Jeongan Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jeongan Choi has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Jihyung Yoo
Hanyang University, Seoul 04763, South Korea
3 shared publications - Dae Hoon Lee
Nitro Future Initiative Global Top Research Lab, Korea Institute of Machinery and Materials 3 , 156, Gajeongbuk-ro, Yuseong-gu, Daejeon 34103
2 shared publications - Rajavasanth Rajasegar
Department of Mechanical Science and Engineering, University of Illinois at Urbana–Champaign, Urbana, IL, USA
2 shared publications Tonghun Lee
University of Illinois at Urbana-Champaign, Urbana, IL, 61801, USA
2 shared publications- Chanmi Jung
Semiconductor Manufacturing Research Center, Korea Institute of Machinery and Materials, Daejeon, Republic of Korea
1 shared publication Dae Hoon Lee
1 shared publication
Latest Publications
- 5 August 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 264
Rapid start-up ammonia cracking for on-demand hydrogen using rotating gliding arc plasma–catalyst coupling
- 5 August 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 264
Rapid start-up ammonia cracking for on-demand hydrogen using rotating gliding arc plasma–catalyst coupling
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Electrohydrodynamic wall jets from surface dielectric barrier discharge in confined air and nitrogen flows
We examined the effects of gas composition on ionic wind generation by surface dielectric barrier discharge (SDBD) in a confined rectangular channel. Air and nitrogen cases were compared under 2 kHz sinusoidal excitation while varying the applied voltage using the same channel and bulk flow rate. To characterize the coupled discharge-flow response, electrical measurements, optical imaging, and particle image velocimetry (PIV) were performed in the same configuration. Electrical measurements show that nitrogen discharges produce greater charge transfer and higher input power than air, accompanied by stronger optical emission and longer streamer propagation under comparable voltage conditions. From the PIV measurements, air produces higher near-electrode wall-jet velocities, whereas nitrogen sustains near-wall momentum farther downstream. The zero-dimensional ZDPlasKin kinetic calculation indicates different charge-carrier evolution in the two gases, with oxygen-based negative-ion formation and post-field persistence being more pronounced in air. The kinetic result is used to support the gas-dependent charge-carrier interpretation, while the wall-jet response is interpreted together with the measured discharge footprint and the phase-dependent nature of electrohydrodynamic forcing. These findings show that the electrical/optical discharge response and the wall-jet response do not necessarily scale together in confined SDBD actuation.
- 1 August 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (8)
Electrohydrodynamic wall jets from surface dielectric barrier discharge in confined air and nitrogen flows
We examined the effects of gas composition on ionic wind generation by surface dielectric barrier discharge (SDBD) in a confined rectangular channel. Air and nitrogen cases were compared under 2 kHz sinusoidal excitation while varying the applied voltage using the same channel and bulk flow rate. To characterize the coupled discharge-flow response, electrical measurements, optical imaging, and particle image velocimetry (PIV) were performed in the same configuration. Electrical measurements show that nitrogen discharges produce greater charge transfer and higher input power than air, accompanied by stronger optical emission and longer streamer propagation under comparable voltage conditions. From the PIV measurements, air produces higher near-electrode wall-jet velocities, whereas nitrogen sustains near-wall momentum farther downstream. The zero-dimensional ZDPlasKin kinetic calculation indicates different charge-carrier evolution in the two gases, with oxygen-based negative-ion formation and post-field persistence being more pronounced in air. The kinetic result is used to support the gas-dependent charge-carrier interpretation, while the wall-jet response is interpreted together with the measured discharge footprint and the phase-dependent nature of electrohydrodynamic forcing. These findings show that the electrical/optical discharge response and the wall-jet response do not necessarily scale together in confined SDBD actuation.
- 22 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (5)
Numerical Modeling of n-Hexane Pyrolysis with an Optimized Kinetic Mechanism in a Hydrogen Plasma Reactor
The physicochemical mechanisms underlying the pyrolysis of n-hexane in a high temperature Ar-H 2 environment were investigated for plasma pyrolysis process. An optimal chemical kinetics model was developed using the Reaction Mechanism Generator (RMG), an automated tool for constructing reaction mechanisms. This model was validated through 0-D analyses, where simulation result were compared with existing kinetic models (LLNL, JetSurf) and experimental data from conventional n-hexane pyrolysis. Subsequently, 1-D analysis were conducted to identify the optimal operational flow rate in plasma pyrolysis reactor, the results of which informed detailed three-dimensional (2-D) computational fluid dynamics (CFD) modeling of the plasma reactor. The CFD simulations reveal that fluid mixing dynamics play a dominant role in determining the extent of conversion and product selectivity, highlighting the limitations of lower-dimensional models in capturing essential transport phenomena. Notably, the simulations indicate a higher C 2 monomer selectivity of approximately 50 % under plasma-based n-hexane pyrolysis, in contrast to the roughly 30 % selectivity achieved via conventional fossil-fuel-based methods. These findings underscore the potential advantages of plasma-driven pyrolysis and represent a critical step toward a comprehensive understanding of the complex thermo-chemical behavior governing plasma assisted processes.
- 22 January 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (5)
Numerical Modeling of n-Hexane Pyrolysis with an Optimized Kinetic Mechanism in a Hydrogen Plasma Reactor
The physicochemical mechanisms underlying the pyrolysis of n-hexane in a high temperature Ar-H 2 environment were investigated for plasma pyrolysis process. An optimal chemical kinetics model was developed using the Reaction Mechanism Generator (RMG), an automated tool for constructing reaction mechanisms. This model was validated through 0-D analyses, where simulation result were compared with existing kinetic models (LLNL, JetSurf) and experimental data from conventional n-hexane pyrolysis. Subsequently, 1-D analysis were conducted to identify the optimal operational flow rate in plasma pyrolysis reactor, the results of which informed detailed three-dimensional (2-D) computational fluid dynamics (CFD) modeling of the plasma reactor. The CFD simulations reveal that fluid mixing dynamics play a dominant role in determining the extent of conversion and product selectivity, highlighting the limitations of lower-dimensional models in capturing essential transport phenomena. Notably, the simulations indicate a higher C 2 monomer selectivity of approximately 50 % under plasma-based n-hexane pyrolysis, in contrast to the roughly 30 % selectivity achieved via conventional fossil-fuel-based methods. These findings underscore the potential advantages of plasma-driven pyrolysis and represent a critical step toward a comprehensive understanding of the complex thermo-chemical behavior governing plasma assisted processes.
- 1 October 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (74) , 37098-37107
Effects of hydrogen enhancement on mesoscale burner array flame stability under acoustic perturbations
- 1 October 2021
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 46 (74) , 37098-37107
Effects of hydrogen enhancement on mesoscale burner array flame stability under acoustic perturbations
- 14 June 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (13) , 10796-10804
Jet A Combustion in a Mesoscale Swirl-Stabilized Combustor Array
- 14 June 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (13) , 10796-10804
Jet A Combustion in a Mesoscale Swirl-Stabilized Combustor Array
- 9 June 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (9) , 095502
High-speed supercontinuum laser absorption spectroscopy of light hydrocarbons in elevated pressures and temperatures
10 kHz near-infrared supercontinuum laser absorption spectroscopy measurements of methane (CH 4 ) and acetylene (C 2 H 2 ) were demonstrated. Measured absorption spectra were processed using the HITRAN database to infer species concentrations and temperatures. High pressure and high temperature measurements up to 10 bar and 800 K, respectively, were made in dedicated optical cells. Reacting flow field was also probed over a 6 cm flat flame burner. Due to the very short pathlength over the burner surface, a toroidal multipass reflection cell was used to maximize measurement sensitivity. The multipass cell was designed specifically to withstand high temperature environment around the flat flame burner and supported multiple beam pathlength configurations. The beam paths within the cell exist on a thin plane and were used to measure temperatures at various heights above the burner surface. Despite relatively low signal-to-noise ratio at higher temperature environments, species concentration predictions agreed well with experiment conditions. Temperature results agreed well with simulated results to within 20.2 K in the preheat zone of a methane–air flame.
- 9 June 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (9) , 095502
High-speed supercontinuum laser absorption spectroscopy of light hydrocarbons in elevated pressures and temperatures
10 kHz near-infrared supercontinuum laser absorption spectroscopy measurements of methane (CH 4 ) and acetylene (C 2 H 2 ) were demonstrated. Measured absorption spectra were processed using the HITRAN database to infer species concentrations and temperatures. High pressure and high temperature measurements up to 10 bar and 800 K, respectively, were made in dedicated optical cells. Reacting flow field was also probed over a 6 cm flat flame burner. Due to the very short pathlength over the burner surface, a toroidal multipass reflection cell was used to maximize measurement sensitivity. The multipass cell was designed specifically to withstand high temperature environment around the flat flame burner and supported multiple beam pathlength configurations. The beam paths within the cell exist on a thin plane and were used to measure temperatures at various heights above the burner surface. Despite relatively low signal-to-noise ratio at higher temperature environments, species concentration predictions agreed well with experiment conditions. Temperature results agreed well with simulated results to within 20.2 K in the preheat zone of a methane–air flame.
- Open Access
- 2 November 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 15983
Integrated micro-optofluidic platform for real-time detection of airborne microorganisms
We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent to non-fluorescent particles. To apply this method to real-time detection of airborne microorganisms, airborne Escherichia coli, Bacillus subtilis and Staphylococcus epidermidis cells were introduced into the micro-optofluidic platform via bioaerosol generation and a liquid-type particle collection setup was used. We demonstrate successful discrimination of SYTO82-dyed fluorescent bacterial cells from other residue particles in a continuous and real-time manner. In comparison with traditional microscopy cell counting and colony culture methods, this micro-optofluidic platform is not only more accurate in terms of the detection efficiency for airborne microorganisms but it also provides additional information on the total particle number concentration.
- 2 November 2015
- Published by Springer Nature in Scientific Reports
- Vol. 5 (1) , 15983
Open AccessIntegrated micro-optofluidic platform for real-time detection of airborne microorganisms
We demonstrate an integrated micro-optofluidic platform for real-time, continuous detection and quantification of airborne microorganisms. Measurements of the fluorescence and light scattering from single particles in a microfluidic channel are used to determine the total particle number concentration and the microorganism number concentration in real-time. The system performance is examined by evaluating standard particle measurements with various sample flow rates and the ratios of fluorescent to non-fluorescent particles. To apply this method to real-time detection of airborne microorganisms, airborne Escherichia coli, Bacillus subtilis and Staphylococcus epidermidis cells were introduced into the micro-optofluidic platform via bioaerosol generation and a liquid-type particle collection setup was used. We demonstrate successful discrimination of SYTO82-dyed fluorescent bacterial cells from other residue particles in a continuous and real-time manner. In comparison with traditional microscopy cell counting and colony culture methods, this micro-optofluidic platform is not only more accurate in terms of the detection efficiency for airborne microorganisms but it also provides additional information on the total particle number concentration.