KTKe Tian

Ke Tian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ke Tian has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Fanggang Bi

    Sports Medicine Department of Orthopedics, Orthopedic Disease Areas, The First Affiliated Hospital of Zhengzhou University. No. 1, Zhengzhou City, Henan Province, China

    2 shared publications
  • Fanggang Bi

    Department of Orthopedics The First Affiliated Hospital of Zhengzhou University Zhengzhou China

    2 shared publications
  • Pengju Li

    Department of Orthopedic Surgery, the Honghui Hospital of Xi’an, Xi’an, China

    2 shared publications
  • Yafei Wang

    Department of Orthopedic Surgery, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China

    2 shared publications
  • Changyu Shen

    State Key Laboratory of Structural Analysis, Optimization and CAE Software for Industrial Equipment, National Engineering Research Center for Advanced Polymer Processing Technology, Zhengzhou University, Zhengzhou, China

    1 shared publication
  • Chengzhen Ren

    Department of Orthopedic Surgery, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China

    1 shared publication

Latest Publications

  • Open Access

    A hydrated HA/F127 biointerface for polyphenol release modulation and active–passive antibacterial protection on EGCG-loaded UHMWPE joint materials

    by Yu Han, Jiang-Yu Li, Shu-Min Pan, Peiqi Yu, Mengfan Jing, Yaming Wang, Yue Ren, Ke Tian, Chuntai Liu, Changyu Shen

    Periprosthetic joint infection remains a major challenge for artificial joint materials, highlighting the need for antibacterial and anti-adhesive ultrahigh molecular weight polyethylene (UHMWPE) surfaces. Here, a hydrated hyaluronic acid (HA)/Pluronic F127 biointerface was constructed on epigallocatechin gallate (EGCG)-loaded UHMWPE to couple polyphenol release modulation with active–passive antibacterial protection. The HA/F127 layer contributed to enhancing the outward migration of EGCG from the UHMWPE matrix. Compared with uncoated EGCG/UHMWPE, this hydrated interface increased the 24 h cumulative EGCG release by 52%, with micro-FTIR depth profiling revealing surface-biased residual EGCG redistribution rather than broad matrix depletion. This release-modulating interface enhanced antibacterial activity, achieving inhibition ratios of 95% against Staphylococcus aureus and 91% against Escherichia coli . By reducing protein adsorption and bacterial retention, the hydrated HA/F127 surface further provided passive anti-adhesive protection complementary to EGCG-mediated bacterial inhibition. The modified surface maintained good cytocompatibility and exhibited a short-term boundary-lubrication effect. Overall, this work presents an active-release/passive-antifouling biointerface strategy to address infection-related challenges of UHMWPE-based biomaterials. Graphical abstract A hydrated HA/F127 biointerface was constructed on EGCG-loaded UHMWPE through stepwise interfacial immobilization. The polymeric interface modulates EGCG release while reducing bacterial/protein adhesion, thereby coupling EGCG-mediated active antibacterial activity with passive anti-adhesion and boundary lubrication for infection-resistant UHMWPE joint materials.

  • Open Access

    The hydroxyapatite modified 3D printed poly L-lactic acid porous screw in reconstruction of anterior cruciate ligament of rabbit knee joint: a histological and biomechanical study

    by Yafei Wang, Chengzhen Ren, Fanggang Bi, Pengju Li, Ke Tian

    Background: 3D printing technology has become a research hotspot in the field of scientific research because of its personalized customization, maneuverability and the ability to achieve multiple material fabrications. The focus of this study is to use 3D printing technology to customize personalized poly L-lactic acid (PLLA) porous screws in orthopedic plants and to explore its effect on tendon-bone healing after anterior cruciate ligament (ACL) reconstruction. Methods: Preparation of PLLA porous screws with good orthogonal pore structure by 3D printer. The hydroxyapatite (HA) was adsorbed on porous screws by electrostatic layer-by-layer self-assembly (ELSA) technology, and PLLA-HA porous screws were prepared. The surface and spatial morphology of the modified screws were observed by scanning electron microscopy (SEM). The porosity of porous screw was measured by liquid displacement method. Thirty New Zealand male white rabbits were divided into two groups according to simple randomization. Autologous tendon was used for right ACL reconstruction, and porous screws were inserted into the femoral tunnel to fix the transplanted tendon. PLLA group was fixed with porous screws, PLLA-HA group was fixed with HA modified porous screws. At 6 weeks and 12 weeks after surgery, 5 animals in each group were sacrificed randomly for histological examination. The remaining 5 animals in each group underwent Micro-CT and biomechanical tests. Results: The pores of PLLA porous screws prepared by 3D printer were uniformly distributed and connected with each other, which meet the experimental requirements. HA was evenly distributed in the porous screw by ELSA technique. Histology showed that compared with PLLA group, mature bone trabeculae were integrated with grafted tendons in PLLA-HA group. Micro-CT showed that the bone formation index of PLLA-HA group was better than that of PLLA group. The new bone was uniformly distributed in the bone tunnel along the screw channel. Biomechanical experiments showed that the failure load and stiffness of PLLA-HA group were significantly higher than those of PLLA group. Conclusions: The 3D printed PLLA porous screw modified by HA can not only fix the grafted tendons, but also increase the inductivity of bone, promote bone growth in the bone tunnel and promote bone integration at the tendon-bone interface. The PLLA-HA porous screw is likely to be used in clinic in the future.


  • Open Access

    The hydroxyapatite modified 3D printed poly L-lactic acid porous screw in reconstruction of anterior cruciate ligament of rabbit knee joint: a histological and biomechanical study

    by Ke Tian, Yafei Wang, Fanggang Bi, Zhiyuan Wang, Chengzhen Ren, Pengju Li

    Background 3D printing technology has become a research hotspot in the field of scientific research because of its personalized customization, maneuverability and the ability to achieve multiple material fabrication. The focus of this study is to use 3D printing technology to to customize personalized orthopedic endosseous implant porous screws and to explore its effect on tendon-bone healing after anterior cruciate ligament (ACL)reconstruction. Methods The poly L-lactic acid (PLLA) porous screws which meet the requirements of the experiment are prepared by 3D printing technology. The hydroxyapatite (HA) was adsorbed on porous screws by electrostatic layer-by-layer self-assembly (ELSA) technology, and PLLA-HA porous screws were prepared.Scanning electron microscope (SEM) was used to observe the surface morphology of scaffolds before and after modification. Determination of porosity of screw support by liquid replacement method. The PLLA group was fixed with PLLA porous screw and the PLLA-HA group was fixed with PLLA-HA porous screw. Histology, imaging and biomechanics were observed at 6 and 12 weeks after operation. Results The PLLA porous screws prepared by 3D printer meet the design requirements, and the voids in the stents are evenly distributed and connected with each other. After surface modification, HA was uniformly distributed in PLLA screw scaffolds. Histology showed that compared with PLLA group, mature bone trabeculae were integrated with grafted tendons in PLLA-HA group. Micro-CT showed that the bone formation index of PLLA-HA group was better than that of PLLA group. The new bone was uniformly distributed in the bone tunnel along the screw channel. Biomechanical experiments showed that the failure load and stiffness of PLLA-HA group were significantly higher than those of PLLA group. Conclusions HA modified 3D printed porous screw can not only fix the transplanted tendon, but also effectively increase the new bone mass in the bone tunnel and promote the bone integration at the tendon-bone interface by promoting the bone growth in the bone tunnel.3D printed PLLA-HA porous screws are likely to be used in clinic in the future.3D printed PLLA-HA porous screws are likely to be used in clinic in the future.

  • Open Access

    Bone Mesenchymal Stem Cells Contribute to Ligament Regeneration and Graft–Bone Healing after Anterior Cruciate Ligament Reconstruction with Silk–Collagen Scaffold

    by Fanggang Bi, Yangdi Chen, Junqi Liu, Wenhao Hu, Ke Tian

    Anterior cruciate ligament (ACL) reconstruction was realized using a combination of bone mesenchymal stem cells (BMSCs) and silk–collagen scaffold, and an in vivo evaluation of this combination was performed. By combining type I collagen and degummed silk fibroin mesh, silk–collagen scaffolds were prepared to simulate ligament components. BMSCs isolated from bone marrow of rabbits were cultured for a homogenous population and seeded on the silk–collagen scaffold. In the scaffold and BMSC (S/C) group, scaffolds were seeded with BMSCs for 72 h and then rolled and used to replace the ACL in 20 rabbits. In the scaffold (S) group, scaffolds immersed only in culture medium for 72 h were used for ACL reconstruction. Specimens were collected at 4 and 16 weeks postoperatively to assess ligament regeneration and bone integration. HE and immunohistochemical staining (IHC) were performed to assess ligament regeneration in the knee cavity. To assess bone integration at the graft–bone interface, HE, Russell–Movat staining, micro-CT, and biomechanical tests were performed. After 4 weeks, vigorous cell proliferation was observed in the core part of the scaffold in the S/C group, and a quantity of fibroblast-like cells and extracellular matrix (ECM) was observed in the center part of the graft at 16 weeks after surgery. At 4 and 16 weeks postoperatively, the tenascin-C expression in the S/C group was considerably higher than that in the S group (4 w, ; 16 w, ). Furthermore, bone integration was better in the S/C group than in the S group, with histological observation of trabecular bone growth into the graft and more mineralized tissue formation detected by micro-CT (4 w, bone volume fraction (BV/TV), , bone mineral density (BMD), ; 16 w, BV/TV, , BMD, ). These results indicate that BMSCs promote ligament regeneration in the knee cavity and bone integration at the graft–bone interface. Silk–collagen scaffolds and BMSCs will likely be combined for clinical practice in the future.