JOJoseph A. Orr

Joseph A. Orr

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joseph A. Orr has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Volatile anesthetic gas concentration sensing using flow sensor fusion for use in Austere settings

    by Patrick R. Kolbay, Joseph A. Orr, Kai Kück

    Flow sensors are often sensitive to the presence of volatile anesthetics. However, this sensitivity provides a unique opportunity to combine flow sensors of differing technological principles as an alternative to measuring volatile anesthetic gas concentration, particularly for austere settings. To determine the feasibility of flow sensor fusion for volatile anesthetic concentrations monitoring, eight flow sensors were tested with isoflurane, sevoflurane, and desflurane, ranging in concentrations from 0–4.5%, 0–3.5%, and 0–18%, respectively. Pairs of flow sensors were fit to the volatile anesthetic gas concentration with a leave-one-out cross-validation method to reduce the likelihood of overfitting. Bland–Altman was used for the final evaluation of sensor pair performance. Several sensor pairs yielded limits of agreement comparable to the rated accuracy of a commercial infrared spectrometer. The ultrasonic and orifice-plate flowmeters yielded the most combinations of viable sensor pairs for all three volatile anesthetic gases. Conclusion: Measuring volatile anesthetic gases using flow sensor fusion is a feasible low-cost, low-maintenance alternative to infrared spectroscopy. In this study, testing was done under steady-state conditions in 100% oxygen. Further testing is necessary to ensure sensor fusion performance under conditions that are more reflective of the clinical use case.


  • Efficient sampling for polynomial chaos‐based uncertainty quantification and sensitivity analysis using weighted approximate Fekete points

    by Kyle M. Burk, Akil Narayan, Joseph A. Orr

    Performing uncertainty quantification (UQ) and sensitivity analysis (SA) is vital when developing a patient‐specific physiological model because it can quantify model output uncertainty and estimate the effect of each of the model's input parameters on the mathematical model. By providing this information, UQ and SA act as diagnostic tools to evaluate model fidelity and compare model characteristics with expert knowledge and real world observation. Computational efficiency is an important part of UQ and SA methods and thus optimization is an active area of research. In this work, we investigate a new efficient sampling method for least‐squares polynomial approximation, weighted approximate Fekete points (WAFP). We analyze the performance of this method by demonstrating its utility in stochastic analysis of a cardiovascular model that estimates changes in oxyhemoglobin saturation response. Polynomial chaos (PC) expansion using WAFP produced results similar to the more standard Monte Carlo in quantifying uncertainty and identifying the most influential model inputs (including input interactions) when modeling oxyhemoglobin saturation, PC expansion using WAFP was far more efficient. These findings show the usefulness of using WAFP based PC expansion to quantify uncertainty and analyze sensitivity of a oxyhemoglobin dissociation response model. Applying these techniques could help analyze the fidelity of other relevant models in preparation for clinical application.


  • Comparing Nasal End-Tidal Carbon Dioxide Measurement Variation and Agreement While Delivering Pulsed and Continuous Flow Oxygen in Volunteers and Patients

    by Kyle M. Burk, Derek J. Sakata, Kai Kuck, Joseph A. Orr

    BACKGROUND: Supplemental oxygen is administered during procedural sedation to prevent hypoxemia. Continuous flow oxygen, the most widespread method, is generally adequate but distorts capnography. Pulsed flow oxygen is novel and ideally will not distort capnography. We have developed a prototype oxygen administration system designed to try to facilitate end-tidal carbon dioxide (ETco 2) measurement. We conducted a volunteer study (ClinicalTrials.gov, NCT02886312) to determine how much nasal ETco 2 measurements vary with oxygen flow rate. We also conducted a clinical study (NCT02962570) to determine the median difference and limits of agreement between ETco 2 measurements made with and without administering oxygen. METHODS: Both studies were conducted at the University of Utah and participants acted as their own control. Inclusion criteria were age 18 years and older with an American Society of Anesthesiologists physical status of I–III. Exclusion criteria included acute respiratory distress syndrome, pneumonia, lung or cardiovascular disease, nasal/bronchial congestion, pregnancy, oxygen saturation measured by pulse oximetry 2. For the clinical study, ETco 2 measurements (the primary outcome) were collected while administering pulsed and continuous flow at rates between 1 and 5 L/min and were compared to measurements without oxygen flow. Due to institutional review board requirements for patient safety, this study was not randomized. After completing the study, measurements with and without administering oxygen were analyzed to determine median differences and 95% limits of agreement for each administration technique. RESULTS: Thirty volunteers and 60 patients participated in these studies which ended after enrolling the predetermined number of participants. In volunteers, the median absolute deviation for ETco 2 measurements made while administering pulsed flow oxygen (0.89; 25%–75% quantiles: 0.3–1.2) was smaller than while administering continuous flow oxygen (3.93; 25%–75% quantiles: 2.2–6.2). In sedated patients, the median difference was larger during continuous flow oxygen (−6.8 mm Hg; 25%–75% quantiles: −12.5 to −2.1) than during pulsed flow oxygen (0.1 mm Hg; 25%–75% quantiles: −0.5 to 1.5). The 95% limits of agreement were also narrower during pulsed flow oxygen (−2.4 to 4.5 vs −30.5 to 2.4 mm Hg). CONCLUSIONS: We have shown that nasal ETco 2 measurements while administering pulsed flow have little deviation and agree well with measurements made without administering oxygen. We have also demonstrated that ETco 2 measurements during continuous flow oxygen have large deviation and wide limits of agreement when compared with measurements made without administering oxygen.


  • A procedure for determining subject-specific pulse oxygen saturation response

    by Kyle M. Burk, Joseph A. Orr

    The oxyhemoglobin dissociation curve describes the relationship between the partial pressure of oxygen and the percent of hemoglobin saturated with oxygen and varies with chemical and physical factors that differ for every patient. If variability could be determined, patient-specific oxygen therapy could be administered. We have developed a procedure for characterizing variations in the oxygen dissociation curve. The purpose of this study was to validate this procedure in surgical patients. The procedure uses an automated system to alter oxygen therapy during surgery, within safe operational levels, and fit to Hill’s equation non-invasive measurements of end-tidal oxygen and peripheral pulse oxygen saturation. The best-fit parameters for the Hill equation, estimated by iterative least squares, provide an apparent dissociation curve, meaningful of the patient-specific pulse oximeter response. Thirty-nine patients participated in this study. Using patient-specific parameter values increases correlation when compared with standard values. The procedure improved the model fit of patient saturation values significantly in 19 patients. This paper has demonstrated a procedure for determining patient-specific pulse oximeter response. This procedure determined best-fit parameters resulting in a significantly improved fit when compared with standard values. These best-fit parameters increased the coefficient of determination R2 in all cases. This patient-specific procedure improves fit significantly compared to standard estimates


  • A comparison of ventilation with a non-invasive ventilator versus standard O2 with a nasal cannula for colonoscopy with moderate sedation using propofol

    by Mike Fogarty, Joseph A. Orr, Derek Sakata, Lara Brewer, Ken Johnson, John C. Fang, Kai Kuck

    The aim of this study was to test the effects of CPAP on moderately sedated patients undergoing colonoscopy. Our hypothesis was that CPAP can reduce the incidence and duration of obstructive apnea and hemoglobin oxygen desaturation in patients undergoing procedural sedation for colonoscopy. Two groups of consenting adult patients scheduled to undergo routine colonoscopy procedures and sedated with propofol and fentanyl were monitored in this study: control and intervention. Patients in the intervention group were connected via a facemask to a ventilator that delivered supplemental oxygen (100%) through a standard air-cushion mask. The mask had a built-in leak to facilitate CO2 clearance during CPAP. Patients in the control group received 2–10 L/min of oxygen via nasal cannula or non-rebreather mask. Subjects in the control group were collected in a prior study and used as historical controls. The primary outcome measures were the number of apneic events and the cumulative duration of apneic events. An apneic event was defined as a period longer than 10 s without respiration. The secondary outcome was the area under the curve (AUC) for the arterial oxygen saturation less than 90% versus time during sedative and analgesic administration (time (s) below threshold multiplied by percent below threshold). A desaturation event was defined as a period of time during which arterial oxygen saturation was less than 90%. 29 patients were enrolled in the intervention group and 156 patients were previously enrolled in the control group as part of an earlier study. The median number of apneic events in the control group was 7 compared to 0 in the intervention group. The intervention group experienced apnea less than 1% of the total procedure time compared to 17% in the control group (p < 0.001). There were no desaturation events observed in the 29 patients in the intervention group. In contrast, 27 out of 156 patients in the control group experienced a desaturation event. Average AUC of patients in the control group was 70%-s (time (s) * oxygen saturation below < 90%) (95% CI 32.34–108.60%) whereas the average AUC in intervention group patients was 0%-s (% time (s) * oxygen saturation < 90%) (95% CI 0–0%), p = 0.01. This preliminary study found that CPAP via a tight-fitting mask may be an effective tool to reduce the incidence and duration of obstructive apneic events as well as hemoglobin oxygen desaturation during lower endoscopy procedures that use propofol and fentanyl for sedation. Clinical Trial Registration ClinicalTrials.gov ID: NCT02623270. https://clinicaltrials.gov/ct2/show/NCT02623270.


  • A comparison of controlled ventilation with a noninvasive ventilator versus traditional mask ventilation

    by Mike Fogarty, Kai Kuck, Joseph Orr, Derek Sakata

    After induction, but before intubation, many general anesthesia patients are manually bag-mask ventilated. The objective of this study was to determine the efficacy of bag-mask ventilation (MkV) of an anesthetized patient versus mask ventilation using a noninvasive ventilator (NIV). We hypothesized that feedback-controlled, mask ventilation via NIV is more efficacious and safer. This critical short period of time in the operating room was chosen to compare MkV versus NIV. 30 ASA I–III patients, aged 18–74, presenting for elective surgery under general anesthesia were enrolled in the study. Patients were ventilated first with MkV and then with NIV. One minute of ventilation data was collected for each method. Respiratory inductance plethysmography (RIP) bands around the chest and abdomen were used to measure tidal volumes and breath rates for each method of ventilation. The NIV was set to deliver 10 breaths per minute with 12 cmH2O of pressure support. A non-inferiority test was used to compare MkV and NIV. MkV breaths had an average of 13 breaths and tidal volume of 364 mL (SD 145 mL). NIV resulted in an average of 10 breaths and tidal volume of 552 mL, i.e., 188 mL more than MkV (lower bound of the 95% confidence interval equal to 120 mL). The hypothesis of non-inferiority at the − 100 mL level and the superiority hypothesis at the + 100 mL level was accepted. NIV also resulted in much more consistent ventilation rates (zero variation since it is controlled by the ventilator) when compared to manual ventilation while maintaining safe airway pressures (8 cmH2O EPAP and 20 cmH2O IPAP). Feedback controlled mask ventilation via a NIV is a viable alternative to MkV. It can deliver more optimal tidal volumes with the operator utilizing only one hand. The airway pressures are fixed at safe limits during a period where the goal is to reach a maximal level of oxygenation prior to intubation. Over-ventilation or over-pressurization of the airway is not a concern with NIV since the pressures are maintained well within safe thresholds to avoid injury.


  • Evaluation and application of a method for estimating nasal end-tidal O2 fraction while administering supplemental O2

    by Kyle M. Burk, Kai Kuck, Joseph A. Orr

    This paper describes a method for estimating the oxygen enhanced end-tidal fraction of oxygen (FetOe), the end-tidal fraction of oxygen (FetO2) that is raised by administering supplemental oxygen. The paper has two purposes: the first is to evaluate the method’s accuracy on the bench and in volunteers; the second purpose is to demonstrate how to apply the method to compare two techniques of oxygen administration. The method estimates FetOe by analyzing expired oxygen as oxygen washes out of the lung. The method for estimating FetOe was first validated using a bench simulation in which tracheal oxygen was measured directly. Then it was evaluated in 30 healthy volunteers and compared to the bench simulation. Bland–Altman analysis compared calculated and observed FetOe/FetO2 measurements. After the method was evaluated, it was implemented to compare the FetOe obtained when administering oxygen using two different techniques (pulsed and continuous flow). A total of eighteen breath washout conditions were evaluated on the bench. FetOe estimates and tracheal FetO2 had a mean difference of − 0.016 FO2 with 95% limits of agreement from − 0.048 to 0.016 FO2. Thirteen breath washouts per volunteer were analyzed. Extrapolated and observed FetO2 had a mean difference of − 0.001 FO2 with 95% limits of agreement from − 0.006 to 0.004 FO2. Pulsed flow oxygen (PFO) achieved the same FetOe values as continuous flow oxygen (CFO) using 32.1% ± 2.27% (mean ± SD) of the CFO rate. This paper has demonstrated that the method estimates FetO2 enhanced by administering supplemental oxygen with clinically insignificant differences. This paper has also shown that PFO can obtain FetO2 similar to CFO using approximately one-third of the oxygen volume. After evaluating this method, we conclude that the method provides useful estimates of nasal FetO2 enhanced by supplemental oxygen administration.