Julien Angot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Julien Angot has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Olli Tarvainen
STFC ISIS Pulsed Spallation Neutron and Muon Facility, Rutherford Appleton Laboratory 2 , Harwell OX11 0QX
6 shared publications Thomas Thuillier
University of Grenoble Alpes
6 shared publications- Thomas Thuillier
University of Grenoble Alpes
6 shared publications - Alessio Galatà
Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Legnaro (INFN-LNL), Viale dell’Universita, 2, 35020 Legnaro, Italy
5 shared publications - Laurent Maunoury
Grand Accelerateur National d’Ions Lourds 1 , Bd Henri Becquerel, 14076 Caen, France
5 shared publications - Hannu Koivisto
Accelerator Laboratory, Department of Physics, University of Jyväskylä 1 , FI-40014 Jyväskylä
4 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3237 (1)
Plasma diagnostics of charge breeder ECR ion sources
The Electron Cyclotron Resonance (ECR) charge breeding technique was invented in the 1990s, in the context of developing Isotope Separation On-Line facilities for the study of atomic nuclei far from stability. Different ion sources were built worldwide based on the second generation minimum-B ECR ion source, operating at 10 – 18 GHz. In an ECR charge breeder, a beam of 1+ ions is injected and captured in the plasma, where the ions are multi-ionised by electron impact and extracted with the support gas ions. We present a comprehensive description of the plasma diagnostics studies on the LPSC ECR Charge Breeder (CB) in parallel to its development towards higher breeding efficiency. Analysing the uncaptured fraction of the injected beam passing through the CB allowed estimating the electron density together with limits to ion-ion collision frequencies in the CB plasma. Pulsed mode injection of the 1+ beam was used to study the high charge state production efficiency and estimate plasma parameters such as the characteristic times, electron density or electron temperature. To refine the capture model, comparative measurements with different injected species into the CB demonstrated that the plasma potential plays a key role in 1+ ion capture.
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3237 (1)
Open AccessPlasma diagnostics of charge breeder ECR ion sources
The Electron Cyclotron Resonance (ECR) charge breeding technique was invented in the 1990s, in the context of developing Isotope Separation On-Line facilities for the study of atomic nuclei far from stability. Different ion sources were built worldwide based on the second generation minimum-B ECR ion source, operating at 10 – 18 GHz. In an ECR charge breeder, a beam of 1+ ions is injected and captured in the plasma, where the ions are multi-ionised by electron impact and extracted with the support gas ions. We present a comprehensive description of the plasma diagnostics studies on the LPSC ECR Charge Breeder (CB) in parallel to its development towards higher breeding efficiency. Analysing the uncaptured fraction of the injected beam passing through the CB allowed estimating the electron density together with limits to ion-ion collision frequencies in the CB plasma. Pulsed mode injection of the 1+ beam was used to study the high charge state production efficiency and estimate plasma parameters such as the characteristic times, electron density or electron temperature. To refine the capture model, comparative measurements with different injected species into the CB demonstrated that the plasma potential plays a key role in 1+ ion capture.
- Open Access
- 1 May 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (5)
Experimental investigation of electrostatic capture of 1+ ions in charge breeder electron cyclotron resonance ion source plasma
We present comprehensive experimental data demonstrating that the capture process of the 1+ ions in charge breeder electron cyclotron resonance ion sources (ECRIS) is dominated by electrostatic deceleration by the ambipolar plasma potential, not by cumulative small-angle scattering of the incident ions in ion–ion collisions as postulated previously. To achieve this we varied the plasma potential of an ECRIS charge breeder by adjusting the microwave power applied to sustain the helium discharge and measured the corresponding shift in the optimum injection energy of the 1+ ions. The experiment was repeated with sodium, potassium, and cesium ions. It is shown that the optimum injection energy does not depend on the incident ion mass, which contradicts the collisional drag model. Conversely, the optimum injection energy (in eV) shifts in unison with the plasma potential (in V), which provides strong evidence for the electrostatic deceleration hypothesis.
- 1 May 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (5)
Open AccessExperimental investigation of electrostatic capture of 1+ ions in charge breeder electron cyclotron resonance ion source plasma
We present comprehensive experimental data demonstrating that the capture process of the 1+ ions in charge breeder electron cyclotron resonance ion sources (ECRIS) is dominated by electrostatic deceleration by the ambipolar plasma potential, not by cumulative small-angle scattering of the incident ions in ion–ion collisions as postulated previously. To achieve this we varied the plasma potential of an ECRIS charge breeder by adjusting the microwave power applied to sustain the helium discharge and measured the corresponding shift in the optimum injection energy of the 1+ ions. The experiment was repeated with sodium, potassium, and cesium ions. It is shown that the optimum injection energy does not depend on the incident ion mass, which contradicts the collisional drag model. Conversely, the optimum injection energy (in eV) shifts in unison with the plasma potential (in V), which provides strong evidence for the electrostatic deceleration hypothesis.
- Open Access
Diagnostics of charge breeder electron cyclotron resonance ion source plasma with consecutive transients method
The consecutive transients (CT) method is a diagnostics approach combining experimental and computational techniques to probe the plasma parameters of Charge Breeder Electron Cyclotron Resonance Ion Sources (CB-ECRIS). The method is based on short pulse injection of singly charged ions into the charge breeder plasma, and the measurement of the resulting transients of the charge bred multiply charged ions. Estimates for plasma density, average electron energy and characteristic times of ion confinement, electron impact ionization and charge exchange are then computationally derived from the experimental data. Here the CT method is applied for parametric studies of CBECRIS plasma. Potassium ions were charge bred with hydrogen support plasma, and the effects of varied microwave power, neutral gas pressure and magnetic field strength on the plasma parameters and charge breeding efficiency are presented. It is shown that the method is sufficiently sensitive to provide relevant information on changing plasma conditions with the control parameters. The neutral gas pressure had the strongest impact on the plasma parameters, and the results agree with trends obtained by using other diagnostic methods, e.g. the increase of plasma density with increased neutral gas pressure. Furthermore, the method can provide information inaccessible with other methods, such as the characteristic times of ion confinement, ionization and charge exchange, and the hierarchy between them. The results show that the peak charge breeding efficiency is obtained for the highest ion charge state for which the ionization time remains shorter than the charge exchange and the ion confinement times.
Open AccessDiagnostics of charge breeder electron cyclotron resonance ion source plasma with consecutive transients method
The consecutive transients (CT) method is a diagnostics approach combining experimental and computational techniques to probe the plasma parameters of Charge Breeder Electron Cyclotron Resonance Ion Sources (CB-ECRIS). The method is based on short pulse injection of singly charged ions into the charge breeder plasma, and the measurement of the resulting transients of the charge bred multiply charged ions. Estimates for plasma density, average electron energy and characteristic times of ion confinement, electron impact ionization and charge exchange are then computationally derived from the experimental data. Here the CT method is applied for parametric studies of CBECRIS plasma. Potassium ions were charge bred with hydrogen support plasma, and the effects of varied microwave power, neutral gas pressure and magnetic field strength on the plasma parameters and charge breeding efficiency are presented. It is shown that the method is sufficiently sensitive to provide relevant information on changing plasma conditions with the control parameters. The neutral gas pressure had the strongest impact on the plasma parameters, and the results agree with trends obtained by using other diagnostic methods, e.g. the increase of plasma density with increased neutral gas pressure. Furthermore, the method can provide information inaccessible with other methods, such as the characteristic times of ion confinement, ionization and charge exchange, and the hierarchy between them. The results show that the peak charge breeding efficiency is obtained for the highest ion charge state for which the ionization time remains shorter than the charge exchange and the ion confinement times.
- Open Access
- 1 July 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (7)
The effects of electron energy distribution and ionization cross section uncertainty on charge breeder ion source diagnostics with pulsed 1+ injection
The consecutive transients (CT) method is a plasma diagnostic technique of charge breeder electron cyclotron resonance ion source plasmas. It is based on the short-pulse injection of singly charged ions and the measurement of the resulting transients of the extracted multi-charged ion beams. Here, we study the origin of the large uncertainty bounds yielded by the method to reveal avenues to improve its accuracy. We investigate effects of the assumed electron energy distribution (EED) and the uncertainty inherited from the ionization cross section data of K4+–K12+ ions on the resulting plasma electron density ne, average energy ⟨Ee⟩, and the characteristic times of ion confinement τq, electron impact ionization τinzq, and charge exchange τcxq provided by the CT method. The role of the EED was probed with Kappa and double-Maxwellian distributions, the latter resulting in a shift of the ne and ⟨Ee⟩ distributions. The uncertainty of the ionization cross section σq→q+1inz was artificially curtailed to investigate its impact on values and uncertainties of the plasma parameters. It is demonstrated that the hypothetical perfect knowledge of σq→q+1inz significantly reduces the uncertainties of τq, τinzq, and τcxq, which motivates the need for improved cross section data.
- 1 July 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (7)
Open AccessThe effects of electron energy distribution and ionization cross section uncertainty on charge breeder ion source diagnostics with pulsed 1+ injection
The consecutive transients (CT) method is a plasma diagnostic technique of charge breeder electron cyclotron resonance ion source plasmas. It is based on the short-pulse injection of singly charged ions and the measurement of the resulting transients of the extracted multi-charged ion beams. Here, we study the origin of the large uncertainty bounds yielded by the method to reveal avenues to improve its accuracy. We investigate effects of the assumed electron energy distribution (EED) and the uncertainty inherited from the ionization cross section data of K4+–K12+ ions on the resulting plasma electron density ne, average energy ⟨Ee⟩, and the characteristic times of ion confinement τq, electron impact ionization τinzq, and charge exchange τcxq provided by the CT method. The role of the EED was probed with Kappa and double-Maxwellian distributions, the latter resulting in a shift of the ne and ⟨Ee⟩ distributions. The uncertainty of the ionization cross section σq→q+1inz was artificially curtailed to investigate its impact on values and uncertainties of the plasma parameters. It is demonstrated that the hypothetical perfect knowledge of σq→q+1inz significantly reduces the uncertainties of τq, τinzq, and τcxq, which motivates the need for improved cross section data.
- Open Access
The longitudinal energy spread of ion beams extracted from an electron cyclotron resonance ion source
We present a study of factors affecting the energy spread of ion beams extracted from a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS). The comprehensive simulations, supported by experiments with a Retarding Field Analyser (RFA), reveal that the longitudinal and transverse energy spread of the extracted beams are strongly affected by the electrostatic focusing effects, namely the extraction geometry and plasma beam boundary, to the extent that the electrostatic effects dominate over the magnetic field induced rotation of the beam or the effect of plasma potential and ion temperature. The dominance of the electrostatic focusing effect over the magnetic field induced rotation complicates parametric studies of the transverse emittance as a function of the magnetic field strength, and comparison of emittance values obtained with different ion sources having different extraction designs. Our results demonstrate that the full ion beam energy spread, relevant for the downstream accelerator, can be measured with the RFA only when all ions are collected. On the contrary, studying the effect of plasma properties (plasma potential and ion temperature) on the longitudinal energy spread requires heavy collimation of the beam accepting only ions near the symmetry axis of the beam for which the electrostatic and magnetic effects are suppressed. As the extraction system of the CB-ECRIS is similar to a conventional ECRIS, the conclusions of the study can be generalised to apply for all high charge state ECR ion sources. Finally, we present the results of systematic plasma potential measurements of the Phoenix-type CB-ECRIS at LPSC, varying the source potential, the microwave power and the axial magnetic field srength. It was observed that the plasma potential increases with the extraction magnetic field and the microwave power.
Open AccessThe longitudinal energy spread of ion beams extracted from an electron cyclotron resonance ion source
We present a study of factors affecting the energy spread of ion beams extracted from a Charge Breeder Electron Cyclotron Resonance Ion Source (CB-ECRIS). The comprehensive simulations, supported by experiments with a Retarding Field Analyser (RFA), reveal that the longitudinal and transverse energy spread of the extracted beams are strongly affected by the electrostatic focusing effects, namely the extraction geometry and plasma beam boundary, to the extent that the electrostatic effects dominate over the magnetic field induced rotation of the beam or the effect of plasma potential and ion temperature. The dominance of the electrostatic focusing effect over the magnetic field induced rotation complicates parametric studies of the transverse emittance as a function of the magnetic field strength, and comparison of emittance values obtained with different ion sources having different extraction designs. Our results demonstrate that the full ion beam energy spread, relevant for the downstream accelerator, can be measured with the RFA only when all ions are collected. On the contrary, studying the effect of plasma properties (plasma potential and ion temperature) on the longitudinal energy spread requires heavy collimation of the beam accepting only ions near the symmetry axis of the beam for which the electrostatic and magnetic effects are suppressed. As the extraction system of the CB-ECRIS is similar to a conventional ECRIS, the conclusions of the study can be generalised to apply for all high charge state ECR ion sources. Finally, we present the results of systematic plasma potential measurements of the Phoenix-type CB-ECRIS at LPSC, varying the source potential, the microwave power and the axial magnetic field srength. It was observed that the plasma potential increases with the extraction magnetic field and the microwave power.
- Open Access
- 1 December 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (12) , 125003
The capture of injected 1+ ions in charge breeder electron cyclotron resonance ion source plasma
The capture process of the 1+ ions in charge breeder electron cyclotron resonance ion sources has been attributed to cumulative small-angle scattering of the incident ions in ion–ion collisions with the buffer gas ions. The model results in controversy between the plasma potential and ion temperature values derived from simulations, and those found in the experiments. We demonstrate that the 1+ ion capture process is dominated by the slowing down of the incident ions by the ambipolar plasma potential, which has previously been assigned with a secondary importance. In this revised view, supported by experimental data, the 1+ capture does not depend on the mass of the injected and plasma ion species, or the ion temperature, which resolves the disagreement between modelling and experiments.
- 1 December 2022
- Published by IOP Publishing in Plasma Sources Science and Technology
- Vol. 31 (12) , 125003
Open AccessThe capture of injected 1+ ions in charge breeder electron cyclotron resonance ion source plasma
The capture process of the 1+ ions in charge breeder electron cyclotron resonance ion sources has been attributed to cumulative small-angle scattering of the incident ions in ion–ion collisions with the buffer gas ions. The model results in controversy between the plasma potential and ion temperature values derived from simulations, and those found in the experiments. We demonstrate that the 1+ ion capture process is dominated by the slowing down of the incident ions by the ambipolar plasma potential, which has previously been assigned with a secondary importance. In this revised view, supported by experimental data, the 1+ capture does not depend on the mass of the injected and plasma ion species, or the ion temperature, which resolves the disagreement between modelling and experiments.
- 16 November 2022
- Published by American Physical Society (APS) in Physical Review E
- Vol. 106 (5) , 055208
Diagnostics of highly charged plasmas with multicomponent ion injectionWe establish multicomponent injection into a charge breeder electron cyclotron resonance ion source and an associated computational procedure as a noninvasive probe of the electron density , average electron energy , and the characteristic times of ionization, charge exchange, and ion confinement of stochastically heated, highly charged plasma. Multicomponent injection allows refining the , ranges, reducing experimental uncertainty. Na/K injection is presented as a demonstration. The and of a hydrogen discharge are found to be and , respectively. The ionization, charge exchange, and confinement times of high charge state alkali ions are on the order of 1 ms–10 ms.- 16 November 2022
- Published by American Physical Society (APS) in Physical Review E
- Vol. 106 (5) , 055208
Diagnostics of highly charged plasmas with multicomponent ion injectionWe establish multicomponent injection into a charge breeder electron cyclotron resonance ion source and an associated computational procedure as a noninvasive probe of the electron density , average electron energy , and the characteristic times of ionization, charge exchange, and ion confinement of stochastically heated, highly charged plasma. Multicomponent injection allows refining the , ranges, reducing experimental uncertainty. Na/K injection is presented as a demonstration. The and of a hydrogen discharge are found to be and , respectively. The ionization, charge exchange, and confinement times of high charge state alkali ions are on the order of 1 ms–10 ms.- 1 March 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (3) , 039901
Publisher’s Note: “Charge breeders: Development of diagnostic tools to probe the underlying physics” [Rev. Sci. Instrum. 93, 021101 (2022)]
- 1 March 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (3) , 039901
Publisher’s Note: “Charge breeders: Development of diagnostic tools to probe the underlying physics” [Rev. Sci. Instrum. 93, 021101 (2022)]
- 1 February 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (2) , 021101
Charge breeders: Development of diagnostic tools to probe the underlying physics
Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron–ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.
- 1 February 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (2) , 021101
Charge breeders: Development of diagnostic tools to probe the underlying physics
Charge breeders were developed more than 20 years ago in the context of radioactive ion beam (RIB) production. The main goal is to boost the charge state of a singly charged RIB to a higher value matching the A/Q of a post-accelerator. In that way, the RIB produced at some tens of keV can efficiently be accelerated to energies in a range of few MeV/u up to several tens of MeV/u, which is of interest for nuclear structure and nuclear astrophysics experiments. Two families of charge breeders have been developed: one based on Electron Cyclotron Resonance Ion Sources (ECRISs) suitable for Continuous Wave (CW) operation and another built around Electron Beam Ion Sources (EBISs) used for pulsed post-accelerators. For many years, experimental studies have been carried out to enhance the charge breeding process and improve the extracted beam quality, i.e., purity, intensity, emittance, and time structure. The evolution of the charge breeders is also closely related to the emergence of new facilities delivering even more exotic beams. Diagnostic tools, such as Faraday cups, beam profile monitors, and emittance scanners, are mandatory to tune the machines and evaluate their performances. However, to go beyond that, a better understanding of plasma physics (in ECRIS) and electron–ion interactions (in EBIS), as well as the 1+ beam characteristics, for instance, energy spread transverse emittance, is needed. Therefore, simulation codes modeling the physics phenomena in both type of charge breeders were developed to support the understanding of experimental outputs and to gain insights into non-observable parameters. Nevertheless, more sophisticated diagnostic tools are required to improve the charge breeding performance and to extend the potential applications toward new RIB facilities. This Review will present the two kinds of charge breeders and their technical evolutions. It will review the diagnostic tools and simulation codes employed for operation and evaluation of the internal physics processes.