Yunhee Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yunhee Chang has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Bo Ra Jeong
Rehabilitation Engineering Research Institute, Incheon, Republic of Korea
3 shared publicationsJung Sun Kang
Rehabilitation Engineering Research Institute, Incheon, Republic of Korea
3 shared publicationsBok Man Lim
Wirobotics Incorporation, Yongin, Republic of Korea
2 shared publicationsByung June Choi
Wirobotics Incorporation, Yongin, Republic of Korea
2 shared publicationsEung-Pyo Hong
Rehabilitation Engineering Research Institute, Incheon, Republic of Korea
2 shared publications- Gyoo-Suk Kim
Rehabilitation Engineering Research Institute, Incheon 21417, Korea
2 shared publications
Latest Publications
- 30 July 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (10) , 4287-4303
Gait Simulation Method Using the Damping Characteristics of a Linear Hydraulic Cylinder for Microprocessor-Controlled Knees
- 30 July 2026
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 27 (10) , 4287-4303
Gait Simulation Method Using the Damping Characteristics of a Linear Hydraulic Cylinder for Microprocessor-Controlled Knees
- Open Access
- 14 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (12) , 6703
A Comparative Study of the Effects of Augmented Reality Application on Movement Accuracy and Subjective Satisfaction in Rehabilitation Training for Individuals with Lower Limb Amputations
This study investigated the efficacy of Augmented Reality (AR) in the rehabilitation of lower limb amputees by comparing movement accuracy and subjective satisfaction with and without AR. Ten individuals with unilateral lower limb amputations participated. Joint range of motion during exercises was measured using a 3D motion capture system. Subjective satisfaction was assessed via a 5-point Likert scale. Movement accuracy was evaluated by analyzing changes and variability (standard deviation) in joint angles across eight selected movements. Results showed that AR feedback significantly increased average joint angles in specific movements: standing arm raise to the side, standing trunk lateral flexion, and standing knee flexion to maximum height. Furthermore, AR feedback led to a significant reduction in the standard deviation of joint angles for most exercises, indicating improved movement consistency. Subjective satisfaction scores for interest, motivation, exercise effectiveness, movement accuracy, and overall satisfaction were significantly higher with AR.
- 14 June 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (12) , 6703
Open AccessA Comparative Study of the Effects of Augmented Reality Application on Movement Accuracy and Subjective Satisfaction in Rehabilitation Training for Individuals with Lower Limb Amputations
This study investigated the efficacy of Augmented Reality (AR) in the rehabilitation of lower limb amputees by comparing movement accuracy and subjective satisfaction with and without AR. Ten individuals with unilateral lower limb amputations participated. Joint range of motion during exercises was measured using a 3D motion capture system. Subjective satisfaction was assessed via a 5-point Likert scale. Movement accuracy was evaluated by analyzing changes and variability (standard deviation) in joint angles across eight selected movements. Results showed that AR feedback significantly increased average joint angles in specific movements: standing arm raise to the side, standing trunk lateral flexion, and standing knee flexion to maximum height. Furthermore, AR feedback led to a significant reduction in the standard deviation of joint angles for most exercises, indicating improved movement consistency. Subjective satisfaction scores for interest, motivation, exercise effectiveness, movement accuracy, and overall satisfaction were significantly higher with AR.
- 26 August 2024
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 26 (1) , 227-238
EMG and Usability Assessment of Adjustable Stiffness Passive Waist-Assist Exoskeletons for Construction Workers
- 26 August 2024
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 26 (1) , 227-238
EMG and Usability Assessment of Adjustable Stiffness Passive Waist-Assist Exoskeletons for Construction Workers
- 1 January 2024
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 41 (1) , 37-46
Verification of Walking Efficiency of Wearable Hip Assist Robot for Industrial Workers: A Preliminary Study
In highly mobile workplaces, wearable walking assistant robots can reduce muscle fatigue in the lower extremities of workers and increase energy efficiency. In this study, walking efficiency according to the development of an ultralight wearable hip-assist robot for industrial workers was verified. Five healthy adult males participated in this study. Their muscle fatigue and energy consumption were compared with and without the robot while walking on a flat treadmill and stairs. When walking on the treadmill while wearing the robot, muscle fatigue in the rectus femoris and gastrocnemius decreased by 90.2% and 37.7%, respectively. Oxygen uptake and energy expenditure per minute also decreased by 8.9% and 13.1%, respectively. When climbing stairs while wearing the robot, fatigue of the tibialis anterior, semitendinosus, and gastrocnemius muscles decreased by 18.2%, 33.3%, and 63.6%, respectively. Oxygen uptake and energy expenditure per minute also decreased by 3.6% and 3.7%, respectively. Although wearing a hip-assist robot could reduce muscle fatigue and use metabolic energy more efficiently, it is necessary to further increase the energy efficiency while climbing stairs. This study is intended to provide basic data to improve the performance of robots.
- 1 January 2024
- Published by Korean Society of Precision Engineering in Journal of the Korean Society for Precision Engineering
- Vol. 41 (1) , 37-46
Verification of Walking Efficiency of Wearable Hip Assist Robot for Industrial Workers: A Preliminary Study
In highly mobile workplaces, wearable walking assistant robots can reduce muscle fatigue in the lower extremities of workers and increase energy efficiency. In this study, walking efficiency according to the development of an ultralight wearable hip-assist robot for industrial workers was verified. Five healthy adult males participated in this study. Their muscle fatigue and energy consumption were compared with and without the robot while walking on a flat treadmill and stairs. When walking on the treadmill while wearing the robot, muscle fatigue in the rectus femoris and gastrocnemius decreased by 90.2% and 37.7%, respectively. Oxygen uptake and energy expenditure per minute also decreased by 8.9% and 13.1%, respectively. When climbing stairs while wearing the robot, fatigue of the tibialis anterior, semitendinosus, and gastrocnemius muscles decreased by 18.2%, 33.3%, and 63.6%, respectively. Oxygen uptake and energy expenditure per minute also decreased by 3.6% and 3.7%, respectively. Although wearing a hip-assist robot could reduce muscle fatigue and use metabolic energy more efficiently, it is necessary to further increase the energy efficiency while climbing stairs. This study is intended to provide basic data to improve the performance of robots.
- Open Access
- 31 December 2023
- Published by Digital Contents Society in Journal of Digital Contents Society
- Vol. 24 (12) , 3013-3022
Effects of Augmented Reality-based Physical Exercise on Walking Speed and Balance Ability in Older Adults
- 31 December 2023
- Published by Digital Contents Society in Journal of Digital Contents Society
- Vol. 24 (12) , 3013-3022
Open AccessEffects of Augmented Reality-based Physical Exercise on Walking Speed and Balance Ability in Older Adults
- Open Access
- 23 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (23) , 12609
Verification of Industrial Worker Walking Efficiency with Wearable Hip Exoskeleton
In highly mobile workplaces, wearable walking-assistant devices reduce muscle fatigue in workers’ lower extremities and increase energy efficiency. In our study, we verify this following the development of an ultralight wearable hip exoskeleton for industrial workers. Ten healthy male adults participated in this study, and their muscle activity, muscle fatigue, and energy expenditure were compared with and without a device while walking on a treadmill and going up stairs. While walking on a treadmill with the assistive device, muscle fatigue in the gastrocnemius decreased by 79.5%, and oxygen uptake and energy expenditure per minute decreased by 7.9% and 7.4%, respectively. While climbing stairs with the assistive device, muscle fatigue of the tibialis anterior decreased by 83.5%, average muscle activity of the rectus femoris, semitendinosus, and gastrocnemius muscles decreased significantly, and oxygen uptake and energy expenditure decreased by 14% and 12.9% per minute, respectively. We confirm that an ultralight wearable hip exoskeleton helps the wearer reduce lower-limb muscle fatigue and use metabolic energy more efficiently. The results of this study are intended as basic data to expand the use of ultralight wearable hip exoskeletons at industrial sites and to improve device performance.
- 23 November 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (23) , 12609
Open AccessVerification of Industrial Worker Walking Efficiency with Wearable Hip Exoskeleton
In highly mobile workplaces, wearable walking-assistant devices reduce muscle fatigue in workers’ lower extremities and increase energy efficiency. In our study, we verify this following the development of an ultralight wearable hip exoskeleton for industrial workers. Ten healthy male adults participated in this study, and their muscle activity, muscle fatigue, and energy expenditure were compared with and without a device while walking on a treadmill and going up stairs. While walking on a treadmill with the assistive device, muscle fatigue in the gastrocnemius decreased by 79.5%, and oxygen uptake and energy expenditure per minute decreased by 7.9% and 7.4%, respectively. While climbing stairs with the assistive device, muscle fatigue of the tibialis anterior decreased by 83.5%, average muscle activity of the rectus femoris, semitendinosus, and gastrocnemius muscles decreased significantly, and oxygen uptake and energy expenditure decreased by 14% and 12.9% per minute, respectively. We confirm that an ultralight wearable hip exoskeleton helps the wearer reduce lower-limb muscle fatigue and use metabolic energy more efficiently. The results of this study are intended as basic data to expand the use of ultralight wearable hip exoskeletons at industrial sites and to improve device performance.
- Open Access
- 29 December 2022
- Published by MDPI AG in Healthcare
- Vol. 11 (1) , 106
Development of a Digital Healthcare Management System for Lower-Extremity Amputees: A Pilot Study
The research, which was designed as a “pre- and post-single group” study, included patients with lower-limb amputation and aimed to evaluate the effectiveness of self-directed physical-strength training and cardiovascular exercise using a novel digital healthcare management service three times a week for 12 weeks. Muscle strength, thigh circumference, lipid profile and glycated hemoglobin levels, pulmonary function, quality of life, and physical activity level were evaluated before and after the intervention, while satisfaction was measured after the study. Among the 14 included patients, the proportion of adherence to the physical-strength training and physical-strengthening activity were 85.2% and 75.8%, respectively. The level of satisfaction with the digital healthcare management system was high. Significant changes were observed in the muscle-strength tests (dominant grip power and muscle strength of knee flexion and extension of the intact side), thigh circumference, and glycated hemoglobin levels. Further, the quality-of-life score showed improvement, although without significant differences. Individualized exercise management using the novel digital healthcare management system for lower-limb amputees could induce interest in self-care and promote physical activity and healthy behavior. Through this effect, we can expect a reduction in the incidence of cardiovascular diseases, diabetes mellitus, dyslipidemia, and severe injuries from falling.
- 29 December 2022
- Published by MDPI AG in Healthcare
- Vol. 11 (1) , 106
Open AccessDevelopment of a Digital Healthcare Management System for Lower-Extremity Amputees: A Pilot Study
The research, which was designed as a “pre- and post-single group” study, included patients with lower-limb amputation and aimed to evaluate the effectiveness of self-directed physical-strength training and cardiovascular exercise using a novel digital healthcare management service three times a week for 12 weeks. Muscle strength, thigh circumference, lipid profile and glycated hemoglobin levels, pulmonary function, quality of life, and physical activity level were evaluated before and after the intervention, while satisfaction was measured after the study. Among the 14 included patients, the proportion of adherence to the physical-strength training and physical-strengthening activity were 85.2% and 75.8%, respectively. The level of satisfaction with the digital healthcare management system was high. Significant changes were observed in the muscle-strength tests (dominant grip power and muscle strength of knee flexion and extension of the intact side), thigh circumference, and glycated hemoglobin levels. Further, the quality-of-life score showed improvement, although without significant differences. Individualized exercise management using the novel digital healthcare management system for lower-limb amputees could induce interest in self-care and promote physical activity and healthy behavior. Through this effect, we can expect a reduction in the incidence of cardiovascular diseases, diabetes mellitus, dyslipidemia, and severe injuries from falling.
- 9 February 2022
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 23 (3) , 361-373
Changes in Spatiotemporal Parameters and Lower Limb Coordination During Prosthetic Gait Training in Unilateral Transfemoral Amputees
- 9 February 2022
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 23 (3) , 361-373
Changes in Spatiotemporal Parameters and Lower Limb Coordination During Prosthetic Gait Training in Unilateral Transfemoral Amputees
- Open Access
- 12 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10651
Analysis of Body-Slip and Buttock Pressure Characteristics during Operation of a Double-Sliding Reclining Wheelchair in Patients with Spinal Cord Injury
To minimize body collapse due to repetitive reclining and repositioning when using a reclining wheelchair, reclining wheelchairs with a sliding backrest function have been developed. This study compared the differences in body-slip and buttock pressure according to the presence or absence of the sliding function of the backrest during reclining and repositioning motions in 10 patients with spinal cord injury. When reclining from 100° to 130°, backrest sliding and total body-slip in the double-sliding wheelchair were significantly decreased by 21.4 mm and 16.4 mm, respectively, compared to a non-sliding wheelchair, and the peak pressure on the ischial tuberosity was significantly decreased by 8.7 kPa. Upon comparison of the buttock pressure between the initial upright position before reclining and the return upright position after repositioning, the force and mean pressure with the double-sliding wheelchair were significantly reduced compared with those with the non-sliding wheelchair. It was confirmed that the double-sliding system improved body-slip and buttock pressure more effectively than the non-sliding system. This study’s results are expected to provide the basic data necessary for the prescription and selection of wheelchairs in clinical practice and to be utilized in the development of related devices.
- 12 November 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10651
Open AccessAnalysis of Body-Slip and Buttock Pressure Characteristics during Operation of a Double-Sliding Reclining Wheelchair in Patients with Spinal Cord Injury
To minimize body collapse due to repetitive reclining and repositioning when using a reclining wheelchair, reclining wheelchairs with a sliding backrest function have been developed. This study compared the differences in body-slip and buttock pressure according to the presence or absence of the sliding function of the backrest during reclining and repositioning motions in 10 patients with spinal cord injury. When reclining from 100° to 130°, backrest sliding and total body-slip in the double-sliding wheelchair were significantly decreased by 21.4 mm and 16.4 mm, respectively, compared to a non-sliding wheelchair, and the peak pressure on the ischial tuberosity was significantly decreased by 8.7 kPa. Upon comparison of the buttock pressure between the initial upright position before reclining and the return upright position after repositioning, the force and mean pressure with the double-sliding wheelchair were significantly reduced compared with those with the non-sliding wheelchair. It was confirmed that the double-sliding system improved body-slip and buttock pressure more effectively than the non-sliding system. This study’s results are expected to provide the basic data necessary for the prescription and selection of wheelchairs in clinical practice and to be utilized in the development of related devices.
- Open Access
- 30 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (19) , 9122
Intramuscular Properties of Resting Lumbar Muscles in Patients with Unilateral Lower Limb Amputation
Lower limb amputees (LLAs) have a high incidence of low back pain (LBP), and identifying the potential risk factors in this group is key for LBP prevention. This study analyzed the intramuscular properties of the resting lumbar muscle in thirteen unilateral LLAs and age-matched controls to predict the onset of LBP. To measure the lumbar intramuscular properties, resting erector spinae muscles located in the upper and lower lumbar regions were examined using a handheld myotonometer. The dynamic stiffness, oscillation frequency, and logarithmic decrement were measured. In our results, the stiffness and frequency of the upper lumbar region were greater in the amputee group than in the control, whereas the decrement did not differ between the two groups. Additionally, the measured values in the lower lumbar region showed no significant difference. Within each group, all three factors increased at the upper lumbar region. In the LLAs, the frequency and stiffness values of the upper lumbar on the non-amputated side were significantly higher than those on the amputated side. These results indicate that the upper lumbar muscles of the amputees were less flexible than that of the control. This study can help in providing therapeutic strategies treating LBP in amputees.
- 30 September 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (19) , 9122
Open AccessIntramuscular Properties of Resting Lumbar Muscles in Patients with Unilateral Lower Limb Amputation
Lower limb amputees (LLAs) have a high incidence of low back pain (LBP), and identifying the potential risk factors in this group is key for LBP prevention. This study analyzed the intramuscular properties of the resting lumbar muscle in thirteen unilateral LLAs and age-matched controls to predict the onset of LBP. To measure the lumbar intramuscular properties, resting erector spinae muscles located in the upper and lower lumbar regions were examined using a handheld myotonometer. The dynamic stiffness, oscillation frequency, and logarithmic decrement were measured. In our results, the stiffness and frequency of the upper lumbar region were greater in the amputee group than in the control, whereas the decrement did not differ between the two groups. Additionally, the measured values in the lower lumbar region showed no significant difference. Within each group, all three factors increased at the upper lumbar region. In the LLAs, the frequency and stiffness values of the upper lumbar on the non-amputated side were significantly higher than those on the amputated side. These results indicate that the upper lumbar muscles of the amputees were less flexible than that of the control. This study can help in providing therapeutic strategies treating LBP in amputees.