Adam May
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Adam May has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Axel Krieger
Department of Mechanical Engineering, Johns Hopkins University, Baltimore, USA
2 shared publications - Lamar O. Mair
Division of Magnetic Manipulation and Particle Research Weinberg Medical Physics, Inc. Rockville Maryland USA
2 shared publications - Yancy Diaz-Mercado
Department of Mechanical Engineering University of Maryland College Park Maryland USA
2 shared publications - Anuruddha Bhattacharjee
Johns Hopkins University, Baltimore, MD, USA
1 shared publication - Ayush Saraswat
Department of Mechanical Engineering Johns Hopkins University Baltimore Maryland USA
1 shared publication Brian Dinh
Viterbi Family Department of Ophthalmology and Shiley Eye Institute, University of California, San Diego, 9415 Campus Point Drive, La Jolla, CA 92093-0946, USA
1 shared publication
Latest Publications
- 28 September 2026
- Published by Wiley in Advanced Materials Technologies
Wireless Modular Millirobots With Magnetic Actuation for Targeted Cardiac Drug Delivery
Infective endocarditis remains difficult to treat due to limited drug accumulation at infection sites via systemic delivery and reliance on invasive, high‐risk surgery. To address this, we present a wireless, modular millirobotic system actuated by external magnetic fields for targeted cardiac drug delivery. We validate the system in vitro using an agarose heart phantom under physiologically relevant pulsatile flow and ex vivo by demonstrating tissue penetration and module undocking in excised porcine heart tissue. The system comprises two cooperative millirobots: a barbed needle module that reduces tissue penetration force by 66.7% in cardiac tissue‐mimicking gels, and a drug module capable of delivering 22 microliter liquid doses over 180 min. AI‐assisted vision guidance enables autonomous navigation with root‐mean‐square tracking errors of 0.23 and 0.26 body lengths for the needle and drug modules, respectively. The modules support on‐demand magnetic docking and undocking, achieving success rates of 100% and 93%, respectively. These results highlight the potential of modular millirobots for precise, repeatable, and minimally invasive cardiac therapies.
- 28 September 2026
- Published by Wiley in Advanced Materials Technologies
Wireless Modular Millirobots With Magnetic Actuation for Targeted Cardiac Drug Delivery
Infective endocarditis remains difficult to treat due to limited drug accumulation at infection sites via systemic delivery and reliance on invasive, high‐risk surgery. To address this, we present a wireless, modular millirobotic system actuated by external magnetic fields for targeted cardiac drug delivery. We validate the system in vitro using an agarose heart phantom under physiologically relevant pulsatile flow and ex vivo by demonstrating tissue penetration and module undocking in excised porcine heart tissue. The system comprises two cooperative millirobots: a barbed needle module that reduces tissue penetration force by 66.7% in cardiac tissue‐mimicking gels, and a drug module capable of delivering 22 microliter liquid doses over 180 min. AI‐assisted vision guidance enables autonomous navigation with root‐mean‐square tracking errors of 0.23 and 0.26 body lengths for the needle and drug modules, respectively. The modules support on‐demand magnetic docking and undocking, achieving success rates of 100% and 93%, respectively. These results highlight the potential of modular millirobots for precise, repeatable, and minimally invasive cardiac therapies.
- 20 May 2026
- Published by Elsevier in Trends in Immunology
- Vol. 47 (6) , 453-455
Hijacked on arrival: glucocorticoids enable disseminated tumor cell immune evasion
- 20 May 2026
- Published by Elsevier in Trends in Immunology
- Vol. 47 (6) , 453-455
Hijacked on arrival: glucocorticoids enable disseminated tumor cell immune evasion
- 27 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
MagnetoStalsis: Generating Peristalsis in an Artificial Bowel for Treatment of Short Bowel Syndrome
Efforts to develop an artificial intestine for treatment of short bowel syndrome have thus far failed to achieve coordinated peristalsis. To address this, we introduce an implantable, biomimetic, magnetically-actuated peristaltic pumping apparatus. The system consists of a magnetic pump surrounding an intestinal graft and a rotating external magnetic field generator that produces peristaltic motion in the graft as the field direction alternates. We performed computational finite element modeling to simulate deformation and stress concentration on the pump. We then tested the ability of the system to produce fluid flow through porcine subintestinal submucosa at actuation frequencies from 0 Hz to 4 Hz. The system achieved a maximal flow rate of 6.03 mL/min at 3 Hz actuation frequency, which is in the physiological range of human intestinal flow rates. This device represents a novel proof-of-concept for achieving untethered peristalsis in an implantable intestinal graft that is primed for preclinical testing in animal models of short bowel syndrome.
- 27 July 2024
- Published by World Scientific Pub Co Pte Ltd in Journal of Medical Robotics Research
- Vol. 09 (03n04)
MagnetoStalsis: Generating Peristalsis in an Artificial Bowel for Treatment of Short Bowel Syndrome
Efforts to develop an artificial intestine for treatment of short bowel syndrome have thus far failed to achieve coordinated peristalsis. To address this, we introduce an implantable, biomimetic, magnetically-actuated peristaltic pumping apparatus. The system consists of a magnetic pump surrounding an intestinal graft and a rotating external magnetic field generator that produces peristaltic motion in the graft as the field direction alternates. We performed computational finite element modeling to simulate deformation and stress concentration on the pump. We then tested the ability of the system to produce fluid flow through porcine subintestinal submucosa at actuation frequencies from 0 Hz to 4 Hz. The system achieved a maximal flow rate of 6.03 mL/min at 3 Hz actuation frequency, which is in the physiological range of human intestinal flow rates. This device represents a novel proof-of-concept for achieving untethered peristalsis in an implantable intestinal graft that is primed for preclinical testing in animal models of short bowel syndrome.
- 1 September 2021
- Published by Elsevier in Experimental Eye Research
- Vol. 210, 108605
Ongoing controversies and recent insights of the ARMS2-HTRA1 locus in age-related macular degeneration
- 1 September 2021
- Published by Elsevier in Experimental Eye Research
- Vol. 210, 108605
Ongoing controversies and recent insights of the ARMS2-HTRA1 locus in age-related macular degeneration