Huan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Huan Wang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Chunlin Deng
School of Materials Science and Engineering, South China University of Technology, Guangzhou, China
1 shared publication - Gang Wu
School of Materials Science and Engineering South China University of Technology Guangzhou P. R. China
1 shared publication - Hua Liao
Department of Human Anatomy, School of Basic Medical Sciences Southern Medical University Guangzhou China
1 shared publication - Jian-Rong Guo
Department of Anesthesiology, Shanghai Gongli Hospital, The Second Military Medical University, China
1 shared publication - Jiangwei Xiao
Chengdu Medical College, Chengdu, China
1 shared publication - Li-Shuang Duan
Department of Anesthesiology, Shanghai Gongli Hospital, The Second Military Medical University, China
1 shared publication
Latest Publications
- Open Access
- 28 April 2021
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 30 (4) , 387-394
The effect of different storage times on the oxygen-carrying capacity of the exosomes of red blood cells
After storing blood for a period of time, the structure and properties of the red blood cells (RBC) will change, which results in a decrease in the oxygen-carrying capacity, and further has a certain impact on their exosomes. Effective oxygen uptake (Q), P50, 2,3-DPG, and Na+-K+-ATP of RBC after different storage times were detected. Electron microscopy was used to observe the morphology of RBC and the characteristics of secreting exosomes. Western blot was used to detect the expression of phenotypes CD63 and CD81 of exosomes, and the expression of mitochondrial riboprotein MRPS35 of exosomes was also detected to explore the mechanism of decreased function of RBC with the extension of preservation time. After the RBC suspension was prepared, the effective oxygen-carrying capacity (Q) and P50, as well as 2,3-DPG and Na+-K+-ATP were prepared. This was followed by morphology observation of erythrocyte exosomes using transmission electron microscope (TEM), and by western blot analysis of exosome phenotypes CD63 and CD81. Erythrocytes secrete exosomes, which results in abnormal expression of related proteins in mitochondria. This leads to increased ROS production, mitochondrial apoptosis and, finally, changes in or damage to erythrocytes. Changes in the rheological properties and oxygen-carrying functions of erythrocytes during preservation are all observable manifestations, underlying which lie mechanisms of damage at the molecular level of erythrocytes. Erythrocytes secrete exosomes, which results in abnormal expression of related proteins in mitochondria, increasing ROS production, mitochondrial apoptosis and, finally, changes or damage to erythrocytes.
- 28 April 2021
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 30 (4) , 387-394
Open AccessThe effect of different storage times on the oxygen-carrying capacity of the exosomes of red blood cells
After storing blood for a period of time, the structure and properties of the red blood cells (RBC) will change, which results in a decrease in the oxygen-carrying capacity, and further has a certain impact on their exosomes. Effective oxygen uptake (Q), P50, 2,3-DPG, and Na+-K+-ATP of RBC after different storage times were detected. Electron microscopy was used to observe the morphology of RBC and the characteristics of secreting exosomes. Western blot was used to detect the expression of phenotypes CD63 and CD81 of exosomes, and the expression of mitochondrial riboprotein MRPS35 of exosomes was also detected to explore the mechanism of decreased function of RBC with the extension of preservation time. After the RBC suspension was prepared, the effective oxygen-carrying capacity (Q) and P50, as well as 2,3-DPG and Na+-K+-ATP were prepared. This was followed by morphology observation of erythrocyte exosomes using transmission electron microscope (TEM), and by western blot analysis of exosome phenotypes CD63 and CD81. Erythrocytes secrete exosomes, which results in abnormal expression of related proteins in mitochondria. This leads to increased ROS production, mitochondrial apoptosis and, finally, changes in or damage to erythrocytes. Changes in the rheological properties and oxygen-carrying functions of erythrocytes during preservation are all observable manifestations, underlying which lie mechanisms of damage at the molecular level of erythrocytes. Erythrocytes secrete exosomes, which results in abnormal expression of related proteins in mitochondria, increasing ROS production, mitochondrial apoptosis and, finally, changes or damage to erythrocytes.
- 23 January 2018
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 32 (8) , 999-1010
Blocking of matrix metalloproteinases-13 responsive peptide in poly(urethane urea) for potential cartilage tissue engineering applications
The matching of scaffold degradation rate with neotissue growth is required for tissue engineering applications. Timely provision of proper spaces especially for cartilage tissue engineering plays a pivotal role in chondrocyte cluster formation. In this study, poly(urethane urea) was synthesized using conventional two-stage method by extending the isocyanate group terminated prepolymers with different amounts of GPLGLWARK peptide, which responses the degrading induced by matrix metalloproteinase 13, the main proteinase for cartilage matrix degradation. The Fourier transform infrared spectrometer with the attenuated total reflection and 1H nuclear magnetic resonance spectra revealed that the peptides were introduced to poly(urethane urea) according to the characteristic absorption bands of the peptide and the newly formed urea bonds. The ultraviolet–visible spectroscopy spectra showed that the weight percentages of the peptide in the three poly(urethane urea) were 25%, 32%, and 35%. Atomic force microscopy images revealed that phase separation occurred in all poly(urethane urea) samples and became increasingly apparent with increasing amount of peptides introduced. Mechanical tests showed that the poly(urethane urea) strength increased with increasing amount of peptides in poly(urethane urea). Poly(urethane urea) proteolysis in matrix metalloproteinase 13 solution was more rapid than hydrolysis in aqueous buffer, and proteolysis rate was dependent on the amount of peptides in poly(urethane urea). Cell proliferation on the material surface in vitro displayed nontoxicity for all synthesized poly(urethane urea). In vivo subcutaneous implantation evaluation revealed the presence of local foreign body reactions triggered by poly(urethane urea) but was not due to peptide in poly(urethane urea). Moreover, the synthesized poly(urethane urea) with significant phase separation did not degrade under the matrix metalloproteinase 13 free subcutaneous environment, but poly(urethane urea) with minimal phase separation was degraded by attacking of the enzymes adsorbed on the hydrophobic surface through non-specific adsorption.
- 23 January 2018
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 32 (8) , 999-1010
Blocking of matrix metalloproteinases-13 responsive peptide in poly(urethane urea) for potential cartilage tissue engineering applications
The matching of scaffold degradation rate with neotissue growth is required for tissue engineering applications. Timely provision of proper spaces especially for cartilage tissue engineering plays a pivotal role in chondrocyte cluster formation. In this study, poly(urethane urea) was synthesized using conventional two-stage method by extending the isocyanate group terminated prepolymers with different amounts of GPLGLWARK peptide, which responses the degrading induced by matrix metalloproteinase 13, the main proteinase for cartilage matrix degradation. The Fourier transform infrared spectrometer with the attenuated total reflection and 1H nuclear magnetic resonance spectra revealed that the peptides were introduced to poly(urethane urea) according to the characteristic absorption bands of the peptide and the newly formed urea bonds. The ultraviolet–visible spectroscopy spectra showed that the weight percentages of the peptide in the three poly(urethane urea) were 25%, 32%, and 35%. Atomic force microscopy images revealed that phase separation occurred in all poly(urethane urea) samples and became increasingly apparent with increasing amount of peptides introduced. Mechanical tests showed that the poly(urethane urea) strength increased with increasing amount of peptides in poly(urethane urea). Poly(urethane urea) proteolysis in matrix metalloproteinase 13 solution was more rapid than hydrolysis in aqueous buffer, and proteolysis rate was dependent on the amount of peptides in poly(urethane urea). Cell proliferation on the material surface in vitro displayed nontoxicity for all synthesized poly(urethane urea). In vivo subcutaneous implantation evaluation revealed the presence of local foreign body reactions triggered by poly(urethane urea) but was not due to peptide in poly(urethane urea). Moreover, the synthesized poly(urethane urea) with significant phase separation did not degrade under the matrix metalloproteinase 13 free subcutaneous environment, but poly(urethane urea) with minimal phase separation was degraded by attacking of the enzymes adsorbed on the hydrophobic surface through non-specific adsorption.