BLBarsha Lal

Barsha Lal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Barsha Lal has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Repeatability of retinal and choroidal optical coherence tomography angiography indices in healthy children and young adults

    by Barsha Lal, David Alonso‐Caneiro, Scott A. Read, Andrew Carkeet

    Purpose: To evaluate the repeatability of retinal and choroidal optical coherence tomography angiography (OCT‐A) indices among healthy children and compare it to healthy young adults. Methods: This prospective study captured 3 mm × 3 mm and 6 mm × 6 mm macular OCT‐A scans including superficial and deep retinal layers, choriocapillaris and deep choroid over two visits, 1 week apart at approximately the same time of day, for 22 healthy adults (18–30 years) and 21 children (6–15 years). Magnification and projection‐artefact corrected indices extracted using a custom image analysis program and individual biometry were compared between visits using Bland–Altman analysis and intraclass correlation (ICC). Retinal indices included foveal avascular zone metrics, perfusion and vessel density and choroidal indices included choriocapillaris flow deficit metrics and deep choroid perfusion density, in the foveal, parafoveal and perifoveal regions. Repeatability between adults and children was compared with F ‐test. Results: Bland–Altman analysis showed that the mean differences between repeated OCT‐A indices were not significantly different from zero for either of the zones, layers and scan sizes in the two age groups ( p > 0.05) except for foveal vessel density and foveal avascular zone perimeter ( p = 0.04 for both) of 6‐mm‐deep retinal layer scans. The ICC ranged between 0.67 and 0.99. Significantly higher variability between visits ( p < 0.05) in the indices was noted among adults than children, especially for choroidal indices of larger scan size. Conclusion: The retinal and choroidal OCT‐A indices in the foveal, parafoveal and perifoveal zones were repeatable in healthy children except for the foveal vessel density and foveal avascular zone perimeter of the 6‐mm‐deep retinal layer, which exhibited statistically borderline differences between visits. The adult group showed more variability between visits compared to children, especially in the larger scan size for choroidal OCT‐A indices.


  • Open Access

    Vision screening using the Acuidrive device

    by David A Atchison, Barsha Lal, Katrina L Schmid, Bianca Romeo, Andrew Carkeet

    Clinical relevanceUnderstanding devices used for vision screening, including their potential utilisation and validity, will facilitate proper utilisation of this technology.BackgroundThe Acuidrive is a self-illuminated, hand-held, visual acuity screening device intended for use in policing, with visual acuity assessed roadside to identify drivers who may not meet vision standards for driving. The target is presented binocularly at 24 cm, and +4.00 D lenses eliminate the accommodation requirement. This study investigates its validity and applicability relative to the Early Treatment of Diabetic Retinopathy Study (ETDRS) chart.MethodsThere were 36 participants, half younger adults aged 18-30 years and half older adults aged 50-70 years. The subjects underwent binocular visual acuity testing using the Acuidrive device and an ETDRS chart displayed on a monitor. Eyes were corrected for distance using lenses in a trial frame, and additional trial lenses provided four blur levels: zero, +0.50 DS, +1.00 DS and +1.50 DS. Luminances for the devices were similar at approximately 100 cd/m2. ETDRS chart measurements were conducted both with room lighting on and off.ResultsThe Acuidrive device underestimated the ETDRS visual acuity across all blur levels, with mean differences of 0.24 +/- 0.07 logMAR and 0.18 +/- 0.10 logMAR for room lights on and off, respectively. To predict ETDRS visual acuity of poorer than 0.34 logMAR (6/12=), a screening level of 0.50 logMAR (6/19) with the Acuidrive device provided high sensitivity and specificity (86% and 79% with lights-on, and 85% and 78% with lights-off). Visual acuity was better for the older group than the younger group by approximately 0.10 logMAR.ConclusionThere was an offset of 0.2 logMAR (two lines) between visual acuity measures for the Acuidrive device and an ETDRS chart. The Acuidrive device has the potential to be a viable screening tool with refinement to its construction.


  • Open Access

    Changes in retinal and choroidal optical coherence tomography angiography indices among young adults and children over 1 year

    by Barsha Lal, David Alonso-Caneiro, Scott A Read, Andrew Carkeet

    Clinical relevance Optical coherence tomography angiography (OCT-A) indices are likely to change across time and optometrists should be aware of the variability expected during childhood development and in healthy adults.Background Cross-sectional studies have shown that OCT-A indices are associated with age in adults and children. The aim of this study is to investigate longitudinal changes in retinal and choroidal OCT-A indices over 1 year among healthy children and young adults.Methods This prospective longitudinal study captured macular OCT-A and OCT scans, and biometry measures at baseline and 1-year follow-up for 22 adults (18-30 years; -6.87 to +0.37 D) and 21 children (6-15 years; -5.75 to +0.25 D). Superficial and deep retinal layer, choriocapillaris and deep choroidal en face OCT-A images were analysed to extract magnification-corrected vascular indices in foveal, parafoveal and perifoveal regions. The retinal indices included foveal avascular zone metrics, perfusion, and vessel density. Flow deficit number, size, and density were extracted from choriocapillaris and perfusion density from deep choroid. Associations between annual changes in the OCT-A indices and axial length and baseline refraction were also studied.Results Among children, significant reductions were noted only in parafoveal superficial retinal and foveal and perifoveal deep retinal layer indices over 1 year (p < 0.05). Choroidal OCT-A indices in children and both retinal and choroidal OCT-A indices in adults did not show significant changes. Myopia was associated with a larger reduction in the perifoveal retinal OCT-A indices in children, and with increases in sub-foveal and sub-parafoveal choroidal indices in adults. There were associations between OCT-A indices and axial length changes but differently in adults and children.Conclusions Significant changes were noted in retinal OCT-A indices over 1 year among children but not adults. In comparison, choroidal OCT-A indices in adults and children showed a stable morphology over this period of time.


  • Open Access

    Diurnal changes in choroidal optical coherence tomography angiography indices over 24 hours in healthy young adults

    by Barsha Lal, David Alonso-Caneiro, Scott A. Read, Andrew Carkeet

    This prospective study investigated the magnitude and pattern of variation in choroidal optical coherence tomography angiography (OCT-A) indices every 4 h over 24 h in healthy young myopic (n = 24) and non-myopic (n = 20) adults. Choriocapillaris and deep choroid en-face images from macular OCT-A scans were analysed from each session to extract magnification-corrected vascular indices including choriocapillaris flow deficit number, size and density and deep choroid perfusion density in the sub-foveal, sub-parafoveal, and sub-perifoveal regions. Choroidal thickness was also obtained from structural OCT scans. Significant variations over 24 h (P < 0.05) were observed in most of the choroidal OCT-A indices excluding sub-perifoveal flow deficit number, with peaks observed between 2 to 6 AM. For myopes, peaks occurred significantly earlier (3–5 h), and the diurnal amplitude was significantly greater for sub-foveal flow deficit density (P = 0.02) and deep choroidal perfusion density (P = 0.03) compared with non-myopes. Choroidal thickness also showed significant diurnal changes (P < 0.05) with peaks between 2 to 4 AM. Significant correlations were found between diurnal amplitudes or acrophases of choroidal OCT-A indices and choroidal thickness, intraocular pressure, and systemic blood pressure. This provides the first comprehensive diurnal assessment of choroidal OCT-A indices over 24 h.


  • Open Access

    Awareness and knowledge of diabetic retinopathy and associated factors in Goa: A hospital-based cross-sectional study

    by Dinesh Venugopal, Barsha Lal, Shawnicka Fernandes, Deepali Gavde

    Purpose: To assess the awareness and knowledge about diabetic retinopathy (DR) and associated factors among patients visiting the tertiary health center in Goa. Methods: A cross-sectional descriptive study was conducted using a standard predesigned and pretested closed-ended structured questionnaire to assess the awareness, knowledge, attitude and practice about DR among patients visiting a tertiary health center. Results: Three hundred and fifty-eight subjects participated in the study. Only 125 (34.9% [95% CI: 30.0–40.1]) subjects were aware of DR and 122 (34.1% [95% CI: 29.2–39.2]) had adequate knowledge about DR. Awareness and knowledge of DR were significantly high among the subjects who completed college level of education (66.7%, OR = 2.78; 95% CI: 1.73–4.48, P < 0.001 and 55.9%, OR = 3.92; 95% CI: 2.41–6.38, P < 0.001) and who spoke English (52.5%, OR = 3.37; 95% CI: 2.14–5.30, P < 0.001 and 50.4%, OR = 3.26; 95% CI: 2.07–5.14, P < 0.001). Christians reported better knowledge about DR compared to other religions (48.8%, OR = 2.27; 95% CI: 1.38–3.75, P = 0.005). Negative association was noted between the knowledge of DR and presence of diabetes (29.4%, OR = 0.64; 95% CI: 0.41–0.99, P = 0.048). The practice pattern was strongly associated (OR = 7.47; 95% CI: 4.51–12.38, P < 0.001) with the knowledge of DR. Attitude was not influenced by any of the factors. Conclusion: We found that awareness and knowledge about DR were unsatisfactory; literacy contributed significantly toward it. These findings also suggest that there is an immediate need to enhance the awareness and knowledge of diabetic eye diseases in order to reduce the burden of visual impairment.


  • Open Access

    Awareness and knowledge on eye donation among Allied Health Sciences, medical, and nursing students in Goa

    by Barsha Lal, Ugam Usgaonkar, Harshada Narvekar, Dinesh Venugopal

    Purpose: To assess the awareness and knowledge on eye donation among students of Allied Health Sciences (AHS), medical, and nursing. Methods: A cross-sectional descriptive study was conducted using a standard predesigned and pretested closed-ended structured questionnaire based on eye donation to obtain information about awareness and knowledge from AHS, medical, and nursing students of Goa. Results: Three hundred and forty participants participated in the study. The majority of the participants [97.9% (95% CI: 95.8-99.2)] were aware of the existence of eye donation. Mass media (62.9%) was the foremost source of information. However, only 145 [42.6% (95% CI: 37.3-48.1)] participants were willing to donate their eyes. AHS, medical, and nursing students stood apart significantly in their awareness and knowledge. Only 60 [17.6% (95% CI: 13.7-22.1)] participants were aware that the whole eye can be removed from the donor while 215 [63.2% (95% CI: 57.9-68.4)] were wrongly aware that the cornea can be removed separately. Awareness about eye donation was not associated with willingness to donate eyes. Conclusions: Although awareness regarding eye donation was satisfactory, there was lack of willingness to donate eyes. There is a need to bridge the gap between eye bank and donors. Copyright (c) 2018, Iranian Society of Ophthalmology. Production and hosting by Elsevier B.V.