Keerthi Venkatesan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Keerthi Venkatesan has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Vignesh Kailasam
Department of Orthodontics and Dentofacial Orthopedics, Sri Ramachandra Dental College and Hospital, Sri Ramachandra Institute of Higher Education and Research, Chennai, India
3 shared publications Sridevi Padmanabhan
Chennai, Tamil Nadu, India
2 shared publications- Sridevi Padmanabhan
Department of Orthodontics, Sri Ramachandra Institute of Higher Education and Research, Chennai, Tamil Nadu, India
2 shared publications Vignesh Kailasam
Chennai, Tamil Nadu, India
2 shared publications- Arunachalam Sathya1 shared publication
- Davis Devasahayam
Department of Orthodontics and Dentofacial Orthopaedics, SRM Dental College, Ramapuram, Chennai, Tamilnadu, India
1 shared publication
Latest Publications
- Open Access
- 21 June 2025
- Published by Scientific Scholar in Global Journal of Medical, Pharmaceutical, and Biomedical Update
- Vol. 20 (Supplement) , 1-76
Impact of Best Practices in Education: A Multidisciplinary Data
- 21 June 2025
- Published by Scientific Scholar in Global Journal of Medical, Pharmaceutical, and Biomedical Update
- Vol. 20 (Supplement) , 1-76
Open AccessImpact of Best Practices in Education: A Multidisciplinary Data
- Open Access
- 21 June 2025
- Published by Scientific Scholar in Global Journal of Medical, Pharmaceutical, and Biomedical Update
- Vol. 20 (Supplement) , 1-76
Learning without Limits: A Case Study on Blended Learning for Ongoing Skill Development
- 21 June 2025
- Published by Scientific Scholar in Global Journal of Medical, Pharmaceutical, and Biomedical Update
- Vol. 20 (Supplement) , 1-76
Open AccessLearning without Limits: A Case Study on Blended Learning for Ongoing Skill Development
- Open Access
- 21 June 2025
- Published by Scientific Scholar in Global Journal of Medical, Pharmaceutical, and Biomedical Update
- Vol. 20 (Supplement) , 1-76
Use of Poll Everywhere as an Assessment Tool for Journal Club Discussions
- 21 June 2025
- Published by Scientific Scholar in Global Journal of Medical, Pharmaceutical, and Biomedical Update
- Vol. 20 (Supplement) , 1-76
Open AccessUse of Poll Everywhere as an Assessment Tool for Journal Club Discussions
- Open Access
- 28 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-13
Arch perimeter changes with passive self-ligating bracket system: a systematic review and meta analysis
To determine and compare arch perimeter changes obtained with and between passive self-ligating bracket systems and conventional bracket systems. A thorough search in six databases up to January 11th, 2025 was done with no restriction of date. Prospective and retrospective studies that evaluated the arch perimeter changes with and between passive self-ligating (PSL) and conventional brackets. Quality assessment was done using the ROB 2.0 and ROBINS-I tools. A standard random-effects model was used in this review for analysis. Search identified twelve studies on arch perimeter changes with and between passive self-ligating (PSL) and conventional brackets. Eight studies were included in the quantitative analysis. Qualitative analysis indicated that arch perimeter increase was achieved with both conventional and passive self-ligating systems with no significant difference between the two. Meta-analysis indicates that there was an arch perimeter increase of 2.57 mm (0.29, 4.85) in the maxilla and 1.57 mm (-0.27, 3.41) in the mandible with passive self-ligation. However, when compared with the conventional system, the difference in arch perimeter gain was 0.09 mm (mean − 1.69, SD -1.88) in the maxillary arch and − 0.5 mm (-3.47, 2.43) in the mandibular arch. The difference was not significant. Both conventional and self-ligation systems increased arch perimeter. However, the arch perimeter changes between the two bracket systems were not clinically or statistically significant. The hypothesis that self-ligating systems have a greater increase in arch perimeter is not based on evidence. Not applicable.
- 28 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-13
Open AccessArch perimeter changes with passive self-ligating bracket system: a systematic review and meta analysis
To determine and compare arch perimeter changes obtained with and between passive self-ligating bracket systems and conventional bracket systems. A thorough search in six databases up to January 11th, 2025 was done with no restriction of date. Prospective and retrospective studies that evaluated the arch perimeter changes with and between passive self-ligating (PSL) and conventional brackets. Quality assessment was done using the ROB 2.0 and ROBINS-I tools. A standard random-effects model was used in this review for analysis. Search identified twelve studies on arch perimeter changes with and between passive self-ligating (PSL) and conventional brackets. Eight studies were included in the quantitative analysis. Qualitative analysis indicated that arch perimeter increase was achieved with both conventional and passive self-ligating systems with no significant difference between the two. Meta-analysis indicates that there was an arch perimeter increase of 2.57 mm (0.29, 4.85) in the maxilla and 1.57 mm (-0.27, 3.41) in the mandible with passive self-ligation. However, when compared with the conventional system, the difference in arch perimeter gain was 0.09 mm (mean − 1.69, SD -1.88) in the maxillary arch and − 0.5 mm (-3.47, 2.43) in the mandibular arch. The difference was not significant. Both conventional and self-ligation systems increased arch perimeter. However, the arch perimeter changes between the two bracket systems were not clinically or statistically significant. The hypothesis that self-ligating systems have a greater increase in arch perimeter is not based on evidence. Not applicable.
- 10 April 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 306-333
Coefficient of efficiency and effectiveness of functional appliances in class II malocclusion treatment
Objective To evaluate the coefficient of efficiency and effectiveness of removable and fixed functional appliances in class II malocclusion treatment. Data sources Search of studies in five databases (Medline via PubMed, Cochrane library, LILACS, SCOPUS, and SciELO) that measured mandibular skeletal changes following functional therapy was conducted until 15 April 2024. Study selection All study designs including randomized and controlled clinical trials (RCT), prospective and retrospective studies were included. Data were extracted independently by two authors from studies that fulfilled the inclusion criteria. Mandibular length changes of class II patients treated with functional appliances were collated for each retrieved study. Results From 6796 potentially eligible studies, 90 were considered for this systematic review. Four were RCTs which were graded with the Cochrane risk of bias tool. Three were assessed as having low and one as having moderate risk of bias. The other 86 studies were graded with the modified Downs and Black tool which revealed that 47 showed low, 38 low/moderate, and 1 a moderate risk of bias. The most commonly assessed appliances were the Twin Block which was used on 783 patients, the Frankel appliance on 573, the Herbst appliance on 530, the Activator on 449, the Forsus appliance on 394, the MARA appliance on 202, and the Bionator on 133, for a total of 3064 treated patients. Conclusion This systematic review provides conclusive evidence that the Twin Block appliance demonstrated the highest coefficient of efficiency among all the evaluated appliances (0.46 mm/month), while the Forsus fatigue resistant device (FFRD) had the highest coefficient of efficiency among the fixed functional appliances (0.41 mm/month).
- 10 April 2025
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 87 (3) , 306-333
Coefficient of efficiency and effectiveness of functional appliances in class II malocclusion treatment
Objective To evaluate the coefficient of efficiency and effectiveness of removable and fixed functional appliances in class II malocclusion treatment. Data sources Search of studies in five databases (Medline via PubMed, Cochrane library, LILACS, SCOPUS, and SciELO) that measured mandibular skeletal changes following functional therapy was conducted until 15 April 2024. Study selection All study designs including randomized and controlled clinical trials (RCT), prospective and retrospective studies were included. Data were extracted independently by two authors from studies that fulfilled the inclusion criteria. Mandibular length changes of class II patients treated with functional appliances were collated for each retrieved study. Results From 6796 potentially eligible studies, 90 were considered for this systematic review. Four were RCTs which were graded with the Cochrane risk of bias tool. Three were assessed as having low and one as having moderate risk of bias. The other 86 studies were graded with the modified Downs and Black tool which revealed that 47 showed low, 38 low/moderate, and 1 a moderate risk of bias. The most commonly assessed appliances were the Twin Block which was used on 783 patients, the Frankel appliance on 573, the Herbst appliance on 530, the Activator on 449, the Forsus appliance on 394, the MARA appliance on 202, and the Bionator on 133, for a total of 3064 treated patients. Conclusion This systematic review provides conclusive evidence that the Twin Block appliance demonstrated the highest coefficient of efficiency among all the evaluated appliances (0.46 mm/month), while the Forsus fatigue resistant device (FFRD) had the highest coefficient of efficiency among the fixed functional appliances (0.41 mm/month).
- Open Access
- 1 January 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 12142-12148
Comparative Evaluation of Facial Changes, Smile Changes & Oral Hygiene with Passive Self-Ligation and Conventional Fixed Appliance in Class I Malocclusion Patients: A Perception Study
AIM: To investigate and compare the perception of pre and post treatment facial and smile changes between Passive Self-Ligation and Conventional Fixed Appliance in skeletal Class I malocclusion individuals.MATERIALS AND METHODS: A total of 20 extraoral pre and post treatment frontal posed smile photographs of patients treated with Conventional fixed and Passive Self-Ligation Appliance (10 per group) were included in this study. The frontal and posed smile photographs were evaluated by 120 evaluators divided into three groups :40 Orthodontists, 40 General Dentists, 40 lay persons and were rated for the Smile Attractiveness, Smile Arc, Gum exposure and Buccal corridor space, Chin Projection & Changes in chin position. The Photographs were arranged in a randomized order between Passive Self-ligation and conventional appliance and evaluators rated them using Visual Analog Scale (VAS). In addition to the extraoral features, the oral hygiene and comfort of the appliance on intraoral photographs were also rated based on VAS by the evaluators.RESULTS: Within the Conventional and Self-ligating appliances, the Orthodontists, General Dentists, and the Lay persons perceived a difference between Pre and Post treatment. However, between the two groups no significant difference was seen in their Smile Attractiveness, Smile Arc, Gum exposure, Buccal corridor space, Chin Projection, Change in their chin position, oral hygiene, or comfort.CONCLUSIONS: Minimal difference in Smile Attractiveness, Smile Arc, Gum exposure, Buccal corridor space, Chin Projection, change in their chin position, oral hygiene and comfort was evident with Conventional fixed appliance and Self-ligating appliance.
- 1 January 2024
- Published by ARC Publication Services LLC
- Vol. 27 (4S) , 12142-12148
Open AccessComparative Evaluation of Facial Changes, Smile Changes & Oral Hygiene with Passive Self-Ligation and Conventional Fixed Appliance in Class I Malocclusion Patients: A Perception Study
AIM: To investigate and compare the perception of pre and post treatment facial and smile changes between Passive Self-Ligation and Conventional Fixed Appliance in skeletal Class I malocclusion individuals.MATERIALS AND METHODS: A total of 20 extraoral pre and post treatment frontal posed smile photographs of patients treated with Conventional fixed and Passive Self-Ligation Appliance (10 per group) were included in this study. The frontal and posed smile photographs were evaluated by 120 evaluators divided into three groups :40 Orthodontists, 40 General Dentists, 40 lay persons and were rated for the Smile Attractiveness, Smile Arc, Gum exposure and Buccal corridor space, Chin Projection & Changes in chin position. The Photographs were arranged in a randomized order between Passive Self-ligation and conventional appliance and evaluators rated them using Visual Analog Scale (VAS). In addition to the extraoral features, the oral hygiene and comfort of the appliance on intraoral photographs were also rated based on VAS by the evaluators.RESULTS: Within the Conventional and Self-ligating appliances, the Orthodontists, General Dentists, and the Lay persons perceived a difference between Pre and Post treatment. However, between the two groups no significant difference was seen in their Smile Attractiveness, Smile Arc, Gum exposure, Buccal corridor space, Chin Projection, Change in their chin position, oral hygiene, or comfort.CONCLUSIONS: Minimal difference in Smile Attractiveness, Smile Arc, Gum exposure, Buccal corridor space, Chin Projection, change in their chin position, oral hygiene and comfort was evident with Conventional fixed appliance and Self-ligating appliance.
- Open Access
- 17 July 2023
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 17 (2) , 71-80
Assessment of the outcomes and stability after mandibular incisor extraction in orthodontic patients: A systematic review and meta-analysis
Background. This study assessed the stability of the outcomes after mandibular incisor extraction (MIE) using intercanine width and peer assessment rating (PAR) scores in orthodontic patients. Methods. PubMed, Cochrane Library, Science Direct, Google Scholar, Ovid, and SciELO were systematically searched without restrictions until August 2022. A risk of bias assessment was performed using Newcastle-Ottawa Scale (NOS). The Grading of Recommendations, Assessment, Development, and Evaluation tool was used to assess the quality of evidence. Random effects meta-analysis was performed using RevMan software. Results. Seven retrospective studies met the inclusion criteria and were included. Meta-analysis identified a statistically significant reduction in intercanine width with MIE after the retention period. The mean difference in post-retention changes concerning intercanine width (MD=0.14, 95% CI: -2.17–1.89; P<0.00001) was significantly higher in premolar extraction (PE) compared to incisor extraction and significantly less in non-extraction compared to incisor extraction (MD=0.72, 95% CI: -0.59–2.03; P70%) with MIE treatment, with no significant difference in the reduction percentage compared to premolar and non-extraction groups. Conclusion. With the existing retrospective studies of limited evidence, treatment outcomes with MIE were found to show good improvements in PAR scores. Some reduction in the intercanine width was evident after the retention period, which was observed even with the other two treatment modalities that were compared. Hence, with careful evaluation, MIE could be considered a valid treatment option.
- 17 July 2023
- Published by Maad Rayan Publishing Company in Journal of Dental Research, Dental Clinics, Dental Prospects
- Vol. 17 (2) , 71-80
Open AccessAssessment of the outcomes and stability after mandibular incisor extraction in orthodontic patients: A systematic review and meta-analysis
Background. This study assessed the stability of the outcomes after mandibular incisor extraction (MIE) using intercanine width and peer assessment rating (PAR) scores in orthodontic patients. Methods. PubMed, Cochrane Library, Science Direct, Google Scholar, Ovid, and SciELO were systematically searched without restrictions until August 2022. A risk of bias assessment was performed using Newcastle-Ottawa Scale (NOS). The Grading of Recommendations, Assessment, Development, and Evaluation tool was used to assess the quality of evidence. Random effects meta-analysis was performed using RevMan software. Results. Seven retrospective studies met the inclusion criteria and were included. Meta-analysis identified a statistically significant reduction in intercanine width with MIE after the retention period. The mean difference in post-retention changes concerning intercanine width (MD=0.14, 95% CI: -2.17–1.89; P<0.00001) was significantly higher in premolar extraction (PE) compared to incisor extraction and significantly less in non-extraction compared to incisor extraction (MD=0.72, 95% CI: -0.59–2.03; P70%) with MIE treatment, with no significant difference in the reduction percentage compared to premolar and non-extraction groups. Conclusion. With the existing retrospective studies of limited evidence, treatment outcomes with MIE were found to show good improvements in PAR scores. Some reduction in the intercanine width was evident after the retention period, which was observed even with the other two treatment modalities that were compared. Hence, with careful evaluation, MIE could be considered a valid treatment option.
- 1 May 2021
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 159 (5) , 561
Authors’ response
- 1 May 2021
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 159 (5) , 561
Authors’ response
- 1 August 2020
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 158 (2) , 199-208
Evaluation of titanium dioxide coating on surface roughness of nickel-titanium archwires and its influence on Streptococcus mutans adhesion and enamel mineralization: A prospective clinical study
- 1 August 2020
- Published by Elsevier in American Journal of Orthodontics and Dentofacial Orthopedics
- Vol. 158 (2) , 199-208
Evaluation of titanium dioxide coating on surface roughness of nickel-titanium archwires and its influence on Streptococcus mutans adhesion and enamel mineralization: A prospective clinical study