Megan M. Foley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Megan M. Foley has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Anjan Bose
School of Electrical Engineering and Computer Science, Washington State University, Pullman, WA, USA
1 shared publication Fernando Moreira
Gentueri, Inc., Verona, Wisconsin, USA
1 shared publication- Georgia Williams
Forensic Science Program, George Mason University
1 shared publication Gerwald Koehler
Department of Biochemistry & Microbiology Oklahoma State University Tulsa Oklahoma USA
1 shared publicationJarrad R. Wagner
School of Forensic Sciences Oklahoma State University Tulsa Oklahoma USA
1 shared publicationJun Fu
School of Forensic Sciences Oklahoma State University Tulsa Oklahoma USA
1 shared publication
Latest Publications
- 20 March 2024
- Published by Wiley in Journal of Forensic Sciences
- Vol. 69 (3) , 825-835
An exploratory view into allelic drop‐out of sequenced autosomal STRs
As massively parallel sequencing is implemented in forensic genetics, an understanding of sequence data must accompany these advancements, that is, accurate modeling of data for proper statistical analysis. Allelic drop‐out, a common stochastic effect seen in genetic data, is often modeled in statistical analysis of STR results. This proof‐of‐concept study sequenced several serial dilutions of a standard sample ranging from 4 ng to 7.82 pg to evaluate allelic drop‐out trends on a select panel of autosomal STRs using the ForenSeq™ DNA Signature Prep Kit, Primer Set A on the Illumina MiSeq FGx. Parameters assessed included locus, profile, and run specific information. A majority of the allelic drop‐out occurred in DNA concentrations less than 31.25 pg. Statistical results indicated a need for locus‐specific modeling based on STR descriptors, like simple versus compound repeat patterns. No correlation was seen between average read count of scored alleles and allelic drop‐out at a locus. A statistical correlation was observed between the amount of allelic drop‐out and the starting amount of DNA in a sample, average read count of a sample, and total read count generated on a flow cell. This study supports using common allelic drop‐out factors used in fragment length analysis on sequenced STRs while including additional locus, sample, and run specific information. Results demonstrate multiple factors that can be considered when developing probability of allelic drop‐out models for sequenced autosomal STRs including locus‐specific analysis, total read count of a profile, and total read count sequenced on a flow cell.
- 20 March 2024
- Published by Wiley in Journal of Forensic Sciences
- Vol. 69 (3) , 825-835
An exploratory view into allelic drop‐out of sequenced autosomal STRs
As massively parallel sequencing is implemented in forensic genetics, an understanding of sequence data must accompany these advancements, that is, accurate modeling of data for proper statistical analysis. Allelic drop‐out, a common stochastic effect seen in genetic data, is often modeled in statistical analysis of STR results. This proof‐of‐concept study sequenced several serial dilutions of a standard sample ranging from 4 ng to 7.82 pg to evaluate allelic drop‐out trends on a select panel of autosomal STRs using the ForenSeq™ DNA Signature Prep Kit, Primer Set A on the Illumina MiSeq FGx. Parameters assessed included locus, profile, and run specific information. A majority of the allelic drop‐out occurred in DNA concentrations less than 31.25 pg. Statistical results indicated a need for locus‐specific modeling based on STR descriptors, like simple versus compound repeat patterns. No correlation was seen between average read count of scored alleles and allelic drop‐out at a locus. A statistical correlation was observed between the amount of allelic drop‐out and the starting amount of DNA in a sample, average read count of a sample, and total read count generated on a flow cell. This study supports using common allelic drop‐out factors used in fragment length analysis on sequenced STRs while including additional locus, sample, and run specific information. Results demonstrate multiple factors that can be considered when developing probability of allelic drop‐out models for sequenced autosomal STRs including locus‐specific analysis, total read count of a profile, and total read count sequenced on a flow cell.
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 241-252
Applied Biosystems’ GlobalFiler™ PCR Amplification Kit
The GlobalFiler™ PCR Amplification Kit is one of the most sensitive kits that exist today that makes the PCR amplification of human DNA possible. PCR amplification using this specific kit makes millions of copies of 24 specific target sequences in the DNA, called markers or loci. This kit is a 6-dye, short tandem repeat (STR) multiplex assay kit that has a synthetic mix of primers and single-stranded oligonucleotides that are combined with DNA samples and then subjected to 29 or 30 cycles of denaturing, annealing, and extension, as per laboratory protocol. Methods for instrument operation will vary depending on the thermal cycler instrument model that is used. Nevertheless, the GlobalFiler™ PCR Amplification Kit has proven to be a very useful tool to DNA analysts, amplifying extremely low quantities of DNA, making it possible to detect partial, if not full, genetic profiles from a wide range of sample types. This chapter discusses the typical preparation and PCR amplification of human forensic DNA samples, using the GlobalFiler™ PCR Amplification Kit. Key words GlobalFiler™ PCR Amplification STR DNA polymerase Multiplex Loci CODIS ThermoFisher Forensic Genetics
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 241-252
Applied Biosystems’ GlobalFiler™ PCR Amplification Kit
The GlobalFiler™ PCR Amplification Kit is one of the most sensitive kits that exist today that makes the PCR amplification of human DNA possible. PCR amplification using this specific kit makes millions of copies of 24 specific target sequences in the DNA, called markers or loci. This kit is a 6-dye, short tandem repeat (STR) multiplex assay kit that has a synthetic mix of primers and single-stranded oligonucleotides that are combined with DNA samples and then subjected to 29 or 30 cycles of denaturing, annealing, and extension, as per laboratory protocol. Methods for instrument operation will vary depending on the thermal cycler instrument model that is used. Nevertheless, the GlobalFiler™ PCR Amplification Kit has proven to be a very useful tool to DNA analysts, amplifying extremely low quantities of DNA, making it possible to detect partial, if not full, genetic profiles from a wide range of sample types. This chapter discusses the typical preparation and PCR amplification of human forensic DNA samples, using the GlobalFiler™ PCR Amplification Kit. Key words GlobalFiler™ PCR Amplification STR DNA polymerase Multiplex Loci CODIS ThermoFisher Forensic Genetics
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 53-81
Applied Biosystems™ PrepFiler™ Forensic DNA Extraction Kit (Manual and Semi-automated via AutoMate Express™)
The PrepFiler™ Forensic DNA Extraction Kits allow for optimal genomic DNA isolation and purification from forensic samples through a bind-wash-elute-based technique that can be performed manually or robotically using the Applied Biosystems AutoMate Express™ Forensic DNA Extraction System. The extraction kits come in two formats: the standard kit used for common case type samples, like bodily fluid swabs or stains, and a BTA kit for more challenging evidence sample types that can be submitted for analysis, like bones, teeth, and adhesive-type samples. Both forms of extraction, manual and semi-automated, require an initial manual incubation step using a lysis buffer to release the DNA into solution. If following the semi-automated protocol, the lysate can be purified and eluted on the AutoMate Express™. After lysis, the DNA binds to magnetic beads in the presence of a chaotropic salt and is washed multiple times with an ethanol-based wash buffer to purify the sample and remove potential PCR inhibitors. After removing the wash liquid, elution buffer is added to the tube containing the DNA-bound magnetic beads and heated, which disrupts the bonding between the DNA and beads. The DNA is then concentrated in the final tube and can be moved forward through the DNA analysis workflow. This chapter describes a manual DNA isolation method and the extraction procedures following both manual and robotic methods using the PrepFiler™ chemistries in conjunction with the AutoMate Express™ Forensic DNA Extraction System. Key words DNA Extraction PrepFiler™ PrepFiler™ BTA PrepFiler Express™ PrepFiler Express™ BTA AutoMate Express™ Forensic Genetics Forensic Biology DNA analysis
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 53-81
Applied Biosystems™ PrepFiler™ Forensic DNA Extraction Kit (Manual and Semi-automated via AutoMate Express™)
The PrepFiler™ Forensic DNA Extraction Kits allow for optimal genomic DNA isolation and purification from forensic samples through a bind-wash-elute-based technique that can be performed manually or robotically using the Applied Biosystems AutoMate Express™ Forensic DNA Extraction System. The extraction kits come in two formats: the standard kit used for common case type samples, like bodily fluid swabs or stains, and a BTA kit for more challenging evidence sample types that can be submitted for analysis, like bones, teeth, and adhesive-type samples. Both forms of extraction, manual and semi-automated, require an initial manual incubation step using a lysis buffer to release the DNA into solution. If following the semi-automated protocol, the lysate can be purified and eluted on the AutoMate Express™. After lysis, the DNA binds to magnetic beads in the presence of a chaotropic salt and is washed multiple times with an ethanol-based wash buffer to purify the sample and remove potential PCR inhibitors. After removing the wash liquid, elution buffer is added to the tube containing the DNA-bound magnetic beads and heated, which disrupts the bonding between the DNA and beads. The DNA is then concentrated in the final tube and can be moved forward through the DNA analysis workflow. This chapter describes a manual DNA isolation method and the extraction procedures following both manual and robotic methods using the PrepFiler™ chemistries in conjunction with the AutoMate Express™ Forensic DNA Extraction System. Key words DNA Extraction PrepFiler™ PrepFiler™ BTA PrepFiler Express™ PrepFiler Express™ BTA AutoMate Express™ Forensic Genetics Forensic Biology DNA analysis
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 397-427
Next-Generation Sequencing: ForenSeq™ DNA Signature Prep Kit with the Illumina MiSeq FGx
Sequencing forensic DNA samples that are amplified and prepared with the ForenSeq™ DNA Signature Prep Kit allows for the simultaneous targeting of forensically relevant STR and SNP markers. The MiSeq™ FGx system allows massively parallel sequencing of these markers in a single analysis. The library preparation targets autosomal, Y-, and X-STRs, as well as identity SNPs. The kit can also be used to generate investigative information regarding the DNA contributor by analyzing phenotypic SNPs to predict hair color, eye color, and ancestry SNPs. Through two rounds of amplification, all loci are amplified and tagged with individualizing barcodes for sequencing capture and identification. Using bead-based technology, the libraries are purified by the removal of left-over amplification reagents and then normalized to ensure equal representation of all samples during sequencing. The individual libraries are then pooled for insertion into the MiSeq FGx. The pooled libraries are then added to a pre-packaged cartridge that contains all reagents necessary for optimal sequencing. Libraries are captured on a flow cell and undergo bridge amplification for the generation of individual clusters. Sequencing of each cluster is performed using a Sequence-By-Synthesis technology. The following chapter describes the methodology and process of library preparation of samples using the ForenSeq™ DNA Signature Prep Kit Primer Set A and B. Once completed, the chapter then focuses on the setup of a sequencing run on the MiSeq FGx and the sequencing methodology employed by the instrument. Key words ForenSeq™ DNA Signature Prep Kit MiSeq FGx Forensic DNA Sequencing Next Generation Sequencing Massively Parallel Sequencing STR Sequencing SNP Analysis Phenotypic SNPs Ancestry SNPs
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 397-427
Next-Generation Sequencing: ForenSeq™ DNA Signature Prep Kit with the Illumina MiSeq FGx
Sequencing forensic DNA samples that are amplified and prepared with the ForenSeq™ DNA Signature Prep Kit allows for the simultaneous targeting of forensically relevant STR and SNP markers. The MiSeq™ FGx system allows massively parallel sequencing of these markers in a single analysis. The library preparation targets autosomal, Y-, and X-STRs, as well as identity SNPs. The kit can also be used to generate investigative information regarding the DNA contributor by analyzing phenotypic SNPs to predict hair color, eye color, and ancestry SNPs. Through two rounds of amplification, all loci are amplified and tagged with individualizing barcodes for sequencing capture and identification. Using bead-based technology, the libraries are purified by the removal of left-over amplification reagents and then normalized to ensure equal representation of all samples during sequencing. The individual libraries are then pooled for insertion into the MiSeq FGx. The pooled libraries are then added to a pre-packaged cartridge that contains all reagents necessary for optimal sequencing. Libraries are captured on a flow cell and undergo bridge amplification for the generation of individual clusters. Sequencing of each cluster is performed using a Sequence-By-Synthesis technology. The following chapter describes the methodology and process of library preparation of samples using the ForenSeq™ DNA Signature Prep Kit Primer Set A and B. Once completed, the chapter then focuses on the setup of a sequencing run on the MiSeq FGx and the sequencing methodology employed by the instrument. Key words ForenSeq™ DNA Signature Prep Kit MiSeq FGx Forensic DNA Sequencing Next Generation Sequencing Massively Parallel Sequencing STR Sequencing SNP Analysis Phenotypic SNPs Ancestry SNPs
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 307-328
Likelihood Ratio Calculation Using LRmix Studio
LRmix Studio performs statistical analyses on forensic casework samples by calculating a likelihood ratio (LR) following a semi-continuous, unrestricted approach. The software utilizes a basic probabilistic model allowing the comparison of two alternative hypotheses regarding the evidence profile to include known and/or unknown contributors, for a maximum of a 4-person mixture. Other statistical factors that are included in this model are the incorporation of multiple probability of drop-out values, probability of drop-in, a correction factor for population substructure, assumed contributor inclusion, and inclusion of an unknown relative in the defense hypothesis. A range of plausible probability of drop-out values can be calculated for various contributors and hypotheses based on a Monte Carlo probability method and included in the likelihood ratio calculation. The software also includes several ways to test the validity and robustness of the probabilistic model. A sensitivity analysis can be performed by calculating likelihood ratios for the given profile against a range of drop-out values. Additionally, a non-contributor test can be performed on the crime scene sample and the chosen LR parameters to test the robustness of the model. This can give a point of comparison of the likelihood ratio generated for the person of interest (POI) compared to “random man” profiles generated from uploaded allelic frequencies. Finally, the analysis can be printed in a well-structured and user-friendly report that includes all analysis parameters. Within this chapter, the reader will learn the steps to calculate a likelihood ratio using the semi-continuous software, LRmix Studio. Additional tools supplied through the software will also be explained and demonstrated. Key words Likelihood ratio LRmix Studio Mixture interpretation Forensic statistical analysis Forensic genetics Probability of drop-out Probabilistic modeling
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 307-328
Likelihood Ratio Calculation Using LRmix Studio
LRmix Studio performs statistical analyses on forensic casework samples by calculating a likelihood ratio (LR) following a semi-continuous, unrestricted approach. The software utilizes a basic probabilistic model allowing the comparison of two alternative hypotheses regarding the evidence profile to include known and/or unknown contributors, for a maximum of a 4-person mixture. Other statistical factors that are included in this model are the incorporation of multiple probability of drop-out values, probability of drop-in, a correction factor for population substructure, assumed contributor inclusion, and inclusion of an unknown relative in the defense hypothesis. A range of plausible probability of drop-out values can be calculated for various contributors and hypotheses based on a Monte Carlo probability method and included in the likelihood ratio calculation. The software also includes several ways to test the validity and robustness of the probabilistic model. A sensitivity analysis can be performed by calculating likelihood ratios for the given profile against a range of drop-out values. Additionally, a non-contributor test can be performed on the crime scene sample and the chosen LR parameters to test the robustness of the model. This can give a point of comparison of the likelihood ratio generated for the person of interest (POI) compared to “random man” profiles generated from uploaded allelic frequencies. Finally, the analysis can be printed in a well-structured and user-friendly report that includes all analysis parameters. Within this chapter, the reader will learn the steps to calculate a likelihood ratio using the semi-continuous software, LRmix Studio. Additional tools supplied through the software will also be explained and demonstrated. Key words Likelihood ratio LRmix Studio Mixture interpretation Forensic statistical analysis Forensic genetics Probability of drop-out Probabilistic modeling
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 367-396
Rapid DNA Profile Development with Applied Biosystems RapidHIT™ ID System
The RapidHIT™ ID System by Applied Biosystems allows the generation of a CODIS compatible STR profile in 90 min. The preloaded cartridges, fully automated workflow, and user-friendly computer interface allow for quick and simple single sample processing both in the laboratory and outside by non-laboratory personnel, like law enforcement officers. DNA processing utilizes a direct amplification workflow to generate an STR profile targeting the CODIS or ESS core loci. In conjunction with the RapidLINK™ Software, the system performs an initial analysis, flagging any profiles that do not meet single-source full profile parameters. Additionally, the RapidLINK™ allows for users to manage a multi-instrument/multi-location Rapid DNA system and view results in real-time. This gives users off-site the ability to track and even analyze results. The system allows for rapid reference sample analysis in locations like booking stations and national or border security agencies to obtain quick feedback of database hits for investigative leads while the subject is still in custody. RapidHIT™ ID DNA systems can also be set up at sites to aid in victim identification during mass disasters. The following chapter describes the process of generating a forensic DNA profile using the RapidHIT™ ID instrumentation from start to finish. Additionally, basic use and analysis using the RapidLINK™ and GeneMarker™ HID software is included. Key words Rapid DNA RapidHIT™ ID RapidLINK™ GeneMarker™ HID Rapid STR Analysis FBI DISC GlobalFiler™ Express RapidINTEL™ NGM SElect™ Express
- 14 July 2023
- Published by Springer Nature
- Vol. 2685, 367-396
Rapid DNA Profile Development with Applied Biosystems RapidHIT™ ID System
The RapidHIT™ ID System by Applied Biosystems allows the generation of a CODIS compatible STR profile in 90 min. The preloaded cartridges, fully automated workflow, and user-friendly computer interface allow for quick and simple single sample processing both in the laboratory and outside by non-laboratory personnel, like law enforcement officers. DNA processing utilizes a direct amplification workflow to generate an STR profile targeting the CODIS or ESS core loci. In conjunction with the RapidLINK™ Software, the system performs an initial analysis, flagging any profiles that do not meet single-source full profile parameters. Additionally, the RapidLINK™ allows for users to manage a multi-instrument/multi-location Rapid DNA system and view results in real-time. This gives users off-site the ability to track and even analyze results. The system allows for rapid reference sample analysis in locations like booking stations and national or border security agencies to obtain quick feedback of database hits for investigative leads while the subject is still in custody. RapidHIT™ ID DNA systems can also be set up at sites to aid in victim identification during mass disasters. The following chapter describes the process of generating a forensic DNA profile using the RapidHIT™ ID instrumentation from start to finish. Additionally, basic use and analysis using the RapidLINK™ and GeneMarker™ HID software is included. Key words Rapid DNA RapidHIT™ ID RapidLINK™ GeneMarker™ HID Rapid STR Analysis FBI DISC GlobalFiler™ Express RapidINTEL™ NGM SElect™ Express
- 17 May 2021
- Published by SAGE Publications in Genetic Testing and Molecular Biomarkers
- Vol. 25 (5) , 376-380
Evaluation of Maximum DNA Yield from a New Noninvasive Buccal Collection Device Following Various Extraction Protocols
Background: As the demand in genetic testing increases, various fields look toward collection methods that are noninvasive and efficient in recovering deoxyribonucleic acid (DNA) for testing that will allow for high first-pass success rates. Objective: Two extraction methods (PrepFiler™ Express Forensic Extraction and the Maxwell ® RSC Buccal Swab DNA Kits) were optimized to increase DNA yield from a buccal cell collection device (Gentueri's CollectEject™ Swab). Materials and Methods: Buccal swabs were processed under varying incubation parameters using a forensic workflow. The PrepFiler method was adjusted to test longer incubation times and more aggressive agitation. The Maxwell method was adjusted to test incubation temperatures and duration. Results: Quantitative results showed that increased agitation can yield more DNA through the PrepFiler extraction, but longer incubation times did not increase DNA recovery. The results from the Maxwell study showed no significant difference between incubation temperatures or times. Conclusions: The results indicate that various applied genetic fields can utilize a noninvasive, simple collection method using the CollectEject device in conjunction with extraction methods already implemented in laboratories to collect 5000 ng of DNA or greater from a buccal cell collection.
- 17 May 2021
- Published by SAGE Publications in Genetic Testing and Molecular Biomarkers
- Vol. 25 (5) , 376-380
Evaluation of Maximum DNA Yield from a New Noninvasive Buccal Collection Device Following Various Extraction Protocols
Background: As the demand in genetic testing increases, various fields look toward collection methods that are noninvasive and efficient in recovering deoxyribonucleic acid (DNA) for testing that will allow for high first-pass success rates. Objective: Two extraction methods (PrepFiler™ Express Forensic Extraction and the Maxwell ® RSC Buccal Swab DNA Kits) were optimized to increase DNA yield from a buccal cell collection device (Gentueri's CollectEject™ Swab). Materials and Methods: Buccal swabs were processed under varying incubation parameters using a forensic workflow. The PrepFiler method was adjusted to test longer incubation times and more aggressive agitation. The Maxwell method was adjusted to test incubation temperatures and duration. Results: Quantitative results showed that increased agitation can yield more DNA through the PrepFiler extraction, but longer incubation times did not increase DNA recovery. The results from the Maxwell study showed no significant difference between incubation temperatures or times. Conclusions: The results indicate that various applied genetic fields can utilize a noninvasive, simple collection method using the CollectEject device in conjunction with extraction methods already implemented in laboratories to collect 5000 ng of DNA or greater from a buccal cell collection.
- 1 January 1990
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 5 (4) , 1400-1406
A real time power system simulation laboratory environment
- 1 January 1990
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 5 (4) , 1400-1406
A real time power system simulation laboratory environment