Leon Glicksman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Leon Glicksman has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Johnathan Kongoletos
Department of Architecture, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Building 5-418, Cambridge, MA 02139, USA
3 shared publications - Daniele Testi
Department of Energy, Systems, Territory, and Constructions Engineering (DESTEC), University of Pisa, Largo Lucio Lazzarino, 56122 Pisa, Italy
2 shared publications - Ellann Cohen
Building Technology Program, Department of Architecture and Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139
2 shared publications - Eva Schito
Department of Energy, Systems, Territory and Constructions Engineering (DESTEC), University of Pisa, Pisa, Italy
2 shared publications - Paolo Conti
Department of Energy, Systems, Territory and Constructions Engineering (DESTeC), University of Pisa, 56122 Pisa, Italy
2 shared publications - Andrew Brose
Department of Architecture, Massachusetts Institute of Technology, Cambridge, MA, United States
1 shared publication
Latest Publications
- Open Access
Enhanced Night Cooling of Low-Energy Buildings Using Directed Ventilation
Night ventilation coupled with thermal mass is an effective means of reducing overheating in passive buildings. Successful systems require a high airflow rate coupled with enhanced convective heat transfer to the thermal mass. This work presents results for enhanced convection when the primary thermal mass is in the ceiling. Such mass distribution occurs, for example, in multi-story apartments in developing economies. Experimental results are measured in a scale model of a typical room. The original contribution is the use of upward-directed ventilation at an angle of 30° to 40° from a window located at a typical distance below the ceiling. At scaled air change rates of 4.9 air changes per hour, the measured convective heat transfer coefficient at the ceiling was 7.7 W/m2 K. In contrast, when air flowed horizontally from the window, the heat transfer coefficient was 3.5 W/m2 K or less, indicating that substantial improvement was gained by directing airflow toward the ceiling. To link the experimental results to an application in a full-size building, an approximate model is presented to estimate the impact of directed night ventilation on the thermal mass (specifically the concrete slab ceiling) and room air temperatures. Coupling angled flow with nighttime ventilation, the ceiling slab and peak daytime air temperature can be reduced by 5 °C compared to horizontal ventilation from a window at conventional height. These results have enabled collaborators in Gujarat, India, to launch tests in a full-scale home serving a low-income community without access to air conditioning.
Open AccessEnhanced Night Cooling of Low-Energy Buildings Using Directed Ventilation
Night ventilation coupled with thermal mass is an effective means of reducing overheating in passive buildings. Successful systems require a high airflow rate coupled with enhanced convective heat transfer to the thermal mass. This work presents results for enhanced convection when the primary thermal mass is in the ceiling. Such mass distribution occurs, for example, in multi-story apartments in developing economies. Experimental results are measured in a scale model of a typical room. The original contribution is the use of upward-directed ventilation at an angle of 30° to 40° from a window located at a typical distance below the ceiling. At scaled air change rates of 4.9 air changes per hour, the measured convective heat transfer coefficient at the ceiling was 7.7 W/m2 K. In contrast, when air flowed horizontally from the window, the heat transfer coefficient was 3.5 W/m2 K or less, indicating that substantial improvement was gained by directing airflow toward the ceiling. To link the experimental results to an application in a full-size building, an approximate model is presented to estimate the impact of directed night ventilation on the thermal mass (specifically the concrete slab ceiling) and room air temperatures. Coupling angled flow with nighttime ventilation, the ceiling slab and peak daytime air temperature can be reduced by 5 °C compared to horizontal ventilation from a window at conventional height. These results have enabled collaborators in Gujarat, India, to launch tests in a full-scale home serving a low-income community without access to air conditioning.
- 22 January 2025
- Published by Elsevier in Building and Environment
- Vol. 271
Experimental and CFD study of air distribution system and airflow rate impact on airborne transmission
- 22 January 2025
- Published by Elsevier in Building and Environment
- Vol. 271
Experimental and CFD study of air distribution system and airflow rate impact on airborne transmission
- 7 March 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 146 (5) , 1-26
Evaluation by Liquid Crystal Thermography of Transient Surface Temperature Distribution in Radiant Floor Cooling Applications and Assessment of Analytical and Numerical Models
The purpose of our study is to evaluate the surface temperature distribution on a radiant floor, particularly focusing on space cooling operations, to assess the presence of nonuniformities. In fact, knowing the temperature difference between the average superficial temperature and the coldest spot can be a useful indication for condensation prevention. Primarily, we performed an experimental campaign in test rooms using temperature sensors and liquid crystal thermography. This allowed us to evaluate the floor temperature distribution both on a local scale, influenced by the discontinuous presence of buried water pipes, and on a macroscale, influenced by internal use, objects, and boundary conditions of the surrounding space. Then, the experimental temperature field on the radiant floor surface has been compared with analytical and numerical models in steady-state and transient phases, respectively. The results indicate limited superficial temperature variations that become more significant at larger tube spacings and under transient conditions. In particular, the numerical transient analysis showed that shortly after a step change in the pipe's temperature boundary condition, a larger variation is locally observable on the floor, which then decays to the new steady-state conditions, presenting more uniformity. However, local effects are generally overshadowed by macro-effects, especially for practical scenarios where many objects, furnishings, and different boundary conditions are present. Finally, as a conservative guideline for the cooling system control, we recommend maintaining the average superficial floor temperature at least 1 °C above the dew point, to account for the described nonuniformities.
- 7 March 2024
- Published by ASME International in ASME Journal of Heat and Mass Transfer
- Vol. 146 (5) , 1-26
Evaluation by Liquid Crystal Thermography of Transient Surface Temperature Distribution in Radiant Floor Cooling Applications and Assessment of Analytical and Numerical Models
The purpose of our study is to evaluate the surface temperature distribution on a radiant floor, particularly focusing on space cooling operations, to assess the presence of nonuniformities. In fact, knowing the temperature difference between the average superficial temperature and the coldest spot can be a useful indication for condensation prevention. Primarily, we performed an experimental campaign in test rooms using temperature sensors and liquid crystal thermography. This allowed us to evaluate the floor temperature distribution both on a local scale, influenced by the discontinuous presence of buried water pipes, and on a macroscale, influenced by internal use, objects, and boundary conditions of the surrounding space. Then, the experimental temperature field on the radiant floor surface has been compared with analytical and numerical models in steady-state and transient phases, respectively. The results indicate limited superficial temperature variations that become more significant at larger tube spacings and under transient conditions. In particular, the numerical transient analysis showed that shortly after a step change in the pipe's temperature boundary condition, a larger variation is locally observable on the floor, which then decays to the new steady-state conditions, presenting more uniformity. However, local effects are generally overshadowed by macro-effects, especially for practical scenarios where many objects, furnishings, and different boundary conditions are present. Finally, as a conservative guideline for the cooling system control, we recommend maintaining the average superficial floor temperature at least 1 °C above the dew point, to account for the described nonuniformities.
- Open Access
Radiant Floor Cooling Systems: A Critical Review of Modeling Methods
Radiant floor heating systems have become a reference technology, but their use for cooling purposes has proven inconvenient in many applications due to their reduced cooling capacity and condensation issues. Nonetheless, potentialities and drawbacks of radiant floor cooling systems have been frequently addressed and simulated, given the large potential advantages of employing a single emissive system for all seasons. This paper aims to provide a comprehensive review of the modeling methods for radiant floor cooling systems proposed in scientific papers and also used in simulation software and technical standards. Models are classified according to their characterizing features, and the distinctive contributions of each method are discussed. Additionally, the modeling of the most relevant phenomena affecting floor performance is further discussed. The review revealed the presence of two main modeling classes, one only focusing on the floor’s conductive heat transfer and the other integrating active floor analysis within the building’s energy model of the thermal zone. Despite the presence of many modeling methods that are able to consider the most important effects in the radiant cooling system operation, not all the phenomena present in a practical application are fully described. Therefore, there is an ongoing need for more comprehensive, possibly easily characterizable, modeling approaches.
Open AccessRadiant Floor Cooling Systems: A Critical Review of Modeling Methods
Radiant floor heating systems have become a reference technology, but their use for cooling purposes has proven inconvenient in many applications due to their reduced cooling capacity and condensation issues. Nonetheless, potentialities and drawbacks of radiant floor cooling systems have been frequently addressed and simulated, given the large potential advantages of employing a single emissive system for all seasons. This paper aims to provide a comprehensive review of the modeling methods for radiant floor cooling systems proposed in scientific papers and also used in simulation software and technical standards. Models are classified according to their characterizing features, and the distinctive contributions of each method are discussed. Additionally, the modeling of the most relevant phenomena affecting floor performance is further discussed. The review revealed the presence of two main modeling classes, one only focusing on the floor’s conductive heat transfer and the other integrating active floor analysis within the building’s energy model of the thermal zone. Despite the presence of many modeling methods that are able to consider the most important effects in the radiant cooling system operation, not all the phenomena present in a practical application are fully described. Therefore, there is an ongoing need for more comprehensive, possibly easily characterizable, modeling approaches.
- Open Access
Patterns of SARS-CoV-2 Aerosol Spread in Typical Classrooms
Although current industry guidelines to control the spread of SARS-CoV-2 (COVID-19) have adopted a six-foot (∼1.8m) spacing between individuals indoors, recent evidence suggests that longer range spread is also responsible for infections in public spaces. The vehicle for long-range spread is smaller droplets or particles, termed bio-aerosols, or aerosols for short, which have a large surface area to volume ratio such that aerodynamic drag is much larger than gravity forces. The aerosols remain suspended in air for extended time periods and they essentially move with air currents. Prediction of the danger to occupants in a closed room when exposed to an infected individual requires knowledge of the period of exposure and the concentration level of aerosols in the breathing zone of an occupant. To obtain an estimate of the concentration level, a common assumption is well-mixed conditions within an interior space. This is obtained from a mass balance between the level of aerosol produced by an infected individual along with the airflow rate into and out of the entire space. In this work, we use computational fluid dynamics, verified by experimental results, to explore the aerosol concentration distribution in a typical classroom for several common conditions and compare these results to the well-mixed assumption. We use a tracer gas to simulate the flow and dispersion of the aerosol-air mixture. The two ventilation systems examined, ceiling diffusers and open windows, yield average concentrations at occupant breathing level 50% greater than the well mixed case, and some scenarios yield concentrations that are 150% greater than the well mixed concentration at specific breathing-level locations. Of particular concern are two conditions: horizontal air flow from an open window in line with a row of seating and, second, an infected individual seated near a sealed cold window. For the former, conditions are improved if a baffle is placed inside the open window to direct the air toward the floor, creating a condition similar to displacement ventilation. In the latter, the cold air flowing down along the cold window recirculates aerosols back into the breathing zone. Adding window covers or a portable heater below the window surface will moderate this condition.
Open AccessPatterns of SARS-CoV-2 Aerosol Spread in Typical Classrooms
Although current industry guidelines to control the spread of SARS-CoV-2 (COVID-19) have adopted a six-foot (∼1.8m) spacing between individuals indoors, recent evidence suggests that longer range spread is also responsible for infections in public spaces. The vehicle for long-range spread is smaller droplets or particles, termed bio-aerosols, or aerosols for short, which have a large surface area to volume ratio such that aerodynamic drag is much larger than gravity forces. The aerosols remain suspended in air for extended time periods and they essentially move with air currents. Prediction of the danger to occupants in a closed room when exposed to an infected individual requires knowledge of the period of exposure and the concentration level of aerosols in the breathing zone of an occupant. To obtain an estimate of the concentration level, a common assumption is well-mixed conditions within an interior space. This is obtained from a mass balance between the level of aerosol produced by an infected individual along with the airflow rate into and out of the entire space. In this work, we use computational fluid dynamics, verified by experimental results, to explore the aerosol concentration distribution in a typical classroom for several common conditions and compare these results to the well-mixed assumption. We use a tracer gas to simulate the flow and dispersion of the aerosol-air mixture. The two ventilation systems examined, ceiling diffusers and open windows, yield average concentrations at occupant breathing level 50% greater than the well mixed case, and some scenarios yield concentrations that are 150% greater than the well mixed concentration at specific breathing-level locations. Of particular concern are two conditions: horizontal air flow from an open window in line with a row of seating and, second, an infected individual seated near a sealed cold window. For the former, conditions are improved if a baffle is placed inside the open window to direct the air toward the floor, creating a condition similar to displacement ventilation. In the latter, the cold air flowing down along the cold window recirculates aerosols back into the breathing zone. Adding window covers or a portable heater below the window surface will moderate this condition.
- Open Access
- 7 March 2019
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 7
Coconut Fiber Cement Panels as Wall Insulation and Structural Diaphragm
This study considers the applications of natural fiber composites in affordable housing projects located in the two districts of Gujarat, India, and Gorkha, Nepal, with the goal of addressing issues of thermal comfort and lateral loading from seismic activity. To help alleviate some of these issues, the team worked with the Hunnarshala Foundation, in Bhuj, India, to develop a fiber cement composite that could be applied to the interior or exterior of a home and provide both insulative and structural improvements. Thermal conductivity of the composites comprised of various mixes were measured using a heat flux machine. Experimental results of 0.16–0.19 W/m·K showed an improvement in thermal conductivity compared to current wall cladding materials ranging from 1.60 to 1.88 W/m·K. Modeling of the building envelope was completed using the EnergyPlus™ tool and showed that homes using the fiber cement composites would have an overall reduction in heating and cooling requirements. The study used coconut husk fibers (referred to as coconut coir), rattan, and pine wood fibers in addition to Portland cement, fly ash, and hydrated lime in the fabrication of fiber cement composite samples. Flexural strength of natural fiber samples was 70% stronger than comparison specimens, suggesting possible application for wall cladding to reduce out-of-plane failure during seismic events. Field tests conducted in Gujarat validated lab results as well as qualitative perceptions of the material. Continued work with local partners presents several possible applications of coconut coir fiber cement composites for retrofit and new construction housing.
- 7 March 2019
- Published by Frontiers Media SA in Frontiers in Energy Research
- Vol. 7
Open AccessCoconut Fiber Cement Panels as Wall Insulation and Structural Diaphragm
This study considers the applications of natural fiber composites in affordable housing projects located in the two districts of Gujarat, India, and Gorkha, Nepal, with the goal of addressing issues of thermal comfort and lateral loading from seismic activity. To help alleviate some of these issues, the team worked with the Hunnarshala Foundation, in Bhuj, India, to develop a fiber cement composite that could be applied to the interior or exterior of a home and provide both insulative and structural improvements. Thermal conductivity of the composites comprised of various mixes were measured using a heat flux machine. Experimental results of 0.16–0.19 W/m·K showed an improvement in thermal conductivity compared to current wall cladding materials ranging from 1.60 to 1.88 W/m·K. Modeling of the building envelope was completed using the EnergyPlus™ tool and showed that homes using the fiber cement composites would have an overall reduction in heating and cooling requirements. The study used coconut husk fibers (referred to as coconut coir), rattan, and pine wood fibers in addition to Portland cement, fly ash, and hydrated lime in the fabrication of fiber cement composite samples. Flexural strength of natural fiber samples was 70% stronger than comparison specimens, suggesting possible application for wall cladding to reduce out-of-plane failure during seismic events. Field tests conducted in Gujarat validated lab results as well as qualitative perceptions of the material. Continued work with local partners presents several possible applications of coconut coir fiber cement composites for retrofit and new construction housing.
- 1 August 2015
- Published by Wiley in Journal of Heat Transfer
- Vol. 137 (8) , 081601
Thermal Properties of Silica Aerogel Formula
The thermal conductivity of silica aerogel developed in this research program was measured using the transient hot-wire technique. The thermal conductivity of monolithic samples drops significantly from 9.3 mW/m · K to 3.2 mW/m · K with modest pressure reduction from 1 atm to 0.1 atm. The same aerogel in granular form has a thermal conductivity of 15.0 mW/m · K at ambient gas pressure with a modest compression applied to compact the granules and reduce the air void sizes. Radiation heat transfer in the hot-wire test may not be representative of its contribution in large scale applications. Measurements of the monochromatic extinction coefficient over the wavelengths of interest resulted in a Rosseland mean extinction coefficient of 2400 m−1 at 300 K. The small thermal penetration distance during the hot-wire measurements suggest that in actual use radiation could contribute approximately 2.5 mW/m · K with a possible upper limit of 3.0 mW/m · K to the effective thermal conductivity over that measured using the transient hot-wire method.
- 1 August 2015
- Published by Wiley in Journal of Heat Transfer
- Vol. 137 (8) , 081601
Thermal Properties of Silica Aerogel Formula
The thermal conductivity of silica aerogel developed in this research program was measured using the transient hot-wire technique. The thermal conductivity of monolithic samples drops significantly from 9.3 mW/m · K to 3.2 mW/m · K with modest pressure reduction from 1 atm to 0.1 atm. The same aerogel in granular form has a thermal conductivity of 15.0 mW/m · K at ambient gas pressure with a modest compression applied to compact the granules and reduce the air void sizes. Radiation heat transfer in the hot-wire test may not be representative of its contribution in large scale applications. Measurements of the monochromatic extinction coefficient over the wavelengths of interest resulted in a Rosseland mean extinction coefficient of 2400 m−1 at 300 K. The small thermal penetration distance during the hot-wire measurements suggest that in actual use radiation could contribute approximately 2.5 mW/m · K with a possible upper limit of 3.0 mW/m · K to the effective thermal conductivity over that measured using the transient hot-wire method.
- 30 January 2014
- Published by Wiley in Journal of Heat Transfer
- Vol. 136 (4) , 041301
Analysis of the Transient Hot-Wire Method to Measure Thermal Conductivity of Silica Aerogel: Influence of Wire Length, and Radiation Properties
When the transient hot-wire method is used to measure the thermal conductivity of very low thermal conductivity silica aerogel (in the range of 10 mW/m·K at 1 atm) end effects due to the finite wire size and radiation corrections must be considered. An approximate method is presented to account for end effects with realistic boundary conditions. The method was applied to small experimental samples of the aerogel using different wire lengths. Initial conductivity results varied with wire length. This variation was eliminated by the use of the end effect correction. The test method was validated with the NIST (National Institute of Standards and Technology) Standard Reference Material 1459, fumed silica board to within 1 mW/m·K. The aerogel is semitransparent. Due to the small wire radius and short transient, radiation heat transfer may not be fully accounted for. In a full size aerogel panel radiation will augment the phonon conduction by a larger amount.
- 30 January 2014
- Published by Wiley in Journal of Heat Transfer
- Vol. 136 (4) , 041301
Analysis of the Transient Hot-Wire Method to Measure Thermal Conductivity of Silica Aerogel: Influence of Wire Length, and Radiation Properties
When the transient hot-wire method is used to measure the thermal conductivity of very low thermal conductivity silica aerogel (in the range of 10 mW/m·K at 1 atm) end effects due to the finite wire size and radiation corrections must be considered. An approximate method is presented to account for end effects with realistic boundary conditions. The method was applied to small experimental samples of the aerogel using different wire lengths. Initial conductivity results varied with wire length. This variation was eliminated by the use of the end effect correction. The test method was validated with the NIST (National Institute of Standards and Technology) Standard Reference Material 1459, fumed silica board to within 1 mW/m·K. The aerogel is semitransparent. Due to the small wire radius and short transient, radiation heat transfer may not be fully accounted for. In a full size aerogel panel radiation will augment the phonon conduction by a larger amount.
- 1 January 2008
- Published by Elsevier in Powder Technology
- Vol. 180 (3) , 284-288
Particle injection and mixing experiments in a one-quarter scale model bubbling fluidized bed
- 1 January 2008
- Published by Elsevier in Powder Technology
- Vol. 180 (3) , 284-288
Particle injection and mixing experiments in a one-quarter scale model bubbling fluidized bed
- 8 December 2005
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 128 (2) , 204-212
A Real Options Methodology for Evaluating Risk and Opportunity of Natural Ventilation
The variable, uncertain nature of climate imposes risk in using solar and building technologies, such as natural ventilation (NV). To maximize the potential benefit from NV while reducing risk, a building could be designed for NV along with the “real option” to install mechanical cooling in the future, if needed. Traditional evaluation procedures use expected values, which fail to acknowledge the value of uncertainty when system performance is a nonlinear function of the uncertain variable. A real options methodology is proposed to evaluate the flexible building design under climate uncertainty. A building energy simulation is used to obtain probability distributions of the cost savings of the option-based NV strategy and of the time when (if) the mechanical cooling system is installed. A simplified stochastic temperature generator is used, and it may be used to evaluate real options for other technologies sensitive to future climate. The results of a real options analysis provide information to project investors on (a) the likelihood of exercising the option, and (b) the improved financial value of the technology when implemented with a flexible strategy.
- 8 December 2005
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 128 (2) , 204-212
A Real Options Methodology for Evaluating Risk and Opportunity of Natural Ventilation
The variable, uncertain nature of climate imposes risk in using solar and building technologies, such as natural ventilation (NV). To maximize the potential benefit from NV while reducing risk, a building could be designed for NV along with the “real option” to install mechanical cooling in the future, if needed. Traditional evaluation procedures use expected values, which fail to acknowledge the value of uncertainty when system performance is a nonlinear function of the uncertain variable. A real options methodology is proposed to evaluate the flexible building design under climate uncertainty. A building energy simulation is used to obtain probability distributions of the cost savings of the option-based NV strategy and of the time when (if) the mechanical cooling system is installed. A simplified stochastic temperature generator is used, and it may be used to evaluate real options for other technologies sensitive to future climate. The results of a real options analysis provide information to project investors on (a) the likelihood of exercising the option, and (b) the improved financial value of the technology when implemented with a flexible strategy.