Alessio Porcelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alessio Porcelli has a total of 969 co-authors. Here are the top co-authors by number of shared publications:
A. A. Harnisch
39 Dept. of Physics and Astronomy, Michigan State University, East Lansing, MI 48824, USA
12 shared publicationsA. Fritz
32 Institute of Physics, University of Mainz, Staudinger Weg 7, D-55099 Mainz, Germany
12 shared publicationsA. Ishihara
51 Dept. of Physics and The International Center for Hadron Astrophysics, Chiba University, Chiba 263-8522, Japan
12 shared publicationsA. Medina
21 Dept. of Physics and Center for Cosmology and Astro-Particle Physics, Ohio State University, Columbus, OH 43210, USA
12 shared publicationsA. Olivas
27 Dept. of Physics, University of Maryland, College Park, MD 20742, USA
12 shared publicationsA. Weindl
Karlsruhe Institute of Technology, Institute for Astroparticle Physics, D-76021 Karlsruhe, Germany
12 shared publications
Latest Publications
- 24 September 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Geometric Methods in Modern Physics
Searches for violations of the Pauli exclusion principle as a low-energy probe of quantum gravity
The Pauli exclusion principle is one of the pillars of quantum physics. In relativistic quantum field theory it is rooted in the spin–statistics connection and therefore in locality, causal structure and Poincaré covariance. These ingredients may be modified in candidate quantum-gravity scenarios, including noncommutative spacetimes and theories with deformed relativistic symmetries. This opens a low-energy experimental route to test quantum-gravity models through high-sensitivity searches for Pauli-forbidden atomic transitions. We review the conceptual basis, experimental strategy and recent results of the VIP experiments at the INFN Gran Sasso National Laboratory. The distinction between model-independent limits on anomalous X-ray emission, phenomenological limits on the conventional violation probability [Formula: see text], and model-dependent constraints on quantum-spacetime deformation scales is addressed. We discuss the role of the Messiah–Greenberg superselection rule, the complementarity of open- and closed-system searches, and recent field-theoretic developments connecting [Formula: see text]-deformed Poincaré symmetry, quon-like exchange and particle indistinguishability. Finally, we outline how the ongoing VIP-3 measurements across the periodic table, directional configurations and sidereal-time analyses can transform Pauli-principle tests from single-parameter exclusions into a differential program of quantum-gravity phenomenology.
- 24 September 2026
- Published by World Scientific Pub Co Pte Ltd in International Journal of Geometric Methods in Modern Physics
Searches for violations of the Pauli exclusion principle as a low-energy probe of quantum gravity
The Pauli exclusion principle is one of the pillars of quantum physics. In relativistic quantum field theory it is rooted in the spin–statistics connection and therefore in locality, causal structure and Poincaré covariance. These ingredients may be modified in candidate quantum-gravity scenarios, including noncommutative spacetimes and theories with deformed relativistic symmetries. This opens a low-energy experimental route to test quantum-gravity models through high-sensitivity searches for Pauli-forbidden atomic transitions. We review the conceptual basis, experimental strategy and recent results of the VIP experiments at the INFN Gran Sasso National Laboratory. The distinction between model-independent limits on anomalous X-ray emission, phenomenological limits on the conventional violation probability [Formula: see text], and model-dependent constraints on quantum-spacetime deformation scales is addressed. We discuss the role of the Messiah–Greenberg superselection rule, the complementarity of open- and closed-system searches, and recent field-theoretic developments connecting [Formula: see text]-deformed Poincaré symmetry, quon-like exchange and particle indistinguishability. Finally, we outline how the ongoing VIP-3 measurements across the periodic table, directional configurations and sidereal-time analyses can transform Pauli-principle tests from single-parameter exclusions into a differential program of quantum-gravity phenomenology.
- Open Access
- 6 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
First direct determination of the pick-off contribution to the ortho-positronium decay rate
- 6 June 2026
- Published by Elsevier in Physics Letters B
- Vol. 879
Open AccessFirst direct determination of the pick-off contribution to the ortho-positronium decay rate
- Open Access
- 1 June 2026
- Published by IOP Publishing in New Journal of Physics
- Vol. 28 (6) , 064511
Experimental exclusion of a generalized Károlyházy gravity-induced decoherence model
We report new experimental constraints on the generalized version of the gravity-induced decoherence model originally proposed by Károlyházy. Using data collected by the VIP Collaboration at the INFN Gran Sasso National Laboratory with a high-purity germanium detector, we derive an improved lower bound on the spatial correlation length R K characterizing metric fluctuations in the model. We obtain a bound R K > 4.64 m (95% C.L.), which exceeds by more than an order of magnitude the previous experimental limit. When combined with the theoretical upper bound R K < 1.98 m derived from macroscopic localization requirements, our result excludes the generalized Károlyházy model. The same conclusion applies to an associated non-Markovian formulation of the continuous spontaneous localization model. Our findings significantly tighten experimental constraints on gravity-related decoherence scenarios and demonstrate the sensitivity of underground low-background experiments to foundational modifications of quantum mechanics.
- 1 June 2026
- Published by IOP Publishing in New Journal of Physics
- Vol. 28 (6) , 064511
Open AccessExperimental exclusion of a generalized Károlyházy gravity-induced decoherence model
We report new experimental constraints on the generalized version of the gravity-induced decoherence model originally proposed by Károlyházy. Using data collected by the VIP Collaboration at the INFN Gran Sasso National Laboratory with a high-purity germanium detector, we derive an improved lower bound on the spatial correlation length R K characterizing metric fluctuations in the model. We obtain a bound R K > 4.64 m (95% C.L.), which exceeds by more than an order of magnitude the previous experimental limit. When combined with the theoretical upper bound R K < 1.98 m derived from macroscopic localization requirements, our result excludes the generalized Károlyházy model. The same conclusion applies to an associated non-Markovian formulation of the continuous spontaneous localization model. Our findings significantly tighten experimental constraints on gravity-related decoherence scenarios and demonstrate the sensitivity of underground low-background experiments to foundational modifications of quantum mechanics.
- Open Access
- 13 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (7) , 075026
Monte Carlo-based scatter correction for the plastic-based modular PET scanner J-PET
Objective. This work presents and evaluates a Monte Carlo (MC) -based scatter correction (SC) method developed for the Jagiellonian positron emission tomography (J-PET) scanner, a modular PET system based on plastic scintillators. Approach. The algorithm employs SimSET-based simulations integrated into a time-of-flight ordered-subsets expectation maximization reconstruction framework to estimate scatter contributions. Phantom studies using the NEMA image quality (IQ) phantom and a proof-of-principle human subject scan with the J-PET scanner were analyzed. To accelerate computation, lutetium–yttrium oxyorthosilicate (LYSO) crystals were also assessed in simulations as a surrogate for the native plastic material BC-404. Main results. In phantom experiments, SC improved contrast recovery coefficients by over 20% and reduced background variability by 8.5%, without introducing significant noise. Residual activity in cold regions was also considerably reduced. Substituting LYSO in the simulations decreased runtime by nearly one order of magnitude, while maintaining deviations below 6% in IQ metrics compared to BC-404. Human subject data demonstrated qualitatively reduced residual scatter and improved organ delineation. Quantitative comparison with the commercial PET/CT scanner by General Electric HealthCare (GE) discovery MI Gen 2 showed consistent activity concentration ratios across organs, although higher noise and residual scatter between organs were observed in J-PET, which most likely originates from lower count density. Significance. The proposed MC-based SC method provides robust scatter removal for J-PET, improving quantitative performance and establishing a foundation for advanced correction and reconstruction techniques. These results bring the plastic scintillator-based J-PET scanner closer to enabling clinically relevant quantitative PET imaging.
- 13 April 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (7) , 075026
Open AccessMonte Carlo-based scatter correction for the plastic-based modular PET scanner J-PET
Objective. This work presents and evaluates a Monte Carlo (MC) -based scatter correction (SC) method developed for the Jagiellonian positron emission tomography (J-PET) scanner, a modular PET system based on plastic scintillators. Approach. The algorithm employs SimSET-based simulations integrated into a time-of-flight ordered-subsets expectation maximization reconstruction framework to estimate scatter contributions. Phantom studies using the NEMA image quality (IQ) phantom and a proof-of-principle human subject scan with the J-PET scanner were analyzed. To accelerate computation, lutetium–yttrium oxyorthosilicate (LYSO) crystals were also assessed in simulations as a surrogate for the native plastic material BC-404. Main results. In phantom experiments, SC improved contrast recovery coefficients by over 20% and reduced background variability by 8.5%, without introducing significant noise. Residual activity in cold regions was also considerably reduced. Substituting LYSO in the simulations decreased runtime by nearly one order of magnitude, while maintaining deviations below 6% in IQ metrics compared to BC-404. Human subject data demonstrated qualitatively reduced residual scatter and improved organ delineation. Quantitative comparison with the commercial PET/CT scanner by General Electric HealthCare (GE) discovery MI Gen 2 showed consistent activity concentration ratios across organs, although higher noise and residual scatter between organs were observed in J-PET, which most likely originates from lower count density. Significance. The proposed MC-based SC method provides robust scatter removal for J-PET, improving quantitative performance and establishing a foundation for advanced correction and reconstruction techniques. These results bring the plastic scintillator-based J-PET scanner closer to enabling clinically relevant quantitative PET imaging.
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01036
Machine-learning-enhanced event selection for BEGe detectors in the VIP experiment
The VIP collaboration operates a Broad-Energy Germanium (BEGe) detector at the Gran Sasso National Laboratory to measure radiation in the few-keV to 100 keV range, aiming to search for spontaneous collapse-induced radiation and atomic transitions violating the Pauli Exclusion Principle. Here, we present a machine-learning-based upgrade for the BEGe detector of an event-selection strategy aimed at improving the efficiency in detecting low-energy events down to 10 keV. The method employs a denoising autoencoder to suppress electronic and microphonic noises and reconstruct pulse shapes, followed by a convolutional neural network that classifies waveforms as normal single-site events or anomalous events. The workflow was validated on a dataset comprising more than 20,000 waveforms recorded in 2021. The classifier achieves a receiver operating characteristic (ROC) curve with an area under the curve (AUC) of 0.99 and an accuracy of 95%. Applying this procedure lowers the minimum detectable energy of the final spectrum to approximately 10 keV. It also yields a measurable enhancement in spectral quality, including an improvement of about 14% in the signal-to-background ratio and improvement of the energy resolution for the characteristic Pb and Bi gamma lines. These developments enhance the sensitivity of the BEGe detector to rare low-energy signals and provide a scalable framework for future precision tests of quantum foundations in low-background environments.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01036
Open AccessMachine-learning-enhanced event selection for BEGe detectors in the VIP experiment
The VIP collaboration operates a Broad-Energy Germanium (BEGe) detector at the Gran Sasso National Laboratory to measure radiation in the few-keV to 100 keV range, aiming to search for spontaneous collapse-induced radiation and atomic transitions violating the Pauli Exclusion Principle. Here, we present a machine-learning-based upgrade for the BEGe detector of an event-selection strategy aimed at improving the efficiency in detecting low-energy events down to 10 keV. The method employs a denoising autoencoder to suppress electronic and microphonic noises and reconstruct pulse shapes, followed by a convolutional neural network that classifies waveforms as normal single-site events or anomalous events. The workflow was validated on a dataset comprising more than 20,000 waveforms recorded in 2021. The classifier achieves a receiver operating characteristic (ROC) curve with an area under the curve (AUC) of 0.99 and an accuracy of 95%. Applying this procedure lowers the minimum detectable energy of the final spectrum to approximately 10 keV. It also yields a measurable enhancement in spectral quality, including an improvement of about 14% in the signal-to-background ratio and improvement of the energy resolution for the characteristic Pb and Bi gamma lines. These developments enhance the sensitivity of the BEGe detector to rare low-energy signals and provide a scalable framework for future precision tests of quantum foundations in low-background environments.
- Open Access
- 29 December 2025
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 148 (6) , S80
The µPPET Project: Application of J-PET for Cosmic Rays Investigation
The µPPET project aims to study the cause of the observed excess of muons on the ground in extensive air showers — the so-called muon puzzle. In particular, it tests specific hypotheses that might lead to the solution of this 15-year-long-standing puzzle. The project repurposes two J-PET scanners developed by the Jagiellonian University as a muon tracker and an air-shower detection array. To make the first measurements in summer 2026, Monte Carlo simulations were used to understand the muon calibration in the muon tracker and possible array configurations. Progress achieved on these two crucial steps is presented in this work.
- 29 December 2025
- Published by Institute of Physics, Polish Academy of Sciences in Acta Physica Polonica A
- Vol. 148 (6) , S80
Open AccessThe µPPET Project: Application of J-PET for Cosmic Rays Investigation
The µPPET project aims to study the cause of the observed excess of muons on the ground in extensive air showers — the so-called muon puzzle. In particular, it tests specific hypotheses that might lead to the solution of this 15-year-long-standing puzzle. The project repurposes two J-PET scanners developed by the Jagiellonian University as a muon tracker and an air-shower detection array. To make the first measurements in summer 2026, Monte Carlo simulations were used to understand the muon calibration in the muon tracker and possible array configurations. Progress achieved on these two crucial steps is presented in this work.
- Open Access
- 24 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 41544
Strongest constraint on the parastatistical Quon model with the VIP-2 measurements
The spin-statistics theorem leads to Pauli’s Exclusion Principle (PEP), the basis of the stability of matter and many other phenomena relevant to physics, astrophysics, cosmology, and even biology. Possible violations of the PEP (PEPV) have been searched for since its inception; they may come from various Beyond Standard Model descriptions, including Non-Commutative Quantum Gravity models and extensions of the Quantum Field Theory, which must follow the Messiah-Greenberg Super-Selection (MGSS) rule and lead to the Quon description of the spin-statistic symmetries: the parastatstics. Efforts to search for a PEPV are not new; however, they have typically measured those cases without respecting MGSS. VIP (VIolation of the Pauli exclusion principle) first and its successor VIP-2, both sited in the “Gran Sasso underground laboratory,” aimed to set the most stringent limit for the non-Paulian transition following the MGSS rule. After two years of data with VIP-2 and better modeling of the electron-atom interaction, we present the most stringent upper limit of the probability of PEP violation for this case (\(\beta ^{2}/2<2.47\times 10^{-43}\)), thus completing the state-of-the-art of all possible PEPV cases, and the consequent constraint to the Quon description: \(1+q < 4.94 \times 10^{-43}\).- 24 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 41544
Open AccessStrongest constraint on the parastatistical Quon model with the VIP-2 measurements
The spin-statistics theorem leads to Pauli’s Exclusion Principle (PEP), the basis of the stability of matter and many other phenomena relevant to physics, astrophysics, cosmology, and even biology. Possible violations of the PEP (PEPV) have been searched for since its inception; they may come from various Beyond Standard Model descriptions, including Non-Commutative Quantum Gravity models and extensions of the Quantum Field Theory, which must follow the Messiah-Greenberg Super-Selection (MGSS) rule and lead to the Quon description of the spin-statistic symmetries: the parastatstics. Efforts to search for a PEPV are not new; however, they have typically measured those cases without respecting MGSS. VIP (VIolation of the Pauli exclusion principle) first and its successor VIP-2, both sited in the “Gran Sasso underground laboratory,” aimed to set the most stringent limit for the non-Paulian transition following the MGSS rule. After two years of data with VIP-2 and better modeling of the electron-atom interaction, we present the most stringent upper limit of the probability of PEP violation for this case (\(\beta ^{2}/2<2.47\times 10^{-43}\)), thus completing the state-of-the-art of all possible PEPV cases, and the consequent constraint to the Quon description: \(1+q < 4.94 \times 10^{-43}\). - Open Access
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 593-602
First Positronium Imaging Using 44 Sc With the J-PET Scanner: A Case Study on the NEMA-Image Quality Phantom
Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the 68Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, 44Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with 44Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph–the first plastic scintillators-based PET scanner.
- 14 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 593-602
Open AccessFirst Positronium Imaging Using 44 Sc With the J-PET Scanner: A Case Study on the NEMA-Image Quality Phantom
Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the 68Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, 44Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with 44Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph–the first plastic scintillators-based PET scanner.
- Open Access
μPPET: Investigating the Muon Puzzle with J-PET Detectors
The PPET [mu()on Probe with J-PET] project aims to investigate the “Muon Puzzle” seen in cosmic ray air showers. This puzzle arises from the observation of a significantly larger number of muons on Earth’s surface than that predicted by the current theoretical models. The investigated hypothesis is based on recently observed asymmetries in the parameters for the strong interaction cross-section and trajectory of an outgoing particle due to projectile–target polarization. The measurements require detailed information about muons at the ground level, including their track and charge distributions. To achieve this, the two PET scanners developed at the Jagiellonian University in Krakow (Poland), the J-PET detectors, will be employed, taking advantage of their well-known resolution and convenient location for detecting muons that reach long depths in the atmosphere. One station will be used as a muon tracker, while the second will reconstruct the core of the air shower. In parallel, the existing hadronic interaction models will be modified and fine-tuned based on the experimental results. In this work, we present the conceptualization and preliminary designs of PPET.Open AccessμPPET: Investigating the Muon Puzzle with J-PET Detectors
The PPET [mu()on Probe with J-PET] project aims to investigate the “Muon Puzzle” seen in cosmic ray air showers. This puzzle arises from the observation of a significantly larger number of muons on Earth’s surface than that predicted by the current theoretical models. The investigated hypothesis is based on recently observed asymmetries in the parameters for the strong interaction cross-section and trajectory of an outgoing particle due to projectile–target polarization. The measurements require detailed information about muons at the ground level, including their track and charge distributions. To achieve this, the two PET scanners developed at the Jagiellonian University in Krakow (Poland), the J-PET detectors, will be employed, taking advantage of their well-known resolution and convenient location for detecting muons that reach long depths in the atmosphere. One station will be used as a muon tracker, while the second will reconstruct the core of the air shower. In parallel, the existing hadronic interaction models will be modified and fine-tuned based on the experimental results. In this work, we present the conceptualization and preliminary designs of PPET. - Open Access
- 25 April 2025
- Published by Springer Nature in Research Square
Strongest constraint on the parastatistical Quon model with the VIP-2 measurements
The spin-statistics theorem leads to Pauli’s Exclusion Principle (PEP), the basis of the stability of matter and many other phenomena relevant to physics, astrophysics, cosmology, and even biology. Possible violations of the PEP (PEPV) have been searched for since its inception; they may come from various Beyond Standard Model descriptions, including NonCommutative Quantum Gravity models and extensions of the Quantum Field Theory, which must follow the Messiah-Greenberg Super-Selection (MGSS) rule and lead to the Quon description of the spin-statistic symmetries: the parastatstics. Efforts to search for a PEPV are not new; however, they have typically measured those cases without respecting MGSS. VIP (VIolation of the Pauli exclusion principle) first and its successor VIP-2, both sited in the “Gran Sasso underground laboratory,” aimed to set the most stringent limit for the non-Paulian transition following the MGSS rule. After two years of data with VIP-2 and better modeling of the electron-atom interaction, we present the most stringent upper limit of the probability of PEP violation for this case (β 2/2 < 2.47×10−43), thus completing the state-of-the-art of all possible PEPV cases, and the consequent constraint to the Quon description: 1+q < 4.94×10−43
- 25 April 2025
- Published by Springer Nature in Research Square
Open AccessStrongest constraint on the parastatistical Quon model with the VIP-2 measurements
The spin-statistics theorem leads to Pauli’s Exclusion Principle (PEP), the basis of the stability of matter and many other phenomena relevant to physics, astrophysics, cosmology, and even biology. Possible violations of the PEP (PEPV) have been searched for since its inception; they may come from various Beyond Standard Model descriptions, including NonCommutative Quantum Gravity models and extensions of the Quantum Field Theory, which must follow the Messiah-Greenberg Super-Selection (MGSS) rule and lead to the Quon description of the spin-statistic symmetries: the parastatstics. Efforts to search for a PEPV are not new; however, they have typically measured those cases without respecting MGSS. VIP (VIolation of the Pauli exclusion principle) first and its successor VIP-2, both sited in the “Gran Sasso underground laboratory,” aimed to set the most stringent limit for the non-Paulian transition following the MGSS rule. After two years of data with VIP-2 and better modeling of the electron-atom interaction, we present the most stringent upper limit of the probability of PEP violation for this case (β 2/2 < 2.47×10−43), thus completing the state-of-the-art of all possible PEPV cases, and the consequent constraint to the Quon description: 1+q < 4.94×10−43