John A. Moore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
John A. Moore has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
Ayushi Chandel
3 shared publicationsCaitlin Martinez
3 shared publications- Dinc Erdeniz
Northwestern University
2 shared publications Alvaro R. Arce-Borkent
Department of Mechanical Engineering, University of Alberta, Edmonton, Canada
1 shared publication- Amina E. Hussein
Department of Electrical and Computer Engineering, University of Alberta 4 , Edmonton, Alberta T6G 1H9
1 shared publication - Amina E. Hussein
Department of Electrical and Computer Engineering, University of Alberta, Edmonton, Canada
1 shared publication
Latest Publications
- Open Access
- 24 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
X-ray tomography of damage dynamics in advanced materials using a laser wakefield accelerator
Additively manufactured (AM) metals offer the potential for customizable, cost-effective components, but qualification and certification are crucial. Key to this process is understanding pore dynamics under stress, typically analyzed using micro-computed tomography. This study introduces laboratory-scale “betatron” x-rays from laser wakefield acceleration as a high-throughput alternative for x-ray tomography of advanced materials, such as AM AlSi10Mg alloys. Coupled with 3D finite element modeling, this method provides detailed insights into stress-porosity interactions. The approach delivers high-resolution scans, revealing that pore shape and local triaxiality significantly influence fracture dynamics, supporting advanced material characterization. This work also demonstrates the potential and versatility of laser-betatron x-ray \(\upmu\)CT for generating large datasets to accelerate our understanding of the stochastic, process-specific nature of pore formation in AM alloys.- 24 April 2026
- Published by Springer Nature in Scientific Reports
- Vol. 16 (1)
Open AccessX-ray tomography of damage dynamics in advanced materials using a laser wakefield accelerator
Additively manufactured (AM) metals offer the potential for customizable, cost-effective components, but qualification and certification are crucial. Key to this process is understanding pore dynamics under stress, typically analyzed using micro-computed tomography. This study introduces laboratory-scale “betatron” x-rays from laser wakefield acceleration as a high-throughput alternative for x-ray tomography of advanced materials, such as AM AlSi10Mg alloys. Coupled with 3D finite element modeling, this method provides detailed insights into stress-porosity interactions. The approach delivers high-resolution scans, revealing that pore shape and local triaxiality significantly influence fracture dynamics, supporting advanced material characterization. This work also demonstrates the potential and versatility of laser-betatron x-ray \(\upmu\)CT for generating large datasets to accelerate our understanding of the stochastic, process-specific nature of pore formation in AM alloys. - 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Laser-driven betatron x rays for high-throughput imaging of additively manufactured materials
Betatron x rays from a laser wakefield accelerator provide a new avenue for high-resolution, high-throughput radiography of solid materials. Here, we demonstrate the optimization of betatron x rays for three-dimensional tomography of defects in additively manufactured (AM) alloys at a repetition rate of 2.5 Hz. Using the Advanced Laser Light Source in Varennes, Qc, we characterized the x-ray energy spectrum, spatial resolution, beam stability, and emission length from three different gas targets {He, N2, and He–N2 [He (99.5%) + N2 (0.5%)] mixture} to determine the conditions for optimized imaging resolution with minimized acquisition time. Mixed He–N2 produced the highest x-ray critical energy (19 ± 5) keV and average brightness (∼3.3×1010 photons/s/mm2/mrad2/0.1% BW) vs pure N2 gas (12 ± 4 keV and ∼1.6×1010 photons/s/mm2/mrad2/0.1% BW). The mixed gas demonstrated the best beam stability and pointing compared to pure He gas. The optimization of betatron sources at 2.5 Hz for high-resolution imaging of micrometer-scale defects in AM alloys will enable high-throughput data collection, accelerating the characterization of complex mechanical deformation processes in these materials.
- 1 December 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (12)
Laser-driven betatron x rays for high-throughput imaging of additively manufactured materials
Betatron x rays from a laser wakefield accelerator provide a new avenue for high-resolution, high-throughput radiography of solid materials. Here, we demonstrate the optimization of betatron x rays for three-dimensional tomography of defects in additively manufactured (AM) alloys at a repetition rate of 2.5 Hz. Using the Advanced Laser Light Source in Varennes, Qc, we characterized the x-ray energy spectrum, spatial resolution, beam stability, and emission length from three different gas targets {He, N2, and He–N2 [He (99.5%) + N2 (0.5%)] mixture} to determine the conditions for optimized imaging resolution with minimized acquisition time. Mixed He–N2 produced the highest x-ray critical energy (19 ± 5) keV and average brightness (∼3.3×1010 photons/s/mm2/mrad2/0.1% BW) vs pure N2 gas (12 ± 4 keV and ∼1.6×1010 photons/s/mm2/mrad2/0.1% BW). The mixed gas demonstrated the best beam stability and pointing compared to pure He gas. The optimization of betatron sources at 2.5 Hz for high-resolution imaging of micrometer-scale defects in AM alloys will enable high-throughput data collection, accelerating the characterization of complex mechanical deformation processes in these materials.
- 10 February 2024
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 895
Effect of wire size on the functional and structural fatigue behavior of superelastic nitinol
- 10 February 2024
- Published by Elsevier in Materials Science and Engineering: A
- Vol. 895
Effect of wire size on the functional and structural fatigue behavior of superelastic nitinol
- Open Access
- 2 November 2023
- Published by Elsevier in Software Impacts
- Vol. 18
NOCAL-FEA: A NonlOCAL results processor for Finite Element Analysis
- 2 November 2023
- Published by Elsevier in Software Impacts
- Vol. 18
Open AccessNOCAL-FEA: A NonlOCAL results processor for Finite Element Analysis
- 25 September 2023
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 46 (12) , 4801-4806
A nonconformal nonlocal approach to calculating statistical spread in fatigue indicator parameters for polycrystals
- 25 September 2023
- Published by Wiley in Fatigue & Fracture of Engineering Materials & Structures
- Vol. 46 (12) , 4801-4806
A nonconformal nonlocal approach to calculating statistical spread in fatigue indicator parameters for polycrystals
- Open Access
- 13 June 2023
- Published by Wiley
A Nonconformal Nonlocal Approach to Calculating Statistical Spread in Fatigue Indicator Parameters for Polycrystals
In the study of fatigue fracture in metals, fatigue indicator parameters (FIPs) are nonlocal quantities that are used to model and predict the driving force needed to incubate fatigue cracks. These FIP values can be used to design materials with microstructural features less prone to fatigue failure. However, the nonlocal nature of fatigue indicator parameters introduces another unknown variable that must be determined for accurate predictions: the volume over which nonlocal averages are performed. Many studies use nonlocal volumes that enclose a predetermined number of finite elements in a polygranular crystal plasticity simulation. To encapsulate the entire microstructure, these nonlocal volumes must be conformal to the microstructure (i.e., they do not overlap or have gaps between them). Some studies base the length scale of these nonlocal volumes on constant values or on the size of relevant microstructural features. It has been shown that if the length scale is too small, the nonlocal FIP predictions are mesh dependent. But, if the length scale is too large, the experimentally observed statistical spread in fatigue life is not captured. This work introduces a nonconformal nonlocal volume (i.e., a volume that surrounds each element and overlaps nonlocal volumes). Averaging FIP over this nonlocal volume both captures the spread in fatigue data and is mesh independent. It also allows for weighted nonlocal averages that would have excluded some of the microstructure using the conformal approach. While this approach is more accurate than the previous approaches, it does require a large amount of computational resources to determine each nonlocal volume, so a parallelized algorithm that is scalable across multiple computing nodes is employed. The example polycrystalline material for this work is Ti-6Al-4V, a common titanium alloy with a hexagonal closed-packed crystal structure.
- 13 June 2023
- Published by Wiley
Open AccessA Nonconformal Nonlocal Approach to Calculating Statistical Spread in Fatigue Indicator Parameters for Polycrystals
In the study of fatigue fracture in metals, fatigue indicator parameters (FIPs) are nonlocal quantities that are used to model and predict the driving force needed to incubate fatigue cracks. These FIP values can be used to design materials with microstructural features less prone to fatigue failure. However, the nonlocal nature of fatigue indicator parameters introduces another unknown variable that must be determined for accurate predictions: the volume over which nonlocal averages are performed. Many studies use nonlocal volumes that enclose a predetermined number of finite elements in a polygranular crystal plasticity simulation. To encapsulate the entire microstructure, these nonlocal volumes must be conformal to the microstructure (i.e., they do not overlap or have gaps between them). Some studies base the length scale of these nonlocal volumes on constant values or on the size of relevant microstructural features. It has been shown that if the length scale is too small, the nonlocal FIP predictions are mesh dependent. But, if the length scale is too large, the experimentally observed statistical spread in fatigue life is not captured. This work introduces a nonconformal nonlocal volume (i.e., a volume that surrounds each element and overlaps nonlocal volumes). Averaging FIP over this nonlocal volume both captures the spread in fatigue data and is mesh independent. It also allows for weighted nonlocal averages that would have excluded some of the microstructure using the conformal approach. While this approach is more accurate than the previous approaches, it does require a large amount of computational resources to determine each nonlocal volume, so a parallelized algorithm that is scalable across multiple computing nodes is employed. The example polycrystalline material for this work is Ti-6Al-4V, a common titanium alloy with a hexagonal closed-packed crystal structure.
- 10 December 2022
- Published by Elsevier in International Journal of Fatigue
- Vol. 168
Effects of martensitic phase transformation on fatigue indicator parameters determined by a crystal plasticity model
- 10 December 2022
- Published by Elsevier in International Journal of Fatigue
- Vol. 168
Effects of martensitic phase transformation on fatigue indicator parameters determined by a crystal plasticity model
- 5 April 2022
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 246-247
A porosity-based model of dynamic compaction in under-dense materials
- 5 April 2022
- Published by Elsevier in International Journal of Solids and Structures
- Vol. 246-247
A porosity-based model of dynamic compaction in under-dense materials
- 23 February 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (8) , 085901
A continuum damage approach to spallation and the role of microinertia
Spall failure is of interest due to its prevalence in high strain rate problems in which the spallation is driven by the interaction of release waves. In this article, a porosity-based damage model that includes microinertial effects is used to examine spall failure. The model is successfully calibrated to plate impact-driven experiments and then used to evaluate experimental conditions producing more extreme strain rate conditions, such as those in laser-driven experiments. The incorporation of microinertia allows us to better understand the increase in apparent macroscopic spall strength seen at high strain rates. Correspondingly, we conclude that the incorporation of microinertial effects improves the model’s predictive capabilities. Microinertial effects result in more severe local tensile stresses that affect the damage evolution, and microinertia can play a significant role in the approach to the material’s ideal strength at extreme loading rates. A preliminary parametric study is also carried out to investigate the role of microstructural aspects such as nucleation volume fraction and initial pore radius. One counter-intuitive result from the microinertial effects is that, for a given nucleation site volume fraction, having larger initial pore nucleation sites can lead to an improved macroscopic spall strength.
- 23 February 2022
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 131 (8) , 085901
A continuum damage approach to spallation and the role of microinertia
Spall failure is of interest due to its prevalence in high strain rate problems in which the spallation is driven by the interaction of release waves. In this article, a porosity-based damage model that includes microinertial effects is used to examine spall failure. The model is successfully calibrated to plate impact-driven experiments and then used to evaluate experimental conditions producing more extreme strain rate conditions, such as those in laser-driven experiments. The incorporation of microinertia allows us to better understand the increase in apparent macroscopic spall strength seen at high strain rates. Correspondingly, we conclude that the incorporation of microinertial effects improves the model’s predictive capabilities. Microinertial effects result in more severe local tensile stresses that affect the damage evolution, and microinertia can play a significant role in the approach to the material’s ideal strength at extreme loading rates. A preliminary parametric study is also carried out to investigate the role of microstructural aspects such as nucleation volume fraction and initial pore radius. One counter-intuitive result from the microinertial effects is that, for a given nucleation site volume fraction, having larger initial pore nucleation sites can lead to an improved macroscopic spall strength.