JPJennifer Sara Polson

Jennifer Sara Polson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jennifer Sara Polson has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Deep Learning Approach to Predict Recanalization First-Pass Effect following Mechanical Thrombectomy in Patients with Acute Ischemic Stroke

    by Haoyue Zhang, Jennifer S. Polson, Zichen Wang, Kambiz Nael, Neal M. Rao, William F. Speier, Corey W. Arnold

    BACKGROUND AND PURPOSE: Following endovascular thrombectomy in patients with large-vessel occlusion stroke, successful recanalization from 1 attempt, known as the first-pass effect, has correlated favorably with long-term outcomes. Pretreatment imaging may contain information that can be used to predict the first-pass effect. Recently, applications of machine learning models have shown promising results in predicting recanalization outcomes, albeit requiring manual segmentation. In this study, we sought to construct completely automated methods using deep learning to predict the first-pass effect from pretreatment CT and MR imaging. MATERIALS AND METHODS: Our models were developed and evaluated using a cohort of 326 patients who underwent endovascular thrombectomy at UCLA Ronald Reagan Medical Center from 2014 to 2021. We designed a hybrid transformer model with nonlocal and cross-attention modules to predict the first-pass effect on MR imaging and CT series. RESULTS: The proposed method achieved a mean 0.8506 (SD, 0.0712) for cross-validation receiver operating characteristic area under the curve (ROC-AUC) on MR imaging and 0.8719 (SD, 0.0831) for cross-validation ROC-AUC on CT. When evaluated on the prospective test sets, our proposed model achieved a mean ROC-AUC of 0.7967 (SD, 0.0335) with a mean sensitivity of 0.7286 (SD, 0.1849) and specificity of 0.8462 (SD, 0.1216) for MR imaging and a mean ROC-AUC of 0.8051 (SD, 0.0377) with a mean sensitivity of 0.8615 (SD, 0.1131) and specificity 0.7500 (SD, 0.1054) for CT, respectively, representing the first classification of the first-pass effect from MR imaging alone and the first automated first-pass effect classification method in CT. CONCLUSIONS: Results illustrate that both nonperfusion MR imaging and CT from admission contain signals that can predict a successful first-pass effect following endovascular thrombectomy using our deep learning methods without requiring time-intensive manual segmentation.


  • Open Access

    Predicting Thrombectomy Recanalization from CT Imaging Using Deep Learning Models

    by Haoyue Zhang, Jennifer S. Polson, Eric J. Yang, Kambiz Nael, William Speier, Corey W. Arnold

    For acute ischemic stroke (AIS) patients with large vessel occlusions, clinicians must decide if the benefit of mechanical thrombectomy (MTB) outweighs the risks and potential complications following an invasive procedure. Pre-treatment computed tomography (CT) and angiography (CTA) are widely used to characterize occlusions in the brain vasculature. If a patient is deemed eligible, a modified treatment in cerebral ischemia (mTICI) score will be used to grade how well blood flow is reestablished throughout and following the MTB procedure. An estimation of the likelihood of successful recanalization can support treatment decision-making. In this study, we proposed a fully automated prediction of a patient's recanalization score using pre-treatment CT and CTA imaging. We designed a spatial cross attention network (SCANet) that utilizes vision transformers to localize to pertinent slices and brain regions. Our top model achieved an average cross-validated ROC-AUC of 77.33 $\pm$ 3.9\%. This is a promising result that supports future applications of deep learning on CT and CTA for the identification of eligible AIS patients for MTB.


  • Open Access

    Automated Assessment of the DWI-FLAIR Mismatch in Patients with Acute Ischemic Stroke: Added Value to Routine Clinical Practice

    by Elham Tavakkol, Shingo Kihira, Mark McArthur, Jennifer Sara Polson, Haoyue Zhang, Corey W. Arnold, Bryan Y. Yoo, Michael Linetsky, Banafsheh Salehi, Luke N. Ledbetter, et al.

    BACKGROUND AND PURPOSE: DWI-FLAIR mismatch is used to determine thrombolytic eligibility in patients with acute ischemic stroke (AIS) when time since stroke onset (TSS) is unknown. Commercial software packages have been developed for automated DWI-FLAIR classification. We aimed to use e-Stroke software (Brainomix, Oxford, UK) for automated classification of DWI-FLAIR mismatch in a cohort of patients with AIS and in a comparative analysis with two expert neuroradiologists. MATERIALS AND METHODS: In this retrospective study, patients with AIS who had MRI and known TSS were included. DWI-FLAIR mismatch was evaluated by two neuroradiologists blinded to TSS and automatically by e-Stroke software. After 4 weeks, the neuroradiologists reevaluated the MRIs, this time equipped with automated predicted e-Stroke results as a computer assisted tool (CAT). Diagnostic performances of e-Stroke software and neuroradiologists were evaluated for prediction of DWI-FLAIR mismatch status. RESULTS: A total of 157 patients met inclusion criteria. A total of 82 patients (52%) had TSS ≤ 4.5 hours. Using consensus reads, 81 patients (51.5%) had DWI-FLAIR mismatch. The diagnostic accuracy (AUC/sensitivity/specificity) of e-Stroke software for determination of DWI-FLAIR mismatch was 0.72/90.0/53.9. The diagnostic accuracy (AUC/sensitivity/specificity) for neuroradiologist 1 and 2 was 0.76/69.1/84.2 and was 0.82/91.4/73.7 respectively, both significantly (p<0.05) improved to 0.83/79.0/86.8 and 0.89/92.6/85.5 respectively following the use of e-Stroke predictions as CAT. The interrater agreement (K) for determination of DWI-FLAIR status was improved from 0.49 to 0.57 following the use of CAT. CONCLUSIONS: Automated quantitative approach for DWI-FLAIR mismatch provides comparable results to human experts and can improve diagnostic accuracies of expert neuroradiologists in determination of DWI-FLAIR status. ABBREVIATIONS: AIS: Acute ischemic stroke; CAT: Computer assisted tool; TSS: Time since stroke onset


  • Open Access

    Perfusion Collateral Index versus Hypoperfusion Intensity Ratio in Assessment of Collaterals in Patients with Acute Ischemic Stroke

    by Brian Tsui, Iris E. Chen, May Nour, Shingo Kihira, Elham Tavakkol, Jennifer Polson, Haoyue Zhang, Joe Qiao, Mersedeh Bahr-Hosseini, Corey Arnold, et al.

    BACKGROUND AND PURPOSE: Perfusion-based collateral indices such as the perfusion collateral index and the hypoperfusion intensity ratio have shown promise in the assessment of collaterals in patients with acute ischemic stroke. We aimed to compare the diagnostic performance of the perfusion collateral index and the hypoperfusion intensity ratio in collateral assessment compared with angiographic collaterals and outcome measures, including final infarct volume, infarct growth, and functional independence. MATERIALS AND METHODS: Consecutive patients with acute ischemic stroke with anterior circulation proximal arterial occlusion who underwent endovascular thrombectomy and had pre- and posttreatment MRI were included. Using pretreatment MR perfusion, we calculated the perfusion collateral index and the hypoperfusion intensity ratio for each patient. The angiographic collaterals obtained from DSA were dichotomized to sufficient (American Society of Interventional and Therapeutic Neuroradiology [ASITN] scale 3–4) versus insufficient (ASITN scale 0–2). The association of collateral status determined by the perfusion collateral index and the hypoperfusion intensity ratio was assessed against angiographic collaterals and outcome measures. RESULTS: A total of 98 patients met the inclusion criteria. Perfusion collateral index values were significantly higher in patients with sufficient angiographic collaterals (P < .001), while there was no significant (P = .46) difference in hypoperfusion intensity ratio values. Among patients with good (mRS 0–2) versus poor (mRS 3–6) functional outcome, the perfusion collateral index of ≥ 62 was present in 72% versus 31% (P = .003), while the hypoperfusion intensity ratio of ≤0.4 was present in 69% versus 56% (P = .52). The perfusion collateral index and the hypoperfusion intensity ratio were both significantly predictive of final infarct volume, but only the perfusion collateral index was significantly (P = .03) associated with infarct growth. CONCLUSIONS: Results show that the perfusion collateral index outperforms the hypoperfusion intensity ratio in the assessment of collateral status, infarct growth, and determination of functional outcomes.


  • PathAL: An Active Learning Framework for Histopathology Image Analysis

    by Wenyuan Li, Jiayun Li, Zichen Wang, Jennifer Polson, Anthony E. Sisk, Dipti P. Sajed, William Speier, Corey W. Arnold

    Deep neural networks, in particular convolutional networks, have rapidly become a popular choice for analyzing histopathology images. However, training these models relies heavily on a large number of samples manually annotated by experts, which is cumbersome and expensive. In addition, it is difficult to obtain a perfect set of labels due to the variability between expert annotations. This paper presents a novel active learning (AL) framework for histopathology image analysis, named PathAL. To reduce the required number of expert annotations, PathAL selects two groups of unlabeled data in each training iteration: one “informative” sample that requires additional expert annotation, and one “confident predictive” sample that is automatically added to the training set using the model’s pseudo-labels. To reduce the impact of the noisy-labeled samples in the training set, PathAL systematically identifies noisy samples and excludes them to improve the generalization of the model. Our model advances the existing AL method for medical image analysis in two ways. First, we present a selection strategy to improve classification performance with fewer manual annotations. Unlike traditional methods focusing only on finding the most uncertain samples with low prediction confidence, we discover a large number of high confidence samples from the unlabeled set and automatically add them for training with assigned pseudo-labels. Second, we design a method to distinguish between noisy samples and hard samples using a heuristic approach. We exclude the noisy samples while preserving the hard samples to improve model performance. Extensive experiments demonstrate that our proposed PathAL framework achieves promising results on a prostate cancer Gleason grading task, obtaining similar performance with 40% fewer annotations compared to the fully supervised learning scenario. An ablation study is provided to analyze the effectiveness of each component in PathAL, and a pathologist reader study is conducted to validate our proposed algorithm.


  • Open Access

    Deep Learning Approaches to Identify Patients within the Thrombolytic Treatment Window

    by Jennifer S Polson, Haoyue Zhang, Kambiz Nael, Noriko Salamon, Bryan Y Yoo, Suzie El-Saden, Sidney Starkman, Namkug Kim, Dong-Wha Kang, William F Speier, et al.

    1. Background: Treatment of acute ischemic stroke is heavily contingent upon time, as there is a strong relationship between time clock and tissue progression. We sought to a develop a deep learning algorithm for classifying time since stroke (TSS) from MR images by comparison to neuroradiologist assessments of imaging signal mismatch and evaluation on external data. Methods: This retrospective study involved patients who underwent MRI from 2011-2019. Models were trained to classify TSS within 4.5 hours; performance metrics with confidence intervals were reported on both internal and external evaluation sets. Results: A total of 772 patients (66 ± 9 years, 319 women) were used for model development and evaluation. Three board-certified neuroradiologists’ assessments, based on majority vote, yielded a sensitivity of 0.62, a specificity of 0.86, and a Fleiss’ kappa of 0.46. The deep learning method performed similarly to radiologists and outperformed previously reported methods, with the best model achieving an average evaluation accuracy, sensitivity, and specificity of 0.726, 0.712, and 0.741, on an internal cohort and 0.724, 0.757, and 0.679, respectively, on an external, unseen evaluation cohort from another institution. Conclusion: This model achieved higher generalization performance on external evaluation datasets than the current state of the art for TSS classification.


  • Intra-domain task-adaptive transfer learning to determine acute ischemic stroke onset time

    by Haoyue Zhang, Jennifer S Polson, Kambiz Nael, Noriko Salamon, Bryan Yoo, Suzie El-Saden, Fabien Scalzo, William Speier, Corey W. Arnold


  • Open Access

    Semi-supervised learning based on generative adversarial network: a comparison between good GAN and bad GAN approach

    by Wenyuan Li, Zichen Wang, Jiayun Li, Jennifer Polson, William Speier, Corey Arnold

    Recently, semi-supervised learning methods based on generative adversarial networks (GANs) have received much attention. Among them, two distinct approaches have achieved competitive results on a variety of benchmark datasets. Bad GAN learns a classifier with unrealistic samples distributed on the complement of the support of the input data. Conversely, Triple GAN consists of a three-player game that tries to leverage good generated samples to boost classification results. In this paper, we perform a comprehensive comparison of these two approaches on different benchmark datasets. We demonstrate their different properties on image generation, and sensitivity to the amount of labeled data provided. By comprehensively comparing these two methods, we hope to shed light on the future of GAN-based semi-supervised learning.


  • Equipping Physiologists with an Informatics Tool Chest: Toward an Integerated Mitochondrial Phenome

    by Anders Olav Garlid, Jennifer S. Polson, Keith D. Garlid, Henning Hermjakob, Peipei Ping

    Understanding the complex involvement of mitochondrial biology in disease development often requires the acquisition, analysis, and integration of large-scale molecular and phenotypic data. An increasing number of bioinformatics tools are currently employed to aid in mitochondrial investigations, most notably in predicting or corroborating the spatial and temporal dynamics of mitochondrial molecules, in retrieving structural data of mitochondrial components, and in aggregating as well as transforming mitochondrial centric biomedical knowledge. With the increasing prevalence of complex Big Data from omics experiments and clinical cohorts, informatics tools have become indispensable in our quest to understand mitochondrial physiology and pathology. Here we present an overview of the various informatics resources that are helping researchers explore this vital organelle and gain insights into its form, function, and dynamics.