JWJin Wang

Jin Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jin Wang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • MEASUREMENT OF LIQUID SURFACE TENSION AND AIR VISCOSITY COEFFICIENT USING DYNAMIC BUBBLE METHOD

    by Qinglin Li, Jin Wang, Zhichao Deng, Yanjing Ding, Chao Zhang, Ke Liu, Zijun Wei

    The paper presents a device that measures the surface tension coefficient of bubble solution and the viscosity coefficient of air using the dynamic bubble method. The device captures the changes in radius and the difference in internal and external pressures during the inflation process of soap bubbles, determining the surface tension coefficient of the bubble solution through data fitting. It employs the Laplace equation and Poiseuille equation to make reasonable predictions about the changes in radius during bubble contraction. The viscosity coefficient of air can be analyzed from the data of the bubble contraction process. The device integrates the measurement of liquid surface tension coefficient and air viscosity coefficient, which can enrich and enhance students' knowledge and experimental skills. The device is also adjustable for exploration and expansion, making it suitable for college physics experiment teaching.

  • DEVELOPMENT ANALYSIS OF PHYSICS ACADEMIC COMPETITION BASED ON MAPPING KNOWLEDGE

    by Jiahao Dong, Jin Wang, Chuanyong Li, Yongfa Kong, Chongpei Pan

    The International Young Physicists' Tournament, the localized China Undergraduate Physics Tournament, the China Young Physicists' Tournament and a series of physics academic competitions in universities in various regions are playing an increasingly important role in basic physics teaching. Based on CiteSpace visualization software, this paper analyzes the literatures extracted from CNKI Chinese database, WOS database and Scoups database with the theme of PT series physics academic competitions, and displays the chronological distribution, the co-occurrence map of keyword, time zone map, salient words and the co-occurrence map of institution of the literatures in the form of econometric analysis and knowledge map. Combined with the development and modernization of contemporary sports events, the application of mapping knowledge in reflecting the situation of sports events, physical problem research and case analysis and basic physics experiment teaching is explored.

  • Open Access

    HOME EXPERIMENT—COIN BOUNCING

    by Jiahao Dong, Jin Wang, Wenhua Li, Xiaoqing Wen, Wangwei Hui

    In this paper, the smart phone was used to study the acoustic frequency and resonance mode of coin bouncing in home environment. Firstly, according to the vibration equation of the circular plate, the expression of the natural vibration frequency of the coin is given. Then combined with specific boundary conditions, the natural vibration modes and corresponding frequencies of three types of coins are analyzed by finite element method. In the experiment, the acoustic frequency produced by the free vibration of different coins is measured by smart phone, and compared with the simulation results, then a reasonable error analysis is given. This home experiment scheme is rich in physical principles, simple and interesting, and easy to be popularized in basic physics experiment teaching.

  • Study on the magnetic levitation of a magnetic flea

    by Yuchen Jiang, Jin Wang, Xiaojie Wang

    We investigated the problem of ‘magnetic levitation’ originating from the 33 rd International Young Physicists’ Tournament (IYPT). The problem was first investigated by a PRL paper (Baldwin et al.) in 2018, which states that the flea of a magnetic stirrer spinning fast enough in a liquid with a high viscosity coefficient can jump from the bottom and levitate stably. The magnetic force and gravity balance periodically. This phenomenon includes several concepts: magnetic dipoles, rigid-body rotation, fluid mechanics and magnetic levitation. They are more or less unfamiliar to undergraduate students. However, the movement of the flea could be described with a concise forced vibration equation, which is familiar in textbooks. The phenomenon could be divided into two stages: synchronous movement and levitation state. The transition is the jumping of the flea. We demonstrated this process and presented several equations to build this physical model. The progression of the phenomenon is due to the increase in the drive magnet angular velocity called the drive velocity. We verified our theory by simulation and experiments. Several parameters are experimentally verified to influence the phenomenon. We also discussed the origin of dynamic stabilization, which would be slightly complicated but worthy for students. In short, we introduce an interesting problem originating from the PRL paper that can be easily achieved under laboratory conditions. We extend some content in a pedagogical way that would be helpful for students to understand the related physical concepts, such as the influence of the viscosity coefficient of the liquid on the flea’s motion, which is not discussed in the PRL paper.

  • A spatial resolution evaluation method of endoscopic optical coherence tomography system using the annular phantom

    by Ningning Huang, Zhichao Deng, Zhixiong Hu, Jianchun Mei, Shiyong Zhao, Xining Wu, Zongnan Jia, Yuyan Liu, Jin Wang, Qing Ye, et al.

    As an important biomedical imaging method, endoscopic optical coherence tomography (OCT) is necessary to check its performance regularly. The ordinary plane phantoms are only able to evaluate part of image tangent to the probe. In this research, a spatial resolution estimate method of the endoscope OCT system is proposed. The annular phantom, made by uniformly distributing golden scattered microparticles in polydimethylsiloxane (PDMS), can provide dynamic scanning imaging evaluation of endoscopic OCT system, closer to its actual working status. The point spread function analysis method is used to analyze the imaging results of the annular phantom with the endoscopic OCT system. And many scattered particles are statistically analyzed to determine the spatial resolution of the endoscope OCT system. The method is low in cost, simple and convenient. It is valuable for the development of test standards for endoscope OCT systems.


  • Study for a lab-made Moiré pattern-based thread counter

    by Yifan Liu, Jin Wang, Wenhua Li, Xiaoqing Wen

    The 32nd International Young Physicists’ Tournament (IYPT), a physics competition for students in schools, settled up a problem for the Moiré thread counter. The problem mentioned to design an overlay to measure the thread count of the fabric. In this paper, we made one kind of Moiré pattern-based thread counter by printing the designed overlay on the plastic paper. As a contrast, we also constructed a self-made CCD camera assisted imaging system and studied the thread count. We used a 1951 USAF resolution test chart and MATLAB software for imaging analysis. Ten kinds of simple cloth were prepared, and their thread count measured. The results and the accuracy of the two methods were discussed.


  • Open Access

    Extended Depth-of-Field of a Miniature Optical Endoscope Using Wavefront Coding

    by Lei Yang, Meng Chen, Jin Wang, Meng Zhu, Tong Yang, Shimin Zhu, Hongbo Xie

    Endoscopic imaging is an indispensable tool for visual inspection of surfaces in hard-to-access places. The conventional optical endoscope only enables imaging the regions that lie close to the focal plane, and therefore improving the depth of field (DOF) of an endoscopic system has recently attracted much attention. Here, we propose and demonstrate a simple, cost-effective, and easily available industrial endoscopic system, which is composed of a rigid tube and group of optical lenses. The outer diameter of the designed endoscopic modality presented in this article is 3 mm. By employing the wavefront coding technique, the DOF of newly-designed endoscope was extended to 2.7 mm in the proof-of-concept experiment, which is an increase of almost 10 times compared to the initial counterpart.