Franziska Schrank
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Franziska Schrank has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Volker Schulz
RWTH Aachen University
5 shared publications - Harald Radermacher
RWTH Aachen University
4 shared publications - Qibin Wang
Zhengzhou University
3 shared publications - Shouping Zhu
Xidian University
3 shared publications - Lei Li
School of Life Science and Technology, Xidian University, Xian, China
2 shared publications - Yu Zeng
School of Life Science and Technology, Xidian University, Xian, China
2 shared publications
Latest Publications
- Open Access
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Evaluation of a Mouse-Sized Radial Gradiometer Receive Coil for Magnetic Particle Imaging
Magnetic particle imaging (MPI) uses the nonlinear magnetization response of superparamagnetic iron-oxide nanoparticles (SPIONs) for fast, sensitive, and quantitative imaging of SPION distributions in biological systems. However, the SPIONs’ signal is overshadowed by the much larger excitation signal, necessitating the use of gradiometric receive coils, which often suffer from reduced homogeneity and adverse cross-talk with the MPI system. We develop a new high-sensitivity receive coil by extending the radial geometric design for gradiometers, where cancellation coil parts have larger diameter, thus providing stronger coupling to the excitation field. This enables us to both reduce cancellation coil windings and increase the winding density of the smaller-diameter pick-up coil part, achieving greater sensitivity and homogeneity. The developed mouse-sized receiveonly (Rx) coil is optimized for the use in Bruker’s preclinical MPI scanner and its performance is compared to the scanner’s built-in transmit-receive (TxRx) coil. Power transfer measurements and the particle signal-to-noise ratio show a sensitivity improvement of (20 – 21) dB in the range of (102 – 103) kHz compared to the TxRx coil. The sensitivity varies within ±9% across the field-ofview, providing higher homogeneity than standard gradiometers. With reconstructed images of SPION dilutions using perimag® particles, we show an iron limit-of-detection of 8.5 ng for the novel Rx coil, which is a ten-fold improvement compared to the original TxRx coil. The high sensitivity and homogeneity provided by the Rx coil will advance the application of MPI in preclinical research by enabling the visualization and quantification of lower iron concentrations, as well as providing higher spatial and temporal resolution.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Open AccessEvaluation of a Mouse-Sized Radial Gradiometer Receive Coil for Magnetic Particle Imaging
Magnetic particle imaging (MPI) uses the nonlinear magnetization response of superparamagnetic iron-oxide nanoparticles (SPIONs) for fast, sensitive, and quantitative imaging of SPION distributions in biological systems. However, the SPIONs’ signal is overshadowed by the much larger excitation signal, necessitating the use of gradiometric receive coils, which often suffer from reduced homogeneity and adverse cross-talk with the MPI system. We develop a new high-sensitivity receive coil by extending the radial geometric design for gradiometers, where cancellation coil parts have larger diameter, thus providing stronger coupling to the excitation field. This enables us to both reduce cancellation coil windings and increase the winding density of the smaller-diameter pick-up coil part, achieving greater sensitivity and homogeneity. The developed mouse-sized receiveonly (Rx) coil is optimized for the use in Bruker’s preclinical MPI scanner and its performance is compared to the scanner’s built-in transmit-receive (TxRx) coil. Power transfer measurements and the particle signal-to-noise ratio show a sensitivity improvement of (20 – 21) dB in the range of (102 – 103) kHz compared to the TxRx coil. The sensitivity varies within ±9% across the field-ofview, providing higher homogeneity than standard gradiometers. With reconstructed images of SPION dilutions using perimag® particles, we show an iron limit-of-detection of 8.5 ng for the novel Rx coil, which is a ten-fold improvement compared to the original TxRx coil. The high sensitivity and homogeneity provided by the Rx coil will advance the application of MPI in preclinical research by enabling the visualization and quantification of lower iron concentrations, as well as providing higher spatial and temporal resolution.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (3) , 1-8
Enhancing the Sensitivity and Detection Depth of a Single-Sided Magnetic Particle Spectrometer Using Ferrite Cores
Magnetic particle spectrometers (MPS), first developed in relation to magnetic particle imaging (MPI) since its introduction in 2005, have been widely applied in biomedical detection and the evaluation of magnetic nanoparticle performance in MPI. Their high sensitivity, low cost, and portability make MPS an essential tool for these applications. However, traditional MPS devices are limited by their enclosed measurement chambers, which restrict their application to solutions placed in small test tubes. Therefore, developing MPS devices that are not constrained by the size of the subject is crucial for clinical applications. Single-sided MPS devices, which concentrate the coils on one side, are not restricted by the size of the object being measured, making them directly applicable to clinical research. However, single-sided MPS devices are currently limited in terms of detection depth and sensitivity due to the rapid attenuation of the magnetic field with distance. To address this issue, in this work, we propose incorporating a soft magnetic core (Mn-Zn ferrite) into the single-sided MPS to enhance the magnetic flux density of the excitation field, thereby increasing detection depth. Additionally, we introduce a surface receiving coil design to replace the traditional solenoidal receiving coil, further improving sensitivity. The results demonstrate that the sensitivity increases by approximately ten times, and the detection depth is doubled.
- 28 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 61 (3) , 1-8
Enhancing the Sensitivity and Detection Depth of a Single-Sided Magnetic Particle Spectrometer Using Ferrite Cores
Magnetic particle spectrometers (MPS), first developed in relation to magnetic particle imaging (MPI) since its introduction in 2005, have been widely applied in biomedical detection and the evaluation of magnetic nanoparticle performance in MPI. Their high sensitivity, low cost, and portability make MPS an essential tool for these applications. However, traditional MPS devices are limited by their enclosed measurement chambers, which restrict their application to solutions placed in small test tubes. Therefore, developing MPS devices that are not constrained by the size of the subject is crucial for clinical applications. Single-sided MPS devices, which concentrate the coils on one side, are not restricted by the size of the object being measured, making them directly applicable to clinical research. However, single-sided MPS devices are currently limited in terms of detection depth and sensitivity due to the rapid attenuation of the magnetic field with distance. To address this issue, in this work, we propose incorporating a soft magnetic core (Mn-Zn ferrite) into the single-sided MPS to enhance the magnetic flux density of the excitation field, thereby increasing detection depth. Additionally, we introduce a surface receiving coil design to replace the traditional solenoidal receiving coil, further improving sensitivity. The results demonstrate that the sensitivity increases by approximately ten times, and the detection depth is doubled.
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (4) , 1878-1889
Single-Sided Magnetic Particle Imaging Device With Offset Field Based Spatial Encoding
Single-sided Magnetic Particle Imaging (MPI) devices enable easy imaging of areas outside the MPI device, allowing objects of any size to be imaged and improving clinical applicability. However, current single-sided MPI devices face challenges in generating high-gradient selection fields and experience a decrease in gradient strength with increasing detection depth, which limits the detection depth and resolution. We introduce a novel spatial encoding method. This method combines high-frequency alternating excitation fields with variable offset fields, leveraging the inherent characteristic of single-sided MPI devices where the magnetic field strength attenuates with distance. Consequently, the harmonic signals of particle responses at different spatial positions vary. By manipulating multiple offset fields, we correlate the nonlinear harmonic responses of magnetic particles with spatial position data. In this work, we employed an image reconstruction using a system matrix approach, which takes into account the spatial distribution of the magnetic field during the movement of the device within the field of view. Our proposed encoding approach eliminates the need for the classical selection field and directly links the spatial resolution to the strength and spatial distribution of the magnetic field, thus reducing the dependency of resolution on selection field gradients strength. We have demonstrated the feasibility of the proposed method through simulations and phantom measurements.
- 30 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 44 (4) , 1878-1889
Single-Sided Magnetic Particle Imaging Device With Offset Field Based Spatial Encoding
Single-sided Magnetic Particle Imaging (MPI) devices enable easy imaging of areas outside the MPI device, allowing objects of any size to be imaged and improving clinical applicability. However, current single-sided MPI devices face challenges in generating high-gradient selection fields and experience a decrease in gradient strength with increasing detection depth, which limits the detection depth and resolution. We introduce a novel spatial encoding method. This method combines high-frequency alternating excitation fields with variable offset fields, leveraging the inherent characteristic of single-sided MPI devices where the magnetic field strength attenuates with distance. Consequently, the harmonic signals of particle responses at different spatial positions vary. By manipulating multiple offset fields, we correlate the nonlinear harmonic responses of magnetic particles with spatial position data. In this work, we employed an image reconstruction using a system matrix approach, which takes into account the spatial distribution of the magnetic field during the movement of the device within the field of view. Our proposed encoding approach eliminates the need for the classical selection field and directly links the spatial resolution to the strength and spatial distribution of the magnetic field, thus reducing the dependency of resolution on selection field gradients strength. We have demonstrated the feasibility of the proposed method through simulations and phantom measurements.
- Open Access
- 28 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (9) , 09NT01
RF shielding materials for highly-integrated PET/MRI systems
Integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) into a simultaneous device calls for adaptations of the radio frequency (RF) shielding concept. Conventional PET module housings fully encase the entire PET detector to reduce mutual interference. Excluding passive components, i.e. scintillators, from the housings, offers integration advantages, e.g. by reducing the overall housing volume or utilizing bigger scintillators. However, locating the scintillator outside of the RF shielding requires an optically transparent RF shielding interface between the scintillators and the photodetector to close the aperture. Therefore, a careful evaluation and selection of RF materials is essential to ensure an excellent PET/MRI system performance. To this end, we examined 10 materials (coated glasses, coated foils, meshes). The shielding effectiveness (SE) was evaluated at 100 and 300 MHz. PET performance was tested for single event registration and coincident events by integrating the material into the PET detector stack between the digital silicon photomultiplier photodetector array and one-to-one coupled scintillator. We determined photon attenuation (PA), energy resolution (dE/E), and coincidence resolving time (CRT) and compared to reference measurements for each material group. MRI compatibility was assessed by analyzing the material influence on the main magnetic field (B 0 ) homogeneity. The coated glasses and foils exhibited SEs of up to 25 dB at 300 MHz. Both had a PA < 23% with dE/E and CRT comparable to the reference measurements, and no measurable impact on the B 0 field was registered. The meshes exhibited higher SEs up to 56 dB, but also a PA > 58% with a higher impact on dE/E and CRT. Only one mesh affected B 0 homogeneity. Overall, we recommend the coated foil HS 9400 for integration concepts as it exhibited a good performance with SE = 25 dB, PA = 22%, resulting in a PET performance of dE/E = 12% and CRT = 274 ps.
- 28 April 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (9) , 09NT01
Open AccessRF shielding materials for highly-integrated PET/MRI systems
Integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) into a simultaneous device calls for adaptations of the radio frequency (RF) shielding concept. Conventional PET module housings fully encase the entire PET detector to reduce mutual interference. Excluding passive components, i.e. scintillators, from the housings, offers integration advantages, e.g. by reducing the overall housing volume or utilizing bigger scintillators. However, locating the scintillator outside of the RF shielding requires an optically transparent RF shielding interface between the scintillators and the photodetector to close the aperture. Therefore, a careful evaluation and selection of RF materials is essential to ensure an excellent PET/MRI system performance. To this end, we examined 10 materials (coated glasses, coated foils, meshes). The shielding effectiveness (SE) was evaluated at 100 and 300 MHz. PET performance was tested for single event registration and coincident events by integrating the material into the PET detector stack between the digital silicon photomultiplier photodetector array and one-to-one coupled scintillator. We determined photon attenuation (PA), energy resolution (dE/E), and coincidence resolving time (CRT) and compared to reference measurements for each material group. MRI compatibility was assessed by analyzing the material influence on the main magnetic field (B 0 ) homogeneity. The coated glasses and foils exhibited SEs of up to 25 dB at 300 MHz. Both had a PA < 23% with dE/E and CRT comparable to the reference measurements, and no measurable impact on the B 0 field was registered. The meshes exhibited higher SEs up to 56 dB, but also a PA > 58% with a higher impact on dE/E and CRT. Only one mesh affected B 0 homogeneity. Overall, we recommend the coated foil HS 9400 for integration concepts as it exhibited a good performance with SE = 25 dB, PA = 22%, resulting in a PET performance of dE/E = 12% and CRT = 274 ps.