conditions for system closed-loop exponentially mean-square stability and the controller parameter tuning are presented. Case studies conducted on modified IEEE European low voltage test feeder compare two voltage deviation indices of the proposed controller with those of existing methods, verifying the effectiveness of the proposed approach against measurement anomalies.
- 12 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 15 (4) , 3966-3978
A Robust V2G Voltage Control Scheme for Distribution Networks Against Cyber Attacks and Customer Interruptions
A decent vehicle-to-grid (V2G) control scheme improves voltage stability and grid reliability of distribution networks (DNs) by providing reactive power and ancillary services. However, unknown malicious attacks in cyber layers and uncertain EV charging/unplugging in physical layers will disturb the measurement process, leading to controller parameters’ mismatching and severe voltage violations. This paper proposes a robust V2G voltage control scheme for DNs investigating cyber attacks and EV customer interruptions. Firstly, the impact of cyber attacks is characterized by time-varying uncertain matrices function with Lebesgur measurable elements, while the EV customer interruptions are represented by Signum variables. Then, a new state-space equation for V2G voltage control in DNs is constructed by incorporating above matrices function and Signum variables. Moreover, a robust voltage controller is proposed for measurement disordered V2G systems to suppress voltage violations while achieving H∞ performance. By utilizing linear matrix inequality (LMI) techniques, sufficient conditions for system closed-loop exponentially mean-square stability and the controller parameter tuning are presented. Case studies conducted on modified IEEE European low voltage test feeder compare two voltage deviation indices of the proposed controller with those of existing methods, verifying the effectiveness of the proposed approach against measurement anomalies.
- 9 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Non-Contact Voltage Reconstruction Method Based on Dual-Pin Type Probes Structure and Measuring Point Optimization for AC Overhead Transmission Lines
With increasing requirements of online monitoring of Overhead Transmission Lines (OTL) in smart grids, contact-free measurement technologies have been updated these decades. However, the contactless sensors in past research are still limited to the application environment like wind deflection. This paper proposes an advanced detection approach with a novel structure to enhance the possibility of implementation and reduce cost. Three pairs of detection probes arranged in a curved pattern can collect differential voltage signals based on the principle of electric field radiation. With three-phase vector decomposition, the 9 unknown variables including voltage to be measured and status of lines (sag and wind deflection) in 9 equations can be constructed. The voltages to be measured can be calculated by solving this nonlinear equation system by iteration. Also, the position of the device installation is optimized by Particle Swarm Optimization (PSO) algorithm regarding accuracy. The whole measurement device can be easily implemented on the towers according to the distance of insulation requirement regardless of the position of lines. The simulation of level 110 kV is investigated and a model system is built to measure a lower-level voltage for verification. The results show that the proposed non-contact OTL voltage approach can reach the desired accuracy with low costs and monitor the status of lines.
- 9 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
Non-Contact Voltage Reconstruction Method Based on Dual-Pin Type Probes Structure and Measuring Point Optimization for AC Overhead Transmission Lines
With increasing requirements of online monitoring of Overhead Transmission Lines (OTL) in smart grids, contact-free measurement technologies have been updated these decades. However, the contactless sensors in past research are still limited to the application environment like wind deflection. This paper proposes an advanced detection approach with a novel structure to enhance the possibility of implementation and reduce cost. Three pairs of detection probes arranged in a curved pattern can collect differential voltage signals based on the principle of electric field radiation. With three-phase vector decomposition, the 9 unknown variables including voltage to be measured and status of lines (sag and wind deflection) in 9 equations can be constructed. The voltages to be measured can be calculated by solving this nonlinear equation system by iteration. Also, the position of the device installation is optimized by Particle Swarm Optimization (PSO) algorithm regarding accuracy. The whole measurement device can be easily implemented on the towers according to the distance of insulation requirement regardless of the position of lines. The simulation of level 110 kV is investigated and a model system is built to measure a lower-level voltage for verification. The results show that the proposed non-contact OTL voltage approach can reach the desired accuracy with low costs and monitor the status of lines.
- 3 October 2023
- Published by Elsevier in ISA Transactions
- Vol. 143, 440-457
Data-driven load frequency cooperative control for multi-area power system integrated with VSCs and EV aggregators under cyber-attacks
- 3 October 2023
- Published by Elsevier in ISA Transactions
- Vol. 143, 440-457
Data-driven load frequency cooperative control for multi-area power system integrated with VSCs and EV aggregators under cyber-attacks
- 28 September 2023
- Published by Elsevier in ISA Transactions
- Vol. 143, 492-502
Vulnerability analysis and modeling false data injection attack against voltage source converter in renewable generation power system
- 28 September 2023
- Published by Elsevier in ISA Transactions
- Vol. 143, 492-502
Vulnerability analysis and modeling false data injection attack against voltage source converter in renewable generation power system
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Advanced Dual-Probes Noncontact Voltage Measurement Approach for AC/DC Power Transmission Wire Based on the Electric Field Radiation Principle
The contact-free measurement of current and voltage technologies are key points to achieve online monitoring tasks in the modern power system, which are updated in these decades. However, ensuring accuracy and a convenient level of operation in the meanwhile is also a difficult task that needs to be solved in advance. Besides, there are unidealized situations in the process of application of existence measure methods. According to the principle of electric field radiation, this paper proposes a non-contact voltage measurement approach based on three pairs of dual-probes circle measurement structures to measure the voltage of transmission wire online. Compared with the other methods, firstly, in this proposed approach, the sensor structure is optimized to be simple, low-cost, and easy to install and operate. Secondly, the potential error in the measuring process caused by the other electric field in the environment is eliminated with dual probes, and the influence of unidealized situations like off-center wire can be also avoided by calculating algorithm. Third, in no matter DC (Direct Current)/AC (Alternating Current) monitoring scenarios, with the proposed structure and methodology, the accuracy can be ensured to reach the acceptance level (below 1.63 %) even when the core of the wire to be measured is in any position instead of in the center. In the final, the simulation results and circuit tests verify these advantages to encourage us to implement them in the realistic power system.
- 14 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
Advanced Dual-Probes Noncontact Voltage Measurement Approach for AC/DC Power Transmission Wire Based on the Electric Field Radiation Principle
The contact-free measurement of current and voltage technologies are key points to achieve online monitoring tasks in the modern power system, which are updated in these decades. However, ensuring accuracy and a convenient level of operation in the meanwhile is also a difficult task that needs to be solved in advance. Besides, there are unidealized situations in the process of application of existence measure methods. According to the principle of electric field radiation, this paper proposes a non-contact voltage measurement approach based on three pairs of dual-probes circle measurement structures to measure the voltage of transmission wire online. Compared with the other methods, firstly, in this proposed approach, the sensor structure is optimized to be simple, low-cost, and easy to install and operate. Secondly, the potential error in the measuring process caused by the other electric field in the environment is eliminated with dual probes, and the influence of unidealized situations like off-center wire can be also avoided by calculating algorithm. Third, in no matter DC (Direct Current)/AC (Alternating Current) monitoring scenarios, with the proposed structure and methodology, the accuracy can be ensured to reach the acceptance level (below 1.63 %) even when the core of the wire to be measured is in any position instead of in the center. In the final, the simulation results and circuit tests verify these advantages to encourage us to implement them in the realistic power system.
- Top Cited Papers
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (2) , 1336-1349
An ${H_\infty }$ Load Frequency Control Scheme for Multi-Area Power System Under Cyber-Attacks and Time-Varying DelaysIn the power system, the application of the signals transmitted from the sensors to the controller can significantly improve the dynamic performance. However, cyber-attacks and time delays exist widely in the communication network, which has a considerable effect on stability, operation, and control. In this paper, an H_ load frequency control (LFC) scheme for multi-area power systems under cyber-attacks and time-varying delays is investigated. First, false date injection attacks (FDIA), as well as denial of service (DoS) attacks, are viewed as two typical cyber-attacks and introduced into the multi-area power system. Then, the state-space equations of the LFC power system under these two attacks and time-varying delays are analyzed and modeled. Furthermore, by using Lyapunov stability theory and linear matrix inequality (LMI) method, an H_ LFC scheme for attacked and delayed power systems is developed. The purpose of the proposed controller is to guarantee the closed-loop system exponentially mean-square stable with prescribed H_ performance. Finally, a three-area LFC system is employed to demonstrate the effectiveness of the proposed mechanism. The simulation results verified that the control performance of an attacked and delayed system can be improved significantly via the designed controller.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (2) , 1336-1349
Top Cited PapersAn ${H_\infty }$ Load Frequency Control Scheme for Multi-Area Power System Under Cyber-Attacks and Time-Varying DelaysIn the power system, the application of the signals transmitted from the sensors to the controller can significantly improve the dynamic performance. However, cyber-attacks and time delays exist widely in the communication network, which has a considerable effect on stability, operation, and control. In this paper, an H_ load frequency control (LFC) scheme for multi-area power systems under cyber-attacks and time-varying delays is investigated. First, false date injection attacks (FDIA), as well as denial of service (DoS) attacks, are viewed as two typical cyber-attacks and introduced into the multi-area power system. Then, the state-space equations of the LFC power system under these two attacks and time-varying delays are analyzed and modeled. Furthermore, by using Lyapunov stability theory and linear matrix inequality (LMI) method, an H_ LFC scheme for attacked and delayed power systems is developed. The purpose of the proposed controller is to guarantee the closed-loop system exponentially mean-square stable with prescribed H_ performance. Finally, a three-area LFC system is employed to demonstrate the effectiveness of the proposed mechanism. The simulation results verified that the control performance of an attacked and delayed system can be improved significantly via the designed controller.
- 2 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 750-761
Spatio-Temporal Correlation-Based False Data Injection Attack Detection Using Deep Convolutional Neural Network
There are lots of cyber-attack, especially false data injection attacks, in modern power systems. This attack can circumvent traditional residual-based detection methods, and destroy the integrity of control information, thus hindering the stability of the power system. In this paper, a novel Spatio-temporal detection mechanism is proposed to evaluate and locate false data injection attacks. In the proposed method, temporal correlation and spatial correlation are analyzed by cubature Kalman filter and Gaussian process regression, respectively, to capture the dynamic features of state vectors. Then, a deep convolutional neural network is trained to depict the functional relationship between Spatio-temporal correlation functions and the output, which is set as the detection indicator to access whether the power system under attack or not. Furthermore, the performance of the proposed mechanism is evaluated with comprehensive numerical simulation on IEEE 39-bus test system. The results of the case studies showed that the proposed method can achieve 99.84%-100% accuracy.
- 2 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 13 (1) , 750-761
Spatio-Temporal Correlation-Based False Data Injection Attack Detection Using Deep Convolutional Neural Network
There are lots of cyber-attack, especially false data injection attacks, in modern power systems. This attack can circumvent traditional residual-based detection methods, and destroy the integrity of control information, thus hindering the stability of the power system. In this paper, a novel Spatio-temporal detection mechanism is proposed to evaluate and locate false data injection attacks. In the proposed method, temporal correlation and spatial correlation are analyzed by cubature Kalman filter and Gaussian process regression, respectively, to capture the dynamic features of state vectors. Then, a deep convolutional neural network is trained to depict the functional relationship between Spatio-temporal correlation functions and the output, which is set as the detection indicator to access whether the power system under attack or not. Furthermore, the performance of the proposed mechanism is evaluated with comprehensive numerical simulation on IEEE 39-bus test system. The results of the case studies showed that the proposed method can achieve 99.84%-100% accuracy.