Georgia Balkourani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Georgia Balkourani has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Panagiotis Tsiakaras
Laboratory of Alternative Energy Conversion Systems, Department of Mechanical Engineering, School of Engineering, University of Thessaly, Pedion Areos, 38834 Volos, Greece
7 shared publications - Angeliki Brouzgou
Department of Energy Systems, School of Technology, University of Thessaly, Geopolis, Regional Road Trikala-Larisa, 41500 Larisa, Greece
5 shared publications - Carmelo Lo Vecchio
Institute of Advanced Energy Technologies “Nicola Giordano”, Consiglio Nazionale delle Ricerche, Via Salita Santa Lucia sopra Contesse, 5, 98126 Messina, Italy
2 shared publications - Manzar Sohail
Department of Chemistry, School of Natural Sciences, National University of Sciences and Technology, Islamabad 44000, Pakistan
2 shared publications P. Tsiakaras
2 shared publications- Vincenzo Baglio
Institute of Advanced Energy Technologies “Nicola Giordano”, Consiglio Nazionale delle Ricerche, Via Salita Santa Lucia sopra Contesse, 5, 98126 Messina, Italy
2 shared publications
Latest Publications
- Open Access
Nafion-Treated Nickel Oxide/Graphene (Nafion-NiOx/GP) Electrocatalysts for Dopamine Detection
Herein, (Nafion-treated) (30 wt%) NiOx/graphene (GP) were prepared at 250 °C and 450 °C and investigated as materials for dopamine electrochemical detection. Initially, characterization of the samples was performed using high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) techniques. Subsequently, they underwent electrochemical evaluation using cyclic voltammetry, linear sweep voltammetry (LSV), differential pulse voltammetry (DPV), and chronoamperometry (CA) techniques. All electrochemical measurements of the dopamine oxidation reaction (DOR) were performed in a 0.1 M phosphate buffer solution (PBS) at pH of 7.00 and at temperature of 36.6 °C. It was found that Nafion addition to the electrocatalysts surface facilitates access of the cationic dopamine molecule to their active centers being attributed to Nafion cation permeability. Nafion-NiO250/GP exhibited higher activity towards the DOR reaction. The limit of detection (LOD) for the lower linear range of 0.5–10 μM was calculated to be 0.8 μM, with a sensitivity of 3.086 μA μM−1cm−2. Furthermore, the Nafion NiO250/GP/GC electrode exhibited high selectivity towards DA, as well as good repeatability and reproducibility with an acceptable level of deviation, and excellent storage stability. The six electrodes produced from the Nafion-NiO250/GP showed 8.28% reproducibility (RSD), indicating adequate behavior, while the same electrode after six measurements over a 30-day period showed an RSD of 5.50%, indicating a reliable electrode.
Open AccessNafion-Treated Nickel Oxide/Graphene (Nafion-NiOx/GP) Electrocatalysts for Dopamine Detection
Herein, (Nafion-treated) (30 wt%) NiOx/graphene (GP) were prepared at 250 °C and 450 °C and investigated as materials for dopamine electrochemical detection. Initially, characterization of the samples was performed using high-resolution transmission electron microscopy (HRTEM), X-ray diffraction (XRD), and X-ray photoelectron spectroscopy (XPS) techniques. Subsequently, they underwent electrochemical evaluation using cyclic voltammetry, linear sweep voltammetry (LSV), differential pulse voltammetry (DPV), and chronoamperometry (CA) techniques. All electrochemical measurements of the dopamine oxidation reaction (DOR) were performed in a 0.1 M phosphate buffer solution (PBS) at pH of 7.00 and at temperature of 36.6 °C. It was found that Nafion addition to the electrocatalysts surface facilitates access of the cationic dopamine molecule to their active centers being attributed to Nafion cation permeability. Nafion-NiO250/GP exhibited higher activity towards the DOR reaction. The limit of detection (LOD) for the lower linear range of 0.5–10 μM was calculated to be 0.8 μM, with a sensitivity of 3.086 μA μM−1cm−2. Furthermore, the Nafion NiO250/GP/GC electrode exhibited high selectivity towards DA, as well as good repeatability and reproducibility with an acceptable level of deviation, and excellent storage stability. The six electrodes produced from the Nafion-NiO250/GP showed 8.28% reproducibility (RSD), indicating adequate behavior, while the same electrode after six measurements over a 30-day period showed an RSD of 5.50%, indicating a reliable electrode.
- Open Access
Electrochemical Detection of Dopamine: Novel Thin-Film Ti-Nanocolumnar Arrays/Graphene Monolayer-Cufoil Electrodes
Deposition at oblique vapor incidence angles can lead to the growth of thin films with dramatically changed morphological features. Herein, thin-film titanium nanocolumnar arrays were grown on a graphene monolayer/copper foil substrate (TiNCs/Gm-Cufoil) by applying a physical vapor deposition method, through magnetron sputtering at an oblique angle. Ti-nanocolumnar arrays with ca. 200 nm length were developed throughout the substrate with different morphologies depending on the substrate topography. It was found that over the as-fabricated electrocatalyst, the electrooxidation reaction of dopamine is facilitated, allowing quasi-reversible electrooxidation of protonated dopamine to dopamine quinone. Additionally, contrary to works that appeared in the literature, TiNCs/Gm-Cufoil also promotes further quasi-reversible oxidation of leucodopaminechrome to dopaminechrome. The electrode exhibited two linear ranges of dopamine detection (10–90 μM with a sensitivity value of 0.14 μAμM−1cm−2 and 100–400 μM with a sensitivity value of 0.095 μAμM−1cm−2), a good stability over time of about 30 days, and a good selectivity for dopamine detection.
Open AccessElectrochemical Detection of Dopamine: Novel Thin-Film Ti-Nanocolumnar Arrays/Graphene Monolayer-Cufoil Electrodes
Deposition at oblique vapor incidence angles can lead to the growth of thin films with dramatically changed morphological features. Herein, thin-film titanium nanocolumnar arrays were grown on a graphene monolayer/copper foil substrate (TiNCs/Gm-Cufoil) by applying a physical vapor deposition method, through magnetron sputtering at an oblique angle. Ti-nanocolumnar arrays with ca. 200 nm length were developed throughout the substrate with different morphologies depending on the substrate topography. It was found that over the as-fabricated electrocatalyst, the electrooxidation reaction of dopamine is facilitated, allowing quasi-reversible electrooxidation of protonated dopamine to dopamine quinone. Additionally, contrary to works that appeared in the literature, TiNCs/Gm-Cufoil also promotes further quasi-reversible oxidation of leucodopaminechrome to dopaminechrome. The electrode exhibited two linear ranges of dopamine detection (10–90 μM with a sensitivity value of 0.14 μAμM−1cm−2 and 100–400 μM with a sensitivity value of 0.095 μAμM−1cm−2), a good stability over time of about 30 days, and a good selectivity for dopamine detection.
- 17 April 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 669, 506-517
Efficient photocatalytic hydrogen peroxide production over S-scheme In2S3/molten salt modified C3N5 heterojunction
- 17 April 2024
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 669, 506-517
Efficient photocatalytic hydrogen peroxide production over S-scheme In2S3/molten salt modified C3N5 heterojunction
- 4 December 2023
- Published by Elsevier in Coordination Chemistry Reviews
- Vol. 501
Mxenes for Zn-based energy storage devices: Nano-engineering and machine learning
- 4 December 2023
- Published by Elsevier in Coordination Chemistry Reviews
- Vol. 501
Mxenes for Zn-based energy storage devices: Nano-engineering and machine learning
- Open Access
Recent Advances in Transition Metal Tellurides (TMTs) and Phosphides (TMPs) for Hydrogen Evolution Electrocatalysis
The hydrogen evolution reaction (HER) is a developing and promising technology to deliver clean energy using renewable sources. Presently, electrocatalytic water (H2O) splitting is one of the low-cost, affordable, and reliable industrial-scale effective hydrogen (H2) production methods. Nevertheless, the most active platinum (Pt) metal-based catalysts for the HER are subject to high cost and substandard stability. Therefore, a highly efficient, low-cost, and stable HER electrocatalyst is urgently desired to substitute Pt-based catalysts. Due to their low cost, outstanding stability, low overpotential, strong electronic interactions, excellent conductivity, more active sites, and abundance, transition metal tellurides (TMTs) and transition metal phosphides (TMPs) have emerged as promising electrocatalysts. This brief review focuses on the progress made over the past decade in the use of TMTs and TMPs for efficient green hydrogen production. Combining experimental and theoretical results, a detailed summary of their development is described. This review article aspires to provide the state-of-the-art guidelines and strategies for the design and development of new highly performing electrocatalysts for the upcoming energy conversion and storage electrochemical technologies.
Open AccessRecent Advances in Transition Metal Tellurides (TMTs) and Phosphides (TMPs) for Hydrogen Evolution Electrocatalysis
The hydrogen evolution reaction (HER) is a developing and promising technology to deliver clean energy using renewable sources. Presently, electrocatalytic water (H2O) splitting is one of the low-cost, affordable, and reliable industrial-scale effective hydrogen (H2) production methods. Nevertheless, the most active platinum (Pt) metal-based catalysts for the HER are subject to high cost and substandard stability. Therefore, a highly efficient, low-cost, and stable HER electrocatalyst is urgently desired to substitute Pt-based catalysts. Due to their low cost, outstanding stability, low overpotential, strong electronic interactions, excellent conductivity, more active sites, and abundance, transition metal tellurides (TMTs) and transition metal phosphides (TMPs) have emerged as promising electrocatalysts. This brief review focuses on the progress made over the past decade in the use of TMTs and TMPs for efficient green hydrogen production. Combining experimental and theoretical results, a detailed summary of their development is described. This review article aspires to provide the state-of-the-art guidelines and strategies for the design and development of new highly performing electrocatalysts for the upcoming energy conversion and storage electrochemical technologies.
- Open Access
Brief Review on High-Temperature Electrochemical Hydrogen Sensors
Hydrogen sensors, especially those operating at high temperatures, are essential tools for the emerging hydrogen economy. Monitoring hydrogen under process conditions to control the reactions for detecting confined species is crucial to the safe, widespread use and public acceptance of hydrogen as fuel. Hydrogen sensors must have a sensitivity ranging from traces of hydrogen (parts per million (ppm)) up to levels near the lower explosive limit (LEL = 4% H2 in the air) for safety reasons. Furthermore, they need to operate in cryogenic, ambient, and high-temperature environments. Herein, emphasis is given to hydrogen sensors based on solid oxide electrolytes (operating at high temperatures), in particular oxygen ion and proton conductors. The review is devoted to potentiometric, amperometric, and combined amperometric-potentiometric hydrogen sensors. Experimental results already reported in the international literature are presented and analyzed to reveal the configuration, principle of operation, and the applied solid electrolytes and electrodes of the high-temperature hydrogen sensors. Additionally, an amperometric sensor able to detect hydrogen and steam in atmospheric air through a two-stage procedure is presented and thoroughly discussed. The discussion reveals that high-temperature hydrogen sensors face different challenges in terms of the electrodes and solid electrolytes to be used, depending on the operating principle of each sensor type.
Open AccessBrief Review on High-Temperature Electrochemical Hydrogen Sensors
Hydrogen sensors, especially those operating at high temperatures, are essential tools for the emerging hydrogen economy. Monitoring hydrogen under process conditions to control the reactions for detecting confined species is crucial to the safe, widespread use and public acceptance of hydrogen as fuel. Hydrogen sensors must have a sensitivity ranging from traces of hydrogen (parts per million (ppm)) up to levels near the lower explosive limit (LEL = 4% H2 in the air) for safety reasons. Furthermore, they need to operate in cryogenic, ambient, and high-temperature environments. Herein, emphasis is given to hydrogen sensors based on solid oxide electrolytes (operating at high temperatures), in particular oxygen ion and proton conductors. The review is devoted to potentiometric, amperometric, and combined amperometric-potentiometric hydrogen sensors. Experimental results already reported in the international literature are presented and analyzed to reveal the configuration, principle of operation, and the applied solid electrolytes and electrodes of the high-temperature hydrogen sensors. Additionally, an amperometric sensor able to detect hydrogen and steam in atmospheric air through a two-stage procedure is presented and thoroughly discussed. The discussion reveals that high-temperature hydrogen sensors face different challenges in terms of the electrodes and solid electrolytes to be used, depending on the operating principle of each sensor type.
- 19 January 2022
- Published by Elsevier in Electrochimica Acta
- Vol. 409
Selective electro-oxidation of dopamine on Co or Fe supported onto N-doped ketjenblack
- 19 January 2022
- Published by Elsevier in Electrochimica Acta
- Vol. 409
Selective electro-oxidation of dopamine on Co or Fe supported onto N-doped ketjenblack
- Open Access
Cost Effective Synthesis of Graphene Nanomaterials for Non-Enzymatic Electrochemical Sensors for Glucose: A Comprehensive Review
The high conductivity of graphene material (or its derivatives) and its very large surface area enhance the direct electron transfer, improving non-enzymatic electrochemical sensors sensitivity and its other characteristics. The offered large pores facilitate analyte transport enabling glucose detection even at very low concentration values. In the current review paper we classified the enzymeless graphene-based glucose electrocatalysts’ synthesis methods that have been followed into the last few years into four main categories: (i) direct growth of graphene (or oxides) on metallic substrates, (ii) in-situ growth of metallic nanoparticles into graphene (or oxides) matrix, (iii) laser-induced graphene electrodes and (iv) polymer functionalized graphene (or oxides) electrodes. The increment of the specific surface area and the high degree reduction of the electrode internal resistance were recognized as their common targets. Analyzing glucose electrooxidation mechanism over Cu- Co- and Ni-(oxide)/graphene (or derivative) electrocatalysts, we deduced that glucose electrochemical sensing properties, such as sensitivity, detection limit and linear detection limit, totally depend on the route of the mass and charge transport between metal(II)/metal(III); and so both (specific area and internal resistance) should have the optimum values.
Open AccessCost Effective Synthesis of Graphene Nanomaterials for Non-Enzymatic Electrochemical Sensors for Glucose: A Comprehensive Review
The high conductivity of graphene material (or its derivatives) and its very large surface area enhance the direct electron transfer, improving non-enzymatic electrochemical sensors sensitivity and its other characteristics. The offered large pores facilitate analyte transport enabling glucose detection even at very low concentration values. In the current review paper we classified the enzymeless graphene-based glucose electrocatalysts’ synthesis methods that have been followed into the last few years into four main categories: (i) direct growth of graphene (or oxides) on metallic substrates, (ii) in-situ growth of metallic nanoparticles into graphene (or oxides) matrix, (iii) laser-induced graphene electrodes and (iv) polymer functionalized graphene (or oxides) electrodes. The increment of the specific surface area and the high degree reduction of the electrode internal resistance were recognized as their common targets. Analyzing glucose electrooxidation mechanism over Cu- Co- and Ni-(oxide)/graphene (or derivative) electrocatalysts, we deduced that glucose electrochemical sensing properties, such as sensitivity, detection limit and linear detection limit, totally depend on the route of the mass and charge transport between metal(II)/metal(III); and so both (specific area and internal resistance) should have the optimum values.
- 1 July 2021
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 893, 115289
Emerging materials for the electrochemical detection of COVID-19
- 1 July 2021
- Published by Elsevier in Journal of Electroanalytical Chemistry
- Vol. 893, 115289
Emerging materials for the electrochemical detection of COVID-19
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- No. 64,p. 2079
Me-N-C (Me= Fe, Co) Electrocatalysts with EDTA-Derived N for Dopamine Electrochemical Detection
Neurotransmitters are chemical transporters that exchange signals between neurons and other cells. Measuring their concentrations in vivo is a very challenging procedure, firstly because the extracellular concentrations of neurotransmitters are very low and can change rapidly and secondly because they co-exist with many electroactive neurochemicals in the brain, interfering the neurotransmitters detection. Dopamine (DA) is a catecholamine, modulating many parts of brain circuitry. Abnormal levels of DA are associated with neurological disorders such as schizophrenia, Alzheimer’s and Parkinson’s diseases. Herein, we synthesized low-cost electrocatalysts using a template-free synthesis method with ethylene diamine tetra acetic acid (EDTA)-nitrogen precursor, carbon substrate and Fe or Co nanoparticles. Both electrocatalysts were investigated towards dopamine oxidation reaction. In the figure below, the amperometric response curves of Co-kb-N /GCE (A) to continuous addition of 1 mM DA (red) and 10 mM DA (pink) are presented, with 1100 rpm in 0.1 M KOH (pH=13) at -0.05 and -0.15 V vs. Ag/AgCl, respectively. Additionally, plots of current versus DA concentration and the corresponding linear fitting after the addition of 1 mM DA (Bi) and 10 mM DA (Bii) solution are depicted. Co-kb-N exhibited the most promising behavior, with three linear ranges: 0.1- 0.41 mM, 1- 3.55 mM, 3.75- 4.74 mM and 0.11, 0.48, 2.58 mM limit of detection, as well as 871.4, 571.3, 105.7 μA mM-1 cm-2 sensitivity, with R2 0.99, 0.98, 0.95, respectively. Figure 1
- 30 May 2021
- Published by The Electrochemical Society in ECS Meeting Abstracts
- No. 64,p. 2079
Me-N-C (Me= Fe, Co) Electrocatalysts with EDTA-Derived N for Dopamine Electrochemical Detection
Neurotransmitters are chemical transporters that exchange signals between neurons and other cells. Measuring their concentrations in vivo is a very challenging procedure, firstly because the extracellular concentrations of neurotransmitters are very low and can change rapidly and secondly because they co-exist with many electroactive neurochemicals in the brain, interfering the neurotransmitters detection. Dopamine (DA) is a catecholamine, modulating many parts of brain circuitry. Abnormal levels of DA are associated with neurological disorders such as schizophrenia, Alzheimer’s and Parkinson’s diseases. Herein, we synthesized low-cost electrocatalysts using a template-free synthesis method with ethylene diamine tetra acetic acid (EDTA)-nitrogen precursor, carbon substrate and Fe or Co nanoparticles. Both electrocatalysts were investigated towards dopamine oxidation reaction. In the figure below, the amperometric response curves of Co-kb-N /GCE (A) to continuous addition of 1 mM DA (red) and 10 mM DA (pink) are presented, with 1100 rpm in 0.1 M KOH (pH=13) at -0.05 and -0.15 V vs. Ag/AgCl, respectively. Additionally, plots of current versus DA concentration and the corresponding linear fitting after the addition of 1 mM DA (Bi) and 10 mM DA (Bii) solution are depicted. Co-kb-N exhibited the most promising behavior, with three linear ranges: 0.1- 0.41 mM, 1- 3.55 mM, 3.75- 4.74 mM and 0.11, 0.48, 2.58 mM limit of detection, as well as 871.4, 571.3, 105.7 μA mM-1 cm-2 sensitivity, with R2 0.99, 0.98, 0.95, respectively. Figure 1