Xiaoxiao Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiaoxiao Yu has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Yiwei Wu
Hubei Collaborative Innovation Center for Rare Metal Chemistry, Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, China
6 shared publicationsHan Jiang
Hubei Collaborative Innovation Center for Rare Metal Chemistry, Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering
3 shared publicationsHan Wang
Wuhan Customs District of China, Wuhan, 430020, China
3 shared publicationsBin Zhang
Hubei Collaborative Innovation Center for Rare Metal Chemistry, Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, China
2 shared publications- Guosong Lai
Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi, China
2 shared publications Meng Zhang
Hubei Collaborative Innovation Center for Rare Metal Chemistry, Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi, 435002, China
2 shared publications
Latest Publications
- 7 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
A “Signal Relay” Mode Triggered by Bimetallic Synergistic Enhancement in an MOF-Based Multiemission Fluorescence Sensing/Adsorption Platform for Broad-Concentration-Range Tetracycline Antibiotics Visual Detection
The widespread misuse of tetracycline antibiotics (TCs) and their persistent low-concentration residues in animal-derived foods pose critical threats to human health, while existing analytical methods lack the capability for continuous therapeutic drug monitoring. Herein, a multiemission MOF-on-MOF fluorescence sensing platform codoped with Eu3+ and Zn2+ was engineered via epitaxial growth for simultaneous adsorption and detection of tetracycline, oxytetracycline, chlortetracycline, and doxycycline. By leveraging the differential coordination affinities of Eu3+ and Zn2+ toward TCs, a "signal relay" response mechanism was innovatively designed: At trace concentrations (0.05-6 μM), TCs preferentially bind to Eu3+ sites via the antenna effect, generating linearly enhanced fluorescence at 616 nm with an ultralow detection limit of 9 nM (22-fold below EU MRLs). Upon Eu3+ site saturation (>6 μM), Zn2+ domains initiate coordination-induced aggregation of TCs, triggering a second-stage fluorescence enhancement at 520 nm that extends the dynamic range to 40 μM. This platform was successfully applied to detect TCs across wide concentration ranges in environmental water, animal-derived foods, and veterinary drugs. A novel dual-metal-doped MOF-on-MOF integrates broad detection range, fast adsorption kinetics, better stability, and multiscenario applicability, while multiemission wavelengths enhance the sensitivity of fluorescence color changes, better meeting practical needs for visual detection.
- 7 August 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
A “Signal Relay” Mode Triggered by Bimetallic Synergistic Enhancement in an MOF-Based Multiemission Fluorescence Sensing/Adsorption Platform for Broad-Concentration-Range Tetracycline Antibiotics Visual Detection
The widespread misuse of tetracycline antibiotics (TCs) and their persistent low-concentration residues in animal-derived foods pose critical threats to human health, while existing analytical methods lack the capability for continuous therapeutic drug monitoring. Herein, a multiemission MOF-on-MOF fluorescence sensing platform codoped with Eu3+ and Zn2+ was engineered via epitaxial growth for simultaneous adsorption and detection of tetracycline, oxytetracycline, chlortetracycline, and doxycycline. By leveraging the differential coordination affinities of Eu3+ and Zn2+ toward TCs, a "signal relay" response mechanism was innovatively designed: At trace concentrations (0.05-6 μM), TCs preferentially bind to Eu3+ sites via the antenna effect, generating linearly enhanced fluorescence at 616 nm with an ultralow detection limit of 9 nM (22-fold below EU MRLs). Upon Eu3+ site saturation (>6 μM), Zn2+ domains initiate coordination-induced aggregation of TCs, triggering a second-stage fluorescence enhancement at 520 nm that extends the dynamic range to 40 μM. This platform was successfully applied to detect TCs across wide concentration ranges in environmental water, animal-derived foods, and veterinary drugs. A novel dual-metal-doped MOF-on-MOF integrates broad detection range, fast adsorption kinetics, better stability, and multiscenario applicability, while multiemission wavelengths enhance the sensitivity of fluorescence color changes, better meeting practical needs for visual detection.
- 4 April 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (14) , 3191-3200
Dual DNA recycling amplification-assisted CRISPR/Cas12a cleavage for dual-channel ratiometric fluorescence biosensing of kanamycin antibiotic
Fluorescence biosensors hold significant importance for testing antibiotic residues which seriously endanger public health. However, how to adopt appropriate strategies to address the false result disadvantage involved in traditional single-channel biosensors is still a great challenge. Meanwhile, too much attention focused on designing signal amplification strategies of biosensors unavoidably decreases their detection efficiency. Herein, we combined the designed dual DNA recycling amplification strategy with CRISPR/Cas12a-mediated dual-channel signal output mode to successfully develop a novel ratiometric fluorescence biosensor for testing kanamycin (Kana) residues in complex sample matrices. The first recycling was formed from an exonuclease-assisted aptamer recognition reaction, which also triggered another cascade DNA recycling to amplify the release of the Cas12a activator. With the non-discrimination cleavage of Cas12a to cause reverse fluorescence changes of copper nanoclusters and an AMAC-labeled signal DNA, the ratiometric signal transduction strategy was constructed. Under optimal conditions, this biosensor could be applied for ultrasensitive testing of Kana antibiotics in a five-order of magnitude wide linear range with a low detection limit of 17.2 fg mL−1. Benefiting from the self-correction function of the ratiometric signal transduction mode, it showed promising practicality in lake water and milk samples with the relative error less than 4.9% to the standard ELISA results. Besides CRISPR/Cas12a-based fluorescence output efficiency improvement, this biosensor also excluded the complicated manipulations and expensive instruments required in traditional methods. Therefore, it provides a good choice for expanding the application of fluorescence biosensing technology for practical analysis application. Graphical Abstract
- 4 April 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (14) , 3191-3200
Dual DNA recycling amplification-assisted CRISPR/Cas12a cleavage for dual-channel ratiometric fluorescence biosensing of kanamycin antibiotic
Fluorescence biosensors hold significant importance for testing antibiotic residues which seriously endanger public health. However, how to adopt appropriate strategies to address the false result disadvantage involved in traditional single-channel biosensors is still a great challenge. Meanwhile, too much attention focused on designing signal amplification strategies of biosensors unavoidably decreases their detection efficiency. Herein, we combined the designed dual DNA recycling amplification strategy with CRISPR/Cas12a-mediated dual-channel signal output mode to successfully develop a novel ratiometric fluorescence biosensor for testing kanamycin (Kana) residues in complex sample matrices. The first recycling was formed from an exonuclease-assisted aptamer recognition reaction, which also triggered another cascade DNA recycling to amplify the release of the Cas12a activator. With the non-discrimination cleavage of Cas12a to cause reverse fluorescence changes of copper nanoclusters and an AMAC-labeled signal DNA, the ratiometric signal transduction strategy was constructed. Under optimal conditions, this biosensor could be applied for ultrasensitive testing of Kana antibiotics in a five-order of magnitude wide linear range with a low detection limit of 17.2 fg mL−1. Benefiting from the self-correction function of the ratiometric signal transduction mode, it showed promising practicality in lake water and milk samples with the relative error less than 4.9% to the standard ELISA results. Besides CRISPR/Cas12a-based fluorescence output efficiency improvement, this biosensor also excluded the complicated manipulations and expensive instruments required in traditional methods. Therefore, it provides a good choice for expanding the application of fluorescence biosensing technology for practical analysis application. Graphical Abstract
- 3 December 2024
- Published by Elsevier in Food Chemistry
- Vol. 467, 142324
Preparation of waste toner-derived magnetic adsorbent for analysis of lead in aqueous and oil-based foods
- 3 December 2024
- Published by Elsevier in Food Chemistry
- Vol. 467, 142324
Preparation of waste toner-derived magnetic adsorbent for analysis of lead in aqueous and oil-based foods
- 10 April 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 412, 135797
Hyperbranched RCA-mediated construction of a dendritic DNA nanostructure for ratiometric fluorescence biosensing
- 10 April 2024
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 412, 135797
Hyperbranched RCA-mediated construction of a dendritic DNA nanostructure for ratiometric fluorescence biosensing
- 2 February 2024
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 235, 113774
Visual detection of H2O2 and glucose by HBcAb-HRP fluorescence-enhanced CdTe QDs/CDs ratiometric fluorescence sensing platform
- 2 February 2024
- Published by Elsevier in Colloids and Surfaces B: Biointerfaces
- Vol. 235, 113774
Visual detection of H2O2 and glucose by HBcAb-HRP fluorescence-enhanced CdTe QDs/CDs ratiometric fluorescence sensing platform
- 10 November 2023
- Published by Atomic Spectroscopy Press Limited in Atomic Spectroscopy
- Vol. 44 (04) , 227-235
Nitrogen-oxygen Co-doped Magnetic Micro-carbon Adsorbent Derived from Waste Toner Coupled with GFAAS for the Analysis of Trace Lead in Environmental and Biological Samples
- 10 November 2023
- Published by Atomic Spectroscopy Press Limited in Atomic Spectroscopy
- Vol. 44 (04) , 227-235
Nitrogen-oxygen Co-doped Magnetic Micro-carbon Adsorbent Derived from Waste Toner Coupled with GFAAS for the Analysis of Trace Lead in Environmental and Biological Samples
- 17 February 2023
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 25 (3) , 1-12
Facile one-pot preparation of AgIn5S8/MoS2 composite for selective adsorption of methylene blue from aqueous solution
- 17 February 2023
- Published by Springer Nature in Journal of Nanoparticle Research
- Vol. 25 (3) , 1-12
Facile one-pot preparation of AgIn5S8/MoS2 composite for selective adsorption of methylene blue from aqueous solution
- 19 January 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (7) , 2409-2418
Waste toner-derived micro-materials as low-cost magnetic solid-phase extraction adsorbent for the analysis of trace Pb in environmental and biological samples
Lead (Pb) is a toxic heavy metal and is commonly used in industrial applications. Thus, Pb poisoning is a concerning public health issue worldwide. The amounts of lead in natural water, urine, and blood can serve as significant indicators for monitoring the exposure of Pb poisoning. Waste toner has the characteristics of both “waste” and “resource,” as it is a “resource in the wrong place.” Here, a low-cost carboxylate-functionalized magnetic adsorbent was first synthesized from waste toner by a simple thermal treatment and served as a novel adsorbent with a flexible multidentate O-donor for pre-concentration of trace Pb. The characterization, adsorption behavior, and various factors of adsorption and desorption were adequately optimized, and prior to graphite furnace atomic absorption spectrometry (GFAAS) detection, a new magnetic solid-phase extraction method was proposed for the analysis of Pb in real environmental water and biological samples. The developed method exhibited a low detection limit (0.003 μg L−1), high enrichment factor (88.6-fold), good linearity (0.01–0.3 μg L−1), satisfactory precision with relative standard deviations of 7.9% (n = 7, CPb = 0.02 μg L−1), fast adsorption kinetics (5 min), and strong ability to overcome matrix interference. Validation was also performed by analyzing a certified standard reference material, and the method was successfully applied to real tap water, lake water, human urine, and human blood serum with satisfactory recoveries of 92.6–109%. Graphical abstract
- 19 January 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (7) , 2409-2418
Waste toner-derived micro-materials as low-cost magnetic solid-phase extraction adsorbent for the analysis of trace Pb in environmental and biological samples
Lead (Pb) is a toxic heavy metal and is commonly used in industrial applications. Thus, Pb poisoning is a concerning public health issue worldwide. The amounts of lead in natural water, urine, and blood can serve as significant indicators for monitoring the exposure of Pb poisoning. Waste toner has the characteristics of both “waste” and “resource,” as it is a “resource in the wrong place.” Here, a low-cost carboxylate-functionalized magnetic adsorbent was first synthesized from waste toner by a simple thermal treatment and served as a novel adsorbent with a flexible multidentate O-donor for pre-concentration of trace Pb. The characterization, adsorption behavior, and various factors of adsorption and desorption were adequately optimized, and prior to graphite furnace atomic absorption spectrometry (GFAAS) detection, a new magnetic solid-phase extraction method was proposed for the analysis of Pb in real environmental water and biological samples. The developed method exhibited a low detection limit (0.003 μg L−1), high enrichment factor (88.6-fold), good linearity (0.01–0.3 μg L−1), satisfactory precision with relative standard deviations of 7.9% (n = 7, CPb = 0.02 μg L−1), fast adsorption kinetics (5 min), and strong ability to overcome matrix interference. Validation was also performed by analyzing a certified standard reference material, and the method was successfully applied to real tap water, lake water, human urine, and human blood serum with satisfactory recoveries of 92.6–109%. Graphical abstract