Shuxiao Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuxiao Zhang has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Wei Feng
Chinese Academy of Sciences
3 shared publications - Shifeng Guo
Shenzhen Key Laboratory of Smart Sensing and Intelligent Systems, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
2 shared publications - Changchun Chai
School of Mechanical Science and Engineering, Huazhong University of Science and Technology
1 shared publication - Chunlong Fei
Faculty of Integrated Circuit, Xidian University, Xian 710126, China
1 shared publication - Di Li
Faculty of Integrated Circuit, Xidian University, Xian, China
1 shared publication - Dongdong Chen
Xidian University
1 shared publication
Latest Publications
- Open Access
- 18 December 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (25)
Deep-subwavelength ultrasonic imaging by MHz column-structured metalens: First evidence of quantitative visualization of subsurface defects
High-resolution ultrasonic imaging, which is highly demanded in nondestructive evaluation, is inherently limited by the detection wavelength. Acoustic metamaterial is an emerging technique to achieve subwavelength-resolution ultrasonic imaging beyond the diffraction limit due to its unprecedented acoustic properties. However, existing reports focus on metalenses for manipulating acoustic waves propagating in fluids like air and water, typically at a low-frequency range below 10 kHz. In this paper, a 0.5 MHz periodic column-structured metalens is designed and fabricated to realize deep-subwavelength ultrasonic imaging for quantitive visualization of subsurface defects in solid structures. The silicon-based metalens is designed based on Fabry–Pérot resonance theory. It consists of silicon columns arranged periodically with a lattice constant of 0.2 mm. The Fabry–Pérot resonance frequency is analyzed theoretically and the wave fields of the metalens at resonance mode are verified numerically. The subwavelength ultrasonic imaging performance of the proposed metalens is numerically proved and experimentally demonstrated. As a result, super-resolution ultrasonic imaging (λ/30, with λ being the wavelength) with a high resolving contrast is realized to identify two separated subsurface defects in a stainless-steel structure experimentally with the designed column-structured metalens. This work demonstrates a valuable deep-subwavelength imaging method that beyond traditional diffraction limits and paves the way for enhanced applications in nondestructive evaluation and biomedical diagnosis.
- 18 December 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 123 (25)
Open AccessDeep-subwavelength ultrasonic imaging by MHz column-structured metalens: First evidence of quantitative visualization of subsurface defects
High-resolution ultrasonic imaging, which is highly demanded in nondestructive evaluation, is inherently limited by the detection wavelength. Acoustic metamaterial is an emerging technique to achieve subwavelength-resolution ultrasonic imaging beyond the diffraction limit due to its unprecedented acoustic properties. However, existing reports focus on metalenses for manipulating acoustic waves propagating in fluids like air and water, typically at a low-frequency range below 10 kHz. In this paper, a 0.5 MHz periodic column-structured metalens is designed and fabricated to realize deep-subwavelength ultrasonic imaging for quantitive visualization of subsurface defects in solid structures. The silicon-based metalens is designed based on Fabry–Pérot resonance theory. It consists of silicon columns arranged periodically with a lattice constant of 0.2 mm. The Fabry–Pérot resonance frequency is analyzed theoretically and the wave fields of the metalens at resonance mode are verified numerically. The subwavelength ultrasonic imaging performance of the proposed metalens is numerically proved and experimentally demonstrated. As a result, super-resolution ultrasonic imaging (λ/30, with λ being the wavelength) with a high resolving contrast is realized to identify two separated subsurface defects in a stainless-steel structure experimentally with the designed column-structured metalens. This work demonstrates a valuable deep-subwavelength imaging method that beyond traditional diffraction limits and paves the way for enhanced applications in nondestructive evaluation and biomedical diagnosis.
- 1 December 2021
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 332, 113171
Intelligent optimization design of 2–2 piezo-composites for ultrasonic transducer
- 1 December 2021
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 332, 113171
Intelligent optimization design of 2–2 piezo-composites for ultrasonic transducer
- Open Access
- 1 January 2021
- Published by Wiley in Complexity
- Vol. 2021 (1)
Porosity Characterization of Thermal Barrier Coatings by Ultrasound with Genetic Algorithm Backpropagation Neural Network
Porosity is considered as one of the most important indicators for the characterization of the comprehensive performance of thermal barrier coatings (TBCs). In this study, the ultrasonic technique and the artificial neural network optimized with the genetic algorithm (GA_BPNN) are combined to develop an intelligent method for automatic detection and accurate prediction of TBCs’s porosity. A series of physical models of plasma‐sprayed ZrO2 coating are established with a thickness of 288 μm and porosity varying from 5.71% to 26.59%, and the ultrasonic reflection coefficient amplitude spectrum (URCAS) is constructed based on the time‐domain numerical simulation signal. The characteristic features (f1, f2, Amax, ΔA) of the URCAS, which are highly dependent on porosity, are extracted as input data to train the GA_BPNN model for predicting the unknown porosity. The average error of the prediction results is 1.45%, which suggests that the proposed method can achieve accurate detection and quantitative characterization of the porosity of TBCs with complex pore morphology.
- 1 January 2021
- Published by Wiley in Complexity
- Vol. 2021 (1)
Open AccessPorosity Characterization of Thermal Barrier Coatings by Ultrasound with Genetic Algorithm Backpropagation Neural Network
Porosity is considered as one of the most important indicators for the characterization of the comprehensive performance of thermal barrier coatings (TBCs). In this study, the ultrasonic technique and the artificial neural network optimized with the genetic algorithm (GA_BPNN) are combined to develop an intelligent method for automatic detection and accurate prediction of TBCs’s porosity. A series of physical models of plasma‐sprayed ZrO2 coating are established with a thickness of 288 μm and porosity varying from 5.71% to 26.59%, and the ultrasonic reflection coefficient amplitude spectrum (URCAS) is constructed based on the time‐domain numerical simulation signal. The characteristic features (f1, f2, Amax, ΔA) of the URCAS, which are highly dependent on porosity, are extracted as input data to train the GA_BPNN model for predicting the unknown porosity. The average error of the prediction results is 1.45%, which suggests that the proposed method can achieve accurate detection and quantitative characterization of the porosity of TBCs with complex pore morphology.