Kátia Cordeiro Mendonça
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kátia Cordeiro Mendonça has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Nathan Mendes
Pontifical Catholic University of Parana (PUCPR)
3 shared publications Claudine Béghein
LASIE UMR 7356 CNRS, University of La Rochelle, La Rochelle, France
2 shared publications- Luciano Antonio Mendes
Mechanical Engineering Department, Pontifícia Universidade Católica do Paraná, Curitiba, Brazil
2 shared publications - Luís Mauro Moura
Pontifícia Universidade Católica do Paraná, Brasil
2 shared publications - Marc Olivier Abadie
EDF R&D PRISME, 6 Quai Watier, F-78400 Chatou, France
2 shared publications - Marcos Antônio Garcia
Refrigerating and Air-conditioning Department, Federal Institute of Santa Catarina, São José, Brazil
2 shared publications
Latest Publications
- 14 July 2022
- Published by Taylor & Francis in Journal of Applied Aquaculture
- Vol. 35 (4) , 1162-1178
A technological solution for preserving the quantity and quality of oysters grown in Brazil
Summer mortality of Crassostrea gigas occurs in Brazilian crops, with predominance in the final phase of cultivation, when they reach the commercial size, generating significant losses for local producers. In order to mitigate this problem, a technical solution, whose principle is based on long-term confinement at low temperatures (10 −12°C) for inducing a similar basal metabolism regime, has been developed. According to the current literature, if the spawning process is not triggered, a substantial reduction in the mortality rate can be achieved. This work evaluates not only the effectiveness of this technological solution to reduce summer mortality but also the quality associated to commercial attributes of the oysters as a final product. A ninety-one day experiment has been carried out and has shown that the proposed solution is able to maintain Crassostrea gigas diploid oysters alive and healthy.
- 14 July 2022
- Published by Taylor & Francis in Journal of Applied Aquaculture
- Vol. 35 (4) , 1162-1178
A technological solution for preserving the quantity and quality of oysters grown in Brazil
Summer mortality of Crassostrea gigas occurs in Brazilian crops, with predominance in the final phase of cultivation, when they reach the commercial size, generating significant losses for local producers. In order to mitigate this problem, a technical solution, whose principle is based on long-term confinement at low temperatures (10 −12°C) for inducing a similar basal metabolism regime, has been developed. According to the current literature, if the spawning process is not triggered, a substantial reduction in the mortality rate can be achieved. This work evaluates not only the effectiveness of this technological solution to reduce summer mortality but also the quality associated to commercial attributes of the oysters as a final product. A ninety-one day experiment has been carried out and has shown that the proposed solution is able to maintain Crassostrea gigas diploid oysters alive and healthy.
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 93 (1) , e20190505
Comparative analysis of hydraulic refrigeration and mechanical vapour compression water cooling technologies in designing a technical system for oysters conservation.
The phenomenon of summer mortality in Pacific oysters cultures also occurs in Brazilian crops, with predominance in the adult phase, generating significant losses for local producers. In the search for a technological solution to mitigate its effects, the mechanical vapour compression and hydraulic refrigeration concepts are evaluated as two proposed cooling technologies. The comparative analysis carried out with numeric simulations indicated that the hydraulic cooling system presents disadvantages regarding both the size of the compression column and the energy efficiency, compared to the mechanical vapour compression cycle. By computing only the compression power, a COP value of 6.9 results for the MVCS at TCOND = 29.5 oC and TEVAP = 7.2 oC, while for HRS the COP value is around 3.1 for identical conditions. Results from the analysis contradict former publications, but are consistent with recent findings reported in literature.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Anais da Academia Brasileira de Ciências
- Vol. 93 (1) , e20190505
Open AccessComparative analysis of hydraulic refrigeration and mechanical vapour compression water cooling technologies in designing a technical system for oysters conservation.
The phenomenon of summer mortality in Pacific oysters cultures also occurs in Brazilian crops, with predominance in the adult phase, generating significant losses for local producers. In the search for a technological solution to mitigate its effects, the mechanical vapour compression and hydraulic refrigeration concepts are evaluated as two proposed cooling technologies. The comparative analysis carried out with numeric simulations indicated that the hydraulic cooling system presents disadvantages regarding both the size of the compression column and the energy efficiency, compared to the mechanical vapour compression cycle. By computing only the compression power, a COP value of 6.9 results for the MVCS at TCOND = 29.5 oC and TEVAP = 7.2 oC, while for HRS the COP value is around 3.1 for identical conditions. Results from the analysis contradict former publications, but are consistent with recent findings reported in literature.
- 1 July 2020
- Published by Elsevier in Building and Environment
- Vol. 179
On the development of a simplified model for thermal comfort control of split systems
- 1 July 2020
- Published by Elsevier in Building and Environment
- Vol. 179
On the development of a simplified model for thermal comfort control of split systems
- 17 April 2020
- Published by Springer Nature in Building Simulation
- Vol. 13 (4) , 913-929
On the use of particle-wall interaction models to predict particle-laden flow in 90-deg bends
- 17 April 2020
- Published by Springer Nature in Building Simulation
- Vol. 13 (4) , 913-929
On the use of particle-wall interaction models to predict particle-laden flow in 90-deg bends
- 1 September 2014
- Published by Elsevier in Applied Energy
- Vol. 129, 243-252
Performance curves of room air conditioners for building energy simulation tools
- 1 September 2014
- Published by Elsevier in Applied Energy
- Vol. 129, 243-252
Performance curves of room air conditioners for building energy simulation tools
- 28 January 2014
- Published by Springer Nature in Building Simulation
- Vol. 7 (5) , 489-501
Assessing the capabilities of the zonal model to predict the isothermal airflow induced by a linear ceiling diffuser
- 28 January 2014
- Published by Springer Nature in Building Simulation
- Vol. 7 (5) , 489-501
Assessing the capabilities of the zonal model to predict the isothermal airflow induced by a linear ceiling diffuser
- 1 February 2012
- Published by Elsevier in Building and Environment
- Vol. 48, 173-182
Improving the prediction of zonal modeling for forced convection airflows in rooms
- 1 February 2012
- Published by Elsevier in Building and Environment
- Vol. 48, 173-182
Improving the prediction of zonal modeling for forced convection airflows in rooms
- 1 November 2010
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 37 (9) , 1197-1202
A full-scale experimental set-up for evaluating the moisture buffer effects of porous material
- 1 November 2010
- Published by Elsevier in International Communications in Heat and Mass Transfer
- Vol. 37 (9) , 1197-1202
A full-scale experimental set-up for evaluating the moisture buffer effects of porous material
- 12 August 2009
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 2 (4) , 251-266
Study of moisture transfer in a double-layered wall with imperfect thermal and hydraulic contact resistances
The objective of this work is to study the effect of taking into account interface contact resistance on the prediction of moisture distribution through multilayered building envelope. Therefore, two mathematical models to describe coupled heat and mass transfer in double-layered porous materials have been investigated: one that considers imperfect contact between layers and another that ignores this phenomenon. Both models are one-dimensional and were implemented using finite difference technique with an implicit scheme. Numerical results are presented in terms of moisture distribution for a double-layered wall and compared with the experimental data available in the current literature. The comparison has shown that the model that disregards interface contact resistance between layers cannot predict correctly one-dimensional heat and moisture transfer within double-layered porous materials. The sensitivity analysis of the simulation parameters and the impact of contact resistances at the whole building level are presented in detail and their effect on the whole building level was analysed. Our results suggest that the thermal contact resistance is the most influent parameter on the moisture flux across the hydraulic contact interface. On the whole building level, simulations indicate that taking into account contact resistances had a slight effect on the indoor relative humidity but a noticeable effect on heating input energy. A decrease of 10% in energy consumption is obtained when contact resistances are considered.
- 12 August 2009
- Published by Taylor & Francis in Journal of Building Performance Simulation
- Vol. 2 (4) , 251-266
Study of moisture transfer in a double-layered wall with imperfect thermal and hydraulic contact resistances
The objective of this work is to study the effect of taking into account interface contact resistance on the prediction of moisture distribution through multilayered building envelope. Therefore, two mathematical models to describe coupled heat and mass transfer in double-layered porous materials have been investigated: one that considers imperfect contact between layers and another that ignores this phenomenon. Both models are one-dimensional and were implemented using finite difference technique with an implicit scheme. Numerical results are presented in terms of moisture distribution for a double-layered wall and compared with the experimental data available in the current literature. The comparison has shown that the model that disregards interface contact resistance between layers cannot predict correctly one-dimensional heat and moisture transfer within double-layered porous materials. The sensitivity analysis of the simulation parameters and the impact of contact resistances at the whole building level are presented in detail and their effect on the whole building level was analysed. Our results suggest that the thermal contact resistance is the most influent parameter on the moisture flux across the hydraulic contact interface. On the whole building level, simulations indicate that taking into account contact resistances had a slight effect on the indoor relative humidity but a noticeable effect on heating input energy. A decrease of 10% in energy consumption is obtained when contact resistances are considered.
- 1 May 2009
- Published by Elsevier in Building and Environment
- Vol. 44 (5) , 971-986
Evaluating the influence of the width of inlet slot on the prediction of indoor airflow: Comparison with experimental data
- 1 May 2009
- Published by Elsevier in Building and Environment
- Vol. 44 (5) , 971-986
Evaluating the influence of the width of inlet slot on the prediction of indoor airflow: Comparison with experimental data